• 제목/요약/키워드: 건물 재생

검색결과 268건 처리시간 0.029초

RETScreen을 활용한 건물에서의 지열 히트펌프 시스템 적용 사전 분석연구 (Pre-Analysis Study on Ground Source Heat Pump System in Building with RETScreen)

  • 김유진;이광섭;이의준;강은철
    • 한국태양에너지학회 논문집
    • /
    • 제40권2호
    • /
    • pp.1-10
    • /
    • 2020
  • Korea government published renewable energy obligation policy that public building must be supplied some part of total consumption energy (2019: 27%, 2020: 30%). RETScreen is freely available global energy tool that developed by Canadian National Energy Laboratory to quantify energy saving to compare conventional system. This program can be performed energy modeling, cost analysis, greenhouse gas emission analysis and financial analysis. In this study, GSHP (Ground source heat pump) heating and cooling system were studied for the energy deliverly and ROI (Return On Investment) in an office building. Three cases were studied according to the number of HP (Heat pump) units for the 1,000㎡ office building located in Daejeon. Results indicated that the energy delivery of the case 1 (1 HP unit) covered 57% of the office building heating and cooling energy consumption. The case 2 (2 HP units) covered 87.8% and the case 3 (3 HP units) covered 96.8% of the office building energy consumption. The ROI of the case 1 indicated 7.9 years. While 8.2 years for the case 2 and 9.7 years for the case 3.

태양전지를 활용한 노후 건축물 그린 리모델링 디자인 사례분석 연구 (Old building green remodeling design cases study analysis using solar cell)

  • 박지훈;남원석;장중식
    • 한국융합학회논문지
    • /
    • 제11권9호
    • /
    • pp.155-162
    • /
    • 2020
  • 본 연구는 파리기후변화협약 이후 전 세계적으로 각광받고 있는 태양전지를 활용한 노후 건축물 그린 리모델링 디자인의 국내외 사례 분석을 바탕으로 향후 진행할 태양전지를 활용한 그린 리모델링 디자인 제안의 긍정적인 측면과 시사점을 확인하고자 하였다. 연구의 방법으로는 문헌연구를 바탕으로 이론적 고찰을 진행하였고, 이후 국내외 태양전지를 활용한 그린 리모델링 디자인의 사례를 조사·분석하였다. 그 결과 플렉서블한 특징을 통한 시공의 용이성, 박막전지의 투명도와 색상의 조절을 통한 심미적 효과, 자유로운 사이즈 제작으로 재료 낭비가 적은 경제적 효과, 외관의 직접 부착을 통한 건물과의 조화로운 측면을 확인할 수 있었다. 이러한 점을 토대로 박막 태양전지를 그린 리모델링 디자인에 활용하여 올 수 있는 기대효과와 유효성을 제시하고, 향후 진행할 태양전지를 활용한 노후 건축물 그린 리모델링 디자인 제안에 대한 방향성과 참고 자료로 활용되기를 기대한다.

