• Title/Summary/Keyword: 강도저감계수

Search Result 100, Processing Time 0.027 seconds

Reliability Analysis of Concrete Filled Carbon Composite Tube (탄소 섬유관으로 구속된 콘크리트 부재의 신뢰성 해석)

  • Kim, Hee-Cheul;Lee, Kyoung-Hun;Hong, Won-Kee;Lee, Young-Hak;Eom, Chul-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.1-9
    • /
    • 2006
  • In this study, axial and lateral loading experiments for both circular and square plain concrete columns confined with carbon fiber tube manufactured by carbon filament winding technique were performed. Based on the test results, reliability analyses to estimate strength reduction factors were carried out by utilizing Monte Carlo technique. CASE I was for plain concrete columns confined with the carbon tubes, CASE II was for reinforced concrete columns confined with the carbon tubes. As results, the strength reduction factors, ${\phi}$, were estimated as 0.7 for CASE I and 0.85 for CASE II respectively.

Performance Evaluation of Eco-friendly Permeable Block Using Basalt Waste Rock (현무암 폐석을 이용한 친환경 투수블록의 성능평가)

  • Sang-Soo Lee;Hyeong-Soon Kwon;Jae-Hwan Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.299-306
    • /
    • 2023
  • Environmental pollution problems are occurring due to the negative treatment of basalt waste in Jeju Island. This study identifies the characteristics of permeable block with basalt with physical and chemical adsorption mechanisms and examines their applicability and functionality as building materials. This experiment is basic data for evaluating the functionality of the permeable block by analyzing flexural strength, compressive strength, permeability coefficient, carbon dioxide, and fine dust adsorption rate by producing a permeable block using a basalt waste rock. As the basalt waste stone replacement rate increased, the flexural strength and compressive strength tended to decrease, and as the replacement rate increased, the water permeability coefficient, absorption rate, carbon dioxide, and fine dust adsorption rate tended to increase. Therefore, it is judged that the permeable block using the basalt waste rock is superior to the existing permeable block.

An Analytical Study on the Structural Behavior of SC walls with Opening (개구부를 갖는 SC 벽체의 거동에 관한 해석적 연구)

  • Lee, Seung Joon;Choi, Byong Jeong;Kang, Shin Kyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.233-243
    • /
    • 2009
  • The objective of this study was to investigate the effect of openings on the structural behavior of SC walls. The FEM program ABAQUS was used in this analytical study. The main parameters were the locations and sizes of the openings: a total of 20 locations and a total of four opening sizes were adopted. The analysis results were compared with the results of the currently applied evaluation methods. The strength reduction factor method may be used to safely design SC walls with openings. The strength reduction factor of the effective strut method is more similar to that of the analysis results.

Reliability Analysis of Reduction Factor for Structural Design Guideline(draft) of Fiber Reinforced High Strength Concrete (섬유보강 고강도 콘크리트 구조설계지침(안)의 저감계수에 대한 신뢰도 분석)

  • Kim, Ah-Ryang;Choi, Jungwook;Paik, Inyeol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.100-108
    • /
    • 2021
  • The purpose of this study is to analyze the reliability index of a design by applying the reduction factor of the recently developed fiber reinforced high strength concrete design guideline(draft). By collecting material and member test data performed for the development of the design guideline(draft), statistical characteristics of material strength and member strength analysis equations are obtained. A simul ation that appl ies the material statistical characteristics and the member anal ysis equation of the design guidel ine(draft) is performed, and the statistical characteristics of the section strength are calculated by combining the statistical characteristics of the analysis equation. Reliability analysis was performed by applying the load combination of the domestic highway bridge design code and concrete structural code, and it was confirmed that the design that applies the reduction factor for materials and members suggested in the design guideline(draft) satisfies the target reliability index.

