• Title/Summary/Keyword: 겉보기

Search Result 709, Processing Time 0.023 seconds

Estimation of Compressive strength of the Fly Ash Substitution cement mortar by Equivalent Age (등가재령에 의한 플라이애시 치환 시멘트 모르타르의 강도증진해석)

  • Son, Ho-Jungn;Han, Sang-Yoon;Cheong, Sang-Hyeon;Ahn, Sang-Ku;Han, Cheon-Goo;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.105-107
    • /
    • 2012
  • This study was conducted to investigate the strength development of fly ash concrete using the strength development estimation for the ready mixed concrete for construction of nuclear reactors. The findings are as follows. First, the higher the curing temperature becomes, the shorter the setting time becomes. In addition, the compressive strength also increased as the curing temperature gets higher. The apparent activation energy derived from ASTM C 1074 showed 34.75 KJ/mol. The results of concrete strength estimation confirmed that Gompertz model formula has good accuracy.

  • PDF

A Study of Sensitivity Verification in UHF Partial Discharge Sensor for 800kV GIS (800kV GIS용 UHF 부분방전 센서 특성시험에 관한 고찰)

  • Park, Kyoung-Su;Kim, Jung-Bae;Song, Won-Pyo;Kim, Duck-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1834-1836
    • /
    • 2002
  • UHF 부분방전시스템은 GIS 내부에서 발생하는 절연이상을 가장 효과적으로 검출해 낼 수 있는 방법이지만, 기존의 IEC60270법에 의해 측정된 겉보기 방전량과는 직접적인 상관관계를 가지지 않는다. 현재 신가평과 신태백의 765kV 변전소에 설치되는 800kV GIS는 제작자가 부분방전센서를 취부하여 납품하여야 한다. 본 논문에서는 한전규격을 만족할 수 있는 센서의 감도시험법에 대하여 고찰하였다.

  • PDF

An Electrorheological (ER) Study on the Silica Suspensions (실리카 현탁액의 전기유변학적 연구)

  • 주상현
    • The Korean Journal of Rheology
    • /
    • v.6 no.1
    • /
    • pp.49-59
    • /
    • 1994
  • 높은 전기장 하에서 다분산, 비구형 실리카/실리콘 오일 현탁액의 전기유변 (electrorheological, ER)현상을 살펴 보았다. 전기유변유체는 전기장 방향으로 사슬구조를 형 성하는 특성을 보이며 이것이 유변물성의 향상에 기여하는 것으로 알려졌다. 동적(dynamic) 상태 실험에서 전기장 하의 실리카 현탁액은 매우낮은 임계변형율(${\gamma}$c =0.1%)이상에서 비선 형 점탄성을 보였다. 저장탄성계수(G')는 변형율 변화에 손실탄성계수(G")는 매질의 점도 에 더 민감한 의존성을 보였다. 또한 겉보기 항복응력은 입자의 부피분율과 전기장에$\Phi$1.9E1.4 의 의존성을 보였는데 부피분율에 대한 의존성이 큰 이유는 0.1 이상의 부피분율에서 복합 사슬 구조 내의 입자들 간의 상호 정전효과가 지배적으로 나타나기 때문이라고 생각된다. 정상상태 실험에서는 부피분율이 크거나 높은 전기장 하에서 전단속도가 0.1sec-1 정도 이하 로 감소함에 따라 전단응력이 급겨히 증가하는 현상을 보였다. 그러므로 본질적인 동적 항 복응력을 얻기 위해서는 매우 낮은 전단속도 영역의 특이한 응력거동을 고려해야한다. 큰 전단속도 하에서는 hydrodynamic interaction의 영향으로 전단속도의 증가에 따라 전단응력 이 증가하였다. 이같은 전단응력의 거동을 계단전단실험으로 확인하였다.