적층형 박막 실리콘 태양전지 효율의 한계 및 돌파구

  • 명승엽
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.27-27
    • /
    • 2010
  • 최근에 고유가와 지구온난화로 인하여 에너지가 향후 인류의 50년을 좌우할 가장 큰 문제로 대두되고 있어서 지구의 모든 에너지의 근원인 태양광을 이용하는 태양광 발전은 무한한 청정 에너지로 각광받고 있다. 빛을 흡수하여 전기에너지로 변환하는 태양전지는 풍력, 수소연료전지, 조력, 바이오에탄올 등의 신재생에너지 기술 중에서 상품성은 가장 뛰어나지만 발전단가가 가장 높은 것이 단점이다. 태양광 발전단가를 줄여서 기존의 화석에너지를 이용한 발전단가와 견줄 수 있는 그리드 패러티(grid parity)를 달성하려면 태양전지 모듈의 고효율화와 동시에 저가화가 반드시 이루어져야 한다. 현재 태양광 모듈 시장의 90%는 효율이 12-16% 정도로 높은 단결정(single crystalline or monocrystalline) 실리콘이나 다결정(polycrystalline or multicrystalline) 실리콘 등의 벌크(bulk)형 결정질 실리콘 모듈이 차지하고 있으나 원재료인 실리콘 웨이퍼의 제조단가의 50%를 차지하고 있어서 저가화가 어렵다. 반면, 원료가스를 분해하여 대면적 기판에 증착하는 박막(thin-film) 실리콘 태양전지의 경우는 차세대 태양전지로 각광받고 있다. 박막 실리콘 모듈은 매우 적은 실리콘 원재료를 소비한다. 단결정이나 다결정 실리콘 웨이퍼의 두께가 $180-250\;{\mu}m$ 정도인 것에 비해서 박막 실리콘의 두께는 $0.3-3\;{\mu}m$ 수준이다. 더불어, 유리, 플라스틱 등의 저가 기판에 저온 대면적 증착이 가능하여 저가양산화에 유리하다. 박막 실리콘 모듈은 벌크형 실리콘 모듈(-0.5%/K) 대비 낮은 온도계수[비정질 실리콘(amorphous silicon; a-Si:H)의 경우 -0.2%/K]와 빛의 세기가 약한 산란광에서도 동작하여 평균발전시간이 증가하므로 외부환경에서 우수한 발전성능을 보이고 있다. 태양전지 모듈은 상온에서의 안정화 효율을 기준으로 가격이 책정되어($/$W_p$) 판매되기 때문에 벌크형 실리콘 모듈에 비해서 박막 실리콘 모듈은 가격대 성능비가 우수하다. 따라서 박막 실리콘 모듈은 벌크형 결정 실리콘 모듈의 대안으로 떠오르고 있으며, 레이저 기술을 이용하여 수려한 투광형 건물일체형(building integrated photovoltaic; BIPV) 모듈을 제작할 수 있는 장점도 있다. 이러한 장점에도 불구하고 기존의 양산화된 단일접합 비정질 실리콘 태양광 모듈은 효율이 6-7%로 낮아서 설치면적 및 설치 모듈의 증가가 성장의 걸림돌이 되고 있다. 박막 실리콘 태양전지의 고효율화를 도모하기 위해서 적층형 탄뎀셀로 양산 트렌드가 변화하고 있다. 이에 적층형 박막 실리콘 태양전지 효율의 한계 및 돌파구에 대해서 논의한다.

  • PDF

외기보상제어 적용에 따른 지열 히트펌프 시스템의 에너지 효율 향상에 관한 연구 (A Study on the Energy Efficiency of a Geothermal Heat Pump System in use the Outdoor Reset Control Application)

  • 정영주;김효준;이용호;황정하;조영흠
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.45-52
    • /
    • 2015
  • The government is fostering a renewable energy industry as an alternative to handle the energy crisis. Among the renewable energy systems available, geothermal energy is being highlighted as being highly efficient and safely operable without the effect of outdoor air. Accordingly, a study on the geothermal heat pump is in progress in various worldwide perspective. However, Geothermal energy is only in charge of part load of the building due to the high initial installation cost in korea. Moreover, its efficiency is reduced due to the use of independent existing heat sources. In this study, after selecting the building containing the actual installed geothermal heat pump, the use of excellent geothermal heat pump systems was maximized in terms of the energy efficiency. The objective of this study is to show the operation method of geothermal heat pump system to improve energy efficiency through the TRNSYS simulation. This paper proposed operation methods of geothermal heat pump control according to outdoor air temperature. The result of this study is that existing operation method had some problems and if offered improvement is applied to real condition, energy consumption would be decreased.

BIPV 시스템의 차양 효과에 따른 피크 냉방부하 절감효과에 관한 연구 (A Study on the Reduction effect of Peak Cooling Load on the Sunshade effect of BIPV System)

  • 이충식;이응직;이철구
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.14-20
    • /
    • 2008
  • As the number of buildings that use the transparent permeation materials as the outer wall is on the increase, the coming amount of the light rays is a lot, and thus the increase in the cooling load and the radiant heat of high temperature may cause the residents to discomfort. In order to reduce such influences, this paper analyzed the installation effects of the sunshade BIPV. The inner temperature of the room installed the sunshade BIPV or otherwise was measured, and compared and analyzed the effects of reducing the cooling load by the incoming light rays. The sample space of the third floor of S university installed the sunshade BIPV has two rooms on the same conditions, and for five sunny days selected in August, the researcher measured the air temperature and the temperature of the fittings with closing the windows to minimize the movement of air without operating the coolers. The maximum cooling load measured by the incoming light rays in the room where the sunshade BIPV was not installed was examined as 459.13kcal/h. It can be understood as the effect of reducing the cooling load according to the incoming rays of the room with sunshade BIPV. Even though the effect of cooling load reduction is not so great in a room, the total reduction in cooling room for the 32 rooms installed the sunshade BIPV was estimated to be 40442.27kcal/day, which will be able to bring the maximum reduction effect of 17.1kW in energy and reduce the investment cost owing to the reduction in cooling load when initially designing the building.

