• Title/Summary/Keyword: 건축면적

Search Result 517, Processing Time 0.021 seconds

Recent Research Trends for Green Building Thermal Insulation Materials (친환경 건축물 단열재 최근 연구 동향)

  • Park, Jong-Moon;Kim, Dong-Hwan;Suh, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.14-21
    • /
    • 2012
  • The pros and cons of green building thermal insulation materials and systems have been reviewed from traditional thermal insulation materials such as mineral wool and polyurethane to new thermal insulation materials like VIP and aerogel and future insulating VIM and DIM. VIPs and aerogels with very low thermal conductivity can use for green buildings to significantly increase residential area by reducing energy consumption. Aerogels can be produced as not only opaque and but also translucent forms, thus enabling a wide range of possible building application. For building applications, there are many properties to consider like building site adaptability and mechanical strength, fire protection, cost and environmental impact.

Assessment of Optimum Reinforcement of Rebar for Joint of PHC Pile and Foundation Plate (고강도 콘크리트 말뚝과 기초판 접합부의 최적 철근보강량 산정)

  • Park, Jong-Bae;Sim, Young-Jong;Chun, Young-Soo;Park, Seong-Sik;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.1 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • Method of protruding steel bar embedded in PHC pile for connecting with foundation plate is an intermediate form of fixed and hinged connection and has often been used in architectural structures such as apartment complex. However, mechanical properties of this method have not been proved and its construction process is not simple. In this study, therefore, by analyzing previous research and by considering ratio of steel bar and concrete in PHC pile, which is minimum reinforcement of rebar, the newly optimized method of reinforcing joint of PHC pile and foundation plate is suggested with respect to PHC pile type (PHC 450, PHC 500, and PHC 600). To assess mechanical properties (ultimate tensile and shear strength) of joint of PHC pile and foundation plate, full scale experimental tests are performed. As a result, all cases are satisfied with required design criteria and can be practically applied. Our results indicate that reduction of rebar reinforcement compared to previous method would lead cost saving in PHC pile construction.

A Comparison Study on Fire Water Supply Duration and Capacity of Water Based Fire Suppression System of the United States, Japan, China and Korea (우리나라, 중국, 일본, 미국 수계소화설비 소화수 공급시간 및 소화수원에 대한 비교 연구)

  • Min, Se-Hong;Nam, Yu-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.13-20
    • /
    • 2013
  • Buildings in Korea have been getting higher recently and been being changed environmentally since the Korean fire standard was released in 1968. It should be established to make a appropriate correspondence of fire fighting against the those environmental changes. Most of all, fire water capacity which is basis of fire fighting service is a very significant factor. In this paper, the Korean fire water capacity and fire water duration were compared with China, Japan and the United states. Furthermore, fire water capacity, fire water duration, flow rate were compared by hazard classification, occupant use, number of floor and area with water based fire suppression system. This study has been surveyed to show what are difference, similarity, advantage and disadvantage on fire water capacity in the Korean standard comparing with neighboring countries like China, Japan as well as the United states. This study could be found what level the Korean fire water capacity is. So it suggests about more developed standard on fire water capacity with the result of analysis and comparison.

Anti-Corrosion Property of Geopolymer Evaluated by an Impressed Current Cathodic Protection Method, Exposed to Marine Environment (염해환경에서 외부전원법에 의한 지오폴리머 시험체 보강철근의 방식특성 평가)

  • Lee, Hae-Seung;Cho, Ggu-Hwan;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.397-405
    • /
    • 2014
  • There are many literatures reporting that the service life of re-bars in concrete structures is reduced in the oceanic environment due to chloride attack. To solve this problem, this study used geo-polymer as a mix material for concrete to increase its resistance to salt damage, and the external voltage method, one of the electric methods, is was applied to evaluate the likelihood of re-bars in the oceanic structure being exposed to the extreme salt environment. The items evaluated include the natural potential of re-bars and the corrosion rate. The results of the tests showed that in all of the salt environmental conditions (submerged zone, tidal zone, and crack), the tested materials were remarkably effective compared with ordinary concrete. The corrosion protective property was found not only in the evaluation of the natural potential but also in the evaluation of the corrosion rate, suggesting that the external voltage method can be used stably for geo-polymer RC structures in an extreme salt environment.