  • PDF

지하수 수질과 토지이용, 토양 특성 및 지질과의 정량적 통계분석

  • Go Gyeong-Seok;Jo Seong-Hyeon;Lee Jin-Su;Kim Tong-Gwon;Kim Jae-Gon;O In-Suk
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.333-337
    • /
    • 2006
  • 논산지역의 간이상수도 수질을 모니터링한 결과 약 13-21% 정도가 간이상수도 수질기준을 초과하는 것으로 확인되었으며 그 원인은 주로 질산성질소, 탁도, 일반세균 등에 의함을 알 수 있었다. 연구지역의 지하수 수질에 영향을 미치는 인자를 정량적으로 해석하기 위하여 토지이용도, 토양도 및 지질도를 작성하여 판별분석을 수행하였다. 판별분석 결과 지하수 수질과 지질은 겉보기 오차율이 5.56%로 매우 밀접한 상관성을 나타내었으나 토지이용과는 52.63%로 상관성이 없는 것으로 나타났으며 이는 점오염원의 효과를 고려하지 못하였기 때문으로 사료된다. 토양특성과는 오차율이 13.16%로 비교적 잘 일치하는 결과를 보여주었으며 이는 토양발달이 지질과 밀접한 상관성을 가지기 때문으로 판단된다.

  • PDF

Apparent and True Proportions (겉보기 비율과 참비율에 관한 연구)

  • Chang, Kyung
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2016
  • The ratio which we usually use in producing products is nonconforming proportion or percent defective. As our modern society develops, we cannot but meet another proportion in legal, managerial, and medical areas where our human beings might commit various kinds of errors though they do not want them. In this paper we will generally call the ratio 'proportion.' When the size of such proportion as percent defective is observed by persons, it is not true proportion but apparent proportion because it has been observed with human or situational errors. Past studies have not systematically covered the analysis of relations between such proportions and type 1 and 2 error, but this paper analyses and derives such various relations, and it suggests the guideline as sixteen properties for utilization and sensitive analysis of the relations. Current paper's consideration of apparent proportion in addition to true proportion as our familiar concept will open and widen existing academic and application areas where people have mainly built societal, scientific and engineering rules and methods based only on true proportion.

Performance Evaluation of an Automotive Fuel Filter by Multi-Pass Filtration Test (다순환 여과시험에 의한 자동차용 연료필터의 성능 평가)

  • 이재천;장지현
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.219-226
    • /
    • 2002
  • Filtration performance of an automotive fuel filter was evaluated based on the theory of Beta ratio. This study also introduced the fuel components' contamination performance test stand incorporating the multi-pass filtration test circuit. The theoretical basis of multi-pass test and test procedure were described in detail. The specification of commercial fuel filter currently available was just the maximum pressure drop across the filter assembly and the holding capacity of contaminants. However, test results revealed that the fuel filter tested could not maintain consistent Beta ratio, that is filtration efficiency, although it had the holding capacity close to the specification. Hence the Beta ratio should be specified in service life. The results also showed that filtration system model should be refined including desorption ratio to estimate the variable Beta ratio in the test.

A Study on the Mixture Properties of IMPEX Reacting Materials for Chemical Heat Pump (화학 열펌프용 IMPEX 혼합반응물의 특성에 관한 연구)

  • ;;Neveu, P.
    • Journal of Energy Engineering
    • /
    • v.3 no.1
    • /
    • pp.44-53
    • /
    • 1994
  • STELF 기술의 핵심의 되는 IMPEX 블록의 잔류 공급률, 겉보기 밀도, 흑연의 혼합비 등 여러 가지 주요 변수가 블록의 특성에 미치는 영향을 조사하여 실제 반응기를 설계하는데 필요한 자료를 구하였다. 대표적인 염들에 대하여 물질전달 및 열전달 문제를 일으키지 않는 영역에서 최소의 부피를 갖는 값들을 계산하였고, 각각의 물질이 갖는 특정 전도도에서의 최대 냉방 및 난방 에너지 밀도를 계산하였다. 이로부터 얻은 값들을 8시간 동안 사용할 수 있는 6kW 냉방용 반응기 설계에 적용하여 본 결과 SrCL2-8/1 NH3가 최적의 염임을 확인하였다.

