• Title/Summary/Keyword: 검출기

Search Result 4,878, Processing Time 0.037 seconds

Statistical Model-Based Voice Activity Detection Using the Second-Order Conditional Maximum a Posteriori Criterion with Adapted Threshold (적응형 문턱값을 가지는 2차 조건 사후 최대 확률을 이용한 통계적 모델 기반의 음성 검출기)

  • Kim, Sang-Kyun;Chang, Joon-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.76-81
    • /
    • 2010
  • In this paper, we propose a novel approach to improve the performance of a statistical model-based voice activity detection (VAD) which is based on the second-order conditional maximum a posteriori (CMAP). In our approach, the VAD decision rule is expressed as the geometric mean of likelihood ratios (LRs) based on adapted threshold according to the speech presence probability conditioned on both the current observation and the speech activity decisions in the pervious two frames. Experimental results show that the proposed approach yields better results compared to the statistical model-based and the CMAP-based VAD using the LR test.

Correction of the Characteristic of Response of X-ray Detector Using Linear Modeling. (선형화 모델링을 이용한 디지털 X-선 검출기 반응 특성의 보정)

  • Park, Hyun-Sun;Jang, Seok-Hwan;Huh, Young;Kim, Whoi-Yul
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.539-542
    • /
    • 2001
  • 본 논문에서는 검출기의 반응 특성을 선형화 모델링 하여 정규화 할 수 있는 방법을 제안한다. 디지털 의료영상 시스템에서 X-선을 검출하는 검출기의 반응 특성이 모든 검출기마다 다르기 때문에 이 특성을 쉽고 빠르게 정규화 하는 방법이 필요하다. 본 논문에서는 균일한 피사체에 X-선 조사량의 비율을 다르게 하여 두 번 찍은 영상으로 검출기의 반응 특성을 정규화 한다. 실험 결과 일정한 두께의 납 평판에 조사량을 달리하여 촬영한 두 개의 결과 영상을 가지고 검출기의 반응 특성을 보정하면 매우 안정된 결과 영상을 얻을 수 있다.

  • PDF

Acoustic Echo Cancellation System using Narrow-Band Double Talk Detector (협대역 동시통화 검출기를 이용한 음향반향 제거 시스템)

  • Paek Sujin;Park Kyusik;Kim Kiman
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.213-216
    • /
    • 2002
  • 본 논문은 원거리 회의 시스템이나 차량 내 핸즈프리 통화 시 필연적으로 발생하는 음향 반향을 제거하기 위해 새로운 알고리즘을 제안한다. 본 논문에서 제안된 음향반향 제거 시스템은 Delayless 서브밴드 음향반향 제거기와 협대역 동시통화 검출기로 구성된다. Delayless Subband 적응 음향 반향 제거기는 적은 계산 량과 높은 수렴속도로 음향 반향 제거 성능이 뛰어난 것으로 알려져 있으며 본 논문은 이를 이용해 안정적인 음향 반향 제거를 위해서 협대역 Subband 내에서 동시통화 검출기를 구현한다. 기존의 광대역 동시 통화 검출기에 비해 본 논문에서 제안된 협대역 동시통화 검출기는 저주파 Subband 대역에서만 동시통화 검출을 수행하여 down-sampling으로 인한 계산 량 감소와 저주파 특성을 가지는 Subband 대역의 신호 특성으로 인한 신뢰성 있는 통화 상태 정보를 제공함으로서 전체적인 음향반향제어 시스템의 성능을 향상시킬 수 있도록 하였다. 본 연구에서 제안된 음향반향 제어 시스템의 성능은 다양한 컴퓨터 시뮬레이션을 통하여 입증하도록 한다.

  • PDF

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF

Partial IC Blind Multiuser Detection for CDMA Systems (CDMA 시스템을 위한 부분 간섭 제거 블라인드 다중 사용자 검출)

  • Woo Dae-Ho;Yoo Young-Gyo;Byun Youn-Shik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.184-190
    • /
    • 2006
  • In this paper, we propose the blind multiuser detector which is robust against the effects of near-far and multiuser interference. The proposed detector is composed of the partial IC(interference canceller) and the blind MOE(minimum output energy) multiuser detector. The partial IC partially eliminates interference components from the received signal then the output of partial IC is fed into the input of multiuser detector. Simulation results show that the proposed detector has the robust property but the performance of conventional MOE multiuser detector is rapidly degraded in case of existing both near far and multiuser. Thus, the proposed partial IC BMUD(blind multiuser detection) technique has better performance than the conventional MOE.

