• 제목/요약/키워드: 건축물 화재

검색결과 688건 처리시간 0.646초

Establishment of Integrated Design Bases Management System of APR1400 Using BIM based Algorithm (BIM기반 Algorithm을 활용한 APR1400 설계기준 통합관리 체계 구축)

  • Shin, Jaeseop;Choi, Jaepil
    • Korean Journal of Construction Engineering and Management
    • /
    • 제20권5호
    • /
    • pp.52-60
    • /
    • 2019
  • The APR1400 is a 1400MWe nuclear power plant developed through national technology development project over a period about 10years. Approximately 65,000 design drawings are produced for APR1400 construction. In order to maintain consistency among numerous drawings, the highest level of design bases drawings (DBDs) are created according to design bases and this is used in the subsequent design. However, DBDs are produced and managed on a document basis and they are managed various field, it was difficult to accurately reflect the design bases information in the subsequent design. Therefore, this study recognizes limitations of the document based DBDs and develops a system that can accurately reflect the design bases information to subsequent design by adopting BIM based design bases integrated information system. Especially, by introducing DBIL(Design Bases Information Layer) concept, DBIL was created and analyzed based on five design bases(Physical protection, Fire protection, Internal missile protection, Internal flood protection, Radiation protection) applied to APR1400. In the final result DBIL set and Datasheet are integrated of room, design bases information, building data(wall, slab, door, window, penetrations). So it can be used for subsequent design automation and design verification. Furthermore, it is expected that APR1400 DBILs data can be used extensively in constructability and design economics analysis through comparison with next generation nuclear power plant.

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • 제9권4호
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.

A Study on the Usage of Miào(廟) and Gōng(宮) in Zhou Dynasty through the Mentions to Them in the Scripture Sentences of 『Chūn-qiū(春秋)』 - In the Process of Investigating the Existence of Zhou Dynasty's System to Regulate the Number of Zōng-miào(宗廟) 【1/2】 (『춘추』 경문에서의 묘(廟)·궁(宮) 언급을 통한 주대(周代)의 그 쓰임 사례 일고찰 - 주대의 묘수제(廟數制) 실재 여부에 대한 궁구 과정에서 【1/2】-)