  • PDF

A strength monitoring with wireless sensor network based on equivalent age method depending on the usage of the insulated formwork during the winter period (동절기 단열 유·무 거푸집을 설치한 슬래브 콘크리트에서 등가재령 기반의 무선센서 네트워크를 이용한 강도 모니터링)

  • Lee, Young-Jun;Lee, Hyuk-Ju;Hyeon, Seung-Yong;Seo, Hang-Goo;Lee, Sang-Woon;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.167-168
    • /
    • 2018
  • In this research, the feasibility of wireless senor for compressive strength evaluation was checked by applying on the actual apartment construction site with insulation formwork during winder period. As a result, there was no significant problem on monitoring the compressive strength of the concrete with the sensor. Thus it is considered that the suggested method can be an efficient method for the quality control at the construction site.

  • PDF

Designed compressive strength assurance method within 28 days of management period for winter period concrete contain various SCMs (한중콘크리트의 관리재령 연장을 이용한 설계기준강도 확보 기법)

  • Lee, Young-Jun;Lee, Hyuk-Ju;Han, Jun-Hui;Lee, Sang-Woon;Lee, Joung-Gyo;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.169-170
    • /
    • 2018
  • The purpose of the research is suggesting the temperature compensation strength for Unicode of constructure standard from Ministry of land, infrastructure and transport. As a result, for the concrete mixture with 100 % OPC, 6, and 3 MPa of compensating strength values were necessary when the temperature were from 4 to 9℃, and from 9 to 17℃, respectively. Additionally, when the temperature was higher than 17℃, compensating strength value was not necessary. In the case of 20 % of blast furnace slag replaced concrete mixture, 9, 6, and 3 MPa of compensating strength values were necessary when the temperature were from 4 to 6℃, from 6 to 12℃, and higher than 17℃, respectively.

  • PDF

The Evaluation of n-Octyl Ethoxy Silane as a Water Repellent of Concrete (콘크리트에서의 n-octyl ethoxy silane 발수제의 성능평가)

  • 황인동;이완조;염희남;정윤중
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.12
    • /
    • pp.1172-1177
    • /
    • 2000
  • 최근 콘크리트 보호 재료는 코팅을 이용하는 과거의 방법에서 함침을 이용하는 기법으로 전환하였다. 이중 발수제는 콘크리트의 표면의 특성을 변화시키는 것으로 친수성의 콘크리트를 소수성 물질을 결합시켜 물에 의한 젖음을 방어하는 것으로 콘크리트에 사용하였을 경우 콘크리트의 고유한 표면 장력을 작게 변화시키고 장력이 큰 물질 중의 하나인 물의 흡수를 방어하게 한다. 본 실험은 발수제의 성능 평가를 위하여 다공질의 재료인 콘크리트의 접촉각을 측정하여 그 변화를 관찰하였으며, 발수제들의 우수한 기능 중의 하나인 통기성을 시편의 중량 감소로 측정하였다. 발수제로 n-octyl ethoxy silane을 사용한 콘크리트 시편의 흡수 능력은 사용하지 않은 것의 약 10% 정도로 측정되었으며 시편의 수분 중량 감소는 7일 동안 90~130%로 관찰되어 통기성이 유지되어 콘크리트의 강도 유지에 효과적임을 알 수 있었다. 또한 겉보기 접촉각은 처리하지 않은 시편에서 24~33$^{\circ}$로 측정되었으나 처리된 시편의 최초면에서 130~141$^{\circ}$이었으며 2mm의 연마면에서는 127~132$^{\circ}$로 측정되어 콘크리트 표면 장력 변화가 유지되고 있음을 알 수 있었다.

  • PDF