• Title/Summary/Keyword: 건축물 에너지 성능

Search Result 179, Processing Time 0.022 seconds

Process Reference Model for modeling BIM/GIS-based Energy Information (BIM/GIS 기반 에너지 정보 모델링을 위한 프로세스 참조 모델)

  • Kang, Tae-Wook;Ryu, Han-Soo;Ko, Jeong-Lim;Choi, Hyun-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2791-2798
    • /
    • 2015
  • The purpose of this study is to suggest Process Reference Model(PRM) for BIM/GIS-based Energy Information Modeling(BG-EIM) efficiently. Through the study, the detail process and consideration were derived to design EIM for the purpose of energy analysis depending on specific use-cases. To do this, we survey related studies and analyze the detailed EIM process. By using the results, BIM/GIS-based energy analysis consideration is defined and BG-EIM PRM is proposed.

Existing Building Energy Simulation Method Using Calibrated Model by Energy Audit Data (성능진단 데이터로 보정된 모델을 이용한 기존건축물의 에너지시뮬레이션 기법)

  • Kong, Dong-Seok;Kim, Du-Hwan;Chang, Yong-Sung;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.231-239
    • /
    • 2014
  • This paper represents a method of existing building energy simulation using energy audit data. Energy audit must be carried out for reasonable analysis, because characteristics of existing buildings such as efficiency of fan, pump, flow rate, pressure, COP and operating schedule could be changed during the building operation. These building characteristics should be measured to estimate actual energy consumption of the existing building. In this study, we conducted energy audit and calculated energy savings for a 7-stories building as a case-study. The energy audit data were used to calibrate the building model of EnergyPlus simulation. Baseline model validated according to M&V guideline index. As a result, building characteristics are significant parameters making a big impact on energy savings in existing buildings.

Selecting of the Energy Performance Diagnosis Items through the Sensitivity Analysis of Existing Buildings (민감도 분석을 통한 기존건축물의 에너지성능 진단항목 선별)

  • Kong, Dong-Seok;Chang, Yong-Sung;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.354-361
    • /
    • 2015
  • The building energy audit is an important process when collecting basic information for improving the energy performance of existing buildings. Audit parameters should be associated with the energy performance of the building. Such audit parameters will vary according to an individual building's characteristics and energy consumption patterns, but most building energy audits are performed in the same way. The sensitivity analysis (SA) is a statistical method to quantify the correlation between inputs and outputs that can determine which input is influential to which output. Therefore, an SA can identify influential parameters when applied to building energy analysis. In this paper, we adopted the Morris method to identify building energy audit parameters and performed a Monte Carlo simulation for uncertainty analysis. As a result, this method was able to identify an influential parameter for building energy audits and reduce uncertainty in energy consumption in buildings.

A Study on the Evaluation of Thermal Performance of Aluminium Alloy Window Frame considering 2D Steady-state Heat Transfer applied to Educadtional Facility (2차원 정상전열해석을 통한 교육시설의 알루미늄 창호 열성능 평가에 관한 연구)

  • Kang, Jung-Hun;Kwak, Young-Kuhn;Noh, Seung-Uk;Park, Dae-Ho;Lee, Ju-Ho;Hong, Wan-Pyo;Hwang, In-Kyu;Park, Tong-So
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.122-125
    • /
    • 2011
  • 본 연구에서는 기존 교육시설에 설치된 알루미늄 합금 창의 2차원 정상상태 전열해석을 통한 열성능 평가를 수행하였다. 교육시설의 주요 창호재료로 적용된 알루미늄은 열전도율이 $175 \;Kcal/m^2h^{\circ}C$ 정도로 플라스틱 소재와 비교하여 매우 불리하여 기존 시설에 설치된 알루미늄 창호는 열손실의 주요인으로 지적되고 있다. 본 연구에서는 이러한 점에 착안하여 충남 서산지방에 위치한 대학건물의 알루미늄 합금 창호의 열성능 평가에 관한 연구를 수행하여 다음과 같은 해석 결과를 도출하였다. (1) 2차원 정상상태 전열해석을 위한 경계조건은 국토해양부고시 건축물의 에너지절약설계기준의 [별표 6] 중부지방 냉난방장치의 용량계산을 위한 설계 외기온 기준과 [별표 7]의 실내온도 기준을 적용하여 여름철 실내 $27^{\circ}C$, 실외 $31.3^{\circ}C$, 겨울철 실내 $21.0^{\circ}C$, 실외 $-9.6^{\circ}C$ 로 설정하고 해석한 결과 열관류율은 알루미늄 합금 창호는 $U=9.631 \;W/m^2K$, 복층유리 $U= 2.382 \;W/m^2K$로 여름철과 겨울철 동일한 해석결과치가 산출되었다. (2) 산출된 열관류율 해석결과를 건축물의 에너지절약설계기준 [별표 3] 열교차단재가 적용되지 않은 금속제 창의 단열성능 중 일반복층창 성능기준인 $4.0 \;W/m^2K$와 비교할 때, 알루미늄 창틀을 통하여 225%의 열량이 손실됨을 보여 주고 있다.

