• Title/Summary/Keyword: 거처

Search Result 112, Processing Time 0.023 seconds

Development of a Continuous Electrolytic System for pH-control with Only One Discharge of Electrolytic Solution by Using Non-equilibrium Steady State Transfer of Ions across Ion Exchange Membranes (이온 교환막에서 이온의 비 평형 정상상태 이동을 이용한 단일 전해액의 배출만을 가지는 pH 조절용 연속식 전해 반응기 개발)

  • Kim Kwang-Wook;Lyu Je-Wook;Kim In-Tae;Park Geun-Il;Lee Eil-Hee
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.101-109
    • /
    • 2005
  • In order to produce only a pH-controlled solution without discharging any unused solution, this work has developed a continuous electrolytic system with a pH-adjustment reservoir being placed before an ion exchange membrane-equipped electrolyzer, where as a target solution was fed into the pH-adjustment reservoir, some portion of the solution in the pH-adjustment reservoir was circulated through the cathodic or anodic chamber of the electrolyzer depending on the type of the ion exchange membrane used, and some other portion of the solution in the pH-adjustment reservoir was discharged from the electrolytic system through other counter chamber with its pH being controlled as acid or base. The phenomena of the pH being controlled in the system could be explained by the electro-migration of the ion species in the solution through the ion exchange membrane under a cell potential difference between anode and cathode and its consequently-occurring non-charge equilibriums and electrolytic water- split reactions in the anodic and cathodic chambers.

  • PDF

Development of Measurement Scale for School Police's Job Performance (학교보안관의 직무수행 척도 개발)

  • Kim, Kyong-Sik;Kim, Eun-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.394-405
    • /
    • 2012
  • This study is aimed at developing a tool to measuring school police's job performance, and verifying its credibility and validity. This study collected the sample to 250 subjects using a significance collection method to parents of elementary schools school police work. But excluding dishonestly responding data, this used total 210 people for the final analysis. This study executed experts' meeting, exploratory and confirmatory factor analysis, and item analysis to verify reliability, and verification of internal consistency and reliability. This study extracted and confirmed 7 factors for specialization, attitude, program, prevention activity of school violence, effect, basic duty, teaching for school time and home time, and correlation with related people. Through the above research approach and procedure, this study arrived at the following conclusion. First, validity to school police's job performance and measurement tool to job performance is very high. That is, school police's job performance was explored and confirmed through correlation with specialization, attitude, program, prevention activity of school violence, effect, basic job, teaching for school time and home time, and related people, and of them, explanation of attitude is the highest. Second, reliability to the measurement scale for school police's job performance is very high. That is, school police's job performance has high correlation between items, sub-factors, and total scores, and reliability of internal consistency, Cronbach's ${\alpha}$ value, is over .708. Putting them together, measurement scale for school police's job performance is a questionnaire sheet with very high level of validity and reliability.

A Study on the Characteristics and Landscape Meaning Analysis of 'Gumi and Sipalgyung' in Jeongseon Gumijeongsa (정선 구미정사의 성격과 '구미(九美) 18경'의 경관의미)

  • Kim, Soonki;Rho, Jae-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.2
    • /
    • pp.63-74
    • /
    • 2016
  • The purpose of this study is to expand a prospect of a few-remaining Byeolseo scenic sites of Gangwon-do(Province) through determining placeness formation, prospect characteristics, and landscape meanings of Gumi(Nine beauties) and Sipalgyung(18 scenic views) in Gumijeongsa. Gumijeongsa, which is located in a riverside of the Goljicheon(stream), a part of upstream of Namhangang, is the oldest existing Nujung architecture in the Jeongseon area. This study tried to unearth the Gumijonegsa's locational and formational characteristics through literature review and a field survey. Especially, through the field survey, this study tried to figure out the landscape meanings and contents of Gumi and Sipalgyung by Gumijeongsa's position and its prospect compositions. As a result of this study, Gumi and Sipalgyung of Gumijeongsa are variations of typical traditional culture of Gugok(Nine river bends) and Palgyung(Eight scenic views). Ja Lee, the founder, administrated Gumijeongsa as a core residence of Gugok culture. He established beautiful nine viewpoints from the building, named Gumi, and added 18 detailed landscapes(two landscapes for one beauties), instead of establishing nine river bends of the stream. The Gumi and Sipalgyung are formed by reflection of beautiful locational characteristics from the views in Gumijeongsa, thus the Gumi is the concept which is a unique variation of Gugok and Palgyung culture.

