• 제목/요약/키워드: 건축물 에너지 성능

검색결과 179건 처리시간 0.024초

농촌 마을회관 제로에너지 건축물 구축을 위한 에너지 성능 분석 연구 - 충남 태안군 정죽4리 마을회관을 중심으로 - (A study on the analysis of energy performance for zero-energy building of rural village hall - Focused on the Jung Juk 4-le village hall -)

  • 박미란;최정만;이정훈
    • 한국농촌건축학회논문집
    • /
    • 제20권4호
    • /
    • pp.1-8
    • /
    • 2018
  • In this study, we survey the 2 buildings at the Central 1 and 8 buildings at the Central 2, which are divided by each climate region in the rural regions. Major heat loss factors are 47% loss of the outer shell including outer wall, roof, and bottom, 30% loss through window, and 23% loss through crevice wind. We analyze the energy simulation of ECO2 program to construct a zero energy building regarding village hall located in Jung Juk 4-le at Centeral 2. We simulate the primary energy requirement regarding village hall and the simulated results show the $265.3kWh/m^2{\cdot}a$ and it may estimate '2' energy efficiency grade. The energy requirement regarding village hall is the $183.2kWh/m^2{\cdot}a$ when the passive technology are applied in village hall. We research total amount of energy requirement in village hall when the passive and active technologies such as solar cell with 3kW and solar thermal with $20m^2$, geothermal power with 17.5kW. The simulated results show the improved energy efficiency certification grade with $1^{{+}{+}{+}}$ due to the reduced primary energy requirement with 73% when passive technology including 3kW of solar panel is applied and the energy independence rate is 54%, which is estimated to be 4th grade of zero energy buildings. The order of energy consumption are solar panel, solar thermal, and geothermal power under applied passive technology in the building. In order to expand the zero energy building, it is necessary to introduce the zero energy evaluation system in the rural region.

표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가 (Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source)

  • 이용봉;권혁제;김창환;조만희;김항;정성수
    • 한국음향학회지
    • /
    • 제42권2호
    • /
    • pp.143-151
    • /
    • 2023
  • 본 논문은 표준 중량충격원을 이용한 건축물의 바닥충격음 차단성능을 측정하는 경우 측정불확도를 평가하는 방법을 다루었다. 반복 측정의 영향 이외에도 측정 위치의 영향, 가진 위치의 영향, 음압측정에 사용된 장비의 영향 및 충격원의 영향 등을 고려하였다. 평균 최대 바닥충격음 레벨 측정의 수학적 모델을 제시하고 요인별 불확도 평가방법을 제안하였으며, 제안한 방법을 실제 측정 결과에 적용하여 평균 최대 바닥충격음 레벨 및 측정불확도를 평가하였다.

반복하중을 받는 철근콘크리트 보의 에너지소산계수 변화 특성 고찰 (Study on the Variation of Energy Dissipation Factor of Reinforced Concrete Beam under Cyclic Loading)

  • 유석형;강대영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.86-93
    • /
    • 2023
  • 반복하중을 받는 철근콘크리트 부재는 이력거동이 진행됨에 따라 강성과 강도의 저하 그리고 핀칭현상 등으로 인하여 에너지소산 능력이 감소된다. 그러나 지침서 「철근콘크리트 건축구조물의 성능기반 내진설계를 위한 비선형해석모델, 2021」에서는 각 부재별로 모든 이력단계별 단일한 에너지소산계수를 산정하도록 하고 있어 이력단계에 따른 에너지소산능력의 감소를 고려할 수 없을 것으로 판단된다. 따라서 본 연구에서는 반복하중을 받는 일반보에 대한 기존 실험결과와 비선형시간이력해석 결과를 비교하여 이력단계에 따른 에너지소산계수를 고찰하였다. 에너지소산계수는 비선형시간이력해석 결과로 구한 이상화된 탄소성거동 에너지 소산량에 대한 실제 실험체의 에너지소산량의 비로써 산출하였다. 기존 실험결과는 1회 Cycle을 각 이력단계별로 산정하여 에너지소산계수를 도출하였으며, 지침서 내 비선형모델링 과정을 토대로 에너지소산계수를 도출하였다. 기존 실험연구에선 각 이력단계(Y-L-R)를 설정하여 에너지소산계수를 구하였으며, 에너지소산계수는 Y-L구간 0.36, L-R구간 0.28로 나타났고, 지침서 에너지소산계수는 0.31로 나타났다. 이는 지침서의 에너지소산계수 산정식이 철근콘크리트 부재의 에너지소산능력의 감소를 나타내지 못하는 것으로 나타났다.