  • Seo, Jeong-Hwa
    • The Journal of Korean Philosophical History
    • /
    • 제57호
    • /
    • pp.57-90
    • /
    • 2018
  • In this discussion, as a way to verify the existence of the system to regulate Zhou dynasty's $z{\bar{o}}ng-mi{\grave{a}}o$(宗廟) numbers, the discussion was focused on '$mi{\grave{a}}o$ (廟)' and '$g{\bar{o}}ng$(宮)' in the records of "$Ch{\bar{u}}n-qi{\bar{u}}$(春秋)". As for the parts where the contents of scripture sentences were not specific, the context of the case was investigated through the writings in "$Zu{\breve{o}}-zhu{\grave{a}}n$(左傳)" and other materials. In the cases of the usage of the letter, '$mi{\grave{a}}o$(廟 : a ruler's house, a nation's royal court)', in the scripture sentences in "$Ch{\bar{u}}n-qi{\bar{u}}$(春秋)", the followings need to be noticed. In $t{\grave{a}}i-mi{\grave{a}}o$(太廟) of State $L{\check{u}}$(魯), nationwide events and a ruler's political ancestral rite, $d{\grave{i}}$(?) ritual, were performed, and fancy tools for ancestral rites used in those rituals were equipped. As for the $z{\bar{o}}ng-mi{\grave{a}}o$(宗廟) of a ruler of those times, a ritual of royal court, $ch{\acute{a}}o$(朝) rite, was performed. The usage case of the letter, '$g{\bar{o}}ng$(宮 : house)', is as the following. In $g{\bar{o}}ng$(宮) where a ruler's personal family lived was a family ancestral rite for them carried out. The record about the ornate decorating for the $hu{\acute{a}}n-g{\bar{o}}ng$ house(桓宮), which can be said to have been the political base of $s{\bar{a}}n-hu{\acute{a}}n-sh{\grave{i}}$(三桓氏), three politically noble families of State $L{\check{u}}$(魯), is outstanding. The $x{\bar{i}}-g{\bar{o}}ng$ house(西宮) during $X{\bar{i}}-g{\bar{o}}ng$(魯 僖公)'s reign and a $x{\bar{i}}n-g{\bar{o}}ng$ house(新宮 : a newly built house) destroyed by fire at the third year of $Ch{\acute{e}}ng-g{\bar{o}}ng$(魯 成公), are assumed to have been a ruler's another house, such as the $ch{\check{u}}-g{\bar{o}}ng$ house(楚宮) in which $Xi{\bar{a}}ng-g{\bar{o}}ng$(魯 襄公) used to enjoy staying, which is different from the viewpoint that it might be a $m{\acute{i}}-g{\bar{o}}ng$ shrine(?宮 : a house constructed as a shrine for the deceased father or the deceased grand father) that had been formed since Han dynasty. It has been discussed that, regarding the records that the '$w{\check{u}}-g{\bar{o}}ng$ house(武宮) was built' and that the '$y{\acute{a}}ng-g{\bar{o}}ng$ house(煬宮) was built', certain buildings were established with the symbols of '$w{\check{u}}$(武 : martial arts and force of arms)' and '$y{\acute{a}}ng$(煬 : to burn and get rid of everything)', and the events that a lord stood as its lord continued. Therefore, its main goal was not the performance of a dutiful ancestral rite by a ruler of those times for deceased rulers, for instance, $W{\check{u}}-g{\bar{o}}ng$(魯 武公) or $Y{\acute{a}}ng-g{\bar{o}}ng$(魯 煬公), but display of certain political symbolism through the ritual. This symbolism is most obvious with the $hu{\acute{a}}n-g{\bar{o}}ng$ house(桓宮) and the $x{\bar{i}}-g{\bar{o}}ng$ house(僖宮). As a consequence, all $mi{\grave{a}}os$(廟) and $g{\bar{o}}ngs$(宮) in scripture sentences had the functions of a shrine in some part, but it has been verified that they were not the buildings set up as a shrine to follow '$z{\bar{o}}ng-mi{\grave{a}}o$(宗廟)'s number regulation system' of '$ti{\bar{a}}nz{\check{i}}-7-mi{\grave{a}}o$(天子七廟 : an emperor owns seven $mi{\grave{a}}os$(廟))' or '$zh{\bar{u}}h{\acute{o}}u-5-mi{\grave{a}}o$(諸侯五廟 : a lord owns five $mi{\grave{a}}os$(廟))'.

Compressive Properties of Ultra High Strength Concrete Exposed to High Temperature (고온에 노출된 초고강도 콘크리트의 압축특성)

  • Kang, Yong-Hak;Kang, Choong-Hyun;Choi, Hyun-Guk;Shin, Hyun-Jun;Kim, Wha-Jung
    • Journal of the Korea Concrete Institute
    • /
    • 제26권3호
    • /
    • pp.377-384
    • /
    • 2014
  • Recently, the trend toward larger architectural structures continues and accelerates demand for Ultra High Strength Concrete (UHSC) which satisfies structural performance. However, UHSC has weakness in fire and the performance tests are required. In this paper, the change of mechanical properties of 100 MPa grade UHSC exposed to high temperatures ($20^{\circ}C{\sim}800^{\circ}C$) was observed to develop high temperature material model of UHSC: residual compressive strength, modulus of elasticity, property of stress-strain on monotonous loading and property of stress-strain on cyclic loading. In addition, TG/DTA and SEM Images analyses were performed to investigate chemical and physical characteristics of UHSC, and the results of this research were compared with those of previous studies. As a result, UHSC at the heating temperature of $300^{\circ}C$ showed a sharp decrease of residual compressive strength and modulus of elasticity. And It was shown that UHSC had a plastic behavior at more than $400^{\circ}C$ on the cyclic loading and revealed a same tendency in both monotonous and cyclic loading of all heating temperatures. In addition, through TG/DTA and SEM images analyses compared with those from previous studies, it was shown that the deterioration of concrete inner tissue, water evaporation and chemical reaction caused the decrease of residual compressive strength and modulus of elasticity.

