• Title/Summary/Keyword: 건축표준설계기준

Search Result 53, Processing Time 0.025 seconds

An Academic Assessment of Lightweight Concrete Properties for Rhamen-type Modular Building Walls (라멘식 모듈러 건축물 벽체 적용을 위한 경량 콘크리트의 공학적 특성)

  • Jung, Ui-In;Lee, Min-Jae;Ju, Young-Gil;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.5
    • /
    • pp.527-536
    • /
    • 2023
  • This research embarked on a comprehensive examination of the engineering characteristics of lightweight concrete intended for implementation in rhamen-type modular building walls. The concrete was formulated utilizing bottom ash and coated EPS beads, in accordance with the Korea Construction Standards Center(KCS) 14 20 20 "Lightweight Aggregate Concrete". Our findings articulate that while EPS beads tend to diminish the compressive strength of the lightweight concrete, they concurrently contribute to a notable reduction in unit mass. The porous nature of the bottom ash endows the material with diminished thermal conductivity. Significantly, a mixture containing 50% EPS beads and 50% BA20 aggregates, replacing half of the coarse aggregates, was found to meet the standard specifications.

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

Analysis of Characteristics of Horizontal Response Spectrum of Velocity Ground Motions from 5 Macro Earthquakes (5개 중규모 지진의 속도 관측자료를 이용한 수평 응답스펙트럼 특성 분석)

  • Kim, Jun-Kyoung
    • Tunnel and Underground Space
    • /
    • v.21 no.6
    • /
    • pp.471-479
    • /
    • 2011
  • The velocity horizontal response spectra using the observed ground motions from the recent 5 macro earthquakes, equal to or larger than 4.8 in magnitude, around Korean Peninsula were analysed and then were compared to the acceleration horizontal response spectra, seismic design response spectra (Reg Guide 1.60), applied to the domestic nuclear power plants, and finally the Korean Standard Design Response Spectrum for general structures and buildings. 102 velocity horizontal ground motions, including NS and EW components, were used for velocity horizontal response spectra and then normalized with respect to the peak velocity value of each ground motion. First, the results showed that velocity horizontal response spectra have larger values at the range of medium natural period, but acceleration horizontal response spectra have larger values at the range of short natural periods. Secondly, the results also showed that velocity horizontal response spectra exceed Reg. Guide 1.60 for longer natural periods bands less than 6-7 Hz. Finally, the results were also compared to the Korean Standard Response Spectrum for the 3 different soil types(SC, SD, and SE soil type) and showed that velocity horizontal response spectra revealed much higher values for the frequency bands below 1.5(SC), 2.0(SD), and 3.0(SE) seconds, respectively, than the Korean Standard Response Spectrum. The results suggest that the fact that acceleration, velocity, and displacement horizontal response spectra have larger values at the range of short, medium, and long natural periods, respectively, can be applied consistently to those form domestic ground motion, especially, the velocity ground motion. Information on response spectrum at such medium range periods can be very important since the domestic design of buildings and structures emphasizes recently medium and long natural periods than short one due to increased super high-rise buildings.

A Study of the Architectural Planning of the recently built Independent Public Kindergarten (최근 건립된 공립 단설유치원의 건축계획에 관한 연구)

  • Heo, Byung-Lee;Seo, Sang-Hyun
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • Establishing public kindergarten is very important in social welfare aspects. So far almost public kindergarten were built up as attached style in primary school. More independent style kindergarten is being requested for small land area, shorter commuting distance. But the standard design guideline of the independent public kindergarten is insufficient. The purpose of this study is to examine the architectural Planning direction for the standard design guideline of the independent public kindergarten. A result of this study can be suggested what kind of architectural Planning direction of independent public kindergarten is needed more acutely.

Analysis of Characteristics of Horizontal Response Spectrum of Ground Motions from Fukuoka Earthquakes Series (Fukuoka 연속 지진의 관측자료를 이용한 수평 응답스펙트럼 특성 분석)

  • Kim, Jun Kyoung
    • Tunnel and Underground Space
    • /
    • v.24 no.5
    • /
    • pp.354-365
    • /
    • 2014
  • The horizontal response spectra using the observed ground motions from 15 Fukuoka earthquake series, including main earthquake (2005/03/20; Mw=6.5), were analysed and then were compared to both the seismic design response spectra (Regulatory Guide 1.60), applied to the domestic nuclear power plants, and the Korean Standard Design Response Spectrum for general structures and buildings (1997). 178 horizontal ground motions, without considering soil types, were used for normalization with respect to the peak acceleration value of each ground motion. The results showed that response spectrum have strong dependency on epicentral distance. The results also showed that the horizontal response spectra revealed higher values for frequency bands at two frequency bands (about 8 - 10 and 16- 20 Hz) than Regulatory Guide 1.60. The results were also compared to the Korean Standard Building Design Spectrum for the 3 different soil types and showed that thehorizontal response spectra revealed higher values for almost all period bands than the Korean Standard Response Spectrum (500 yrs; Return Period; Seismic province 1; SE soil conditions). Through the qualitative improvements and quantitative enhancement of the observed ground motions, the diversity of the observed ground motions should be considered more significantly to improve the certainty of response spectrum.