PCM을 혼입한 시멘트 모르타르의 열적성능에 관한 연구 (A Study on Thermal Performance of Cement Mortar with PCM)

  • 김보현;이한승
    • 콘크리트학회논문집
    • /
    • 제23권4호
    • /
    • pp.521-528
    • /
    • 2011
  • 이 논문은 최근 가속진행 되고 있는 에너지 고갈 및 이산화탄소($CO_2$) 배출 방지대책에 대한 하나의 방안으로서 우수한 잠열 성능을 가진 PCM(phase change materials)을 모르타르에 혼입하고 실험을 통해 PCM의 적정 혼입량 및 모르타르 물성, 성능, 바닥 방식에서의 냉 난방식 적용에 대한 PCM의 효율적인 용융점 등 을 파악하였으며 자체 열적 성능 실험을 통해 열 전달 및 잠열 성능을 확인하였다. 또한 실험에서 도출해 낸 결과에 의해 Fourier의 열법칙을 이용하여 PCM 혼입량별 열전달량과 온도 구배 식을 제안하고 이를 분석하였다. 따라서 이 논문의 결과를 근거로 PCM의 건축물에서의 적용성을 파악하고 냉 난방 에너지 저감 효과를 기대할 수 있는 기초적 자료로서의 근거를 도출하는데 큰 의미를 두었다. 이 실험 결과 PCM 모르타르의 우수한 냉 온 축열 성능을 도출 할 수 있었으며 이를 통해 냉 난방기 On-Off 작동 조절에 의한 에너지 저감 및 그에 따른 $CO_2$ 저감에 대한 가능성을 확인 할 수 있었다.

저 탄소 학교건축물 구현 방안에 관한 연구 (A Study on Realization Method of Low Carbon School Building)

  • 태성호;조영상;신성우;이승민;맹준호
    • 교육녹색환경연구
    • /
    • 제9권2호
    • /
    • pp.30-37
    • /
    • 2010
  • This study purposed realization and a phase reduction of school building $CO_2$ emissions. Accordingly selected standard school buildings and evaluated life cycle environmental load($CO_2$). This study proposed Green building technology which separated design sector, energy sector, afforestation sector for carbon-neutral city school buildings realization of M-city. As a result, elementary, middle and high schools of M-city built in the year 2013 were required that design sector was Energy Performance Index(EPI) 75 point and energy sector was solar installations more than 25% of the power usage, Solar systems installed more than 10% of total gas consumption and the area of afforesting more than 35% of the ecological area to achieve 30% $CO_2$ reduction compared to the Respectively standard school buildings.

학교시설 친환경인증 사례를 통한 에너지 평가항목에 대한 연구 (A Study on the Energy Level of Education Facilities in Green Building Certification Criteria)

  • 권영철;곽문근;최창호
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.688-694
    • /
    • 2009
  • With the increase in the demand for sustainable and environmentally-friendly development, Green Building Certification System came into force in 2002, Evaluation parts of Green Building Certification System are divided into land use and transportation, energy, ecological environment, and indoor environment. Alloted point for the part of energy is larger than other part, thus we can say that this part is very important to increase the green building performance. This study aims to analyze the present condition of design and construction for the part of energy in the certificated green school building. Total 40 certificated school buildings were selected and average scoring rate of each item was evaluated. Key particular to be considered were suggested to improve the item of energy consumption.

