• Title/Summary/Keyword: 개인하수 처리시설

Search Result 16, Processing Time 0.019 seconds

Design of High Strength Underground FRP Septic Tank Stiffened by Circular Steel Pipe (원형강관으로 보강된 지중매립형 FRP 개인하수 처리시설의 설계)

  • Cho, Kwang Je;Kim, Sung Bo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3A
    • /
    • pp.171-181
    • /
    • 2012
  • The design of high strength underground septic tank stiffened by steel pipe is presented and the ultimate behavior is investigated according to the full scale experiments for three types of specimens. The limitation of the current design specification are pointed out and the general design procedure of private sewage treatment facility are newly developed considering thickness of FRP shell, types of steel pipe stiffer and diaphragm wall. The direct tensile and bending test for FRP material of septic tank were performed. The increase effect of ultimate strength due to the circular steel pipe are investigated by the full scale field test and compared with the results by the finite element analysis.

Study on the Operation and Status of Private Sewage Treatment Facilities (개인하수처리시설 운영 및 실태 연구)

  • Lee, Jang-Hown;SHIN, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.2
    • /
    • pp.31-40
    • /
    • 2020
  • As private sewage treatment facilities in Korea are constantly concerned about the distribution and poor construction of defective products, minimum standards for each unit process applicable to the planning and design of sewage treatment facilities are deemed necessary. The problems and requirements of the analysis results of the operation status discussed in this study are as follows. 1) Strengthening education of supervisor of private sewage treatment facility. 2) Poor operation and management of Sewage treatment facilities. 3) A mandatory review of sewage treatment facilities for less than 2 ㎥/day of facilities other than sewage treatment zones. 4) Necessity of management of sewage treatment facility in feedstocks. 5) As a result of the technical review, Improvement plans for Ineligible facility are needed. It is also necessary to prepare a guidebook for design construction and maintenance by investigating and analyzing guidelines and data related to domestic and foreign private sewage treatment facilities.

Parametric Analysis on Ultimate Behavior of Cylindrical GFRP Septic Tank (원통형 GFRP 개인하수 처리시설의 극한거동에 대한 매개변수해석)

  • Kim, Sung Bo;Cho, Kwang Je
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1337-1347
    • /
    • 2013
  • The parametric analysis on ultimate behavior of buried cylindrical GFRP(Glass Fiber Reinforced Polymer) septic tank was presented. Two kinds of F.E. analysis model(soil-spring model and 3D full model) was constructed. The ultimate behavior of septic tank was investigated according to the size of stiffened steel ring and properties of underground soil. Ramberg-Osgood model and Druker-Prager model were used for material nonlinear characteristics of GFRP septic tank and soil, respectively. The diameter and thickness of stiffened steel ring inside septic tank, elastic modulus and internal friction angle of soil were selected for parametric variables. The ultimate behavior of septic tank, load-displacement, axial and hoop strain, were calculated and investigated.

The System Improvement of the Individual Sewage Treatment System (개인하수처리시설의 제도개선에 관한 연구)

  • Jang, Hyo-Ju;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2010
  • Individual sewage treatment system is classified into a sewage treatment system which treats all the domestic sewage and a water-purifier tank which treats only effluent flushing from the toilet. The number of registered manufacturers has increased rapidly since 2001. As a result, price competition has increased among the manufacturers and has caused the problems such as the inappropriate production of individual sewage treatment system, the unreasonable permit for building completion and the shortage of the professional technology of the community's public officials in charge. This study collected the problem cases that are related with existing individual sewage treatment system and operation. Efficient improvement plan for the stable supply, installation, maintenance of individual sewage treatment system were suggested.

