• Title/Summary/Keyword: 강성 저감

Search Result 192, Processing Time 0.021 seconds

A Study on the Settlement Restraint of the Granular Compaction Pile (조립토 다짐말뚝의 침하저감방안에 관한 연구)

  • Kim, Seung-Wook;Lee, Duck-Won;Kim, Seo-Ryong;Ann, Jai-Gyoo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.336-342
    • /
    • 2005
  • Stone column or granular compaction pile have been used in widely during the several decades as a technique to reinforce soft cohesive soils and increase bearing capacity, accelerate consolidation settlement of the foundation soil. The bearing capacity of the granular compaction pile is governed mainly by the lateral confining pressure mobilized in the native soft soil to restrain bulging collapse of the granular pile. Therefore, the technique becomes unfeasible in soft, compressible clayey soils that do not provide sufficient lateral confinement. This paper presents the main results of numerical study of granular compaction pile which is partly mixed with lean concrete. 3D finite element analyses are performed with composite reinforced foundations by both granular compaction pile and partly mixed granular compaction pile with lean-mixed concrete.

  • PDF

Study on Elevator Induced Structural Vibration Reduction Performance Using Polymer Concrete (폴리머 콘크리트를 이용한 엘리베이터 기인 구조 진동저감 성능 연구)

  • Yeom, Jihye;Kim, Jeong-Jin;Park, Junhong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.90-94
    • /
    • 2021
  • With the increased interest on quiescent place for residential place, the noise generation from facilities needs to be minimized. One important noise source include sounds from operation of elevators. The elevator operates between floors and generates significantly annoying sounds to the nearby living spaces. It is recognized as the significant contributor inducing noise annoyance to residents. Elevator is supported to the building structure at several locations for movements between floors. In this study, the vibration reduction by use of polymer concrete on the support location was demonstrated. By measuring and comparing the vibration generation when supported on cement and polymer concrete, the noise reduction performance was evaluated. The polymer concrete was made in the form of being inserted into the wall that imitates the hoistway. The impact vibration was induced to the bracket and vibration transfer magnitude was measured. The damping ratio was evaluated through normalization and curve fitting of transient response, and comparison was performed for each resin mixing ratio. By use of polymer concrete, it was possible to reduce the vibration generation in an effect manner without sacrifice on the structural rigidity.

Analysis of Sulfate Concentration Reduction Using Enzyme Induced Carbonate Precipitation Technique (EICP 공법을 활용한 황산염 농도 저감 분석)

  • Kim, Junghoon;Kim, Daehyun;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.8
    • /
    • pp.7-16
    • /
    • 2023
  • This study aimed to evaluate the sulfate removal capacity of the enzyme-induced carbonate precipitation (EICP) technique through the chemical precipitation of sulfate with calcium ions. The optimal EICP recipe was obtained to retain the excess calcium cations in the solution for the generation of a sufficient amount of calcium carbonate (CaCO3) mineral. The effect of gypsum precipitation on the EICP-treated sand specimen was investigated by measuring the shear wave velocity and by visual inspection via scanning electron microscopy. The EICP solution using soybean crude urease, as an alternative to laboratory-grade purified urease, exhibited a lower sulfate removal efficiency at a similar CaCO3 production rate compared with the optimal EICP recipe because of soybean impurities.

The Study of Noise Reduction Method for Vacuum Cleaner Fan Motor (진공청소기용 팬모타의 소음저감대책에 관한 연구)