A Study on the Estimation for the Guaranteed Strength and Construction Quality of the Combined High Flowing Concrete in Slurry Wall (지하연속벽용 병용계 고유동 콘크리트의 시공 품질 및 보증강도 평가에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.811-817
    • /
    • 2006
  • The primary purpose of this study is to estimate the guaranteed strength and construction quality of the combined high flowing concrete which is used in the slurry wall of underground LNG storage tank. The required compressive strength of this type of concrete become generally known as a non economical value because it is applied the high addition factor for variation coefficients and low reduction factor under water concrete. Therefore, after estimation of the construction quality and guaranteed strength in actual site work, this study is to propose a suitable equation to calculate the required compressive strength in order to improve its difference. Application results in actual site work are shown as followings. The optimum nix design proportion is selected that has water-cement ratio 51%, sand-aggregate ratio 48.8%, and replacement ratio 42.6% of lime stone powder by cement weight. Test results of slump flow as construction quality give average 616~634mm. 500mm flowing time and air content are satisfied with specifications in the rage of 6.3 seconds and 4.0% respectively. Results of strength test by standard curing mold show that average compressive strength is 49.9MPa, standard deviation and variation coefficients are low as 1.66MPa and 3.36%. Also test results by cored cylinder show that average compressive strength is 66.4MPa, standard deviation and variation coefficients are low as 3.64MPa and 5.48%. The guaranteed strength ratio between standard curing mold and cored cylinder show 1.23 and 1.32 in the flanks. It is shown that applied addition factor for variation coefficients and reduction factor under water concrete to calculate the required compressive strength is proved very conservative. Therefore, based on these results, it is proposed new equation having variation coefficients 7%, addition factor 1.13 and reduction factor 0.98 under water connote.

A Infiltration Analysis in Unsaturated Porous Layer with Permeable Sidewalk Block (투수성 보도블록에서의 불포화 투수층 침투 해석)

  • Lee, Jae-Joon;Lee, Ye-Hee;Kwak, Chang-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.905-905
    • /
    • 2012
  • 현재 도시유역의 홍수피해를 경감시키기 위한 방안으로 우수유출 저감시설에 대한 연구가 활발히 진행 중에 있다. 그러나 침투형 우수유출 저감시설의 경우 침투량 산정에 필요한 여러 인자 중 토성에 의해 저감 능력에 많은 차이를 보이고 있으며, 강우시 침투로 인한 토양내 함수비의 변화와 선행강우 조건 등에 의해 정량적인 분석이 어려워 활용도가 미흡한 실정이다. 따라서 본 연구에서는 2009년 국립방재연구원에서 시행한 침투실험 자료의 조건과 동일하게 투수계수 및 형상이 다른 두 종류의 투수성 보도블록 A, B와 토양내 선행강우의 유무에 대하여 표 1과 같이 검증 케이스로 구분하고, 4 가지의 강우강도로 모의 조건을 설정한 후 불포화 투수층의 침투해석을 실시하고 실험결과를 이용하여 모의결과에 대한 검증을 시행하였으며, 모의 결과의 검증을 뒷받침하기 위하여 통계적인 적합도를 나타내는 평균제곱오차(RMSE), 평균편차비율(PBIAS), 모형 효율성 계수(NSE), 지속성 모형효율성 계수(PME)을 산정해 보았다. 검증 결과 그림 1과 같이 투수성 보도블록 B의 형태가 투수성 보도블록 A의 형태보다 적합도가 높게 나타났고, 50mm/hr의 강우강도에서 변동성이 크게 나타났으나, 50mm/hr를 제외한 나머지 강우조건에서 양호한 적합도를 보였으며, 선행강우가 있는 조건이 선행강우가 없는 조건에 비해 높은 적합도를 나타내었다.

  • PDF

Evaluation of the Properties of Absorbent-Pervious Cement Mortar (보투수성 시멘트 모르타르의 성능평가)

  • Lho, Byeong Cheol;Joo, Myung Ki;Choi, Jong Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.288-295
    • /
    • 2011
  • The objective of this study is to develop a proper absorbent-pervious pavement. By using single graded aggregates and SAP, permeability and water absorbability of absorbent-pervious pavement are improved, and also temperature reducing effect is found out. And several tests such as compressive and flexural strength tests, and permeability/water absorption tests of absorbent-pervious pavement are carried out to verify these kind of effects. The compressive and flexural strengths are increased according to decrease of single graded aggregate size, and increase of SAP content. And the volume of water retention and absorbability are increased according to the increase of SAP content and these are also increased in small size of single graded aggregate. And about $20^{\circ}C$ of difference is observed in surface temperature between normal asphalt pavement and absorbent-pervious pavement.

