• Title/Summary/Keyword: 경골 근위부

Search Result 59, Processing Time 0.034 seconds

External Tibial Torsion with Proximal Tibia Vara in Total Knee Arthroplasty of Advanced Osteoarthritis with Severe Varus Deformed Knees (심한 내반 변형의 진행성 관절염 환자의 인공 슬관절 전치환술 시 경골 근위부의 내반을 동반한 외회전 변형)

  • Sun, Doo-Hoon;Song, In-Soo;Kim, Jun-Beom;Kim, Cheol-U;Jung, Deukhee;Jeong, Uitak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.62-70
    • /
    • 2020
  • Purpose: External tibia torsion and proximal tibial vara have been reported in severe varus deformed osteoarthritis, which is a tibio-femoral angle of more than 20°. The radiology measurements were compared with those of control group and the preoperative and follow-up radiology and clinical results were examined. Materials and Methods: From January 2007 to March 2016, 43 knees from 37 persons, who underwent total knee arthroplasty for a severe varus deformity of more than 20° on the tibio-femoral angle on the standing radiographs and had a follow-up period more than two years, were examined. The mean follow-up period was 45.7 months. The control group, who underwent conservative treatments, had Kellgren-Lawrence grade three osteoarthritis and a tibio-femoral angle of less than 3° varus. The external tibial torsion of enrolled patients and control group were estimated using the proximal tibio-fibular overlap length and the tibial torsion values on computed tomography. The proximal tibia vara was measured using the proximal tibial tilt angle. The preoperative and postoperative proximal tibio-fibular overlap length, tibial torsion value, proximal tibial tilt angle, and hospital for special surgery (HSS) score were evaluated. Results: The mean proximal tibio-fibular overlap length was 18.6 mm preoperatively and 11.2 mm (p=0.031) at the follow-up. The control group had a mean proximal tibio-fibular overlap length of 8.7 mm (p=0.024). The mean tibial torsion value was 13.8° preoperatively and 14.0° (p=0.489) at the follow-up. The control group had a mean tibial torsion value of 21.9° (p=0.012). The mean proximal tibial tilt angle was 12.2° preoperatively and 0° (p<0.01) at the follow-up. The control group had a mean proximal tilt angle of 1.2° (p<0.01). The preoperative tibiofemoral angle and mechanical axis deviation were corrected from preoperative 28.3° and medial 68.4 mm to postoperative 0.7° and medial 3.5 mm (p<0.01, p<0.01), respectively. The HSS scores increased from 34 points of preoperatively to 87 points at the last follow-up (p=0.028). Conclusion: Patients with advanced osteoarthritis with a severe varus deformity of more than 20° had significant increases in the external tibial torsion and varus of the proximal tibia. The tibial torsion value before and after surgery in the enrolled patients was not changed statistically, but good clinical results without complications were obtained.

Comparison of Gap Pressure in Opening Wedge High Tibial Osteotomy versus Compressive Strength of Allogenous Wedge Bone Blocks (경골 근위부 개방 절골술 시 개방부 압력과 동종 쐐기 골편의 최대압축하중 비교)

  • Yoon, Kyoung Ho;Kim, Jung Suk;Kwon, Yoo Beom;Kim, Eung Ju;Lee, Myeong-Kyu;Kim, Sang-Gyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.127-134
    • /
    • 2020
  • Purpose: The aims of this study were (1) to investigate the relationship between the characteristics of allogenic bone block and the compressive strength of an allogenic bone block measured by biomechanical experiments, and (2) to compare the maximum pressure load of allogenic bone block with the gap pressure measured at the high tibial opening osteotomy. Materials and Methods: Ten patients who provided informed consent for gap pressure measurements during opening wedge high tibial osteotomy (OWHTO) were included. The gap pressures were measured at 1 mm intervals while opening the osteotomy site from 8 mm to 14 mm. Seventeen U-shaped allogenous wedge bone blocks were made from the femur, tibia, and humerus. The height, width, cross-sectional area, and cortex thickness of the bone blocks were measured, along with the maximum compressive load just before breakage. The relationship between these characteristics and the maximum pressure load of the bone blocks was evaluated. The gap pressures measured in OWHTO were compared with the maximum pressure loads of the allogenous wedge bone blocks to evaluate the possibility of inserting allogenous wedge bone blocks into the osteotomy site without a distractor in OWHTO. Results: The OWHTO gap pressure increased with increasing osteotomy site opening. The mean gap pressure, which occurred at a 14-mm opening, was 282±93 N; the maximum pressure was 427 N. The maximum pressure load of the allografts was 13,379±6,469 N (minimum, 5,868; maximum, 29,130 N) and was correlated significantly with the cortical bone thickness (correlation coefficient=0.693, p=0.002) and cross-sectional area (correlation coefficient=0.826, p<0.001). Depending on the sterilization method, the maximum pressure loads for the bone blocks were 13,406±5,928 N for freeze-dried and 13,348±7,449 N for fresh frozen. The maximum compressive load of the allogenous wedge bone blocks was 13.7-times greater than that in OWHTO opened to 14 mm (5,868 N vs. 427 N). Conclusion: The compressive strength of allogenous wedge bone blocks was sufficiently greater than the gap pressure in OWHTO. Therefore, allogenous wedge bone blocks can be inserted safely into the osteotomy site without a distractor.

