• Title/Summary/Keyword: 검교정

Search Result 112, Processing Time 0.025 seconds

Partial Anomalous Pulmonary Venous Connection to the Superior Vena Cava

  • Lee, Sub;Kim, Han-Woong;Kang, Hyoung-Seok;Bae, Chi-Hoon;Jheon, Sang-Hoon;Kwon, Oh-Choon;Ahn, Wook-Su
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.672-679
    • /
    • 2001
  • Background: Surgical correction of partial anomalous pulmonary venous connection to the superior vena cava has been associated with postoperative venous obstruction and sinus node dysfunction. In this paper we describe our current approach and its short-term results. Material and Method: Between April 1999 and January 2000, 5 consecutive patients, ranging from 2 months to 66 years old, underwent corrective operation for partial anomalous pulmonary venous connection to the superior vena cava at Sejong General Hospital and Daegu Catholic University Medical Center. Surgical correction involved diversion of the pulmonary venous drainage to the left atrium using a right atrial flap(2 patients) or prosthetic patch(3 patients) with division of the superior vena cava superior to the restore site of the pulmonary veins and reimplantation on the right atrial appendage to restore systemic venous drainage. Result: All patients were discharged between postoperative day 9 and 15 without complications. One Russian boy returned to his country, therefore, he was lost to follow-up after discharge. Remaining 4 patients were asymptomatic and in normal regular sinus rhythm at a mean follow-up of 17.75$\pm$4.27 months. Follow-up echocardiographic study (range, 12 to 24 months) revealed no incidence of narrowing of the venous pathways or of residual shunt. Conclusion: Our current approach is relatively simple and reproducible in achieving unobstructive pulmonay venous and SVC pathways. By avoiding incision across the cavoatrial junction, surgical injury to the sinus node and its artery may be minimized. The presented surgical technique can be safely and effectively applied to the selected patients.

  • PDF

Effect of Visual Sensory Improvement by Amblyopia Treatment on Improvement of Ocular Functions (약시 치료에 의한 시감각 개선이 안기능 향상에 미치는 효과)

  • Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.551-555
    • /
    • 2014
  • Purpose: This study is to investigate if the improvement of visual sensory (VS) by amblyopia treatment affects the ocular functions in refractive errors, accommodative errors and phoria at distance and near. Methods: 10 subjects (17 eyes, mean age of $10.7{\pm}2.9$ years) who treated amblyopia completely, were participated for this study. Refractive errors, accommodative errors, and distance and near phoria were compared between before and after treatments of amblyopia. Refractive errors and accommodative errors at 40 cm were measured using openfield auto-refractor (NVision-5001, Shin Nippon, Japan) and using monocular estimated method (MEM) respectively. Phoria was determined at 3 m for distance and at 40 cm for near using Howell phoria card, cover test or Maddox rod. Results: Mean corrected visual acuity (CVA) significantly increased from $0.46{\pm}0.11$ (decimal notation) for before amblyopia treatment to a level of $1.03{\pm}0.13$ for after amblyopia treatment (p < 0.001). For spherical refractive error, hyperopia significantly decreased from $+2.29{\pm}0.86D$ to a level of $+1.1{\pm}2.38D$ (p < 0.05) but astigmatism did not significantly change; $-1.80{\pm}1.41D$ for before treatment and $-1.65{\pm}1.30D$D for after treatment (p > 0.05). Accommodative error significantly decreased from accommodative lag of $+1.1{\pm}0.75D$ to a level of $+0.5{\pm}0.59D$ (accommodative lag) (p < 0.05). Distance phoria significantly changed from eso $2.9{\pm}6.17PD$ (prism diopters) to a level of eso $0.2{\pm}3.49PD$ (p < 0.05), and near phoria also significantly changed from eso $0.4{\pm}2.32PD$ to level of exo $2{\pm}4.9PD$ (p < 0.05). There was a high correlation (r = 0.88, p < 0.001) between improvement of visual acuity and decrease of accommodative lag. Conclusions: Hyperopic refractive error decreased with improvement of CVA or VS by amblyopia treatment. And the improvement of VS by amblyopia treatment also improved accommodative error, and changed phoria coupled with accommodation.