A Study on the Location and Spatial Organization Characteristics of the Royal Tombs Uireung (의릉(懿陵) 일원(一圓)의 입지(立地)와 공간구성특성(空間構成特性)에 관(關)한 연구(硏究))

  • Choi, Jong Hee;Kim, Heung Nyeon;Lee, Won;Eom, Tae Geon
    • Korean Journal of Heritage: History & Science
    • /
    • 제43권1호
    • /
    • pp.212-235
    • /
    • 2010
  • The purpose of this study is to examine the characteristics of the location and the spatial composition of Uireung that is located in Seokgwan-dong, Seongbuk-gu, Seoul, in order to understand the landscape architectural characteristics. The results are as follows. First, Uireung is 6.4km from Changdeokgung Palace and 5.5km from Heunginjimun Gate. It did not violate the distance standard (40km) for the royal tombs according to Joseon Dynasty Neung-won Myo-je. Second, Uireung is in harmony with the nature and shows the authoritative characteristics of the royal authority through the spatial composition and rank(Entrance Area, Ceremonial Area, Burial Area). Third, there are burial mound, stone sheep, stone tiger, stone table, stone watch pillars in the upper platform, and stone civil official, stone horse, stone lantern in the middle platform, and stone military official, stone horse in the lower platform, and T-shape shrine, worship road in the ceremonial area. There is no pond and a tomb keeper residence, but the position, size, and form can be approximated through historical research materials. There are a colony of pine trees around the burial mound and 64 species of trees such as pine tree, zelcova tree, and fir tree below the burial mound.

A Basic Study on the Evaluation Index of the Crime Prevention through Environmental Design of Wooden Cultural Buildings (목조 건축문화재의 범죄예방환경설계 평가지표에 대한 기초연구)

  • Kim, Choong-sik
    • Korean Journal of Heritage: History & Science
    • /
    • 제48권3호
    • /
    • pp.4-29
    • /
    • 2015
  • To protect cultural heritages from damage and destruction, evaluating the crime prevention environments is considered extremely important. This study analyzed the crime patterns related to cultural heritages, classified the crime environments by their types, and deduced the elements of the CPTED(Crime Prevention Through Environment Design), aiming to present the indices for evaluating the crime prevention environments. The results of this study can be summarized as follows. First, the crimes related to cultural heritages that must be prevented were identified as the night time trespassing and arson. According to the results of the analysis of external environments based on crime actions, the crime prevention environments of cultural heritages were classified into 10 types. Second, the important evaluation principles of the cultural heritage CPTED were the access control, surveillance reinforcement and the surrounding environment. Third, the access control that cover the internal region, boundary, external region and surroundings were classified into 22 indices. The surveillance reinforcement covers natural, organized and mechanical surveillance with 21 indices. Fourth, the applicability of the CPTED evaluation index was presented according to the types of the cultural crime prevention environments. The results confirmed that the maximum 43 indices were applicable to the seowon(lecture hall), hyanggyo(Confucian school), and gwana(district government office), and the minimum 10 indices, to the ramparts. Finally, the 43 indices were applied to Donam Seowon to validate their applicability. The results confirmed that most of the indices were applicable with the partial supplements. The evaluation index presented in this study is likely to contribute to studies in the cultural heritage CPTED field and to the protection of cultural heritages. Furthermore, this study is considered significant because it unleashed continuous concerns on and developments of CPTED. However, as the field survey to validate the applicability of the indices was limited to only one type, it may require further objective verification such as through an expert's examination of the validity and applicability of the evaluation index. In addition, to accommodate the index in related policies and systems, more precise verifications of the indices by type are considered necessary.

A Study on the Florence Renaissance and the Medici's Libraries (피렌체 르네상스와 메디치가 도서관 연구)