양자암호시스템을 위한 단일광자검출기

  • Lee, Min-Su;Kim, Yong-Su;Han, Sang-Uk;Mun, Seong-Uk
    • Information and Communications Magazine
    • /
    • v.32 no.8
    • /
    • pp.62-68
    • /
    • 2015
  • 본고에서는 차세대 보안통신 기술로 주목 받고 있는 양자암호시스템의 핵심 모듈인 단일광자 검출기의 최신 연구동향과 KIST 연구개발 내용에 대해 기술한다. 현재 상용화 수준으로까지 발전한 유선 양자암호 시스템에서는 성능, 소형화, 가격 등의 장점으로 인해 주로 InGaAs/InP avalanche photo diode (APD)를 이용한 단일광자검출기가 사용되고 있다. 유선 양자암호에서 사용하는 1550nm 통신 파장대의 단일광자가 갖는 에너지는 0.8 eV로 매우 미약한 수준이기 때문에 신호 검출을 위해 APD소자를 내부 증폭 이득이 무한대인 가이거모드(Geiger mode)에서 동작시킨다. 매우 높은 증폭비는 신호 검출뿐만 아니라 노이즈에도 동일하게 영향을 미치기 때문에 주변환경 노이즈에 의한 검출기 오동작 문제가 심각하게 발생한다. 따라서 단일광자검출기 구현에서 가장 중요한 기술은 소자 및 검출기 모듈에서 발생하는 노이즈의 영향을 최소화 시켜주는 것이다. 전세계적으로 검출기의 대표적인 노이즈인 after pulse를 저감 시키기 위한 연구가 매우 활발히 이루어지고 있는데 대표적으로 self-differencing, auxiliary signal, integrating, double balanced 등의 방법이 제시되고 있다. 본고에서는 각각의 최신 기술들에 대한 비교 분석 및 이를 바탕으로 현재 KIST에서 진행하고 있는 양자암호시스템을 위한 단일광자검출기 기술 개발에 대해 서술한다.

Ground based interferometric gravitational wave detector and its technologies

  • Park, June Gyu;Kim, Chang-Hee;Lee, Sungho;Kim, Yunjong;Seong, Hyeon Cheol;Jeong, Ueejeong;Je, Soonkyu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.60.1-60.1
    • /
    • 2021
  • 현재 중력파 관측은 레이저 간섭계 기반의 중력파 검출기를 통해 이루어지고 있고 검출기 성능이 개선되고 안정화 되어 초기 설계 사양 이상의 관측감도를 확보하였다. 이제 레이저 간섭계 기반의 중력파 관측 기술은 중력파 관측 가능성의 유무를 넘어 차세대 중력파 검출기의 건설을 앞당기는 수준이 되었으며 해외에서는 중력파 검출 기술을 선도하기 위한 공격적인 투자가 이루어 지고 있다. 이 발표에서는 현재 운영중인 레이저 간섭계 기반의 중력파 검출기의 중력파 검출 원리와 실제 중력파 검출기에서 사용되는 관련 핵심 기술들을 소개하고자 한다. 단순히 특정 분야의 일부 기술이 아닌 중력파 검출기 건설에 사용된 재료, 광학, 기계공학, 전자, 통신 등 다양한 분야의 기술을 소개하고 실제 중력파 검출기 관련 연구에 참여할 수 있는 연구 주제를 소개하고자 한다.

  • PDF

속도 검출기 없는 유도전동기의 고성능 all-digital drive system의 구현

  • 유호선;이상훈
    • ICROS
    • /
    • v.3 no.3
    • /
    • pp.36-48
    • /
    • 1997
  • 본 원고에서는 극 좌표계를 기준으로 하여 추정기를 구성함으로써 속도 검출기가 없는 유도전동기의 회전자 자속 및 회전 속도를 정확히 추정해 내고, 다시 이 정보를 이용하여 유도전동기를 고성능으로 제어할 수 있는 드라이브 시스템의 구현 과정과 이를 이용한 간단한 실험 결과에 대하여 소개하였다. 본 원고에서 제시한 몇가지의 실험 결과들은 소프트웨어의 알고리즘에 의하여 전동기의 회전축에 부착된 속도 검출기는 충분히 대치될 수 있음을 말해주는 것이므로, 속도 검출기가 가격과 내구성 등에서 실제적으로 산업 현장에 적용하기에 많은 문제점을 안고 있다는 점을 감안할 때 그 유용성을 입증하는 것이다.

  • PDF

A Study on the Germanium Radiation Detector Compensated by Gamma-ray Irradiation

  • Moon, P.S.
    • Nuclear Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.85-94
    • /
    • 1975
  • The n-type germanium crystals have been irradiated by $^{60}$ Co gamma-ray with 647 Mrad at room temperature for compensation. The Ge(${\gamma}$) detectors were fabricated from the gamma-ray irradiated germanium single crystals. The detector characteristics of the Ge (${\gamma}$) detectors were comparable to those of thin Ge(Li) detectors and high purity germanium detectors. The thermal stability of the Ge (${\gamma}$) detector showed a feasibility for ambient temperature storage.

  • PDF

A Real-Time Viola-Jones Object Detector using PSO with Tracking Method (Tracking 방식의 PSO를 이용한 실시간 Viola-Jones 물체 검출기)

  • Park, Byeong-Ju;Lee, Jae-Heung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.917-920
    • /
    • 2014
  • 본 논문에서는 SWO 방식의 물체 검출기를 개선하여 비디오 환경에 적합하며 실시간 처리가 가능한 Tracking 방식의 PSO 물체 검출기를 제안한다. PSO 방식 스캔은 각각의 입자들이 전역 최적 값으로 수렴하기 때문에 다중 검출에는 적지 않은데, 본 논문에서는 다중 물체를 검출하고 관리할 수 있도록 Tracking 개념을 적용하였다. 제안하는 방법을 적용하면 검출기의 오검출률을 줄이고 안정적인 검출 결과를 얻을 수 있으며 속도가 향상되어 실시간 처리가 가능하다. 논문에서 제안한 알고리즘을 적용해 본 결과 기존의 Viola-Jones 얼굴 검출기와 비교하여 검출률은 동일하면서 속도가 최대 21배 향상되었음을 확인하였다.