Evaluation of the Shear Strength of Reinforced Concrete Beams Strengthened with Continuous fiber Reinforced Polymer (연속섬유에 의하여 보강된 철근콘크리트 보의 전단강도 평가)

  • Lee Jung-Yoon;Hyang Hyun-Bok;Kim Ji-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.983-992
    • /
    • 2005
  • The shear failure modes of fiber reinforced polymer(FRP) strengthened concrete beams are quite different to those of the beams strengthened with steel stirrups. When the beams are strengthened with larger amount of FRP composites, the beams normally fail in shear due to concrete crushing before the FRP reaches its rupture strain. In order to predict the shear strength of such beams, the actual rupture strain must be known. The equations previously reported in the technical literature adopt an effective reduction factor for the rupture strain. These equations may not be applicable to FRP strengthened RC beams that are beyond the experimental application limits, because most of these equations are empirical in nature. This paper presents the results of an analytical study on the performance of reinforced concrete beams externally wrapped with FRP composites and internally reinforced with conventional steel stirrups.

A study on Green Roof System and Stormwater Reduction Effectiveness based on SWMM Model (SWMM 모델을 이용한 옥상녹화면에 따른 유출저감효과분석)

  • Kim, Jae Moon;Kim, Sae Bom;Kim, Byung Sung;Park, Kwang Hee;Shin, Hyun Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.383-383
    • /
    • 2018
  • 최근 기후변화와 도시화로 인해 국지성 집중호우 및 불투수면적이 증가하고 있는 실정이며, 도시 지역 내의 첨두유량, 도달시간, 지체시간 등과 같은 수문학적 인자가 변화함에 따라 재산피해, 인명피해가 발생하고 있다. 저영향개발(Low Impact Development, LID) 기법은 수리수문학적 및 환경생태학적 문제를 저감하는 방안 중 하나로써 도시지역에서 수환경을 자연상태로 복원하는 대안으로 제시되고 있다. LID 기법 중 하나인 옥상녹화는 도시 내의 불투수면 증가로 인한 초과 지표면유출을 저감시켜 물관리를 하는 기술이다. 본 연구는 경남 양산시 부산대학교 제 2 캠퍼스에 조성된 옥상녹화 장치를 이용하여 정량적으로 유출량을 분석하였다. 비식생구와 식생구를 설치하고 실험의 시나리오는 강우강도를 25, 50, 75, 100 mm/hr로 설정하여 측정된 데이터 값을 바탕으로 SWMM(Storm Water Management Model) 모델링을 수행하였다. 유출량 값은 SWMM 5의 매개변수 추정지원 시스템인 SWMM-SCE를 이용하여 모형을 자동보정하였다. 보정된 모의유량은 실측유량과 0.28~3.81% 만큼의 오차를 보였고 각 시나리오에 따라 검증한 결과 상관계수가 0.82 이상으로서 실측값과 높은 상관성을 나타내었다. 옥상녹화 실험의 경우, 강우강도 75mm/hr일 때 첨두유출저감율과 지연시간은 각각 15.45% 감소, 15초 지연으로 최적의 효율이 나타났으며 강우강도 25mm/hr일 때 첨두유출저감율과 지연시간은 각각 1.36% 감소, 4초 지연으로 최저의 효율이 나타났다. SWMM 모의 결과는 강우강도 75mm/hr일 때 첨두유출저감율과 지연시간은 각각 15.45% 감소, 16초 지연으로 최적의 효율이 나타났으며 강우강도 25mm/hr일 때 첨두유출저감율과 지연시간은 각각 2.73% 감소, 4초 지연으로 최저의 효율이 나타났다.

  • PDF

Material Characteristics of High-Strength Concrete Incorporating High Replacement Level of Blast-Furnace Slag (고로슬래그를 다량 함유한 고강도 콘크리트의 재료적 특성)

  • Lee, Hoi-Keun;Jung, Jae-Hong;Kim, Han-Joon;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.291-292
    • /
    • 2010
  • In this study, high-strength concrete mixtures were made with blast-furnace slag of 50% and 70% replacement level to evaluate material properties including compressive strength development, adiabatic temperature rise, autogenous shrinkage and chloride-ion migration coefficient. Test results showed that the use of high percentage blast-furnace slag in high-strength concrete can reduce heat of hydration and chloride-ion migration coefficient, result in control thermal cracking and improve durability performance especially under high corrosive environment.

  • PDF