  • 최인환;채희권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.67-72
    • /
    • 1994
  • 현재 가전제품의 개발방향은 고효율화, 다기능화와 더불어 환경문제를 고려하는 방향으로 진행되고 있다. 환경문제로는 여러가지가 거론되고 있는데 제품의 소음에 대한 문제도 이제는 성능의 관점에서와 더불어 환경의 문제로도 인식되어야 한다고 생각한다. 특히 고속의 팬종류가 사용되는 가전제품에 있어서 저소음 성능은 판매력에 직접영향을 미치는 중요 판매전략으로 대두되고 있는 상황이다. 진공청소기는 가전제품중에서 매우 시끄러운 제품중에 속한다. 그 이유는 모타가 분당 30,000회 이상의 고속회전을 하면서 축에 연결되어 잇는 임펠러를 회전시켜 공기를 흡입, 배출시키는 일련의 작동을 하면서 여러가지 진동 및 유체소음을 일으키기 때문이다. 팬모타에서 발생한 소음과 진동은 여러가지 복잡한 전달경로를 거쳐서 외부로 전달되어진다. 따라서 청소기의 전체적인 소음을 감소시키기 위한 대책으로는 크게 두가지 방법으로 나누어 생각해 볼 수 있는데, 그 첫번째가 주된 소음원인 팬모타의 소음특성을 개선하는 방법이고 다른 하나는 팬모타로부터 발생된 소음이 밖으로 전달되는 경로를 적절하게 차단하는 방법으로서 청소기 내부에서 여러가지 방법을 사용하여 소음을 저감시키는 방법이다. 본 연구에서는 첫번째 방법인 팬모타의 소음을 감소시키는 대책들에 대하여 중점적으로 기술하려고 한다. 그 이유는 청소기 내부의 구조개선을 통하여 소음을 저감시키는 방법은 그동안 많이 실시되어 실험결과들이 축적되어 있는 반면 그 방법의 실시에는 구조적인 문제점 등 한계가 있기 때문에 더욱 조용한 청소기를 개발하기 위하여는 주된 소음원인 팬모타의 소음을 낮추어야 할 필요가 절실하게 요구되고 있기 때문이다.래그(drag) 토크의 영향과 치타음 저감을 위한 개선된 클러치 특성을 제시하였다. 클러치는 동력을 전달 또는 차단하는 기능 뿐만 아니라 엔진이나 변속기에서 발생하는 소음이나 진동을 저감시키는 기능을 가지고 있다. 따라서 엔진 공회전시에 발생하는 치타음(rattle noise)이나 비틀림 진동을 저감시키는 방법으로는 여러가지가 있으나 클러치 디스크(clutch disc)의 비틀림 기구의 설계 인자들을 적절히 조절함으로써 변속기의 인풋기어에 전달되는 비틀림 진동을 저감시키는 방법이 일반적으로 수행되어지고 있다. 본 연구는 4 실린더 4 싸이클 1.5L 엔진을 장착한 경승용차의 실차실험을 통해 공회전시 엔진 플라이휘일과 인풋기어에서의 회전수 변동을 측정하고, 이 실험 데이타를 기초로 하여 엔진 토크 및 변속기에서의 드래그 토크를 계산하여 엔진-변속기 인풋기어의 반한정계 2자유도 진동모델과 비틀림 특성을 가진 클러치 디스크의 프리댐퍼 영역에 대해 시뮬레이션을 수행하여 클러치 비틀림 기구의 설계인자인 비틀림 강성, 히스테리시스 토크에 따른 비틀림 진동 저감 효과를 연구하고자 한다.성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile where

  • PDF

Active Control System for Mitigation of Cable Vibration in Cable-Stayed Bridges (사장교 케이블 진동저감을 위한 능동제어시스템)

  • Hwang, In-Ho;Jeong, Cheol-Oh;Lee, Jong-Han;Lee, Jong-Seh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.557-563
    • /
    • 2007
  • Rain-wind induced cable vibration can cause serious problems in cable-stayed bridge. External dampers attached to the cables have become widely accepted as an effective means for stay-cable vibration suppression. For very long stay-cables, however, such damper systems are rendered ineffective, as the dampers need be attached near the end of cables for aesthetic reasons. A recent study by the authors proposed that a movable anchorage system is replaced direct fixed support of the cable with a support through a bearing and damper. This paper extends the previous work by adding active control system to mitigate the cable vibration. The response of a cable with the proposed active control system is obtained and then compared to those of the cable with and without an external passive damper. The results show that the active control system can provide superior protection than the passive control system for a cable vibration.

The design of fuzzy controller for a stand-by power saving of elevators (엘리베이터의 대기 전력 저감을 위한 퍼지제어기 설계)

  • Won, Hwa-Yeon;Kang, Sung-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2368-2374
    • /
    • 2013
  • Elevator power consists of power consumption in stand-by and in service. This paper designed a fuzzy controller saving stand-by power of elevators in a way that calculates the adequate number of elevators by the variable traffic volume of passenger and then powers off elevators being out of service. Also, the fuzzy controller was designed to minimize a increase of the average passenger's waiting time by the limited number of elevators in service. When the fuzzy controller designed in this paper was applied to the group elevator experimental device, The passenger's waiting time increased approximately 7.5%~9.5%, While the stand-by power saving is expected to be about 675KWh a day per unit and about 236.6KWh a year per unit.

Evaluation of Behaviors in Abutment Transition Zone Depending on Constrution Orders and Number of Piles (뒤채움 시공순서 및 말뚝 수에 따른 교대 접속부 거동평가)

  • Kim, Ung-Jin;Jeong, Rag-Gyo;Kim, Dae-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • The RAR (Reinforced Abutment for Railways) is an economical abutment to reduce the settlement of a transitional zone and horizontal displacement of an abutment by constructing backfill before the abutment. In this paper, the performance of the RAR depending on the pile installation was evaluated using 2D (Dimensional) finite element analysis and compared with the existing abutment (with 5 rows pile). Numerical analysis showed that increasing pile installation is more effective in reducing horizontal displacement and earth pressure than settlement of the transitional zone. The horizontal displacement and earth pressure of the RAR was approximately 26~37% and 59~83% compared to the existing abutment by changing the pile installation. More pile installation led to a greater reduction of the horizontal displacement and earth pressure of the RAR. In addition, the horizontal earth pressure of RAR is influenced considerably by the reinforcement, pile, foundation, and stiffness of the ground.

