• Title/Summary/Keyword: 건축물의 재활용

Search Result 63, Processing Time 0.033 seconds

A Study on Validation of the Shielding Effectiveness Measurement Method of the Concrete Containing Electric Arc Furnace Oxidizing Slag (전기로산화슬래그를 활용한 콘크리트의 차폐효과 측정 방법의 유효성 검증 연구)

  • Jang, Hong-Je;Lee, Han-Hee;Choi, Hyo-Sik;Song, Tae-Seung;Cho, Won-Seo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.478-482
    • /
    • 2021
  • In this paper, methods for manufacturing shielding concrete by recycling steelmaking slag discarded as industrial waste and measuring the shielding effectiveness of the shielding concrete were studied. By comparing the result of shielding effectiveness measurement of this concrete block with shielding effectiveness measurement of the structure constructed with this concrete, the measurement system for measuring shielding effectiveness of the concrete block was verified. The size of the concrete stru ctu re is 2.9 × 2.9 × 3.4m and the concrete block is 0.3 × 0.3 × 0.2m. The frequ ency band u sed for mesu rement is 600MHz - 2GHz, the types of concrete u sed to measu re the shielding effectiveness are general concrete and concrete containing electric arc furnace oxidizing slag. In the case of the concrete structure, reinforcing rebars are installed at intervals of 15cm for stru ctu ral safety, as the frequ ency increase, the electromagnetic wave properties of rebars gradu ally decreased, there was a slight difference in the measurement results. In conclusion, the measurement result of shielding effectiveness of the concrete block is similar to the result of the concrete structure. It is thought that it can be sufficiently utilized for electromagnetic wave engineering design, and the concrete shielding effectiveness measurement system using standard specimens was verified.

A Study on the Chloride Diffusivity of Recycled Aggregate Concrete (순환골재 콘크리트의 염화물 확산성에 관한 연구)

  • Bae, Jong-Min;Kim, Young-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.147-153
    • /
    • 2010
  • The recycling of demolished concrete as an alternative source of coarse aggregates for the production of new concrete can help to solve the growing waste disposal crisis and the problem of the depletion of natural aggregates. The purpose of this study is to investigate the chloride migration of recycled aggregate concrete containing pozzolanic materials by the chloride migration coefficient. The specimens were made with recycled coarse aggregate at various replacement ratios (10, 30, 50%) and metakaolin, blast furnace slag, and fly ash is replaced for recycled concrete with a mixing ratio of 20%. The major results are as follows. 1) The compressive strength of recycled aggregate concrete containing pozzolanic materials increases as the curing age and chloride diffusivity decreases. 2) When the replacement ratio of recycled coarse aggregate is 30%, the chloride migration coefficient of recycled concrete containing blast furnace slag or metakaolin that shows a value similar to or lower than that of plain concrete at all ages.

Characteristics of Lightweight and Thermal Insulation of Bituminous Coal Bottom Ash (유연탄 bottom ash의 경량 및 단열 특성)

  • Lee, Jong Gyu;Yeo, Woon Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • Research on FA(Fly ash) is actively carried out, while the research on BA(Bottom ash) is not so, and research on BA recycling field is urgently required. Therefore, in this study, we investigated the lightweight and thermal insulation characteristics of BA mortar by comparing BA mortar made with porous dry BA(air-cooled) and general mortar. To investigate the lightweight of BA, density test, unit volume mass test and SEM(Scanning Electron Microscope) test were performed. BA mortar and general mortar molds were prepared for the thermal insulation test at room temperature and humidity environment determined by KS A 0006 and they were dried at the temperature of $105{\pm}2^{\circ}C$ until the weight became constant. As a result of the lightweight test, the lightweight of BA mortar is about 30% lighter than the general mortar. Therefore, BA is expected to contribute to reduce the building load when used as building material. As a result of thermal insulation test, the thermal conductivity of BA mortar is about 30% better than that of general mortar.

