• Title/Summary/Keyword: 검사 결과

Search Result 16,659, Processing Time 0.052 seconds

Usability of Urinary Reagent Strips in Diagnosis of Meningitis (뇌수막염의 진단에서 뇨검사 시험지를 이용한 뇌척수액 검사의 유용성)

  • Jeong, Jin Yeong;Park, Sang Kyu
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.2
    • /
    • pp.265-270
    • /
    • 1997
  • Purpose: Rapid diagnosis and prompt treatment remain the cornerstone of management of patients with meningitis. Examination of cerebrospinal fluid(CSF) for glucose, protein, cells, and organisms is necessary for accurate diagnosis, but in many parts of the world facilities do not exist to do so. We tested CSF samples from 69 children with suspected meningitis with urinary reagent strips and analyzed the results to know the usability of urinary reagent strips in diagnosis of meningitis. Methods: 69 CSF samples obtained from children with suspected meningitis were analysed. Each sample was divided into two; one was sent to the laboratory for routine diagnostic evaluation, and the other was tested with the reagent strip(Combur10 Test M). Laboratory values of CSF glucose, protein, and leucocytes for each CSF sample were plotted against the corresponding reagent-strip category. Results: There was good agreement between the dipstick and laboratory values for CSF protein and cell count but not for glucose. Conclusion: Rapid diagnosis of meningitis could be made with three component of the Combur10 test strip. It is easy to do and would be of particular value to those working in parts of the world where no laboratory facilities exist.

  • PDF

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

The Degrees of Understanding and Utilization of Elementary School Teacher's Psychological Test (초등학교 교사의 심리검사 이해도와 활용도)

  • Gu, Yeong-Ha;Yeo, Tae-Chul
    • The Korean Journal of Elementary Counseling
    • /
    • v.11 no.1
    • /
    • pp.51-69
    • /
    • 2012
  • This research is a fundamental research to provide the foundation that psychological test can be utilized efficiently. It investigated and studied the reality of the psychological test used in elementary school, teacher's degrees of understanding and utilization of psychological test, requirements for improving the psychological test that is performed currently, and the direction of the testing tools that are required by elementary school. First, the main purpose of psychological test was different. The tests that were usually utilized in elementary schools were career inventory test and aptitude test, followed by personality test, learning test, creativity test and intelligence test in order. Second, it showed that teachers read the testing manual before carrying out the psychological test and understood it individually, the degree of understanding of T score showed to be the lowest. As a factor that hampered elementary school teacher's understanding of the psychological test, there was insufficiency of the teacher's professional knowledge, and it showed that the preparatory training for teachers about the tools of psychological test was necessary in order to improve this. Teacher's degree of utilization of psychological test showed to be lower than that of understanding. As a factor that influenced this kind of utilization by teachers, the lack of methodical understanding in afterwards guidance after the testing was the biggest factor. To increase the teacher's degree of utilization of psychological test, it was investigated that advice for more specific methods of guidance after the testing was necessary. Third, cross analysis was executed to find out if there was difference in the degree of understanding and utilization of psychological test according to whether a teacher completed the education course regarding counseling or not, and as a result, there was difference in the degree of understanding regarding some tests, but there was no difference found in the degree of utilization. Besides these, the point to be complemented in psychological test that was currently executed elementary schools and the direction of the testing tools that elementary schools require were investigated.

  • PDF

Clinical Characteristics and Comparison of the Various Methods Used for the Diagnosis of the New Influenza A Pandemic in Korea (한국에서의 2009 신종 인플루엔자 A의 임상양상과 다양한 진단 방법들의 비교)

  • Kwon, Min Jung;Lee, Chang Kyu;Roh, Kyoung Ho;Nam, Myung Hyun;Yoon, Soo Young;Lim, Chae Seung;Cho, Yun Jung;Kim, Young Kee;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 2011
  • Background: Laboratory diagnosis of new influenza A (H1N1) is crucial for managing patients and establishing control and prevention measures. We compared the diagnostic accuracies of the real time RT-PCR (rRT-PCR) test recommended for the confirmation of the new flu and the viral culture method used conventionally for viral disease with that of the rapid antigen test (RAT). Methods: We performed RAT, R-mix culture, and real-time PCR by using 861 respiratory samples collected from December 2009 to January 2010 and evaluated the abilities of these methods to detect new influenza A. The relationship among the positive rates of RAT, grades of culture, and the cycle threshold (Ct) values of rRT-PCR was also evaluated. Results: Of the 861 patients, 308 (35.8%) were diagnosed with new influenza A. The sensitivities, specificities, positive predictive values, and negative predictive values of the tests were respectively as follows: 59.7%, 99.5%, 98.4%, and 81.6% for RAT; 93.2%, 100%, 100%, and 96.3% for R-mix culture; and 95.8%, 100%, 100%, and 97.7% for rRT-PCR. Samples with weak positive grade in culture and those with Ct values of 30-37 in rRT-PCR showed positivities as low as 25.3% and 2.3% in RAT, respectively. The hospitalization rate and death rate of the confirmed patients were 3.2% and 0.3%, respectively, and gastrointestinal symptoms were observed in 7.2% of the patients. Conclusions: R-mix culture and rRT-PCR tests showed excellent reliability in the diagnosis of new influenza A and could be very useful, especially for samples with low viral load.