  • PDF

A Study on the Building Energy Efficiency Rating Changes by Enhanced Thermal Insulation Performance of Building Envelope Standards in Apartment Houses (공동주택에서 외피단열성능기준 강화에 따른 건축물에너지 효율등급 변화에 관한 연구)

  • Cho, Yeong Uk;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • This study aimed to compare the primary heating energy consumption of regional apartment houses based on the enhanced thermal insulation performance of building envelope standards. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the southern region, the largest regional difference in primary heating energy consumption, is $10.3kWh/(m^2{\cdot}year)$. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the central region is $8.0{\sim}8.5kWh/(m^2{\cdot}year)$ and that of the Jeju region is $0.5kWh/(m^2{\cdot}year)$. These energy consumption differences do not result in building energy efficiency ratings changing. The building energy efficiency ratings have the possibility to be changed.

A Study on the Seasonal Performances Evaluation of the Horizontal-type Geothermal Heat Exchanger Installed in the Foundation Slabs of Complex Building (주상복합 건축물의 기초 슬래브에 설치된 수평형 지열교환기의 계절별 성능평가)

  • Hwang, Kwang-Il;Woo, Sang-Woo;Kim, Joong-Hun;Shin, Seung-Ho;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.11-17
    • /
    • 2007
  • This study evaluates the seasonal performances of the horizontal-type geothermal heat exchanger(HGHEX) installed into the foundation slabs of the complex building located at Seoul. The geothermal system is consisted with totally 31,860m long HGHEX, 16 GSHPs (Ground-source Heat Pump) and 8 circulation pumps. This system supplies cooling and heating to the lobby(F1) and the common spaces(BF1). The average heat exchange temperature differences are $2.7^{\circ}C\;and\;2.5^{\circ}C$ in the summer, $1.5^{\circ}C\;and\;0.5^{\circ}C$ in the winter for the F1 and BF1 respectively. From these results, approximately 400Gcal and 180Gcal of geothermal energy are assumed to have been used during the summer and winter seasons respectively. As a conclusion, the geothermal system is reviewed as a effective utility for heating and cooling at the point of seasonal performances.

A Case Study on Energy Performance Analysis of Retrofitted Building Using Inverse Model Toolkit (Inverse Model Toolkit을 이용한 리모델링 건축물의 에너지 성능평가 사례)

  • Kwon, Kyung-Woo;Lee, Suk-Joo;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.394-400
    • /
    • 2014
  • Several models and methods have been developed to verify the improvement of energy performance in retrofit buildings. The verification is important to confirm the effectiveness of new technologies or retrofits. Inverse model toolkit proposed by ASHRAE evaluates the changes of the energy performance of retrofit buildings by using actual energy consumption data. In this study, the inverse model toolkit was used to analyze heating and cooling energy performance of an office building. Analyzed coefficients of correlation of actual energy consumption with estimated energy consumption was above 0.92 and well fitted. It was confirmed that energy consumption of natural gas decreased by 43.4% and also that electricity decreased by 13.8%, after the retrofit of the case building. For the energy usage, cooling energy was increased by 7.4%, heating energy was decreased by 42.3%, hot water and cooking were increased by 3.4%, lighting and electronics were decreased by 19.3%, and the total energy was decreased by 18.9%.

