• Title/Summary/Keyword: 강합성

Search Result 930, Processing Time 0.026 seconds

A Study on the Ductility of Concrete-Filled Composite Columns under Cyclic Loading (반복하중을 받는 콘크리트충전 강합성 기둥의 연성에 관한 연구)

  • 송준엽;권영봉;김성곤
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.6
    • /
    • pp.11-19
    • /
    • 2001
  • A series of test on concrete-filled composite columns was preformed to evaluate structural performance under axial compression and cyclic lateral loading. It was presented that concrete-filled composite columns had high strength, high stiffness and large energy-absorption capacity on account of mutual confinement between the steel plate and filled-in concrete. A cross section analysis procedure developed to predict the moment-curvature relation of composite columns was proven to be on accurate and effective method. The ductility factor and the response modification factor were evaluated for the seismic design of concrete-filled composite columns. It was shown that concrete-filled composite columns could be used as a very efficient earthquake-resistant structural member.

  • PDF

Behavior Characteristics of Shear Connector for Composite Behavior of Steel Composite Columns (강합성 부재의 합성거동을 위한 전단 연결재의 거동 특성)

  • Won, Deok Hee;Han, Taek Hee;Kim, Seungjun;Lee, Jung Hwa;Kang, Young Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1993-1999
    • /
    • 2013
  • Steel composite structures have been studied in various areas such as bridges, high rise buildings, and wind towers. They show excellent structural performance through overcoming of the weaknesses of steel and concrete. Although various methods were already developed to achieve full composite behavior between steel and concrete in flexural members, the number of studies regarding composite columns is quite limited. If slip occurs between concrete and steel under external loads, the performance of the composite column would be reduced significantly. Connection methods ensuring full composite action between steel and concrete must be suggested. This paper investigated about structural behavior of shear studs through a series of experimental tests. Extensive parameters were also performed to understand the effects of the diameter of stud, space of stud and height of concrete. The present study provides fundamental bases for further development of design method of shear studs in composite columns.

The composite bridge applied in Korean high speed rail project (한국 고속철도 교량에 있어서의 강합성교 적용사례)

  • 황낙연;김창환
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.257-264
    • /
    • 2001
  • 국내 고속철도 강합성 교량이 경부고속철도 8-2공구에서 처음으로 시공완료 되었다. 그동안 수년간에 걸쳐 고속철도 교량시공에도 불구하고 강합성 교량이 적용되지 못했던 것은 설계 기술적인 면과 더불어 재료 적인 면에서 국내여건이 성숙되지 못한 요인이 크다고 보여진다. 본 고에서는 기 설계된 PC BOX교량중 지형여건상 강합성교량이 적합한 교량구간을 제시하였다. 또한 강합성 교량의 설계기술적인면 중 특히 중요한 한국형 TGV차량의 동적 하중의 적용과 그에 따른 구조물 거동의 평가를 1@50 교량에 대한 8-2공구 사례를 통하여 논의하였다. 강합성 단면은 단순 2주형 주형거더(double I beam)이며 플랜지 두께는 최대 80-100mm가 적용되어졌다. 본 단면에 대한 HL차량하중등에 대한 정적해석을 통하여 관심이 되고 있는 플랜지등의 응력 검토결과를 보여주었다. 아울러 정적해석과 동적해석의 결과치를 비교하여 국내 시방서에 제시된 고속철도 HL차량하중에 대한 평가도 이루어졌다. (중략)

  • PDF

Seismic Performance of a Hollow Composite Column (강합성 중공 기둥의 내진 성능)

  • Han, Taek Hee;Kim, Jung Hun;Lim, Nam Hyoung;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.215-226
    • /
    • 2008
  • A column test was performed for a hollow composite column to evaluate its seismic performance. The seismic performances of a hollow composite column and a reinforced concrete (RC) column were evaluated and compared by quasi-static tests. Lateral displacements and lateral loads of the column specimens were measured during tests. Ductilities, absorbed energy, equivalent damping ratios, and damage indices were calculated from the recorded data. From the test results, the hollow composite column showed a seismic performance superior to the column in terms of double moment capacity, ultimate energy, and energy absorption.

Estimation of Live Load Moment for Concrete Unfilled Steel Grid Deck Using Main Bearing Bar Distribution Factor (하중분배 계수를 적용한 비충전 강합성 바닥판 활하중 모멘트 산정)

  • Park, Young hoon;Kim, Sung Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1667-1676
    • /
    • 2014
  • Because of the different flexural rigidity between longitudinal and transverse direction, orthotropic plate theory may be suitable for describing the behavior of composite deck. The ratio of flexural rigidity between longitudinal and transverse direction affects the live load moment. Because of the ratio of flexural rigidity of concrete unfilled steel grid deck has a direct relationship with main bearing bar spacing, it is concluded that the study for the distribution factor which is effected by main bearing bar spacing and aspect ratio is needed. In this study, evaluate the live load moment of concrete unfilled steel grid deck using the AASHTO LRFD Bridge Design Specification and presents the distribution coefficient equation for concrete unfilled steel grid deck.