Selectivity and Reasons for Move of Inter_Provincial Migrants in Korea: With Special Reference to the Capital Region (한국 지역 간 인구이동의 선별성과 이동 이유: 수도권을 중심으로)

  • Choi, Jin-Ho
    • Korea journal of population studies
    • /
    • v.31 no.3
    • /
    • pp.159-178
    • /
    • 2008
  • The main purpose of this paper is to examine selectivity and rasons for move of internal migrants in Korea. There have only been a few studies available on the issues of selectivity and reasons for move of internal migration in Korea, mainly due to the lack of appropriate data. The main source of data for this analysis come from the raw data set of the 1997 Special Migration Survey conducted by the National Statistical Office. Analysis of selectivity of those who moved across the provincial boundary revealed that females, young adults, singles in their marital status and more educated are more likely to move. Among various reasons for move, employment related reason is the most important for all migration streams. But with different migration streams, diverse patterns are emerged. For those who moved into the Capital Region, employment related reason is outstanding. But those who moved out from the Capital Region, moved for employment as well as family related reasons. For movement within the Capital Region, housing related reason is equally important together with employment and family reason. The analysis also found that among individual attributes, age and marital status affect most significantly to the reasons for move. Education level and housing ownership are also important for explaining for variations in reasons for move.

$Al/TiO_2-SiO_2/Mo$ 구조를 가진 Antifuse 의 전기적 특성 분석

  • 홍성훈;배근학;노용한;정동근
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.73-73
    • /
    • 2000
  • 안티퓨즈 소자는 프로그램 가능한 절연층의 상하 각각에 금속층이나 다결정 실리콘 등의 전도 가능한 전극으로 구성된다. 프로그램은 상하 전극간에 임계전압을 가했을 때 일어나게 되며 이때 절연층이 파괴되므로 비가역적이어서 재사용은 불가능하게 된다. 안티퓨즈 소자는 이러한 프로그램 특성으로 인하여 메모리 소자를 이용한 스위치 보다 속도나 집적도 면에서 우수하다. FPGAsdp 사용되는 안티퓨즈 소자는 집적도의 향상과 적정 절열파괴전압 구현을 위해 절연막의 두께를 감소시키는 것이 바람직하다. 그러나 두께나 감소될 경우 바닥전극의 hillock에 큰 영향을 받게 되며, 그로 인해 절연막의 두께를 감소시키는 것는 한계가 있는 것으로 보고되어 있다. 본 논문에서는 낮은 구동 전압에서 동작하고 안정된 on/pff 상태를 갖는 Al/TiO2-SiO2/Mo 형태의 안티퓨즈 소자를 제안하였다. 만들어진 antifuse cell은 0.6cm2 크기로 약 300개의 샘플을 제작하여 측정하였다. 비저항이 6-9 $\Omega$-cm인 P형의 실리콘 웨이퍼에 RF 마그네트론 스퍼터링(RF magnetron sputtering) 방법으로 하부전극인 Mo를 3000 증착하였다. SiO2는 안티퓨즈에서 완충막의 역할을 하며 구조적으로 antifuse cell을 완전히 감싸고 있는 형태로 제작되었다. 완충막 구조를 만들기 dln해 일반적인 포토리소그라피(Photo-lithography)작업을 거처 형성하였다. 형성된 hole의 크기는 5$mu extrm{m}$$\times$5$\mu\textrm{m}$ 이었다. 완충막이 형성된 기판위에 안티퓨즈 절연체인 SiO2를 PECVD 방식으로 100 증착하였다. 그 후 이중 절연막을 형성시키기 위해 LPCVD를 이용하여 TiO2를 150 증착시켰다. 상부 전극은 thermal evaporation 방식으로 Al을 250nm 증착하여Tejk. 하부전극으로 사용된 Mo 금속은 표면상태가 부드럽고 녹는점이 높은 매우 안정된 금속으로, 표면위에 제조된 SiO2의 특성을 매우 안정되게 유지시켰다. 제안된 안티푸즈는 이중절연막을 증착함으로서 전체적인 절연막의 두께를 증가시켜 바닥전극의 hillock의 영향을 적게 받아 안정성을 유지할 수 있도록 하였다. 또한, 두 절연막 사이의 계면 반응에 의해 SiO2 막을 약화시켜 절연막의 두께가 두꺼워졌음에도 기존의 SiO2 절연막의 절연 파괴 전압 및 누설 전류오 비교되는 특성을 가졌다. 이중막을 구성하고 있는 안티퓨즈의 ON-저항이 단일막과 비교해 비슷한 것을 볼 수 잇는데, 그 이유는 TiO2에 포함된 Ti가 필라멘트에 포함되어 있어 필라멘트의 저항을 감소시켰기 때문으로 사료된다. 결국 이중막을 구성시 ON-저항 증가에 의한 속도 저하 요인은 없다고 할 수 있다. 5V의 절연파괴 시간을 측정한느 TDDB 테스트 결과 1.1$\times$103 year로 기대수치인 수십 년보다 높아 제안된 안티퓨즈의 신뢰성을 확보 할 수 있었다. 제안된 안티퓨즈의 이중 절연막의 두께는 250 이고 프로그래밍 전압은 9.0V이고, 약 65$\Omega$의 on 저항을 얻을수 있었다.