스틸하우스 전단벽체의 내진성능평가 (Evaluation of Seismic Performance on Shear Walls in Steel House)

  • 이재석;이승은;홍건호;김원기
    • 한국지진공학회논문집
    • /
    • 제6권6호
    • /
    • pp.65-72
    • /
    • 2002
  • 최근의 건축물 내진 설계 추세에 맞추어, 박판의 냉간성형강으로 제작되는 스틸하우스 전단벽체의 내진 성능을 평가하였다. 시험체는 브레이싱의 종류에 따라 변수를 두었다. 반복가력의 결과로는 에너지소산 능력을 살펴보았는데, 브레이싱 부재로 형강을 사용한 시험체가 판재를 사용한 시험체 보다 우수하였다. 또한, 유사동적실험을 통해서는 면재를 사용한 전단벽체 보다. 스틸하우스 전단벽체 중 하나인 X-브레이싱 형태와 유사한 X2SPCH의 내진성능이 비교적 우수함이 판명되었다.

건축물 계획단계 LCCO2 평가시스템의 필요요소에 관한 연구 (A Study on the Requisite Elements of LCCO2 Evaluation System at Planning Stage of Building)

  • 백정훈;태성호;노승준;이주호;신성우
    • 한국건설관리학회논문집
    • /
    • 제12권3호
    • /
    • pp.31-41
    • /
    • 2011
  • 국내에서 기 개발된 $LCCO_2$ 평가프로그램은 실시설계 이후에 자재물량을 직접 입력하는 방식으로, 최적의 환경부하 저감 전략을 입안하는데 한계가 있었다. 이에 본 논문은 계획단계에서 비용대비 에너지 효율이 높은 방안으로 신속하게 대응하면서 정확성이 높은 시스템을 구축하기 위한 필요 요소를 추출하고 제안하는 것을 목적으로 한다. 이를 위하여 기존의 국내외 $LCCO_2$ 평가프로그램을 비교분석하여 계획단계에서 건축물의 에너지 성능개선 전략수립을 목적으로 한 GEM-21P와 Carbon Navigator를 조사대상 평가프로그램으로 선정한 후, 두 프로그램에 대해서$LCCO_2$ 산출방법과 시스템의 구조에 대한 비교분석을 실시하였으며, 이를 바탕으로 계획단계에서 건축물의 전 생애 환경부하를 평가할 수 있는 시스템구축의 필요요소를 제안하였다.

모니터링 기반 건물 에너지 커미셔닝 기술 (Monitoring-Based Building Energy Commissioning Technology)

  • 이상학
    • 한국통신학회논문지
    • /
    • 제41권7호
    • /
    • pp.765-767
    • /
    • 2016
  • 건물 에너지 커미셔닝은 건축물의 계획, 설계, 시공, 시공 후 설비의 시운전 및 유지 관리를 포함한 전 공정을 효율적으로 검증하고 문서화하여 에너지의 낭비 및 운영상의 문제점을 최소화하는 공정 기술이다. 일반적인 커미셔닝은 설계 기준에 적합한 성능을 발휘할 수 있도록 설비의 교체를 추진한다. 이는 비용이 많이 들며 투자비 회수기간이 오래 걸리는 단점을 지니고 있다. 본 논문에서는 ICT(Information Communication Technology)를 기반으로 에너지 사용 데이터 분석을 통해 설비 교체를 최소화하며 최적 운용을 통해 에너지 효율을 높이는 모니터링 기반 커미셔닝에 대해 연구하였다. 건물 에너지 사용에 대한 모델링을 수행하고 이를 기반으로 에너지 사용 데이터와 비교, 효율 저하 감지 기술을 활용하여 운용 최적화를 통한 에너지 사용 절감을 이룬다.