• Title/Summary/Keyword: 강제환기

Search Result 95, Processing Time 0.022 seconds

Performance Improvement of an Air Source Heat Pump by Storage of Surplus Solar Energy in Greenhouse (온실 내 잉여 태양열을 이용한 공기열원 히트펌프 성능향상)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Kang, Youn Ku;Kim, Chung Kil;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.328-334
    • /
    • 2013
  • A greenhouse heating system to improve heat pump performance using inside and outside air of greenhouse as a heat source selectively and cut $CO_2$ enrichment costs by delay of greenhouse ventilation was developed. In this system, thermal storage modes divided into inside circulation mode using surplus solar energy and outside circulation mode using outside air heat. The thermal storage modes were designed to be switched mutually according to inside greenhouse temperature and six temperature values were input to control the heat pump operating, thermal storage mode switching and greenhouse heating automatically. Operating characteristics of this system were tested in a plastic greenhouse of non-ventilation condition. The results of test showed that the inside circulation mode began at about 11:00 and lasted for about 210 minutes and inside greenhouse temperature was maintained between $20{\sim}28^{\circ}C$ in spite of non-ventilation. System heating COP of the inside circulation mode in the daytime was 3.35, which was 36% and 25% higher than that of the outside circulation modes in the nighttime and daytime respectively.

THE NUMERICAL SIMULATION OF HYDROGEN DIFFUSION FOR THE HYDROGEN LEAKAGE IN TUNNEL (터널 내 수소연료 자동차의 수소 누설로 인한 수소 확산에 대한 수치해석 연구)

  • Ahn, Hyuk-Jin;Jung, Jae-Hyuk;Hur, Nahm-Keon;Lee, Moon-Kyu;Yong, Gee-Joong
    • Journal of computational fluids engineering
    • /
    • v.15 no.2
    • /
    • pp.47-54
    • /
    • 2010
  • In the present study, a numerical simulation for the diffusion of hydrogen leakage of FCV(Fuel Cell Vehicle) in a tunnel was performed to aid the assessment of risk in case of leakage accident. The temporal and spatial distributions of the hydrogen concentration around FCV are predicted from the present numerical analyses. Flammable region of 4-74% and explosive region of 18-59% hydrogen by volume was identified from the present results. Factors influencing the diffusion of the hydrogen jet were examined to evaluate the effectiveness of tunnel ventilation system for relieving the accumulation of the leaked hydrogen gas. The distribution of the concentration of the leaked hydrogen for various cases can be used as a database in various applications for the hydrogen safety.

A NUMERICAL SIMULATION OF HYDROGEN DIFFUSION FOR THE HYDROGEN LEAKAGE FROM FCV IN UNDERGROUND PARKING LOT (지하주차장 내 수소연료 자동차의 수소 누설로 인한 수소 확산에 대한 수치해석 연구)

  • Choi, J.;Hur, N.;Lee, E.D.;Lee, K.B.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.477-482
    • /
    • 2011
  • In the present study, the diffusion process of hydrogen leaking from a FCV (Fuel Cell Vehicle) in an underground parking lot was analyzed by numerical simulations in order to assess the risk of a leakage accident. The temporal and spatial changes of the hydrogen concentration as well as the flammable region in the parking lot were predicted numerically. The effects of the leakage flow rate and an additional ventilation fan were investigated to evaluate the ventilation performance in the parking lot to relieve the accumulation of the leaked hydrogen gas. The present numerical analysis can provide useful information such as the distribution of the leaked hydrogen concentration for safety of various hydrogen applications.

  • PDF

Application of Forced Oscillation Technique for Pitch Dynamic Stability Derivatives of a Missile Model (미사일 모델의 피치 동안정미계수 측정을 위한 강제진동기법의 적용)

  • 김승필;조환기;백승욱
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.81-87
    • /
    • 2000
  • This paper presents an application of forced oscillation technique to measure pitch dynamic stability derivatives of a missile model in the low speed wind tunnel. The missile model is oscillated by D.C. electric servomotor with constant amplitudes and frequencies. Phase shift is determined as the difference of peak values between input and output signals from the dynamic stability balance installed at the center of gravity of the model. Stability derivatives were calculated by using phase shifts, amplitudes, forcing moments and input frequencies. Test results show the proper usage of the force oscillation technique with good damping effects.