Pretibial Cyst after Anterior Cruciate Ligament Reconstruction Using bio-absorbable interference screw fixation - A Case Report - (생체분해성간섭나사를 이용한 전방십자인대 재건술 후 발생한 경골 근위부 낭종-증례 보고-)

  • Chun, Keun Churl;Kim, Jung Woo;Kim, Tae Kuyn;Chun, Churl Hong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Pretibial cyst formation is a rare complication after anterior cruciate ligament (ACL) reconstruction and there are only few cases reported. Pretibial cyst can be caused by variable reasons. Foreign body reaction due to breakdown of bio-absorbable screw for fixation, graft necrosis at tibial site, joint fluid leakage to tunnel and incomplete incorporation of graft to bony tunnel. The authors experienced one case of massive pretibial cyst after arthroscopic ACL reconstruction using bio-absorbable interference screw in 38-year-old male patient. Thus, authors report this rare case with literature view.

  • PDF

Endoscopic-Assisted Curettage of Brodie Abscess in Proximal Tibia - A Case Report - (경골 근위부에 발생한 Brodie 농양에서 내시경을 이용한 소파술 - 증례 보고 -)

  • Ku, Jung-Hoei;Cho, Hyung-Lae;Park, Man-Jun;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.134-138
    • /
    • 2007
  • Brodie abscess is a localized form of subacute or chronic osteomyelitis which is common in children but may also occur in adulthood. When Brodie abscess is located in the posterior metaphysis of the proximal tibia, open biopsy and curettage have a difficulty in approach to the lesion and can cause neurovascular injury or soft tissue contamination. We report a case wherein a novel surgical technique was used to treat a Brodie abscess in the posterior proximal tibial metaphysis in 48 year-old-male with endoscopic-assisted curettage by commercial anterior cruciate ligament targeting device(Rigid Fix; Mitek, Johnson & Johnson, Norwood, MA). Two portals were created toward the abscess site and, through each portal interchangeably, the granulation tissue and sclerotic bone could be excised. We believe that endoscopic-assisted curettage presents safe technique, decreased morbidity, accurate assessment of the extent of the abscess and possible improvement in long-term outcomes.

  • PDF

Reconstruction of Extensor Mechanism After Prosthetic Replacement of The Proximal Tibia (근위 경골에 발생한 악성종양 절제 후 슬관절 신전력 재건술 -증례 보고-)

  • Park, Jong-Hoon;Oh, Jung-Moon;Kim, Jin-Wook;Lee, Soo-Yong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.120-123
    • /
    • 2004
  • Benign and malignant bone tumors occur most commonly around the knee. The proximal tibia is the most technically demanding site for limb salvage surgery. The most difficult problem using an endoprothesis for proximal tibial resection has been reconstruction of the extensor mechanism. After excision of proximal tibia, we resected distal femur and made a composite with resected distal femur, low heat treated autogenous proximal tibia and endoprothesis. Patella was fixed into the resected down-loaded distal femur. This article shows the new technique and the results of reconstruction of extensor mechanism after prosthetic replacement of the proximal tibia.

  • PDF

Giant Cell-Rich Osteosarcoma of the Proximal Tibia - A Case Report - (경골 근위부에 발생한 거대세포형 골육종 - 증례 보고 -)

  • Kim, Jung-Ryul;Jang, Kyu-Yun;Lee, Sang-Yong;Sohn, Kyung-Rak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.2
    • /
    • pp.155-160
    • /
    • 2006
  • Giant cell-rich osteosarcoma is a rare tumor that is hard to distinguish from giant cell tumors of bone. The location and radiographic aspect of these tumors can be identical. The histologic differentiation between a giant cell-rich osteosarcoma and a giant cell tumor can be difficult. Due to the different prognosis and treatment strategies of these tumors it is essential to make the right diagnosis at presentation. This article reports a case of a giant cell-rich osteosarcoma of the proximal tibia that initially was diagnosed histologically as a giant cell tumor by needle biopsy.

