• Title/Summary/Keyword: 개별냉방

Search Result 8, Processing Time 0.03 seconds

Study on Indoor Thermal Environment Controlled by Portable Cooler (실험을 통한 이동형 냉방기의 실내 온도분포 특성의 검토)

  • Choi, Dong-Kyun;Song, Doosam;Kim, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.49-54
    • /
    • 2016
  • The purpose of this study is to analyze the indoor temperature distribution of a room controlled by a personal and portable cooler. As an energy saving strategy, the personal air-conditioning or task conditioning system was developed and installed in office buildings in the 90 s. Many research results regarding the personal air-conditioning (PAC) system were focused on thermal comfort, localized ventilation efficiency and energy savings. However, the conventional PACs were only developed for application in office buildings. In this study, as a type of PAC, a portable cooler was analyzed in terms of indoor temperature distribution changes with the passage of time. The measurement was performed in a bedroom in an apartment house. The results showed that indoor temperature was controlled at about $24^{\circ}C$ around the human body. However, the ambient zone up to 1.5 m away from the the human body stayed at about $27.5^{\circ}C$.

A Basic Study on the District Cooling System of LNG Cold Thermal Energy (LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.36-43
    • /
    • 2003
  • This paper provides the possibility of the district cooling system by using a LNG cold thermal energy. A liquefied natural gas provides a plenty of cooling source energy during a gasification of a liquefied natural gas. In recent, an ice thermal storage system is used for cooling a building, and a deep water source cooling system has been introduced as a district cooling system in which is used to cool the office towers and other large buildings in old and new downtown. LNG cooling energy refers to the reuse of a large body of naturally cold fluids as a heat sink for process and comfort space cooling as an alternative of conventional, refrigerant based cooling systems. Coincident with significant clean energy and operating cost savings, LNG cold energy cooling system offers radical reductions in air-borne pollutants and the release of environmentally harmful refrigerants in comparison to the conventional air-conditioning system. This study provides useful information on the basic design concepts, environmental considerations and performance related to the application of LNG cold thermal energy.

  • PDF

지역냉난방 시스템

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.40
    • /
    • pp.84-95
    • /
    • 1993
  • 지역난방은 한 곳에 집중된 대규모 열원시설에서 경제적으로 생산된 열을 일정한 지역내 아파트, 빌딩, 공공 시설 등에 난방 및 냉방용으로 공급하는 도시 기반시설이다. 또한 지역난방은 개별난방이나 중앙난방의 간헐 난방방식과는 달리 24 시간 연속난방을 하므로써 건강하고 쾌적한 실내온도를 유지시켜 주며, 노후된 보일러 교체비 및 유지 보수가 들지 않고, 난방순환펌프 등 각종 부대시설의 축소로 동력비를 절감할 수 있으며 기존 보일러실을 주민복지 공간으로 활용할 수 있고, 연료탱크와 보조난방기구 등이 필요 없어 재해 발생의 우려가 없다. 본지에서는 한국지역난방공사에서 제공한 자료와 월간 설비기술에 게재된 내용을 요약 정리하여 게재한다.

  • PDF

국가 최대 전문교육훈련기관의 냉난방시설 ESCO사업으로 환골탈태

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.18
    • /
    • pp.18-21
    • /
    • 2002
  • 국가전문행정연수원은 지난해 8월부터 올 6월까지 약 10개월에 걸쳐 기존의 노후화된 증기난방 보일러와 개별 냉방기를 흡수식 냉온수기를 통한 중앙집중식 냉난방으로 전환하는 ESCO사업을 실시해 막대한 에너지 절감 효과를 보고 있다. 총 4개 건물을 대상으로 진행된 이번 냉난방 ESCO사업은 총 사업금액이 6억2천여만원에 이르며 연간 절감되는 에너지절감금액이 약 1억4천4백만원 정도여서 앞으로 5년 10개월에 걸쳐 모든 투자비가 회수될 예정이다.

  • PDF

Optimum Design of the Ground-Coupled Heat Pump Systems according to Heat Pump Unit Performance (열펌프 유닛 성능과 지열원 냉난방 시스템 설계에 관한 연구)