  • PDF

The Feasibility of Natural Ventilation in Radioactive Waste Repository Using Rock Cavern Disposal Method (동굴처분 방식을 사용하는 방사성 폐기물 처분장의 자연 환기 타당성 평가)

  • Kim Jin;Kwon Sang Ki
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.183-192
    • /
    • 2005
  • Natural ventilation in radioactive waste repositories is considered to be less efficient than mechanically forced ventilation for the repository working environment and hygiene & safety of the public at large, for example, controlling the exposure of airborne radioactive particulate matter. It is, however, considered to play an important role and may be fairly efficient for maintaining environmental conditions of the repository over the duration of its lifetime, for example, moisture content and radon (Rn) gas elimination in repository. This paper describes the feasibility of using natural ventilation which can be generated in the repository itself, depending on the conditions of the natural environment during the periods of repository construction and operation. Evidences from natural cave analogues, actual measurements of natural ventilation pressures in mountain traffic tunnels with vertical shafts, and calculations of airflow rates with given natural ventilation pressures indicate possible benefits from passive ventilation for the prospective Korean radioactive waste repository. Natural ventilation may provide engineers with a cost-efficient method for heat and moisture transfer, and radon (Rn) gas elimination in a radioactive waste repository. The overall thermal performance of the repository may be improved. The dry-out period may be extended, and the seepage flux likely would be decreased.

  • PDF

A Study on the Performance of Ondol with a Ventilation System (환기시스템을 갖춘 온돌 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4047-4051
    • /
    • 2014
  • Modern apartment houses are constructed to be relatively airtight with a high heat insulation system to increase the energy efficiency. Such a system has a range of deleterious effects due to the insufficient ventilation. In this study, the ondol system, which is used as a heat source typical of winter in Korea, was set as the default system to evaluate the indoor heat environment according to the ventilation method, the factors of energy reduction by the ventilation system was analyzed. The experimental apparatus was used to simulate the ambient conditions for a certain constant temperature and humidity chamber. The experimental results showed that the supply water temperature higher air volume decreases with increasing supply air temperature in the following order: floor supply/exhaust > total heat exchange supply/exhaust > forced supply/exhaust. Through this study, the applicability of various ventilations could be examined.

Ventilation Effect of the Greenhouse with Folding Panel Type Windows (패널굴절방식 환기창 온실의 환기효과)

  • Kim, Jin-Young;Lee, Si-Young;Kim, Hyun-Hwan;Chun, Hee;Yun, In-Hak
    • Journal of Bio-Environment Control
    • /
    • v.11 no.1
    • /
    • pp.5-11
    • /
    • 2002
  • In this study, new development of natural ventilation window was accomplished to control environment of greenhouse with no use of farced ventilation during hot season. The ventilation effect of developed ventilation window was investigated in experimental greenhouse which was designed using side wall panel and folding type panel fur natural ventilation. Folding panel type ventilation window was designed to open upper part of the side wall and top of the roof using two hinges which are located bottom of the side wall and the roof panel to grab one side of each panels and guide the other side along with the guidance rail. Developed ventilation window has top ventilation part with maximum moving distance X=ι (1-cos$\theta$)=848.5 mm and side ventilation part with maximum moving distance Y=ι/2 $\times$sin$\theta$=1,184.4 mm at 45$^{\circ}$ of theoretical opening angle. It took 4.5 minutes to open roof vent fully and temperature at 1.2 and 0.8 m height decreased after 1 minute from starting opening and became equilibrium state maintaining 3-4$^{\circ}C$ difference after 2 minutes from complete opening. Air exchange rate was 15.2~39.3 h$^{-1}$ which was more than 10~15 h$^{-1}$ of continuous type and Venlo type greenhouse. The descent effect of temperature by ventilation windows was two times higher than Venlo type greenhouse.

A study on the availability of ATS system in speed augmentation (속도 향상시의 ATS 시스템 가용성 연구)

  • Kim, Yong-Kyu;Baek, Jong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.238-240
    • /
    • 2004
  • 현재 우리나라에서 사용 중인 신호시스템은 지상신호 방식인 자동폐색장치(ABS)를 사용한다 이는 선로를 패색구간으로 배분한 후, 각각의 패색 구간에 설치된 신호기에 의해 열차의 이동을 실행한다 이러한 신호체계에 문제점이 발생할 경우, 기관사에게 주의를 환기시켜 강제적으로 열차를 정지시키는 역할을 하는 자동열차정지장치(ATS)가 1969년부터 도입, 사용 중에 있다. 본 논문에서는 ATS 시스템의 고속, 고밀도 운전 적용 가능성 및 차상신호방식 사용시의 ATS 적용 가능성에 대해 분석한다.