배관 세척장치의 성능평가

  • 조정식
    • 월간 기계설비
    • /
    • s.119
    • /
    • pp.71-83
    • /
    • 2000
  • 점차 복잡해지고 있는 사회적 욕구를 만족시키기 위한 건물에서는 반드시 복잡한 설비가 요구되고 있고, 이러한 설비시스템 중에는 급수, 급탕 및 배수설비라고 하는 배관시스템이 없다면 기능유지에 막대한 지장을 초래할 것은 자명하다고 하겠다. 이러한 배관시스템에서는 항시 또는 일부 사용되어질 물이나 사용된 물이 흐르기 때문에 배관내부에 발생하는 스케일(scale)이나 슬라임(slime) 등은 피할 수 없는 사실인 것이다. 건축물 내에 설치된 각종 배관은 건물의 기능을 유지하고 보건위생과 직결되는 중요한 기능을 담당하고 있어 세척의 필요성이 매우 높음에도 불구하고 배관의 수명이 다할 때까지 거의 세척이 이루어지지 않고 사용되어 왔다. 이들 배관에 대한 세척은 배관의 수명연장과 관마찰 계수를 낮추어 급수의 수송동력을 절감할 수 있고, 난방관의 열전달 효과를 높여 에너지 절약 효과를 거두어 건물의 유지관리 비용 절감에 기여할 수 있음에도 적절한 세척공법이 개발되지 않고 있다. 이러한 관점에 맞추어 건물배관의 특성에 맞도록 고압 세척장치를 개발하고 이를 이용한 세척공법을 적용하고자 하였다. 즉, 배관 내에 압축공기를 주기적으로 분사하여 맥동현상이 일어나도록 하면서 기포를 발생시켜 기포가 관의 내벽에서 성장하여 파괴될 때 관내에 부착된 이물질을 제거할 수 있고, 또한 세척효과를 높이기 위하여 관의 벽면에 접촉하면서 배출되는 과정에서 이물질을 제거할 수 있도록 구조와 아울러 이들 장치를 이용한 세척방법의 적용성에 대해서 고찰하고자 한다.

  • PDF

Seismic Performance Evaluation of Reinforced Concrete Frames Reinforced with Chevron Bracing System (역V형 가새로 보강된 RC 골조의 내진성능평가)

  • Ha, Heonjun;Oh, Keunyeong;Lee, Kangmin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.13-22
    • /
    • 2018
  • In this study, seismic performance of existing RC frames reinforced with steel chevron bracing systems was experimentally evaluated. For this purpose, the unreinforced base specimen and seismically reinforced specimens with steel chevron bracing systems were fabricated and tested. Both strength and stiffness of the reinforced specimens were targeted about 2-3 times larger than the base specimen. Test results showed that the stiffness, strength, and ductility of the reinforced specimens considerably improved than those of unreinforced base specimen. Therefore, the results from this study could offer the basic information on the developing design guideline for the seismic reinforcement of RC frames.

A Reaserch on the Performance Verification of Energy Storage Mortar Enhanced in Thermal Efficiency and Strength by Applying Microencapsulated Phase Change Materials and Nanomaterials (마이크로캡슐로 코팅한 상변화 물질과 나노소재를 적용한 고효율 열저장 시멘트 복합체 성능 검증 연구)

  • Ahn, Jun Hyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.433-441
    • /
    • 2024
  • This study aims to prevent freezing of existing domestic buildings by developing an energy storage mortar with increased energy efficiency that can reduce the increase in carbon emissions and maintenance costs due to external energy use due to heat wires in civil engineering and buildings with embedded heat wires. I suggest. Research has focused on incorporating phase change materials (PCMs) into common cement composites to provide latent heat performance. However, concrete mixed with phase change materials shows problems such as leakage of phase change materials, decreased strength, and insufficient thermal performance. To overcome this problem, we encapsulate phase change materials using microcapsules and mix them into cement composites to minimize strength loss and leakage, and use multi-walled carbon nanotubes and silica fume to minimize the strength reduction of concrete. A heat storage cement composite was developed. When high-efficiency heat storage cement was used as a replacement for ordinary cement composite in an environment where heat wires were buried, the effect was shown to reduce energy by about 42 %, and compared to a cement composite containing only PCM, the compressive strength and bending strength were 18 % and 23 %, respectively. was improved and its effectiveness was proven.