R을 활용한 주거환경 중요도 요소에 대한 분석 (Analysis on the Importance Factor of Residential Environment using R)

  • 오형준;최영오
    • 창의정보문화연구
    • /
    • 제6권3호
    • /
    • pp.209-217
    • /
    • 2020
  • 최근 데이터 분석에 대한 관심이 높아지며 공학, 자연과학, 사회과학 영역 등 다양한 분야에서 데이터 분석을 통한 융·복합 연구가 활발하게 이루어지고 있다. 건축분야 역시 데이터 분석을 활용한 다양한 연구가 진행되고 있으며 특히, 이를 통해 도시화 과정을 통해 양적 확대를 진행해왔던 건축분야의 문제점을 해결하고자 하는 노력이 이루어지고 있다. 본 연구에서는 도시재생사업을 통한 주거환경 개선지역과 유사 인근지역 주거자의 주거만족도에 대한 데이터 분석을 수행한다. 건물 건축과 입주 후 진행되는 거주 후 평가 요소에 대해 R을 활용한 분석을 통해 각 평가 요소 간의 연관규칙 분석과 거주자의 주요 요구 사항의 빈도 수 파악을 통해 주거환경 만족도에 영향을 미치는 중요 평가 항목을 파악한다. 이를 통해, 향후 건축 분야에서 주거지 구성 시 양질의 주거 공간 확보를 위한 데이터 제공과 함께 양질의 주거지역을 추천할 수 있는 시스템의 개발 등 IT와 건축분야 간의 융·복합 연구를 진행하고자 한다.

공동주택의 분별해체를 위한 부위별 원단위 산정사례연구 (A Case Study of Estimating Units of Deconstruction Waste by Each Parts for the Apartment)

  • 김창학;이경희
    • 대한토목학회논문집
    • /
    • 제28권1D호
    • /
    • pp.73-81
    • /
    • 2008
  • 향후 국내의 주택건설 산업은 신규 택지개발에 의한 주택공급 방식보다는 기존 주택의 재개발 및 재건축에 더 큰 비중을 둘 수밖에 없으며, 현재 그러한 추세가 급속하게 확산되고 있다. 또한 재고주택 중 공동주택이 50% 이상을 차지하고 있으며, 이들의 유지보수, 리모델링 및 재건축은 주거지의 슬럼화 방지, 건물성능 저하에 따른 재난방지 등을 위하여 반드시 필요한 분야가 되었다. 따라서 이러한 재개발 재건축 등의 활성화로 인하여 도심지 해체공사가 증가함에 따라 건설폐기물의 발생량이 대폭 증가하고 있다. 따라서 건설폐기물의 적정관리는 매우 중요한 사항이 되어 가고 있으나, 발생 폐기물을 정확히 예측하기 위한 연구가 부족하였다. 따라서 본 연구에서는 공동주택의 해체물량을 정확히 예측할 수 있는 건설폐기물 원단위 산정 기준을 제시한다. 이것은 해체공사시 발생 가능한 건설폐기물을 손쉽고 정확히 예측할 수 있으며, 이것은 국가 폐기물 정책에 매우 중요한 자료로 활용될 수 있을 것이다.

제주지역 말 방목체계에서 동계사료작물의 말 기호성 및 생산성 (Palatability and Yield of Winter Annual Forage Crops under Horse Grazing System in Jeju)