A Physical Properties of Lightweight Foamed Concrete According to Lightweight Aggregate Types and Foaming agent Types (경량골재와 기포제 종류에 따른 경량기포 콘크리트의 물리적 특성)

  • Kim, Ha-Seog;Lee, Sea-Hyun;Sun, Jung-Soo;Kim, Jin-Man
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.435-444
    • /
    • 2016
  • In Korea, approximately 48% of all households live in apartments, which are a form of multi-unit dwellings, and this figure increases up to 58%, when row houses and multiplex houses are included. As such, majority of the population reside in multi-unit dwellings where they are exposed to the problem of floor impact noise that can cause disputes and conflicts. Accordingly, this study was conducted to manufacture a high-weight, high-stiffness foamed concrete in order to develop a technology to reduce the floor impact noise. For the purpose of deriving the optimum mixing ratio for the foamed concrete that best reduces the floor impact noise, the amounts of the foaming agent, lightweight aggregate and binder were varied accordingly. Also, the target characteristics of the concrete to be developed included density of over $0.7t/m^3$, compressive strength of over $2.0N/mm^2$ and thermal conductivity of under 0.19 W/mK. The results of the experiment showed that the fluidity was very excellent at over 190 mm, regardless of the type and input amount of foaming agent and lightweight aggregate. The density and compressive strength measurements showed that the target density and compressive strength were satisfied in the specimen with 50% foam mixing ratio for foamed concrete and in all of the mixtures for the lightweight aggregate foamed concrete. In addition, the thermal conductivity measurements showed that the target thermal conductivity was satisfied in all of the foamed concrete specimens, except for VS50, in the 25% replacement ratio case for Type A aggregate, and all of the mixtures for Type B aggregate.

Vibration and Impact Transmission for each Variable of Woodpile Metamaterial (우드파일 메타물질의 변수 별 진동 및 충격에 끼치는 영향)

  • Ha, Young sun;Hwang, Hui Y.;Cheon, Seong S.
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.155-160
    • /
    • 2021
  • Metamaterials are complexes of elements that can create properties not found in naturally occurring materials, such as changing the direction of forces, creating negative stiffness, or altering vibration and impact properties. In the case of wood pile metamaterials that are easy to manufacture and have excellent performance in reducing vibration and shock in the vertical direction, basic research on variables affecting shock transmission is needed to reduce shock. Although research on impact reduction according to geometrical factors is being conducted recently, studies on the effect of material variables on impact reduction are insufficient. In this paper, finite element analysis was carried out by variablizing the geometrical properties (lamination angle, diameter, length) and material properties (modulus of elasticity, specific gravity, Poisson's ratio) of wood pile cylinders. Through finite element analysis, the shape of the wooden pile cylinder delivering impact was confirmed, and the effect of each variable on the reduction of impact force and energy was considered through main effect diagram analysis, and frequency band analysis was performed through fast Fourier transform. proceeded In order to reduce the impact force and vibration, it was found that the variables affecting the contact area of t he cylinder have a significant effect.

Experimental Study on Vibration Reduction Characteristics of Polymer Concrete (폴리머 콘크리트의 진동저감 특성에 대한 실험적 연구)

  • Kim, Jeong-Jin;Shim, Hak-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.58-65
    • /
    • 2019
  • Polymer concrete is expected to be widely used as a building material because it has a shorter hardening time and excellent compression, tensile, bending, bond strength, frictional resistance and abrasion loss compared to general concrete. The polymer concrete has excellent vibration damping performance and research on the use of various reinforcing materials is being conducted. However, in order to completely replace the general concrete and the general anti-vibration reinforcement, such polymer concrete requires an overall review of vibration reduction performance considering physical properties, dynamic properties, productivity and field applicability. In this study, the physical and dynamic properties of polymer concrete by epoxy mixing ratio were compared with those of general concrete. It was appeared that compression, tensile, bending and bond strengths of polymer concrete by epoxy mixing were significantly higher than those of general concrete. Especially, the tensile strength was more than 4 ~ 6.5 times. Based on the basic physical properties of polymer concrete, the damping ratio, which is a dynamic characteristic according to the epoxy mixing ratio, was derived through analytical models and experiments. As a result, the dynamic stiffness of polymer concrete was 20% higher than that of general concrete and the loss rate was about 3 times higher.