• Title/Summary/Keyword: 강인 제어

Search Result 2,344, Processing Time 0.027 seconds

Study on the Selecting of Suitable Sites for Integrated Riparian Eco-belts Connecting Dam Floodplains and Riparian Zone - Case Study of Daecheong Reservoir in Geum-river Basin - (댐 홍수터와 수변구역을 연계한 통합형 수변생태벨트 적지 선정방안 연구 - 금강 수계 대청호 사례 연구 -)

  • Bahn, Gwonsoo;Cho, Myeonghyeon;Kang, Jeonkyeong;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.23 no.4
    • /
    • pp.327-341
    • /
    • 2021
  • The riparian eco-belt is an efficient technique that can reduce non-point pollution sources in the basin and improve ecological connectivity and health. In Korea, a legal system for the construction and management of riparian eco-belts is in operation. However, it is currently excluded that rivers and floodplains in dam reservoir that are advantageous for buffer functions such as control of non-point pollutants and ecological habitats. Accordingly, this study presented and analyzed a plan to select a site for an integrated riparian ecol-belt that comprehensively evaluates the water quality and ecosystem characteristics of each dam floodplain and riparian zone for the Daecheong Dam basin in Geum River watershed. First, the Daecheong Dam basin was divided into 138 sub-basin with GIS, and the riparian zone adjacent to the dam floodplain was analyzed. Sixteen evaluation factors related to the ecosystem and water quality impact that affect the selection of integrated riparian eco-belt were decided, and weights for the importance of each factor were set through AHP analysis. The priority of site suitability was derived by conducting an integrated evaluation by applying weights to sub-basin by floodplains and riparian zone factors. In order to determine whether the sites derived through GIS site analysis are sutiable for actual implementation, five sites were inspected according to three factors: land use, pollution sources, and ecological connectivity. As a result, it was confirmed that all sites were appropriate to apply integrated riparian ecol-belt. It is judged that the riparian eco-belt site analysis technique proposed through this study can be applied as a useful tool when establishing an integrated riparian zone management policy in the future. However, it might be necessary to experiment various evaluation factors and weights for each item according to the characteristics and issues of each dam. Additional research need to be conducted on elaborated conservation and restoration strategies considering the Green-Blue Network aspect, evaluation of ecosystem services, and interconnection between related laws and policy and its improvements.

Application of deep learning method for decision making support of dam release operation (댐 방류 의사결정지원을 위한 딥러닝 기법의 적용성 평가)

  • Jung, Sungho;Le, Xuan Hien;Kim, Yeonsu;Choi, Hyungu;Lee, Giha
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1095-1105
    • /
    • 2021
  • The advancement of dam operation is further required due to the upcoming rainy season, typhoons, or torrential rains. Besides, physical models based on specific rules may sometimes have limitations in controlling the release discharge of dam due to inherent uncertainty and complex factors. This study aims to forecast the water level of the nearest station to the dam multi-timestep-ahead and evaluate the availability when it makes a decision for a release discharge of dam based on LSTM (Long Short-Term Memory) of deep learning. The LSTM model was trained and tested on eight data sets with a 1-hour temporal resolution, including primary data used in the dam operation and downstream water level station data about 13 years (2009~2021). The trained model forecasted the water level time series divided by the six lead times: 1, 3, 6, 9, 12, 18-hours, and compared and analyzed with the observed data. As a result, the prediction results of the 1-hour ahead exhibited the best performance for all cases with an average accuracy of MAE of 0.01m, RMSE of 0.015 m, and NSE of 0.99, respectively. In addition, as the lead time increases, the predictive performance of the model tends to decrease slightly. The model may similarly estimate and reliably predicts the temporal pattern of the observed water level. Thus, it is judged that the LSTM model could produce predictive data by extracting the characteristics of complex hydrological non-linear data and can be used to determine the amount of release discharge from the dam when simulating the operation of the dam.

