• 제목/요약/키워드: 검사주기

Search Result 694, Processing Time 0.026 seconds

Clinical Analysis of Acute Respiratory Tract Infections by Influenza Virus in Children (인플루엔자 바이러스에 의한 소아 급성 호흡기 감염증의 유행 및 임상 양상)

  • Kwon, Min Kyoung;Kim, Mi Ran;Park, Eun Young;Lee, Kon Hee;Yoon, Hae Sun;Kim, Kwang Nam;Lee, Kyu Man
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1519-1527
    • /
    • 2002
  • Purpose : Although influenza virus is one of the most important causes of acute respiratory tract infections(ARTIs) in children, virus isolation is not popular and there are only a few clinical studies on influenza in Korea. We evaluated the epidemiologic and clinical features of ARTIs by influenza virus in children. Methods : From February 1995 to August 2001, nasopharyngeal aspirations were obtained and cultured for the isolation of influenza virus in children admitted with ARTIs. The medical records of patients with influenza virus infection were reviewed retrospectively. Results : Respiratory viruses were isolated in 997(22.0%) out of 4,533 patients examined, and influenza virus was isolated in 164 cases(3.6%). Influenza virus was isolated year after year mainly from December to April of next year. The ratio of male and female was 1.9 : 1 with a median age of 15 months. The most common clinical diagnosis of influenza virus infection was pneumonia, and fever and cough developed in most patients. There was no difference between influenza A and B infection in clinical diagnoses and symptoms. All patients recovered without receiving antiviral treatment except for one patient diagnosed with pneumonia who had underlying disease of Down syndrome with ventricular septal defect. Conclusion : ARTIs caused by influenza virus developed every winter and spring during the period of study. Because fatal complication can develop in the high risk group, prevention, early diagnosis and proper management of influenza should be emphasized.

The Influence of Obstructive Sleep Apnea on Systemic Blood Pressure, Cardiac Rhythm and the Changes of Urinary (폐쇄성 수면 무호흡이 전신성 혈압, 심조율 및 요 Catecholamines 농도 변화에 미치는 영향)

  • Lo, Dae-Keun;Choi, Young-Mee;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.153-168
    • /
    • 1998
  • Background: The existing data indicate that obstructive sleep apnea syndrome contributes to the development of cardiovascular dysfunction such as systemic hypertension and cardiac arrhythmias, and the cardiovascular dysfunction has a major effect on high long-term mortality rate in obstructive sleep apnea syndrome patients. To a large extent the various studies have helped to clarify the pathophysiology of obstructive sleep apnea, but many basic questions still remain unanswered. Methods: In this study, the influence of obstructive sleep apnea on systemic blood pressure, cardiac rhythm and urinary catecholamines concentration was evaluated. Over-night polysomnography, 24-hour ambulatory blood pressure and ECG monitoring, and measurement of urinary catecholamines, norepinephrine (UNE) and epinephrine (UEP), during waking and sleep were undertaken in obstructive sleep apnea syndrome patients group (OSAS, n=29) and control group (Control, n=25). Results: 1) In OSAS and Control, UNE and UEP concentrations during sleep were significantly lower than during waking (P<0.01). In UNE concentrations during sleep, OSAS showed higher levels compare to Control (P<0.05). 2) In OSAS, there was a increasing tendency of the number of non-dipper of nocturnal blood pressure compare to Control (P=0.089). 3) In both group (n=54), mean systolic blood pressure during waking and sleep showed significant correlation with polysomnographic data including apnea index (AI), apnea-hypopnea index (AHI), arterial oxygen saturation nadir ($SaO_2$ nadir) and degree of oxygen desaturation (DOD). And UNE concentrations during sleep were correlated with AI, AHI, $SaO_2$ nadir, DOD and mean diastolic blood pressure during sleep. 4) In OSAS with AI>20 (n==14), there was a significant difference of heart rates before, during and after apneic events (P<0.01), and these changes of heart rates were correlated with the duration of apnea (P<0.01). The difference of heart rates between apneic and postapneic period (${\Delta}HR$) was significantly correlated with the difference of arterial oxygen saturation between before and after apneic event (${\Delta}SaO_2$) (r=0.223, P<0.001). 5) There was no significant difference in the incidence of cardiac arrhythmias between OSAS and Control In Control, the incidence of ventricular ectopy during sleep was significantly lower than during waking. But in OSAS, there was no difference between during waking and sleep. Conclusion : These results suggested that recurrent hypoxia and arousals from sleep in patients with obstructive sleep apnea syndrome may increase sympathetic nervous system activity, and recurrent hypoxia and increased sympathetic nervous system activity could contribute to the development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac function.

  • PDF

Effect of Cellulose Derivatives to Reduce the Oil Uptake of Deep Fat Fried Batter of Pork Cutlet (셀룰로오스 유도체가 돈가스 튀김옷의 흡유량 감소에 미치는 영향)

  • Kim, Byung-Sook;Lee, Young-Eun
    • Korean journal of food and cookery science
    • /
    • v.25 no.4
    • /
    • pp.488-495
    • /
    • 2009
  • Pork cutlet is a favorite deep fat fried food item among Korean children, and an excellent protein-containing food, and as well as a simple and economical cuisine. However, the frying process adds a significant amount of calories. We added MC (Methylcellulose) and HPMC (Hydroxypropyl Methylcellulose) to the batter in an effort to reduce oil uptake in prepared pork cutlets. After additions of MC and HPMC at concentrations of 0.5, 1, and 1.5% respectively, we assessed the viscosity of batter, color after frying, the increases in moisture retention and oil uptake, and sensory characteristics, comparing each quality. The viscosity of batter with 0.5% HPMC added (w/w) was similar to that of the controls, but the viscosity of all the batter with added MC was so much higher that it was difficult to use the batter for coating at the same temperature, leading to a failure even to prepare a sample. After frying, the batter with added HPMC provided significantly less oil uptake and more moisture retention than the batter to which MC was added. Additionally, with regard to color and sensory characteristics, the pork cutlet with 0.5% added HPMC was superior to the other samples. According to these results, we concluded that when cellulose derivatives are added in order to reduce oil uptake and to raise the moisture retention of the batter of pork cutlet, HPMC is more useful in this regard than MC. Additionally, the batter with 0.5% HPMC added appears to be the best of the tested choices, for three reasons: first, the viscosity of the batter is similar to that of the controls; second, the taste is not greasy after frying as the result of the reduced oil uptake and higher moisture retention; and third, the sensory characteristics of this sample, such as, color, crispiness, and hardness were the best among samples.

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.