• Title/Summary/Keyword: 강선

Search Result 334, Processing Time 0.034 seconds

Development of Evaluation Method of External Tendon Force by Using the Deriving Ultrasonic Pulse (유도초음파를 이용한 외부 강선의 긴장력 평가기법 개발)

  • Park, Seung-Bum;Hong, Sung-Su;Yoo, Sung-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.181-192
    • /
    • 2007
  • In domestic case, there are no results of corresponding researches for measuring external tendon force. The purpose of the present paper is therefore to measure external tendon force by using deriving ultrasonic method. For this purpose, we designed and manufactured wedges and test system, and measured ultrasonic pulse velocity and pulse amplitude. By using measured data, we tried to analyze the characteristics of tendon force, and to derive the relationship between tendon force and ultrasonic pulse velocity, finally to develop the technic of measuring system using ultrasonic pulse velocity. So tendon force-velocity relationship was proposed by equations, and those equations of which errors were 3.92~8.77% will be possible to adapt in-site.

Treatment of Distal Clavicular Fracture by Reconstruction Plate and Wire Fixation (쇄골 원위부 골절에 대한 재건 금속판과 강선 고정술을 이용한 치료)

  • Suh, Mu-Sam;Kim, Sang-Hyo;Park, Hyeong-Taek
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.58-62
    • /
    • 2006
  • Purpose: To evaluate the result of operative treatment with plate and wire fixation for fractures of the distal clavicle. Materials and Methods: We assessed 9 cases of fractures of the distal clavicle that were treated by plate and wire fixation from March 2001 to July 2003 and followed up over 1year. We used the reconstruction plate as a buttress and performed cerclage wiring to fix comminuted fracture site. The functional result of shoulder was evaluated by the scoring system of Rowe. Results: The average periods of bony union was 9 weeks in all cases. According to Rowe scoring system, the functional result was exellent in 7 cases and good in 2 cases. There was no LOM of shoulder and traumatic arthritis in AC joint. But there was skin irritation in 1 case. Conclusion : The operative method by reconstruction plate and wire fixation for distal clavicular fracture was useful when there were comminuted fracture. This method seems to be simple and satisfactory in terms of improvement of range of motion of shoulder, restoration of function and rare complication.

  • PDF

Detection of Fracture Signals of Low Prestressed Steel Wires in a 10 m PSC Beam by Continuous Acoustic Monitoring Techniques (연속음향감지기법을 이용한 긴장력이 감소된 10 m PSC보의 PS 강선 파단음파 감지)

  • Youn, Seok-Goo;Lee, Chang-No
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.113-122
    • /
    • 2010
  • Corrosion of prestressing tendons and wire fractures in grouted post-tensioned prestressed concrete bridges have been considered as a serious safety problem. In bridge evaluation the condition of prestressing tendons should be inspected, and if corroded tendons are found, the loss of tendon area should be included when we calculate the ultimate strength. In the previous study, it was evaluated that continuous acoustic monitoring techniques could be considered as a reliable non-destructive method for detecting wire fractures of fully grouted post-tensioned prestressing tendons. In the present study, an experimental test was performed for detecting wire fractures of post-tensioned prestressing tendons which are prestressed lower than current design level. A 10 m prestressed concrete beam was fabricated, which included two tendons prestressed 66 percentage and 40 percentage of tensile strength, respectively. The corrosion of two tendons was induced by an accelerated corrosion equipment and the test beam was monitored by using seven acoustic sensors and a continuous acoustic monitoring system. From each prestressing tendon, two acoustic signals of wire fractures were successfully detected and source locations were estimated within 20 mm error. Based on the test results, it is considered that continuous acoustic monitoring techniques can be applied to detect low-prestressed wire fracture in fully grouted post-tensioned prestressed concrete beams.

Double Tension Band Osteosynthesis in Intra-articular Fractures of the Distal Humerus (AO type C) in Elderly Osteoporotic Patients (고령 환자의 상완골 원위부 AO-C형 골절에서 이중 강선 장력대 고정술)