An Experimental Study on the Engineering Characteristics of Ternary Lightweight aggregate Mortar Using Recycling Water (회수수를 사용한 3성분계 경량 골재 모르타르의 공학적 특성에 관한 실험적 연구)

  • Lee, Jae-In;Bae, Sung-Ho;Kim, Ji-Hwan;Choi, Se-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.48-55
    • /
    • 2022
  • This study uses the recovered water as mixing water and artificial lightweight aggregate pre-wetting water as part of a study to increase the recycling rate and reduce greenhouse gas of the ready-mixed concrete recovered during the concrete transport process, and cement fine powder of blast furnace slag(BFS) and fly ash(FA). The engineering characteristics of the three-component lightweight aggregate mortar used as a substitute were reviewed. For this purpose, the flow, dry unit mass, compressive strength, drying shrinkage, neutralization depth, and chloride ion penetration resistance of the three-component lightweight aggregate mortar were measured. When used together with the formulation, when 15 % of BFS and 5 % of FA were used, it was found to be positive in improving the compressive strength and durability of the mortar.

Basic Performance Evaluation of Dry Mortar Recycled Basalt Powder Sludge (현무암석분 슬러지를 재활용한 드라이몰탈의 기초적 성능평가)

  • Ko, Dongwoo;Choi, Heebok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.2
    • /
    • pp.131-138
    • /
    • 2013
  • This study was carried out to investigate the possibility of using basalt powder sludge instead of sand in a normal cement dry mortar as a way to recycle basalt powder sludge, which is a waste product from the manufacturing a process of basalt in Jeju. Basic performance evaluations of the dry mortar material included a compressive strength test, a flexural strength test, and SEM to observe the micro structure. The compressive and flexural strengths were increased to a replacement ratio of 21% of basalt powder sludge, whereby a strength enhancement of about 40% greater than that of normal dry mortar was shown. However, the creation of hydration products affected the replacement ratio of the basalt powder sludge. The possibility of using basalt powder sludge waste was identified in this study, and results showed that the basalt powder sludge waste could be used as a material for a secondary product of concrete.

A Study on the Possibility of Using Concrete Blocks with Ready Mixed Concrete Sludge (레미콘 슬러지를 활용한 콘크리트블록 활용에 대한 기초 연구)

  • Jung, Jae-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.4
    • /
    • pp.307-312
    • /
    • 2019
  • Sludge generated in the production of ready-mixed concrete is classified as waste and processed at a high cost. In particular, small and medium-sized ready-mix manufacturer are burdened with such costs, and some companies are illegally processing them. Therefore, the purpose of this study is to suggest a method for recycled remicon sludge as a concrete block composition. When the remicon sludge is simply dried, the residual chemical admixture and ettringitee contained in the sludge are present, so that the compressive strength of the concrete block and the compressive strength after freezing and thawing are largely deteriorated to meet the quality standards of the concrete shore and retaining wall block It was not possible to do. As a method for satisfying the physical performance, it was found that the remicon sludge was calcined at a high temperature of about $900^{\circ}C$. to decompose ettringite and residual chemical admixture and then used it.

Introduction of BIM Quality Standard for Quantity Take-off (건축 물량산출 활용을 위한 BIM품질기준 도입 방안)

  • Kwon, O-Cheol;Jo, Chan-Won;Cho, Joo-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.171-180
    • /
    • 2011
  • As high-rise and irregularly shaped building structures have become a trend at home and abroad, BIM technology is now being developed and accepted widely. However, the BIM data and information generated in the design phase cannot be actively reutilized in the construction stage. This is because the major interests of construction companies include working process and cost estimation, while there is not usually enough BIM data created to support these activities. In order to resolve this issue, we need to set up BIM modeling guides that make it possible to extract correct quantity take-off from BIM data. Quality checks are also necessary to ensure that the resulting BIM data is correct. This study suggests ways of securing BIM quality for correct quantity take-off, which is critical for BIM technology applied to the building construction process and its cost estimation.