Pore and Efflorescence Characteristics of Alkali Activated Slag-Red Mud Cement Mortar depending on Red Mud Content (레드머드 대체율에 따른 알칼리활성화 슬래그-레드머드 시멘트 모르타르의 기공 및 백화특성)

  • Kang, Suk-Pyo;Kang, Hye-Ju
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.3
    • /
    • pp.261-268
    • /
    • 2017
  • Red mud is an inorganic by-product obtained from the mineral processing of alumina from Bauxite ores. A highly alkali inorganic waste product with a pH level over 11, red mud in its original state negatively impacts the ecosystem, so appropriate treatment is necessary. The development of alkali activated slag-red mud cement can be a representative study aimed at recycling the strong alkali of the red mud as a construction material. However, Alkali-activated binders that use sodium activators have been reported to be more vulnerable to efflorescence. Therefore, in this study, the compressive strength, pore characteristics, water absorption, elution characteristics, and efflorescence properties of alkali-activated slag cement mortar were assessed according to their red mud substitution ratio.

An Experimental Study on the Fire Resistance Capacity of Asymmetric Slimflor Beam (비대칭 H형강 슬림플로어 보의 내화 성능에 관한 실험적 연구)

  • Park, Won-Sup;Kim, Heung-Youl;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.40-45
    • /
    • 2010
  • Asymmetric Slimflor Beam had been unveiled with Thor beam (Hat beam) in Sweden since the late 1970s and had been developed by British Steen and SCI. In the major advanced countries in Europe after the early 1990s have interested in and developed this method, it has been concrened as the absence of hot-rolled section steel in the United Kingdom and welded of asymmetric section steel in Finland in the 2000s. It can be increase total floor area about 10%, save the interior and exterior materials, reduce the waste through reduction of the floor height. And it has more excellent fire resistance performance because less exposed than a regular composite steel beam in fire. This study is purpose that, a fire resistance performance of the Asymmetric Slimflor Beam in fire, it compared the temperature range with deflection of structure by fire behavior and load ratio of structure through change the shape of the steel cross-section in standard fire condition.

Extraction of Heavy Snowfall Vulnerable Area for 3 Representative Facilities Using GIS and Remote Sensing Techniques (GIS/RS를 이용한 3개의 대표 시설물별 폭설 취약지역 추출기법 연구)

  • Ahn, So-Ra;Shin, Hyung-Jin;Kim, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.1
    • /
    • pp.1-12
    • /
    • 2015
  • This study is to analyze the heavy snowfall vulnerable area of snow load design criteria for greenhouse, cattle shed and building using ground measured snow depth data and Terra MODIS snow cover area(SCA). To analyze the heavy snowfall vulnerable area, Terra MODIS satellite images for 12 years(2001-2012) were used to obtain the characteristics of snow depth and snow cover areas respectively. By comparing the snow load design criteria for greenhouse(cm), cattle shed($kg/m^2$), and building structure($kN/m^2$) with the snow depth distribution results by Terra MODIS satellite images, the facilities located in Jeolla-do, Chungcheong-do, and Gangwon-do areas were more vulnerable to exceed the current design criteria.

Locational Characteristics and Use Factors of Public Wi-Fi in the Jeju Province (제주도 공공와이파이의 입지 특성과 이용 요인에 관한 연구)

  • Kim, Heungsoon;Choi, Seungho;Lee, Hamin;Lim, Hawon;Oh, Yunchan;Kim, Seong-A
    • Land and Housing Review
    • /
    • v.12 no.4
    • /
    • pp.1-13
    • /
    • 2021
  • This study investigates the effectiveness of Jeju's public Wi-Fi policy for which the key factors of public Wi-Fi use and location characteristics are analyzed. Spatial regression analysis was conducted within a 100 m radius of public Wi-Fi access points. In the analysis, the dependent variable was public Wi-Fi usage time while independent variables included demographic factors, location factors, and other factors. The findings reveal that demographic factors such as the number of residents, the number of workers, and the number of visitors had a close correlation with the use of public Wi-Fi. In addition, the number of bus stops and land prices of each parcel, land use mix, and AP installation period had a positive correlation with the use of public Wi-Fi. On the contrary, the number of buildings by use, the total floor area of buildings, and the number of tourist attractions had negative correlations with public Wi-Fi usage time. These findings provide policy implications that more active publicity on Jeju's public Wi-Fi is needed and the convenience for access needs to be improved.