Seismic Performance of Concrete-Filled Steel Piers Part I : Quasi-Static Cyclic Loading Test (강합성교각의 내진성능평가 Part I : 준정적 반복재하실험)

  • 조창빈;서진환;장승필
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.9-19
    • /
    • 2002
  • Steel piers and concrete-filled steel(CFS) piers, in spite of reasonable strength, high ductility, small section, and fast construction, have not been considered as one of alternatives to RC piers even in the highly populated urban area where aseismic safety, limited space and fast construction are indispensably required. This paper, the first of two companion papers for the seismic performance of steel and CFS piers, tests steel and CFS piers under quasi-static cyclic loading to estimate their ductility and strength. Additional details such as rebars and base ribs are added to increase the ductility of a concrete-filled steel pier with minimum additional cost. Also, simplified numerical analyses using nonlinear spring and shell elements are examined for the estimation of the ductility and strength of concrete-filled steel piers and a steel pier. The result shows that concrete-filled steel peirs have higher energy absorption, i.e., ductility and strength than those of steel pier and increasing bonding between in-filled concrete and lower diaphragm, and the improved details of stress concentrated region would be important for the ductility and strength of a pier. Numerical results show that simplified modeling with nonlinear springs and shells has potential to be effective modeling technique to estimate the seismic performance of a concrete-filled steel pier.

Strength and Ductility of Steel Fiber Reinforced Composite Beams without Shear Reinforcements (전단보강근이 없는 강섬유 보강 합성보의 강도 및 연성 능력)

  • Oh, Young-Hun;Nam, Young-Gil;Kim, Jeong-Hae
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.103-111
    • /
    • 2007
  • Experimental study was carried out to investigate the structural performance of composite beams with steel fiber concrete and angle. For this purpose, seven specimens composed of two RC beams with or without steel fiber and five composite beams with steel fiber and angle were constructed and tested. All specimens had no web shear reinforcement. Main variables for the specimens were tensile reinforcement ratio and fiber volume fraction. Based on the test results, structural performance such as strength, stiffness, ductility and energy dissipation capacity was evaluated and compared with the predicted strength. The prediction of flexure and shear strength gives a good relationship with the observed strength. The strength, ductility and energy dissipation capacity are increased, as the fiber volume fraction is increased. Meanwhile, high tensile reinforcement ratio resulted in the reduction of ductility and energy dissipation capacity for the composite beams.

Existing RC deck and Simplified Composite Deck Comparative Analysis Of Punching Shear Strength (기존 RC 바닥판과 초간편 강합성 바닥판의 펀칭전단강도에 대한 비교 분석)

  • Lee, Sung-Yul;Yoon, Ki-Ying;Yi, Gyu-Sei;Kim, Sang-Seup
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.33-36
    • /
    • 2009
  • 현행 도로교설계기준의 바닥판에 대한 설계방법은 휨 이론에 따라 바닥판을 단위 폭의 보로 보고 강도설계법으로 설계하고 있다. 그러나 실제 교량 바닥판의 파괴 형태는 펀칭에 의한 파괴이므로 바닥판의 극한성능은 펀칭전단강도를 토대로 평가해야 할 것이다. 하지만 기존에 연구된 결과로는 초간편 강합성 바닥판의 펀칭전단강도를 산정하기 어려워 이에 대한 연구가 필요한 실정이다. 본 연구에서는 개발된 초간편 강합성 바닥판의 펀칭전단성능을 파악하기 위하여 초간편 강합성 바닥판과 RC바닥판에 대한 펀칭전단실험을 실시하여 비교하여 보았다.

  • PDF

About Fatigue Load Conduct Analysis of Simplified Composite Deck (피로하중에 대한 초간편 강합성 바닥판의 거동 분석)

  • Lee, Sung-Yol;Yoon, Ki-Yong;Yi, Gyu-Sei;Kim, Sang-Seup
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.79.2-79.2
    • /
    • 2010
  • 실제 교량 바닥판의 거동은 반복하중에 의한 피로누적 손상에 의해 발생되므로 성능분석을 위해서는 피로 실험결과를 통한 구조거동 분석이 이루어져야 할 것이다. 이에 본 논문에서는 현재 개발 중인 초간편 강합성 바닥판의 피로성능을 파악하기 위해 일점 재하 방식으로 반복 하중을 재하 하였다. 실험체의 거동을 파악하기 위해 변위계를 설치하여 변위를 측정하였고 이 실험의 결과로 신형식 바닥판인 초간편 강합성 바닥판의 피로 파괴 양상을 알 수 있었으며 피로 곡선을 얻을 수 있었다. 하지만 바닥판의 파괴요인 중 외부 환경적 요인과 실제 차량 하중 이동을 모사한 윤하중 재하 시 피로 성능에 대한 연구가 추가로 이루어져야 할 것으로 판단된다.

  • PDF

Post-Fire Damage and Structural Performance Assessment of a Steel-Concrete Composite Bridge Superstructure Using Fluid-Structure Interaction Fire Analysis (FSI 화재해석을 이용한 강합성 교량 상부구조의 화재 후 손상 및 구조성능 평가)

  • Yun, Sung-Hwan;Gil, Heungbae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.627-635
    • /
    • 2021
  • The fire damage and structural performance of a steel-concrete composite superstructure under a highway bridge exposed to fire loading was evaluated. To enhance the accuracy and efficiency of the numerical analysis, a proposed fluid-structure interaction fire analysis method was implemented in Ansys Fluent and Ansys Mechanical. The temperature distribution and performance evaluation of the steel-concrete composite superstructure according to the vertical distance from the fire source to the bottom flange were evaluated using the proposed analysis method. From the analysis, the temperature of the concrete slab and the bottom flange of the steel-concrete composite superstructure exceeded the critical temperature. Also, when the vertical distance from the fire source was 13 m or greater, the fire damage of the steel-concrete composite superstructure was found to within a safe limit.