  • PDF

A study on the dye wastewater treatment by Fenton oxidation process (Fenton 산화공법을 적용한 염색폐수처리 연구)

  • Ahn, June-Shu;Park, Tae-Sool;Cho, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4274-4282
    • /
    • 2011
  • In this study, Fenton reaction was studied for the possibility of applying as advanced treatment and its optimal condition for the removal of refractory organics from the dye wastewater. Fenton reaction was applied to remove refractory organics after the bio-treatment (secondary treatment) inside test laboratory and on-site pilot plant. Wastewater from the secondary treatment was used and its $COD_{Mn}$ was measured as 30~50mg/L. After the Fenton reaction, the optimal condition was found as pH 3~3.5, reaction time 2~2.5hr, chemical input ratio of ($FeCl_2$(33%)/$H_2O_2$(35%)) was 3 : 1. When chemical input ratio of ($FeCl_2$(33%)/$H_2O_2$(35%)) was at its optimal, amount of sludge volume ($SV_{2hr}$) was 21~28%. With pilot plant test, removal rate was heavily influenced by the hydraulic retention time(HRT), and optimum value of HRT was 2.0 hr. When pilot plant($2m^3/d$) was placed on-site and operated continuously, it showed steady and fairly good treatment of COD where COD removal rate was 60~70%, treated water showed below 20mg/L.

The Improvement of Electrical Point Machine Wiring Set (선로전환기(NS)의 배선세트 개선)

  • Jeong, Rag-Gyo;Park, Gun-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.351-358
    • /
    • 2016
  • An Electrical Point Machine (NS:New-type Switch), which is equipped and operated at railways in Korea, has been used since the 1960s after being imported from Japan. On the other hand, although the mechanical configuration has improved the position motor control circuit, the electrical connection has not been improved, so NS may have a problem, such as the interlocking system of automatic train operation. In addition, NS is the most vulnerable part in the railway system and a huge train accident may occur due to minor defects. The existing NS wiring set of the circuit controller should be checked only if fixed. Therefore, an excessive inspection time only by a Railroad Signal expert is required. In this paper, the improvement of electrical connection in a NS wiring set, such as the position motor control circuit, was developed and the prototype was installed at Seoul Metro in the distance to go section. The results can be used to help make appropriate adjustments. The improvement of the NS wiring set enhance the maintenance efficiency, passenger service and the stability of the signal system as well as reducing the maintenance cost.

Écoumén Ethik und der ökologische Gedanke von Land und Körper (에쿠벤 윤리, 대지와 몸의 생태사상)