Characterization of Stormwater Runoff according to Sewer System in Paldang Watershed (하수도 시스템 유무에 따른 강우유출특성 분석 - 팔당호 유역을 대상으로)

  • Kang, Dong-Han;Sajjad, Raja Umer;Kim, Keuktae;Lee, Chang-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.2
    • /
    • pp.142-148
    • /
    • 2016
  • The characterization of stormwater runoff from mix land-use catchments with an inadequate sewer network is a challenge. This study focused on characterizing stormwater runoff from the Paldang watershed area based on land-use type and sewer system coverage. A total of 76 sites were monitored during wet weather from seven different counties within Paldang watershed. Public sewer system (PSS) was installed at 48 sites, while 28 sites had no or individual sewer system (ISS) coverage. The results indicated that the sites included in the ISS group with higher forest and paddy land-use percentage exhibit higher values of average event mean concentrations (EMCs) and first flush intensity for suspended solids (SS), total nitrogen (TN), and total phosphorous (TP). In addition, upgrading runoff interception system can capture 59 % of the TP load in the first 43% of runoff within these sites. Similarly, rainfall depth and storm duration showed a positive correlation (R > 0.6) with nutrient loads within ISS group sites, as compared to PSS group. Therefore, these sites are likely to contribute higher TP and TN loads during heavier storm events and should be selected as priority management areas to combat the problem of eutrophication in Paldang reservoir.

Study on the Operation and Improvement of Excretory Treatment Facilities: Focusing on the case of Seoul City (분뇨처리시설 운영 및 개선 연구: 서울시를 중심으로)

  • Lee, Jang-Hown;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.123-130
    • /
    • 2022
  • This study was conducted to prepare a plan for the operation and improvement of excretory treatment facilities in Seoul, where the amount of excrement is expected to continue to increase due to the increase in the installation of septic tanks, a private sewage treatment facility. As a result, there are problems due to the lack of treatment capacity and increase in the amount brought in. To improve this, it is necessary to expand the overall excretory treatment facility, adjust the area of some facilities, reduce the amount of excrement through the realization of excretory units, and reduce the amount of excrement due to the change of the type of sewage treatment facility.

Occurrence of Synthetic Musk Compounds in Surface and Waste Waters in Korea (국내 하천수 및 하수처리장 유입.방류수의 합성머스크화합물 오염실태 조사)

  • Lee, In-Jung;Lee, Chul-Gu;Heo, Seong-Nam;Lee, Jae-Gwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.821-826
    • /
    • 2011
  • Synthetic musk compounds are widely used as fragrances in a variety of personal care products like soaps, sampoos, cosmetics and perfumes. The occurrence of synthetic musk compounds in municipal sewage effluent and other environmental samples could negatively impact the health of the ecosystem and humans, due to persistent and long-term chronic exposure of aquatic organisms. Fifteen synthetic musk compounds (musk ketone, musk xylene, musk ambrette, musk moskene, musk tibetene, HHCB, AHTN, ADBI, AHDI, DPMI, ATII, ethylenebrasssylate, ambretettolide, cyclopentadecanolide, OTNE) were analysed in surface waters and sewage treatment plants (STP) influents/effluents in Korea by GC/MS. Method detection limits were $0.005{\sim}0.398{\mu}g/L$. HHCB and AHTN were most frequently observed in both surface waters and STP influents/effluents.

A Study on the Application of Natural Zeolite as Coagulant Aid for Effluent Quality Improvement in Private Sewage Treatment Facility (개인하수처리시설 처리수의 수질 개선을 위한 응집보조제로서의 천연제올라이트 적용에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.121-128
    • /
    • 2012
  • The purpose of this study is to solve the problem of nutrient removal due to rapid hydraulic retention time (HRT) variation in small size private sewage treatment facility and to have better effluent quality by using natural zeolite as a coagulant aid. The experiments were conducted by applying different conditions of HRT, coagulant, and zeolite dosages. As an experimental result, $TBOD_{5}$, TSS, and TP removal efficiencies were 64.9%, 94.5%, and 98.8% at co-injection with zeolite. Overall removal efficiencies of $TBOD_{5}$, TSS, and TP have improved 15.7, 28.7, 6.1%, respectively. This result shows that zeolite addition could improve flocculation, increase setting velocity, and thus have better treatment. Therefore the use of zeolite as a coagulant aid can be useful in small size private sewage treatment facility, where especially extra nutrient removal is required to meet the legal standard for discharge.