  • Kim, Namtae;Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.193-193
    • /
    • 2011
  • 현재까지 대부분의 지열원 열펌프 시스템에 관한 연구는 열펌프 유닛과 지중열교환기에 대해 개별적으로 수행되었으며, 열펌프 유닛과 지중열교환기 설계 및 최적화의 공통변수인 지중순환수 유량에 따른 시스템 전체에 대한 연구성과는 매우 미미한 실정이다. 본 연구에서는 현재 국내에서 인증되어 보급되고 있는 물매물 지열원 열펌프 유닛의 성능 자료를 분석하고, 지중순환수 유량 변화에 따른 물대물 열펌프 유닛의 성능 실험 및 지중열교환기 형상에 관한 설계 및 분석을 수행하여 지열원 열펌프 시스템 최적화에 관한 기반 기술 확보하고자 하였다. 현재 국내의 물대물 지열원 열펌프 유닛의 냉방 및 난방 조건에서의 최소 인증 COP는 각각 4.1과 3.45이다. 다양한 용량 및 성능을 갖는 국내 인증 물대물 지열원 열펌프 유닛에 대한 정량적 성능 분석을 위하여 3.5kW(1RT) 용량당의 지중순환수 유량과 COP를 고찰하였다. 냉방운전시 3.5kW 단위 용량당 열펌프 유닛의 지중순환수 유량은 10.73에서 18.52LPM을 나타냈으며, 난방운전에는 10.41에서 18.16LPM을 나타냈다. 이때, 냉방 COP는 4.1에서 5.4의 값을 나타냈으며, 난방 COP는 각각 3.5에서 4.2를 나타냈다. 인증 열펌프 유닛에서 지중순환수 유량과 열펌프 유닛의 냉난방 성능은 일정한 경향성을 나타내지 않았다. 지중순환수 유량에 따른 지열원 열펌프 유닛과 시스템의 성능을 정량적으로 분석하고자 지중순환수 유량 변화에 따른 물대물 지열원 열펌프 유닛 성능 실험을 수행하고 이를 기반으로 지중열교환기를 설계 및 분석하였다. 냉난방 각 운전모드에서 ISO 13256-2 규격과 NRGT 101 규격을 기준으로 지중순환수와 부하측 유량 6LPM 에서 36LPM 사이에서 변화시키며 성능 실험을 수행하였다. 냉방 및 난방모드 모두 유량이 증가함에 따라 열펌프 유닛 COP가 증가하였으나, 유량 증가에 따른 열펌프 유닛 COP 증가율은 감소하였다. 지중순환수 유량이 18LPM 이상에서는 COP 상승폭은 미소하였다. 기존문헌의 부하 산정자료와 열펌프 유닛 실험 성능 데이터를 이용하여 지식경제부 고시 2009-332호에 준하여 수직밀폐형 지중열교환기를 설계하고 순환펌프 소요동력을 이용하여 시스템 COP를 분석하였다. 지중열교환기 설계 시 국내에서 가장 많이 사용되고 있는 상용지중열교환기 설계프로그램인 GLD 프로그램을 사용하였다. 지중순환수와 부하측 2차 유체 유량 증가 시에 열펌프 유닛 COP 증가율 대비 시스템 COP 증가율은 감소하였으며, 난방모드에서는 일정 유량 이상에서는 열펌프 유닛 COP는 증가하였으나, 시스템 COP는 감소하였다. 또한, 지중순환수 유량 증가에 따라 지중열교환기 길이가 증가하였으며, 냉난방시의 지중열교환기 길이차이가 증가하였다. 지열원 열펌프 시스템의 고효율화 및 시공비 절감을 통한 경제성 확보를 위해서는 지열원 열펌프 유닛 성능과 지중열교환기 형상 공통 변수인 지중순환수 유량을 함께 고려하여 시스템을 설계하여야한다.

  • PDF

Development and Application of the Calibration Method of Individual Building Energy Consumption (개별건물 에너지소비량 보정기법 개발 및 적용방안)

  • Kim, Dongil;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.15-24
    • /
    • 2020
  • Building energy consumption generally depends on living patterns of residents and outdoor air temperature changes. Although outdoor air temperature changes effect on building energy consumption, there is no calibration method for the comparison before and after Green Remodeling or BEMS installation etc., Big data of building energy consumption are collected and managed by 『National Integrated Management System of Building Energy』 in Korea, and they are utilized for the development of a calibration method for individual buildings as shown as the calibration method for small-area building stocks in the previous research. This study aims to develope a calibration method using big data of building energy consumption of individual buildings and outdoor air temperature changes, and to propose application of appropriate calibration methods for individual buildings or small-area building stocks according to the calibration purpose and conditions.

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (지열원 멀티열펌프 시스템의 용량가변 특성 연구)

  • Cho, Chanyong;Oh, Myung Suk;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF

Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses (토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.215-224
    • /
    • 2009
  • A survey on the actual state of heating, cooling, ventilation, and air-flow and experimental measurement of temperature and humidity distribution in tomato greenhouse were performed to provide fundamental data required in the development of air-flow control technology. In single-span plastic houses, which account for most of 136 tomato greenhouses surveyed, roof windows, ventilation and air-flow fans were installed in a low rate, and installation specs of those facilities showed a very large deviation. There were no farms installed greenhouse cooling facilities. In the hot air heating system, which account for most of heating type, installation specs of hot air duct showed also a large deviation. The exhaust air temperature and wind speed in hot air duct also were measured to have a big difference depending on the distance from the heater. We are using the maximum difference as indicator to determine whether temperature distribution is uniform. However if the temperature slope is not identical in greenhouse, it can't represent the uniformity. We analyzed relation between the maximum difference and the uniformity of temperature and humidity distribution. The uniformity was calculated using the mean and standard deviation of data from 12 measuring points. They showed high correlation but were represented differently by linear in the daytime and quadratic in the nighttime. It could see that the uniformity of temperature and humidity distribution was much different according to greenhouse type and heating method. The installation guidelines for ventilation and air-flow fan, the spread of greenhouse cooling technology for year-round stable production, and improvement of air duct and heating system, etc. are needed.