  • PDF

Underground hot water heating system development using exhaust gas heat in the hot air heater (온풍난방기의 배기열을 이용한 지중난방용 온수시스템 개발)

  • 김영중;이건중;신정웅;유영선;장진택
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.100-103
    • /
    • 1999
  • 온풍난방은 우리 나라 대부분의 온실난방지역에서 가장 많이 채택하고 있는 온실난방방법으로 간주되고 있다. 온풍난방은 기본적으로 화석연료를 연소열로 변환시켜 온실난방에 사용하는 방법으로 온수난방, 태양열난방 보다 열효율이 높다. 가장 보편적 온실난방열원으로는 경유나 보일러등유를 연소실에서 연소하여 열교환기를 거친 후 온풍기의 상부에 부착되어 있는 송풍팬으로 강제적으로 온실 내로 온풍을 불어넣는다. (중략)

  • PDF

Effect of Aeration Rate on Production of Somatic Embryo in Oenanthe stolonifera DC. (미나리 체세포배 생산에 미치는 환기율의 영향)

  • 김진아;윤혜진;이병일;손정익
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.11a
    • /
    • pp.174-175
    • /
    • 2001
  • 미나리 묘를 대량으로 생산하는데 있어서 체세포배를 이용하는 방법이 매우 유리하다. 체세포배는 계절에 영향을 받지 않고 좁은 공간에서 한꺼번에 많은 량의 묘를 생산할 수 있다. 또한 생물반응기 등을 이용하여 대량 생산할 수 있으면 실생묘를 대체할 수 있을 것으로 생각된다. 배양기 내의 공기 환경의 영향은 삼각플라스크를 이용한 소규모 배양에서는 문제가 되지 않았지만 배양기가 커짐에 따라 공기 환경의 변화도 커져 체세포배의 발생과 발아에 영향을 미친다. 체세포배를 배양하는 기간은 배발생과 발아로 나누어, 세포에서 배가 발생하는 처음 2주 동안에는 밀폐 환경, 즉 환기가 거의 되지 않는 환경이 유리하지만 이후의 발아 동안에는 산소를 많이 요구한다. 삼각플라스크를 이용한 소규모 배양에서는 aluminum foil을 플라스크의 뚜껑으로 하여, 배지를 교체할 때를 제외하고는 배발생과 발아가 진행되는 전 배양 기간 동안 이를 유지한다. 배가 발생하는 초기 2주의 경우는 이 밀폐 환경이 발아를 촉진시킨다. 그러나 배가 발아하여 정상 식물체로 발달하는데는 유리하지 않다. 체세포배는 발아할 때 산소를 많이 필요로 하며 에틸렌이 많이 축적되면 발아율이 낮아지며, 적절한 공기 환경이 주어지면 체세포배 발아가 동조화되어 균일한 묘를 얻을 수 있고 수확시기도 예측할 수 있다. 본 실험에서는 배가 발아하는 기간 동안 플라스크 내의 공기 환경을 다르게 하기 위해 플라스크를 막는 뚜껑의 소재를 달리하여 배양한 후 발아율을 측정하였다. 또한 가장 효율적인 환기량을 구명하기 위하여 인위적으로 플라스크에 공기를 넣어 강제 환기시키는 실험을 수행하였다. 미나리 cell은 처음 8일까지는 생장을 하지 않다가 이후 급속히 생장을 시작하여 35일 정도까지는 생장을 하다가 다시 생장이 둔화되었다. 밀폐시킨 삼각플라스크에서 자라는 Cell은 상태도 좋지 않고 전반적인 증식량도 적었다. Cell은 환기정도에 민감한 것으로 판단되며 삼각플라스크에서 약 35일 정도의 생장 주기를 가지는 것으로 사료된다. 배양 3주까지는 플라스틱 뚜껑으로 밀폐시킨 bottle에서 가장 많은 체세포배를 얻었다. Air filter를 달아 2일 마다 신선한 공기를 넣어 주었을 때는 배의 발달이 많이 늦어져 배양 3주째에 다른 처리보다 배의 수가 훨씬 적었다. 체세포배가 발달하는 동안에는 산소를 많이 요구하지 않으나 성숙하는 동안에는 산소를 많이 요구하는 것으로 생각된다.

  • PDF