A Study on Normal Project Duration for Water Resource Project (수자원시설 건설공사 표준공기 산정을 위한 기초연구)

  • Lee, Bongsu;Kim, Kinam;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2015
  • It is important to have enough design and construction duration for infrastructure projects. However, recent water resource project in Korea shows several problems caused by their fast-tract schedule. National Audit Committee report several water resource projects have quality problems caused by insufficient project duration. Especially, water resource projects such as dam and water pipeline construction should have proper time to secure their structure quality. Normal project duration for these projects should be estimated based on previous similar projects' historical data analysis. However there is no standard model which can estimate normal project duration for water resource projects in Korea. There are several normal project duration estimation models for building project developed by public(LH) and private construction companies. However, there is no proper model for water resource projects. So, this study developed normal project duration model for dam and water pipeline projects using historical data and show application of models.

A Study on the Development of China's Barrier-free Design Standards (중국 무장애 디자인 규범의 발전과정에 관한 연구)

  • LI, YUHONG;Lee, Jong-Kuk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.1
    • /
    • pp.17-26
    • /
    • 2019
  • Barrier-free design reflects the attention of the disadvantaged groups. As a populous country with the largest population and the largest number of elderly people, China has made great progress in the field of the Barrier-free. The scope of this thesis is from the 1980s to 2012 in China, studying the development process of China's barrier-free design standards by comparing the two barrier-free design standards implemented in the history of such design. In this paper, the two standards are compared and analyzed in the following aspects, which are the numbering, chapters, scope of application, applicable objects and purposes, and so on. Compared with the 2001 barrier-free design standards, the 2012 one can be concluded that the development of barrier-free design in China has been accelerated, the scope of application has been widened than before, the content has been supplemented, and restrictions on terms have been reduced.

A study on the Composition of the Production Rates System to Prepare Standards for Calculating the Construction Cost of PC Structure Apartments Based on Off-Site Construction (OSC) (OSC 기반 PC구조 공동주택 공사비 산정기준 마련을 위한 품셈 체계 구성에 관한 연구)

  • Lee, Hansoo;Lee, Chiho;Lee, Jeongwook;Noh, Hyunseok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.6
    • /
    • pp.96-106
    • /
    • 2021
  • The PC structure based on the OSC (Off-Site Construction) is mentioned as a representative method of innovation in the construction industry that converts the existing construction environment from site-centered to factory production-transportation-site assembly. However, recent research on PC method has focused on improving the functions of subsidiary materials and improving the production system to increase productivity and institutional / policy R&D that can be universally applied to the life-cycle stage of ordering / design /construction is insufficient. In particular, the absence of standardized cost calculation standards makes it difficult to calculate and verify of objectified appropriate construction cost. So which is an obstacle to the activation of the PC method. In this study, the standards for construction costs of domestic and foreign PC method were surveyed and similar Construction Standard Production Rates were analyzed to confirm the product structure suitable for PC method. Subsequently, the construction procedures and input resources for each PC subsidiary materials were identified through on-site surveys to derive component for subsidiary materials, and the factors of change in the product according to the construction characteristics(height, weight of subsidiary material) were verified. As a result the standard product calculation system suitable for the site installation of the PC method for apartment was presented.

A Study on Introduction to Performance based Design of Sprinkler Installation on Risk Level for Individual Occupancy in Korea (공간용도별 위험등급기반의 스프링클러헤드 성능 설계기법의 국내적용 연구)

  • Lee, Young-Jae;Park, Hyung-Joo
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.1-10
    • /
    • 2012
  • While a performance based sprinkler design method has been widely used in UK and USA according to fire hazards of occupancies, Korean fire safety industry could not yet accept it due to nonstandardization on risk level of various occupancy. Even only two or three spray pattern sprinkler was produced in Korea fire safety industry, therefore, various spray pattern sprinklers have not yet introduced to major occupancies. Spray pattern sprinklers with one of two K value have been used in all occupancies in Korea Market. UK and USA's Fire industry should produced the spray sprinklers with various K-factors and protection area due to performance based sprinkler design requirement. Therefore the fire load density for main occupancies has been investigated in order to compare with installation standard in advanced countries. Eventually a lot of variations in orifice and K factors of standard heads were set up including special heads needed for high hazard areas such as large drop type, enlarged orifice type and early suppression fast response.

A Study on the Application of BIPV for the Spread of Zero Energy Building (제로에너지 건축물 확산을 위한 건물 일체형 태양광 적용방안 연구)

  • Park, Seung-Joon;Jeon, Hyun-Woo;Lee, Seung-Joon;Oh, Choong-Hyun
    • Journal of Digital Convergence
    • /
    • v.19 no.9
    • /
    • pp.189-199
    • /
    • 2021
  • In order to increase the self-reliance rate of new and renewable energy in order to respond to the mandatory domestic zero-energy buildings, the taller the building, the more limited the site area, and installing PV modules on the roof is not enough. Therefore, BIPV (Building integrated photovoltaic, hereinafter BIPV) is the industry receiving the most attention as a core energy source that can realize zero-energy buildings. Therefore, this study conducted a survey on the problems of the BIPV industry in a self-discussing method for experts with more than 10 years of experience of designers, builders, product manufacturers, and maintainers in order to suggest the right direction and revitalize the BIPV industry. Industrial problems of BIPV adjustment are drawn extention range of standard and certification for products, range improvement for current small condition of various kind productions, need to revise standards for capable of accomodating roof-type, color-module and louver-module, necessary of barrier in flow of foreign modules into korea through domestic certification mandatory, difficulty in obtaining BIPV information, request to prevent confusion among participants by exact guidelime about architectural application part of BIPV, and lack of the BIPV definition clearness, support policy, etc. Based on the improvements needed for the elements, giving change and competitiveness impacts aims to present and propose counter measures and direction.