Ultrasonographic study on the masseter muscle thickness of adult Korean (한국인 성인의 교근 두께에 관한 초음파검사적 연구)

  • Cha, Bong-Kuen;Park, In-Woo;Lee, Yeun-Hee
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.225-236
    • /
    • 2001
  • It is widely accepted that the shape and structure of bone are closely related to the activity of attached muscle. Numerous clinical and animal experimental studies indicated the significant effects of masticatory muscle function on maxillofacial morphology. Recently, the development of ultrasonography has spread throughout different fields of medicine. In the clinical examinations, ultrasonography is a convenient, inexpensive technique to apply with accurate and reliable results. The aim of this study is to assess the thickness of the masseter muscle and its correlation to maxillofacial skeleton by examining 35 male and 15 female dental students at Kangnung National University. The masseter muscle thickness of the subjects were measured by ultrasonographic scanning with a 7.5MHz linear probe, and their maxillofacial morphology were investigated by lateral cephalometric radiographs. The relationship between the masseter muscle thickness and maxillofacial morphology of normal adult was statistically analyzed, and the following results were obtained. 1. The average thickness of male masseter muscle was 13.8${\pm}$1.71mm in the relaxed state and 14.8${\pm}$1.77mm at maximal clenching state, while that of female was 11.6${\pm}$1.58mm and 12.4${\pm}$1.47mm, respectively. Ethnic difference in thickness of the masseter muscle and maxillofacial skeleton was found when the results of many researchers were compared with those of this study. 2. The thickness of the masseter muscle in both sexes increased significantly at maximal clenching state than in relaxed state(P<0.05). 3. The masseter muscle thickness of male was greater than that of female both in the relaxed state and maximal clenching states(P<0.05). 4. In males, the thickness of the masseter muscle was negatively correlated with the mandibular plane angle and positively correlated with the mandibular ramus height and anterior cranial base length(P<0.05). It may suggest that the male with thicker masseter muscle has smaller facial divergence. 5. No significant correlation was found between the masseter muscle thickness and maxillofacial morphology in females(P<0.05). Therefore, these data suggest that ultrasonography can add valuable information to the conventional examinations of masseter muscle function.

  • PDF

Evaluation of Radiation Exposure to Medical Staff except Nuclear Medicine Department (핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가)

  • Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 2016
  • Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.

  • PDF

Fate of Regurgitation of Left Atrioventricular Valve Following Repair of Atrioventricular Septal Defect (완전 방실중격결손증의 수술적 교정 후 잔존 좌측 방실판막부전에 대한 장기적 임상 경과 관찰)

  • 김시호;박한기;장병철;조범구;방정희;박영환
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.961-969
    • /
    • 2003
  • The purpose of this study was to evaluate the fate of left atrioventricular valve regurgitation(LAVVR) following repair of complete atrioventricular septal defects (AVSDs). Material and Method: Between July 1984 and March 2002, repair of complete AV defects were performed in 77 patients. Mean age at surgery was 30.23$\pm$69.11 months (range 1 to 456). Echocardiograms of all survivors after isolated AVSDs correction were reviewed. LAVVR were evaluated with color doppler echocardiography in 64 survival periodically. On each study, LAVVR severity was graded on a 1 to 4 scale, based upon the size of the regurgitated jet. Result: Mild deterioration of LAVV function was fairly common. LAVVR severity increased by >1 grade in 19 patients (30.2%) during the course of the study. However, the deterioration in LAVVR function occurred primarily between 12 and 24 months postoperatively. After the initial 24 postoperative months, LAVVR worsened on only 8 occasions and in each instance worsened by only 1 grade. Deterioration more than 3+ LAVVR occurred in only 3 patients. And deterioration to 4+ LAVVR was not observed after the initial 24 postoperative months but one. Survival curve analysis predicted a 88.2% of ten-year freedom rate from development of 4+ LAVVR after initial operation of complete AVSDs. Conclusion: Postoperative LAVVR remains fairly stable following AVSDs repair, Serious deterioration is rare after 24 postoperative months, especially after the initial 48 postoperative months. But serial follow-up study with echocariogram was need till 24 postoperative months after repair of complete AVSDs.