  • PDF

Effect of Anteromedial Cortex Oblique Angle on Change of Tibial Posterior Slope Angle in High Tibial Osteotomy Using Computer Assisted Surgery (CAS) (Computer Assisted Surgery(CAS)를 이용한 개방형 근위경골절골술 시 전내측피질골경사각이 경골후방경사각에 미치는 영향)

  • Lee, Ho-Sang;Kim, Jay-Jung;Wang, Joon-Ho;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.351-361
    • /
    • 2012
  • The leading surgical method for correcting the misalignment of the varus and valgus in the knee joint is the high tibial osteotomy (HTO). In the opening wedge HTO (OWHTO), there is no concern about damaging the peroneal nerve on the lateral tibia of the proximal fibula. OWHTO has been the preferred choice, as the opening of the correction angle can be modulated during the operation. The correction of the varus and valgus on the coronal plane are performed adroitly. Nevertheless, there have been numerous reports of unintended changes in the medial tibial plateau and posterior slope angle (PSA). The authors have developed an HTO method using computer-assisted surgery with the aim of addressing the abovementioned problems from an engineer's perspective. CT images of the high tibia were reconstructed three-dimensionally, and a virtual osteotomy was performed on a computer. In addition, this study recommends a surgical method that does not cause changes in the PSA after OWHTO. The results of the study are expected to suggest a clear relationship between the anteromedial cortex oblique angle of each patient and the PSA, and an optimal PSA selection method for individuals.

Juvenile Hemangioma Occurred in Distal Femoral Epiphysis (소아의 대퇴골 원위부 골단에 발생한 혈관종)

  • Kim, Tai-Seung;Lee, Chang-Hoon;Park, Chan-Keum
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.37-41
    • /
    • 2010
  • A hemangioma occurred in the bony epiphysis is extremly rare. A 5-year-old boy visited to our hospital with pain and flexion contracture on the right knee. MRI showed some lesions scattered in the epiphysis of the distal femur and the proximal tibia. Biopsy specimen from the distal femoral epiphysis revealed pathologic findings compatible with hemangioma. On 8 years follow-up, the lesion in the distal femoral epiphysis had been cured, and those in the proximal tibial epiphysis were spontaneously disappeared without surgery. The scanogram shows no leg length discrepancy and angular deformity. We reports a rare case of hemangioma occurred in the bony epiphysis with the results of 8 year follow-up with the review of literatures.

Transection of the posterior horn of the medial meniscus at the posterior tibial attachment - Clinical features and A new repair technique (Pullout suture) - (내측 반월상 연골 후각의 후방 경골 부착부위의 절단 파열 - 임상 양상 및 새로운 봉합 수기(pullout suture) -)

  • Ahn, Jin-Hwan;Ha, Chul-Won;Kim, Ho;Kim, Sung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.109-114
    • /
    • 1999
  • Purpose : The importance of meniscal repair is well recognized. But transeciton of the posterior horn of the medial meniscus at the posterior tibial attachment is rarely documented and known irreparable. We experienced 9 cases of transection, and present clinical features and pull out suture technique. Methods and Materials : There were 9cases of transection of the posterior horn of medial meniscus from September 1998 to July 1999 in our hospital. Age was 59.3 years in average and ranged from 38 to 70years. Clinical features and MRI made diagnosis in all cases. We confirmed the diagnosis with arthroscopy and repaired the transection with pullout suture technique. Clinical features : Transection of the posterior horn of the medial meniscus at the posterior tibia attachment occurred frequently in middle aged people. They complained posterior knee pain, but they have no history of definitive trauma. Characteristically they had difficulty in full flexion of the knee and in having a squatting position. MRI is very important in diagnosis of transection, especially in coronal view, there is separation of the posterior horn of the meniscus from the posterior tibial attachment. Surgical technique : Pullout suture technique includes debridement of fibrous or scar tissue, exposure of the subchondral bone of the posterior tibial attachment site, suture the transected end of the meniscus with PDS suture, bone tunnel formation from the anteromedial aspect of the proximal tibia, insertion of wire loop through the tibia tunnel, pull the PDS suture through the tibia tunnel out of the joint and stabilize the PDS with post-tie technique to the proximal tibia. Conclusion : Transection of the posterior horn of the medial meniscus at the posterior tibial attachment is not common clinically and rarely documented. Clinical features and MRI are very important in diagnosis of this type tear. Arthroscopic pullout sutures is useful for treatment of this type tear of the meniscus.

  • PDF