  • 박남건;우제훈;유지현;신상민;박형수;황원욱
    • 한국초지조사료학회지
    • /
    • 제40권2호
    • /
    • pp.106-110
    • /
    • 2020
  • 본 연구는 일년생 사료작물인 이탈리안 라이그라스, 귀리, 호밀을 파종하여 말방목 체계하에서 생육특성, 생산성 및 방목지에서의 말의 기호성 등을 조사하기 위해 수행하였다. 일년생 사료 작물은 10월 30일에 파종하였으며 말 방목은 이듬해 3월 17일에 시작하였다. 1차 예취시 건물수량은 호밀이 4,600kg/ha로 이탈리안 라이그라스와 귀리에 비해 높은 수량을 나타내었다(p<0.05). 2차와 3차 예취시 건물수량은 사료작물간에 유의적인 차이를 보이 않았으나 시간이 경과할수록 이탈리안 라이그라스의 수량이 높아져 총 건물수량은 이탈리안 라이그라스가 10,941kg/ha으로 호밀 12,593kg/ha와 귀리 9,424kg/ha와 비슷하였다. 사료작물별 채식시간은 이탈리안 라이그라스가 귀리와 호밀에 비해서 월등히 높았다(p<0.05). 1차 방목과 2차 방목에서 이탈리안 라이그라스의 채식시간은 각각 853.2초, 989.4초였으며, 귀리는 147.6초 73.0초 그리고 호밀은 89.4초, 33.18초였다. 각 사료작물별 채식률은 이탈리안 라이그라스가 귀리와 호밀에 비해 1차와 2차 방목 모두 가장 높게 나타났다(p<0.05). 이탈리안 라이그라스의 채식률은 1차에서 60.0%, 2차에서 82.8%였으며, 평균 채식률은 71.4%를 보였다. 일년생 사료작물의 1번초의 수량은 호밀이 가장 높았지만, 작물의 재생능력과 총 생산성, 말의 기호성은 이탈리안 라이그라스가 월등히 우수했다. 이상의 결과를 종합해 보면 제주지역에서 말을 방목하기 위한 동계사료작물의 재배 이용은 이탈리안 라이그라스가 가장 적합하다고 판단된다.

커피전문점 권리금의 결정변수에 관한 연구 (A Study on the Determinants of Coffee Shop's Premium)

  • 임재현;정승영
    • 지적과 국토정보
    • /
    • 제44권1호
    • /
    • pp.213-226
    • /
    • 2014
  • 이 연구는 서울시의 주요 상권에 위치한 커피전문점의 상가임대사례를 활용하여 상가권리금에 영향을 주는 변수를 파악하는 것이 목적이다. 구체적으로는 커피전문점의 상가매출액, 상권, 입지 특징이 상가권리금에 미치는 효과를 분석하였다. 이 연구의 결과를 요약하면 다음과 같다. 첫째, 커피전문점의 상가권리금과 매출액 사이에는 높은 정(+)의 상관관계가 있으며 $3.3m^2$당 상가매출액 및 상가월세는 $3.3m^2$당 상가권리금을 추정할 때 통계적으로 유의한 영향력 있는 독립변수로 나타났다. 이는 커피전문점의 상가권리금을 결정하거나 도심재생사업에서 상가권리금의 보상액을 산정할 때 상가매출액은 실증적으로 중요한 변수라는 것을 의미한다. 둘째, $3.3m^2$당 상가월세, $3.3m^2$당 상가보증금의 비중, 공공기관 종사자도 역시 상가권리금을 결정하는 중요한 변수이다. 셋째, 상가면적과 상가권리금과는 부(-)의 상관관계가 형성되어 상가면적이 증가할수록 상가권리금이 하락하였다. 요약하면, 커피전문점이 입지한 상권 및 입지, 건물특징이 상가권리금에 영향을 준다는 연구가설을 채택한다.

정단 및 마디조직 배양을 통한 지황의 기내 증식 (In Vitro Propagation by Shoot-tip and Node-bud Culture of Rehmannia glutinosa)

  • 백기엽;유광진;박상일
    • 식물조직배양학회지
    • /
    • 제25권1호
    • /
    • pp.63-68
    • /
    • 1998
  • 정단 및 마디조직을 이용한 지황의 기내증식방안을 마련하기 위하여 일련의 시험을 실시하였다. 재생된 신초의 정단을 재배양하였을 경우 BA 5.0 mg/L에서 7.8개의 신초가 형성되었으며 투명화된 묘의 발생은 Gelrite 보다는 Bacto-agar 첨가구에서 감소하였다. 광도와 한천의 농도가 증가할수록 신초형성수 및 생장은 억제되었고 생체중 : 건물중의 비율도 감소하였다. 광도가 2000 lx일 때는 Bacto-agar 0.6-1.2%, 3,000 lx에서는 한천 0.4-0.6%에서 건전한 신초를 10개 이상 생산할 수 있었다. 활성탄소 0.1-0.3%첨가는 신초의 생장촉진과 뿌리형성에 촉진적으로 작용하였으며 투명화 발생률도 감소시켰으나 신초형성수는 현저히 감소시켰다. MS배지내 첨가되는 다량원소의 농도를 0.8-1.0배 하였을때 신초형성수 및 생장이 촉진되었다. 기관형성에 미치는 오옥신의 종류 및 농도별 효과를 조사한 결과 NAA나 IBA 보다는 IAA 0.3mg/L 와 BA 5.0mg/L를 혼합처리 하였을 때 증식률이 16배에 달하였다.