Evaluation of Radiation Exposure to Medical Staff except Nuclear Medicine Department (핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가)

  • Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 2016
  • Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.

  • PDF

Effective Dose Determination From CT Head & Neck Region (두경부(Head & Neck) CT 검사 시 장기의 유효선량 측정)

  • Yun, Jae-Hyeok;Lee, Kwang-Weon;Cho, Young-Ki;Choi, Ji-Won;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.105-116
    • /
    • 2011
  • In this study, we present the measurements of effective dose from CT of head & neck region. A series of dose measurements in anthropomorphic Rando phantom was conducted using a radio photoluminescent glass rod dosimeter to evaluate effective doses of organs of head and neck region from the patient. The experiments were performed with respect to four anatomic regions of head & neck: optic nerve, pons, cerebellum, and thyroid gland. The head & neck CT protocol was used in the single scan (Brain, 3D Facial, Temporal, Brain Angiography and 3D Cervical Spine) and the multiple scan (Brain+Brain Angiography, Brain+3D Facial, Brain+Temporal, Brain+3D Cervical spine, Brain+3D Facial+Temporal, Brain+3D Cervical Spine+Brain Angiography). The largest effective dose was measured at optic nerve in Brain CT and Brain Angiography. The largest effective dose was delivered to the thyroid grand in 3D faical CT and 3D cervical spine, and to the pons in Temporal CT. In multiple scans, the higher effective dose was measured in the thyroid grand in Brain+3D Facial, Brain+3D Cervical Spine, Brain+3D Facial+Temporal and Brain+3D Cervical Spine+Brain Angiography. In addition, the largest effective dose was delivered to the cerebellum in Brain CT+Brain Angiography CT and higher effective dose was delivered to the pons in Brain+Temporal CT. The results indicate that in multiple scan of Brain+3D Cervical Spine+Brain Angiography, effective dose was 2.52 mSv. This is significantly higher dose than the limitation of annual effective dose of 1 mSv. The effective dose to the optic nerve was 0.31 mSv in Brain CT, which shows a possibility of surpassing the limitation of 1 mSv by furthre examination. Therefore, special efforts should be made in clinical practice to reduce dose to the patients.

Six Sigma Analysis of Vitamin D Measurement Using External Quality Assessment Program (외부정도관리 프로그램을 이용한 비타민 D 검사의 6 시그마 분석)

  • Ji, Myungsuk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.2
    • /
    • pp.91-97
    • /
    • 2020
  • Standardization of vitamin analysis continues around the world, and much effort has been made to improve the accuracy of the results. This study analyzed the sigma metrics of the vitamin D test using the external quality assessment (EQA) program. Sigma metrics is used for quantitative tests performed in the laboratory, and the test results can be objectively visualized in terms of quality. This analysis was performed based on the accuracy of the College of American Pathologists (CAP) using the results of the 2019 accuracy-based vitamin D (ABVD) survey, and about 300 laboratories participated in the survey. Reference values were obtained by the Center for Disease Control and Prevention (CDC) reference laboratory. At six different concentrations, the sigma metrics were analyzed to be 1.00, 1.85, 2.42, 1.01, 1.54 and 0.78, respectively. An average of 1.43 sigma metrics was determined. In particular, only positive biases for ABVD-16 and 17 were shown in the liquid chromatography tandem-mass spectrometry (LC-MS/MS), which is the standard method for vitamin D determination when compared to the reference values. The causes of the difference can be explained by cross reactivity to various vitamin D metabolites. Laboratories need to improve their overall performance.