Prevalence and Risk Factors of Vancomycin-Resistant Enterococci (VRE) Colonization in Neonates (신생아에서 Vancomycin 내성 장구균의 감시 및 위험인자 분석)

  • Lee, Hwa Yun;Kim, Gi Hwan;Choi, Jin Su;Kim, Sun Hee;Choi, Young Youn;Hwang, Tai Ju
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.946-952
    • /
    • 2005
  • Purpose : Vancomycin-resistant enterococci(VRE) are now nosocomial pathogens in Korea. But little is known about the prevalence of stool colonization with VRE in neonates in Korea. So we studied the prevalence and risk factors of VRE colonization in the Neonatal Intensive Care Unit(NICU). Methods : From January 2000 to December 2004, the medical records of 294 neonates(127 cases of VRE group and 167 cases of non-VRE group, according to the results of stool culture) were reviewed retrospectively. We studied the annual prevalence of VRE and risk factors of VRE colonization in neonates. Results : From 2000 to 2003, the prevalence rate of VRE in NICU increased. After preventing VRE transmission, the prevalence rate of VRE has decreased. Conclusion : VRE colonization increased recently. Risk factors of VRE colonization were prematurity, lower birth weight, longer hospitalization and use of vancomycin or 3rd generation cephalosporin, compared with the non-VRE group. To prevent VRE transmission among newborns, aggressive infection control strategies by NICU staffs must be implemented immediately for all babies.

Respiratory air flow transducer calibration technique for forced vital capacity test (노력성 폐활량검사시 호흡기류센서의 보정기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Jang, Jong-Chan;Kim, Seong-Sik;Lee, Su-Ok;Jung, Jae-Kwan;Park, Kyung-Soon;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1082-1090
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is a very important diagnostic parameter obtained from the forced vital capacity(FVC) test. The expiratory flow rate increases during the short initial time period and may cause measurement error in PEF particularly due to non-ideal dynamic characteristic of the transducer. The present study evaluated the initial rise slope($S_r$) on the flow rate signal to compensate the transducer output data. The 26 standard signals recommended by the American Thoracic Society(ATS) were generated and flown through the velocity-type respiratory air flow transducer with simultaneously acquiring the transducer output signal. Most PEF and the corresponding output($N_{PEF}$) were well fitted into a quadratic equation with a high enough correlation coefficient of 0.9997. But only two(ATS#2 and 26) signals resulted significant deviation of $N_{PEF}$ with relative errors>10%. The relationship between the relative error in $N_{PEF}$ and $S_r$ was found to be linear, based on which $N_{PEF}$ data were compensated. As a result, the 99% confidence interval of PEF error was turned out to be approximately 2.5%, which was less than a quarter of the upper limit of 10% recommended by ATS. Therefore, the present compensation technique was proved to be very accurate, complying the international standards of ATS, which would be useful to calibrate respiratory air flow transducers.

A Study on the Change of Materials and Fabrication Techniques of Stone Figures in Royal Tombs of the Joseon Period - Focusing on Shindobi, Pyo-Seok, and Sang-Seok - (조선시대 왕릉 석물의 재료와 제작 방법 변화에 관한 연구 - 신도비와 표석, 상석을 중심으로 -)

  • Cha, Moonsung
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.56-77
    • /
    • 2019
  • Bi-Seok is a treasure trove of funeral rites and an important cultural asset that can shed light on the historical and social history of calligraphy, but research of the topic is still insignificant. In particular, research on the production method of Bi-Seok remains an unproven field. The production of Bi-Seok can be roughly divided into ma-jeong (refining stone), sculpture, and the Buk-chil (process of engraving letters) process. This article reveals some facts: First, performing ma-jeong to the Sang-Seok, Honyu-Seok, Bi-seok, which are known to be God's things. This process is needed because of the change in the perception of the Honyu-Seok due to the settlement and propagation of Confucian ceremonial rituals in the times of hardship in 1592 and 1636. As the crafting process of ma-jeong did not remain concrete, it was only possible to examine the manufacturing process of Bi-Seok through its materials and tools. Second, the rapid proliferation of Oh-Seok and Sa-jeo-chwi-yong (purchase of things made by private citizens) in the Yeongjo era has great importance in social and cultural history. When the Gang-Hwa-Seok of the commodity were exhausted, the Oh-Seok that was used by Sadebu (upper civil class) were used in the tomb of Jangneung, which made Oh-Seok popular among people. In particular, the use of Oh-Seok and the Ma-Jeong process could minimize chemical and physical damage. Third, the writing method of the Bi-seok is Buk-chil. After Buk-Chil of Song Si-Yeol was used on King Hyojong's tomb, the Buk-Chil process ( printing the letters on the back of the stone and rubbing them to make letters) became the most popular method in Korea and among other East Asian countries, and the fact that it was institutionalized to this scale was quite impressive. Buk-Chil became more sophisticated by using red ink rather than black ink due to the black color that results from Oh-Seok. Fourth, the writing method changes in the late Joseon Dynasty. Until the time of Yeongjo's regime, when inscribing, the depth of the angle was based on the thickness of the stroke, thus representing the shade. This technique, of course, did not occur at every Pyo-Seok or Shindobi, but was maintained by outstanding artisans belonging to government agencies. Therefore, in order to manufacture Bi-Seok, Suk-seok, YeonJeong, Ma-jeong, Jeong-Gan, ChodoSeoIp, Jung-Cho, Ip-gak, Gyo-Jeong, and Jang-Hwang, a process was needed to make one final product. Although all of these methods serve the same purpose of paying respects and propagandizing the great work of deceased persons, through this analysis, it was possible to see the whole process of Pyo-Seok based upon the division of techniques and the collaboration of the craftsmen.

Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters (유량측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Lee, Suk-Ho;Jung, Sung-Won;Kim, Tae-Woong
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. However, it needs lots of time and money to get the discharge data. So discharge rating curve is usually used in converting discharge data. Therefore reliability of discharge rating curve absolutely depends on quality of discharge data. Many engineers who study hydrologic engineering make high quality discharge data to develop reliable discharge rating curve. And they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and experimental research data from measurement are not enough. In this paper, constant discharge flowed through standard concrete channel, and the velocity is measured using various flow meters. Also Discharge is calculated by measured data to compare and analyze. The equipment for the experiment is Price AA(USGS Type AA Current meter), flow meter, ADC, C2 small current meter, flow tracker, Electromagnetic current meter. The discharge got form various flow meters which are widely used for discharge measurement. The various depths of water were examined and compared such as 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m. The experiment progresses a round-measurement on 6-case. Wading measurement(one point method : the 60 % height in surface of the water) was applied to improve creditability and accuracy among measurement methods. USGS Type AA current Meter, Flow Meter, ADC, C2 Small Current meter got the certificate of quality guaranteed. So the results of experiment were used to compare discharge. The Results showed the difference based on USGS Type AA current Meter at average discharge and velocity. Electromagnetic current meter made differences over $\pm$ 10 % and Flow Meter made differences under $\pm$ 10 %. Also ADC, Flow Meter, C2 Small Current meter made differences under $\pm$ 5 %.

A Comparative Study on Quantifying Uncertainty of Vitamin A Determination in Infant Formula by HPLC (HPLC에 의한 조제분유 중 비타민 A 함량 분석의 측정불확도 비교산정)

  • Lee, Hong-Min;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.152-159
    • /
    • 2008
  • The purpose of this study was to determine the accurate quantification of vitamin A in infant formula by comparing two different standard stock solutions as well as various sample weights using high performance liquid chromatography. The sources of uncertainty in measurement, such as sample weight, final smaple vloume, and the instrumental results, were identified and used as parameters to determine the combined standard uncertainty based on GUM(guide to the expression of uncertainty in measurement) and the Draft EURACHEM/CITAC Guide. The uncertainty components in measuring were identified as standard weight, purity, molecular weight, dilution of the standard solution, calibration curve, recovery, reproducibility, sample weight, and final sample volume. Each uncertainty component was evaluated for type A and type B and included to calculate the combined uncertainty. The analytical results and combined standard uncertainties of vitamin A according to the two different methods of stock solution preparation were 627 ${\pm}$ 33 ${\mu}$g R.E./100 g for 1,000 mg/L of stock solution, and 627 ${\pm}$ 49 ${\mu}$g R.E./100 g for 100 mg/L of stock solution. The analytical results and combined standard uncertainties of vitamin A according to the various sample weighs were 622 ${\pm}$ 48 ${\mu}$g R.E./100 g, 627 ${\pm}$ 33 ${\mu}$g R.E./100 g, and 491 ${\pm}$ 23 ${\mu}$g R.E./100 g for 1 g, 2 g, and 5 g of sampling, respectively. These data indicate that the preparation method of standard stock solution and the smaple amount were main sources of uncertainty in the analysis results for vitamin A. Preparing 1,000 mg/L of stock solution for standard material sampling rather than 100 mg, and sampling not more than 2 g of infant formula, would be effective for reducing differences in the results as well as uncertainty.