  • Cheon, Sang Jin;Lee, Dong Ho;Goh, Tae Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.33-39
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the clinical result of intra-articular fractures of the distal humerus (AO type C) in elderly osteoporotic patients treated with double tension band osteosynthesis. Materials and Methods: From January 2006 to December 2010, 10 elderly osteoporotic patients(1 male, 9 females) with intra-articular fractures of the distal humerus (AO type C) were treated with double tension band osteosynthesis. The mean age of patients at the time of surgery was 74.6(66~84) years and the mean follow-up period was 39.2(20~74) months. The fracture union and complications were assessed and the functional result was evaluated by the rating system of Jupiter et al. and the Mayo elbow performance index. Results: Bone union was achieved in all patients with no secondary displacement. The mean time for union was 16.6(13~22) weeks. The average postoperative arc of elbow flexion was 119(100~140) degrees with a mean flexion contracture of 8.5(0~15) degrees. The recovery in two patients was rated as excellent, in 7 as good, and in 1 as fair in terms of the Mayo elbow performance index with average value of 82(70~90) points. Seven patients were rated as excellent, 1 as good, and 2 as fair in terms of the rating system of Jupiter et al. Changing tension band wiring was performed in one patient as skin irritation was noticed due to tension band knots. Heterotopic ossification developed in one patient but had no symptom. Conclusion: Double tension band osteosynthesis in intra-articular fractures of distal humerus (AO type C) in elderly osteoporotic patients can provide sufficient and secure stability to allow early rehabilitation.

Clinical and Radiological Outcomes of 'Blocking Kirschner Wire Technique' in Displaced Intra-Articular Calcaneal Fractures via the Extended Sinus Tarsi Approach (전위된 관절 내 종골 골절에서 확장된 족근동 접근법을 통한 Kirschner Wire 강선 지지대 고정술의 임상 및 영상학적 결과)

  • Lee, Jeong-Kil;Kang, Chan;Kim, Sang-Bum;Lee, Gi-Soo;Hwang, Jung-Mo;An, Byung-Kuk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.224-233
    • /
    • 2021
  • Purpose: The purpose of this study was to retrospectively evaluate the effect of 'Blocking Kirschner Wire (K-Wire) Technique', which has been developed to reduce protrusion of the lateral wall, in maintaining the level of reduction through clinical and radiological outcomes. Materials and Methods: Twenty-two patients with displaced intra-articular calcaneal fractures who used the blocking K-wire to maintain reduction (group A) and 44 patients that did not use blocking K-wire and were paired in 1:2 ratio with those Group A patients (group B), between January 2015 and December 2017 were enrolled in the study. All surgical procedures were performed via the extended sinus tarsi approach, and internal fixation using cannulated screws, Steinmann pins and K-wires was performed. American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot scale and postoperative recovery of exercise ability were compared for postoperative clinical outcomes. The radiological results were compared the Böhler angle, Gissane angle, calcaneal height and width, step off of posterior calcaneal joint, and the degree of protrusion of the lateral wall. Moreover, postoperative complications in both groups were compared. Results: There were no significant differences in the clinical outcomes of the two groups (p=0.924, p=0.961). The amount of Böhler angle, Gissane angle, calcaneal height and width, and step off of posterior calcaneal joint from the radiological results was not significantly different between the two groups (p=0.170, p=0.441, p=0.230, p=0.266, and p=0.400). However, the degree of protrusion of the lateral wall was 1.78 mm and 4.95 mm in group A and group B, respectively, and the difference between the two groups was significant (p=0.017). Although sural nerve entrapment and painful exostosis were more frequent in group B, they were occurred in a non-significant manner (p=0.293, p=0.655). Conclusion: Most of the clinical and radiological results as well as the complications were not significantly different between the two groups. However, the degree of protrusion of the calcaneus lateral wall in group A was promising. The 'Blocking K-Wires Technique' established by the authors may be an effective surgical option for maintaining the reduction of the lateral wall protrusion in displaced intraarticular calcaneal fractures.

Evaluation of Ultimate Tendon Stress in Prestressed Concrete Members with External Unbonded Tendons (외부 비부착 강선을 가진 부재의 극한 강선응력 평가)

  • 오병환;유성원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.381-386
    • /
    • 1999
  • The member with external unbonded tendon has two remarkable characteristics, i.e., eccentricity variation and slip by friction force at deviators, compared with internal bonded or unbonded member. An efficient numerical procedure for the nonlinear analysis of prestressed concrete beam with external unbonded tendon considering two remarkable characteristics is formulated and corresponding computer code is developed. On the basis of statistical process of parametric study results, strain compatibility method, eccentricity variation predictor and tendon stress predictor at ultimate state are proposed and verified with test results and existing Codes, which can evaluate flexural behavior at ultimate state. Finally, the proposed procedure and predictors can be efficiently used for the realistic and accurate analysis of prestressed concrete members with external unbonded tendons.

  • PDF