Effects of Consistency Criterion for Scoring on the Reliability and the Validity of Polygraph Test for Crime Suspects (범죄 용의자의 거짓말탐지검사의 신뢰도와 타당도에 대한 일관성 채점기준의 효과)

  • Han, Yu-Hwa;Jeong, Je-Young;Park, Kwang-Bai
    • Science of Emotion and Sensibility
    • /
    • v.12 no.4
    • /
    • pp.557-564
    • /
    • 2009
  • For scoring polygraph charts, the Prosecutors' Office of the Republic of Korea uses a consistency criterion in which an elevated signal on one physiological channel is scored as a deceptive response only if the signal is also elevated on other channels. In the current study, the effects of this scoring criterion on reliability and accuracy (validity) of polygraph scores were assessed. Polygraph tests on 26 suspects were evaluated twice by the same examiners. The examiners used the consistency criterion in the first evaluation. In the second evaluation, the examiners were prevented from using the criterion; the signals from each physiological channel were separated and randomly arranged before they were rescored by the same examiner. Reliability was assessed by the variation among the scores for each suspect. Accuracy was assessed by establishing a standard, based on a Latent Class Analysis model, using the results of polygraph tests on each of 182 additional suspects. Reliability and accuracy were both improved by the use of the consistency criterion which therefore was recommended.

  • PDF

Evaluation of Autonomic Neuropathy in Patients with Sleep Apnea Syndrome (수면 무호흡 증후군 환자에서 자율 신경 장애의 평가)

  • Lee, Hak-Jun;Park, Hye-Jung;Shin, Chang-Jin;Kim, Ki-Beom;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.404-415
    • /
    • 1998
  • Background: Sleep apnea syndrome, which occurs in 1~4 % of the adult population, frequently has different cardiovascular complications such as hypertension, ischemic heart disease, cardiac arrythmia as well as sleep-wake disorder such as excessive daytime hypersomnolence or insomnia. Mortality and vascular morbidity are reported to be significantly higher in sleep apnea syndrome patients than in normal population. According to the recent studies, autonomic dysfunction as well as hypoxemia, hypercapneic acidosis, and increased respiratory effort, may playa role in the high prevalence of cardiovascular complications in patients with sleep apnea syndrome. However the cause and mechanism of autonomic neuropathy in patients with sleep apnea syndrome are not well understood. We studied the existence of autonomic neuropathy in patients with sleep apnea syndrome and factors which influence the pathogenesis of autonomic neuropathy. Method: We used the cardiovascular autonomic neuropathy(CAN) test as a method for evaluation of autonomic neuropathy. The subjects of this study were 20 patients who diagnosed sleep apnea syndrome by polysomnography and 15 persons who were normal by polysomnography. Results: Body mass index and resting systolic blood pressure were higher in sleep apnea group than control group. Apnea index(Al), respiratory disturbance index(RDI) and snoring time percentage were significantly higher in sleep apnea group compared with control group. But there were no significant differences in saturation of oxygen and sleep efficiency in two groups. In the cardiac autonomic neuropathy test, the valsalva ratio was significantly low in sleep apnea group compared with control group but other tests had no differences between two groups. The CAN scores and corrected QT(QTc) interval were calculated significantly higher in sleep apnea group, but there were no significant correlations between CAN scores and QTc interval. There were no significant data of polysomnography to correlate to the CAN score. It meant that the autonomic neuropathy in patients with sleep apnea was affected by other multiple factors. Conclusion: The cardiovascular autonomic neuropathy test was a useful method for the evaluation of autonomic neuropathy in patients with sleep apnea syndrome and abnormalities of cardiovascular autonomic neuropathy were observed in patients with sleep apnea syndrome. However, we failed to define the factors that influence the pathogenesis of autonomic neuropathy of sleep apnea syndrome. This study warrants futher investigations in order to define the pathogenesis of autonomic neuropathy in patients with sleep apnea syndrome.

  • PDF

Unstable Data of HBe Antigen during Seroconversion from HBe Antigen to Antibody in Chronic Type B Hepatitis (만성B형 간염에서 HBe 항원에서 항체로의 혈청 전환 중에 불안정하게 나타나는 HBe 항원)

  • Shin, Sun-Young;Min, Gyeong-Sun;Noh, Kyung-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.78-81
    • /
    • 2008
  • Purpose: In this study, we evaluated unstable serum data of HBe antigen (HBeAg) or HBe antibody (HBeAb) in patients who experienced HBeAg seroconversion. This study have been performed to assist a medical technologist in the recognition of patients who were chronically infected with the hepatitis B virus (HBV). Materials and Methods: A total number of 3 patients were enrolled in this study. All patients experienced HBeAg seroconversion. Serum data of HBeAg and HBeAb were measured by radioimmunoassay. Results: The data of HBeAg or HBeAb showed an unstable change during seroconversion from HBeAg to HBeAb in chronic type B hepatitis (CBH). Conclusions: Serum data of HBeAg or HBeAb can change during HBe seroconversion. These data suggest that patients with HBe seroconversion can experience an unstable oscillation of HBeAg or HBeAb value from positive to negative. Unstable data can appear naturally due to the seroconversion process.

  • PDF