Forecast of Repair and Maintenance Costs for Public Rental Housing (공공임대주택의 유지관리를 위한 수선유지비용 예측)

  • Lee, Hak-Ju;Kim, Sunghee;Kim, Do-Hyung;Cho, Hunhee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.621-631
    • /
    • 2018
  • The repair and maintenance cost of domestic public rental housing is an issue of considerable interest and growing financial concern. This paper suggests a quantity-based model as an alternative method for predicting costs, instead of the conventional model which is based on actual cost data. Furthermore, this paper provides a forecast of the repair costs incurred each year during the multi family house's maintenance phase (40 years). The recently changed the long-term repair plan and quality-improved interior materials were considered into the research. In order to estimate the cost of maintenance work, 5 sample apartments were selected and analyzed. The repair and maintenance cost from the case studies was converted to cost per household and per floor area for general use. On the other hand, the net present value method was applied to reflect the effect of time. We expect that the results will help to establish expenditure plans that are more effective for public rental housing in the maintenance stage.

A Study on Rainwater Utilization Methods of Rainwater Harvesting System (빗물이용시설의 빗물이용 활성화 방안 연구)

  • Park, Yoonkyung;Song, Yang Ho;Choi, Youngkwon;Kim, Reeho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.501-501
    • /
    • 2022
  • 2014년 개정된 물의 재이용 촉진 및 지원에 관한법률(이하, 물재이용법)에 따라서 빗물이용시설의 수는 꾸준히 증가하고 있는 추세이나 실제 연간사용량의 경우 연별 증가량은 미미하다. 또한 2016년도 환경부 하수도 통계에 따른 2,043개의 빗물이용시설 중 집수면적 미파악시설의 749개, 여과시설 유무 미파악시설 564개, 연간 운영비 산출 불가능 시설 1,843개, 연강 사용량 미집계 시설 905개로 관리실태가 부실함을 확인할 수 있다. 이에 빗물이용시설의 설치·운영 실태조사 및 문제점을 분석하고 빗물이용이 비교적 활성화 된 시설을 대상은 현장조사를 수행을 통해 빗물이용시설의 현황을 분석하고 현실적인 여건을 반영하여 빗물이용을 활성화할 수 있는 방안을 마련하고자 하였다. 물재이용법에 따른 빗물이용시설 법정의무대상시설의 빗물활용처는 전체의 약 92%가 조경요수로 활용하고 있으며, 다음으로 청소화장실용수(약 3%)로 활용하고 있다. 건축물 용도에 따라서 골프장, 공공기관청사/공공업무시설, 대규모점포, 실내체육관/종합운동장, 학교의 경우 건축물 용도별로 각 30% 정도가, 공동주택의 경우 약 60%가 빗물이용시설을 활용하고 있음에도 빗물을 사용하지 았는 것으로 파악되었다. 이는 빗물을 사용해야하는 시기에 저류조에 저류된 빗물의 양이 부족한 것과 운영비 부담 순으로 조사되었다. 따라서 빗물이용시설의 빗물이용활성화를 위해서는 물수요-공급에 대한 개념을 도입한 물수지 분석이 필요하며, 운영비 부담을 줄일 수 있는 다양한 방안을 탐색하는 것이 적절할 것이다. 현장조사 결과에서도 기술 등의 발달로 빗물이용시설은 잘 구축되고 있으나 활용처에서 필요한 필요수량에 따라 활용률이 상이한 것으로 조사되었다. 이러한 실태조사 및 현장조사를 바탕으로 빗물이용시설의 빗물이용 활성화를 위한 방안에 대하여 기술적 및 제도적 방안에 대해서 제안하였다.

  • PDF