  • Kim, Jyung-Hyun
    • Journal of Korean Philosophical Society
    • /
    • v.126
    • /
    • pp.1-23
    • /
    • 2013
  • Heute ist das Problem in der globalen Gesellschaft, mit dem wir uns $besch{\ddot{a}}ftigen$ sollen, die ${\ddot{o}}kologische$ Krise. Einer der Wege, um die ${\ddot{o}}kologische$ Krise zu $l{\ddot{o}}sen$, ist das Finden des ${\ddot{o}}kologischen$ Gleichgewichts des Landes und des menschlichen $K{\ddot{o}}rpers$. Dieser Aufsatz behandelt mit dem Begriff von "Salim (Haushalten und Beleben)" die Beziehung des Menschen zum Land, und die Beziehung des Landes zum menschlichen $K{\ddot{o}}rper$. In $Ankn{\ddot{u}}pfung$ an das Konzept der ${\ddot{o}}kologischen$ "Salim" laufen bei diesem Aufsatz $vielf{\ddot{a}}ltige$ Argumente wie die Beziehung des Menschen zum Land als ${\acute{e}}coum{\acute{e}}n$ Ethik, "Salim des Landes" und "Salim des $K{\ddot{o}}rpers$" zusammen. Das ${\ddot{o}}kologische$ Ungleichgewicht im 21. Jahrhundert weist darauf hin, dass die menschliche Beziehung zum Land als einem Platz der menschlichen Besiedlung bis jetzt nicht gesund war. Das Anfordern der ${\acute{e}}coum{\acute{e}}n$ Ethik von heute erweist sich, dass wir herausarbeiten $m{\ddot{u}}ssen$, die gesundliche Beziehung des Menschen zum Land wieder zu beleben. Im Kapitel 3, in $Anschlu{\ss}$ an das Konzept der ${\ddot{o}}kologischen$ "Salim" des Landes, ist die Tatsache in Betracht zu ziehen, dass das Land nicht einfach wirtschaftlichen Wert hat, sondern zur Gemeinschaft des kosmischen Lebens $geh{\ddot{o}}rt$. Mit dem Konzept der ${\ddot{o}}kologischen$ $K{\ddot{o}}rper$-Salim, versucht das Kapitel 4 darzulegen, wie der menschliche $K{\ddot{o}}rper$ im kosmischen Lebenszyklus beteiligt ist. Heute, konfrontiert mit der Amnesie vom Leben des Landes und mit dem $Sch{\ddot{a}}den$ des $K{\ddot{o}}rper-{\ddot{o}}kosystems$, sollten wir unser Bewusstsein und unsere Lebensweise $ver{\ddot{a}}ndern$ und die ${\ddot{o}}kologischen$ Salim-Bewegung in die Praxis setzen.

Evaluation of Field Applicability of Slope of Improved Soil for Ground Stabilizer (지반안정재 개량토의 토사 비탈면 현장 적용성 평가)

  • Lee, Kang-Il;Park, Seong-Bak;Choi, Min-Ju
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.1
    • /
    • pp.35-44
    • /
    • 2021
  • This research studies the stabilization method for improved soil sloped through the on-site application of Paper Flyash ground stabilizers. The target strength required for improved soil is 500 kPa, and the compressive strength for the slope surface needs to be less than 1,000 kPa after the improvement in order to plant vegetation. To meet this condition, we mixed soil from the site and the ground stabilization material, which is the main material for surface improvement material, performed mixing design and conducted various tests including strength test, permeability test and plantation test. After analyzing the results of the compression test on improved soil slope, we proposed soil constants for the improved soil. In order to evaluate the applicability of the improved soil on the slope, the site construction was carried out on the collapsed slope and the reinforcement evaluation of the surface of the improvement soil was conducted. The stability was not secured before the reinforcement, but the test shows after the reinforcement with improved soil, the safety rate is secured up to 48 hours during the raining period. In addition, the compressive strength of the improved soil at the site was secured at more than 200 kPa adhesion as planned, and the soil hardness test result was also found to be within the specified value of 18-23 mm, which increased the resistance to rainfall and ability to grow plant on the surface for improved soil.

Analysis Study on the Detection and Classification of COVID-19 in Chest X-ray Images using Artificial Intelligence (인공지능을 활용한 흉부 엑스선 영상의 코로나19 검출 및 분류에 대한 분석 연구)

  • Yoon, Myeong-Seong;Kwon, Chae-Rim;Kim, Sung-Min;Kim, Su-In;Jo, Sung-Jun;Choi, Yu-Chan;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.661-672
    • /
    • 2022
  • After the outbreak of the SARS-CoV2 virus that causes COVID-19, it spreads around the world with the number of infections and deaths rising rapidly caused a shortage of medical resources. As a way to solve this problem, chest X-ray diagnosis using Artificial Intelligence(AI) received attention as a primary diagnostic method. The purpose of this study is to comprehensively analyze the detection of COVID-19 via AI. To achieve this purpose, 292 studies were collected through a series of Classification methods. Based on these data, performance measurement information including Accuracy, Precision, Area Under Cover(AUC), Sensitivity, Specificity, F1-score, Recall, K-fold, Architecture and Class were analyzed. As a result, the average Accuracy, Precision, AUC, Sensitivity and Specificity were achieved as 95.2%, 94.81%, 94.01%, 93.5%, and 93.92%, respectively. Although the performance measurement information on a year-on-year basis gradually increased, furthermore, we conducted a study on the rate of change according to the number of Class and image data, the ratio of use of Architecture and about the K-fold. Currently, diagnosis of COVID-19 using AI has several problems to be used independently, however, it is expected that it will be sufficient to be used as a doctor's assistant.