  • Yoon, Hee-Yoon
    • Journal of Korean Library and Information Science Society
    • /
    • 제53권3호
    • /
    • pp.73-94
    • /
    • 2022
  • Florence is the cradle of the Italian Renaissance. It is the result of a combination of medieval humanists' exploration of ancient Greek and Roman knowledge and culture, the leadership of great monarchs and priests, patronage of the Medici family, etc., free-thinking and creativity of artists, and critical consciousness and cultural needs of citizens. However, the Florentine Renaissance could not have blossomed unless the Medici family had collected ancient manuscripts and translations, and built libraries to preserve and provide literature. Based on this logical basis, this study outlined the Florentine renaissance and historic libraries, analyzed the collection and composition of favorite books of the Medici family, and traced the architectural characteristics and metaphors of the Medici libraries, The San Marco Library (Michelozzo Library), Library of Badia Fiesolana, and the San Lorenzo Library (Laurentian Library) were the priming and birthplace of the Florentine Renaissance despite of many difficulties, including earthquake, fire, restoration, transfer, seizure, and closure. In particular, the San Marco Library, which was opened in 1444 based on the financial support of Cosimo de' Medici, Michelozzo's design, and Niccoli's private collections was the first common library in the Renaissance period. And the architectural highlight of the Laurentian Library, which opened in 1571 under the leadership of Giulio (Papa Clemente VII), is Michelangelo's staircase, which symbolizes 'from ignorance to wisdom', and the real value of the content is the ancient manuscripts and early printed books, which were collected by the humanist Niccoli and the Medici family. In short, when discussing the Florentine Renaissance, Medici's collection and historic libraries are very important points. The reason is that the ancient collections were not stuffed products, but syntactic semiotics, and the libraries are telescopes that view the history of human knowledge and culture and microscopes that create knowledge and wisdom. If records dominate memories, libraries accumulate records. Therefore, long breathing and time capsule strategies are also required for the development and preservation of retroactive books in domestic libraries with a relatively long history.

Studies on Fire-Retardant-Treatment and Press Drying of Plywood (합판(合板)의 내화처리(耐火處理)와 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • 제10권1호
    • /
    • pp.5-37
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable to bring large fire accidents and burn out human life and their properties. To diminish the fire disaster, fire retardant plywood has been required indeed. In the methods of manufacturing the fire retardant plywood the soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions, redrying of soaked plywood is the most important. In this study, 3.5mm thin and 5.0mm thick plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid and minalith, and water solution. 1-, 3-, 6-, and 9 hour-soaking treatments were applied and after treatments hot plate drying was applied to those treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$, of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1. The plywoods treated with ammonium sulfate, monoammonium phosphate and diammonium phosphate and diammonium phosphate showed increase of chemical absorption rate with proportion to increase of treating time, but not in case of the plywood treated with borax-boric acid and minalith. 2. In the treatment of definite time, the absorption rate per unit of volume of plywood showed higher in thin plywood (thickness of 3.5mm) than in thick plywood (thickness of 5.0mm). In both thin and thick plywoods, the highest absorption rate was observed in 9 hour-treatment of ammonium sulfate. The value was 1.353kg/$(30cm)^3$ in thin plywood and 1.356kg/$(30cm)^3$ in thick plywood. 3. The volume per weight of plywood after chemical treatment increased remarkably and. after hot plate drying, the values were to a little extent higher than before chemical treatment. 4. The swelling rates of thickness in chemical-treated plywoods increased similarly with that of water-treated plywood in 1- and 3 hour-treatment of both thin and thick plywoods. But in 6- and 9 hour-treatment, the greater increased value showed in water-treated ply wood than any other chemical, especially in thick plywood. 5. The shrinkage rates after hot plate drying showed the same tendency as the swelling rate, and the rate showed the increasing tendency with proportion to increase of treating time in thick plywood of both chemical and water treatments. 6. Among drying curves, the curves of water-treated plywood placed more highly than chemical-treated plywood without-relation to thickness in 6- and 9 hour-treatment except in 1- and 3 hour-treatment. 7. The drying rate related to thickness of treated plywood, was twice above in thin plywood compared with thick plywood. 8. The drying rate remarkably increased with proportion to increase of the plate temperature and, the values were respectively 1.226%/min., 6.540%/min., 25.752%/min. in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thin plywood and 0.550%/min., 2.490%/min, 8.187%/min, in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thick plywood. 9. In the treatment at $120^{\circ}C$ of hot plate temperature, the drying rates of chemical-treated plywood showed the highest value in monoammonium phosphate of thin plywood and in diammonium phosphate of thick plywood. But the drying rate of water-treated plywood was highest in 6- and 9 hour-treatment. 10. The fire retardant degree of chemical-treated plywood was higher than that of the untreated plywood as shown in loss of weight, burning time, flame-exhausted time and carbonized area. 11. The fire-retardant effect among fire retardant chemicals were the greatest in diammonium phosphate, the next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric and minalith.

  • PDF