Statistical Analysis of Operating Efficiency and Failures of a Medical Linear Accelerator for Ten Years (선형가속기의 10년간 가동률과 고장률에 관한 통계분석)

  • Ju Sang Gyu;Huh Seung Jae;Han Youngyih;Seo Jeong Min;Kim Won Kyou;Kim Tae Jong;Shin Eun Hyuk;Park Ju Young;Yeo Inhwan J.;Choi David R.;Ahn Yong Chan;Park Won;Lim Do Hoon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.186-193
    • /
    • 2005
  • Purpose: To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2l00C over a ten year period were retrospectively analyzed. Materials and Methods: The failures were classified according to the involved functional subunits, with each class rated Into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Results: Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for $20\%$ of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and $83\%$ of the expected values, respectively. The operating efficiency was maintained at $95\%$ or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. Conclusion: The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. Wore rigorous equipment maintenance Is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the qualify of patient treatment.

Results of Radiation Therapy for Carcinoma of the Uterine Cervix (자궁경부암의 방사선치료 성적)

  • Lee Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.359-368
    • /
    • 1995
  • Purpose : This is a retrospective analysis for pattern of failure, survival rate and prognostic factors of 114 patients with histologically proven invasive cancer of the uterine cervix treated with definitive irradiation. Materials and Methods : One hundred fourteen patients with invasive carcinoma of the cervix were treated with a combination of intracavitary irradiation using Fletcher-Suit applicator and external beam irradiation by 6MV X-ray at the Ewha Womans University Hospital between March 1982 and Mar 1990. The median age was 53 years(range:30-77 years). FIGO stage distribution was 19 for IB, 23 for IIA, 42 for IIB, 12 for IIIA and 18 for IIIB. Summation dose of external beam and intracavitary irradiation to point A was 80-90 Gy(median:8580 cGy) in early stage(IB-IIA) and 85-100 Gy(median:8850 cGy) in advanced stage(IIB-IIIB). Kaplan-Meier method was used to estimate the survival rate and multivariate analysis for progrostic factors was performed using the Log likelihood for Weibull Results : The pelvic failure rates by stage were $10.5{\%}$ for IB. $8.7{\%}$ for IIA, $23.8{\%}$ for IIB, $50.0{\%}$ for IIIA and $38.9{\%}$ for IIIB. The rate of distant metastasis by stage were $0{\%}$ for IB, $8.7{\%}$ for IIA, $4.8{\%}$ for IIB. $0{\%}$ for IIIA and $11.1{\%}$ for IIIB. The time of failure was from 3 to 50 months and with median of 15 months after completion of radiation therapy. There was no significant coorelation between dose to point A($\leq$90 Gy vs >90 Gy) and pelvic tumor control(P>0.05). Incidence rates of grade 2 rectal and bladder complications were $3.5{\%}$(4/114) and $7{\%}$(8/114), respectively and 1 patient had sigmoid colon obstruction and 1 patient had severe cystitis. Overall 5-year survival rate was $70.5{\%}$ and disease-free survival rate was $53.6{\%}$. Overall 5-year survival rate by stage was $100{\%}$ for IB, $76.9{\%}$ for IIA, $77.6{\%}$ for IIB $87.5{\%}$ for IIIA and $69.1{\%}$ for IIIB. Five-rear disease-free survival rate by stage was $81.3{\%}$ for IB, $67.9{\%}$ for IIA, $46.8{\%}$ for IIB, $45.4{\%}$ for IIIA and $34.4{\%}$ for IIIB. The prognostic factors for disease-free survival rate by multivariate analysis was performance status(p= 0.0063) and response rate after completion of radiation therapy(p= 0.0026) but stage, age and radiation dose to point A were not siginificant. Conclusion : The result of radiation therapy for early stage of the uterine cervix cancer was relatively good but local control rate and survival rate in advanced stage were poor inspite of high dose irradiation to point A above 90 Gy. Prospective randomized studies are recommended to establish optimal tumor doses for various stages and volume of carcinoma of uterine cervix, And ajuvant chemotherapy or radiation-sensitizing agents must be considered to increase the pelvic control and survival rate in advanced cancer of uterine cervix.

  • PDF