Properties of Mortar with Polysilicon Sludge Based Active Loess Cement (활성황토 시멘트 기반 폴리실리콘 슬러지를 사용한 모르타르의 특성)

  • Kang, Jeon-Uk;Kim, Dae-Yeon;Shin, Jin-Hyeon;Lee, Sang-Soo;Song, Ha-Young
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.275-282
    • /
    • 2018
  • This study examines the ways to address environmental issues by utilizing activated loess to reduce the amount of cements that emit a large amount of carbon dioxide during the process of manufacturing, and by reusing the polysilicon sludge produced as a result of manufacturing polysilicon, one of the components for solar power generation panels. The findings of the experiment showed that the optimal replacement ratio of the polysilicon sludge is 20%, 35% for W/B, and 20% for the ratio of the fine aggregate addition. As it is deemed that utilizing the polysilicon sludge for reinforced concrete may lead to rebar corrosion due to the $CI^-$ contained in the sludge, it can be considered to use for unreinforced concrete or bricks.

A study on methods to reduce environmental load due to stone development- Focusing on Pocheon Art Valley - (건축용 석재개발에 따른 환경 부하 저감 방안에 관한 연구 - 포천 아트밸리를 중심으로 -)

  • Myong-Suk Suhr
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.711-716
    • /
    • 2023
  • A large amount of stone is required as a high-end strategy for building new construction and remodeling work, and aggregates have to be collected from many stone mountains due to the lack of river sand and gravel required for concrete production. This study examines the case of development of stone materials for construction, conduct and analyze residents' attitudes, find out residents' thoughts on stone mountain development, develops the area as an alternative to the devastation caused by stone mountain development, and recycles it as an efficient resource. We intend to conduct basic research to propose a plan. As a result, Local residents have a lot of antipathy against the use of quarry, so it is necessary to use the area that is far from the residents' areas as a quarry. It was concluded that it was desirable to restore and develop in the right direction.

오.폐수 배출시설 방류수의 재이용 가능성 실태조사

  • 민경우;최형일;백계진;정원삼;이대행;김난희;서광엽
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2004.05a
    • /
    • pp.346-349
    • /
    • 2004
  • 광주시 관내 폐수배출시설 방류수 6지점과 대형 건축물 오수 처리시설 방류수 4지점 및 중수 처리 재이용수, 건물 옹벽 지하수 2지점의 수질을 분석하여 중수로써 재이용 가능 여부를 조사한 결과 폐수 배출시설 방류수의 경우 조립금속제품 제조시설, 축전지제조시설 및 타이어제조시설이 대체적으로 중수도의 수질기준을 만족하고 있어 현재의 방류수를 그대로 중수로 이용 가능하리라 판단된다. 오수 처리시설 방류수의 경우 4지점 모두 유기물질은 물론 색도, 탁도 등 대부분의 항목이 중수도 수질기준을 초과하여 현재의 방류수 자체를 중수로 사용하기는 불가능 할 것으로 판단되며, 이들 방류수를 중수로 재이용하고자 한다면 모래 여과조나 활성탄 여과조, 소독시설 등 중수 처리시설을 설치하여야 할 것으로 판단된다. 오수처리시설 방류수를 중수 처리하여 재이용 하고 있는 중수의 경우 대부분 중수도의 수질기준을 만족하였으나, 색도와 탁도, 대장균군의 경우 일부 상당히 불안정한 수질을 보였으나 현재 화장실 세정수로 이용하고 있는데 색도 외에는 별다른 문제가 없는 것으로 나타났고, 대형빌딩 옹벽에서 흘러나오는 지하수의 경우 일반세균과 질산성 질소를 제외하고는 모두 먹는물 수질기준에 적합한 것으로 나타나 현재의 지하수를 그대로 청소용수나 화장실 세정수 등의 중수로 재활용해도 충분하다고 판단되며, 활성탄 여과조와 소독 시설 등의 추가시설을 갖춘다면 먹는 물로도 사용이 가능하리라 보며, 수량적인 측면에서도 1일 발생량이 100~400톤 이상이므로 충분히 경제성이 있을 것으로 판단된다.

  • PDF