• Title/Summary/Keyword: 감쇠시스템

Search Result 712, Processing Time 0.024 seconds

Damping System Design for Apartment Buildings Using Equivalent Frame Model (등가프레임모델을 이용한 공동주택의 감쇠시스템 설계)

  • Kim, Jong-Ho;Lee, Myoung-Kyu;Chun, Young-Soo;Lee, Dong-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.351-360
    • /
    • 2014
  • The purpose of this research is to introduce the simplified equivalent frame model for the equivalent lateral force procedure, the response spectrum procedure and nonlinear procedure according to ASCE7-10 in order to reduce the time of performance and reasonably evaluate the effect of applying the damping system with the various conditions for the analysis and the variable. In this research, the seismic performance assessment and the design of the damping system were conducted through the nonlinear time history analysis based on the performance based seismic design in ASCE7-10 in regard to applying the damping system to apartment buildings which is lately issued. The optimal design based on the 75% of seismic base shear was performed for an apartment building. The seismic performance assessment were conducted to check the safety of the building, and the economic evaluation was performed by comparing the amount of resource for the optimal designed building with the amount of resource for the original building. In addition, hysteresis dampers was applied to the apartment building, and the suggested equivalent frame model was performed using the damping system design in ASCE7-10, then its control effects were proved in the full scale model of the apartment building which was used in this research.

Comparative Study on Seismic Performance of Viscously Damped Self-Centering SDOF Systems with Elasto-Plastic SDOF Systems (점성 감쇠기를 가진 셀프 센터링 단자유도 시스템과 탄소성거동의 단자유도 시스템의 내진성능 비교에 관한 연구)

  • Kim, Hyung-Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.553-561
    • /
    • 2010
  • The purpose of this paper is to analytically find the approximate supplement damping ratio of the viscous damper installed in self-centering (SC) single-degree-of-freedom (SDOF) systems with maximum displacements that are similar to those of elasto-plastic (EP) SDOF systems. The behavior of an SC SDOF system under harmonic cyclic loading was first described. Then an analytical model that can capture the behavior of the viscously damped SC SDOF system was introduced. Analysis parameters that characterize the hysteresis of the EP and SC SDOF systems were chosen, and nonlinear time-history analyses were performed using 20 historical accelerograms. Most of the SC SDOF systems with viscous dampers with approximately 10-15% damping ratios presented mean maximum displacement values that were similar to those of the EP SDOF systems. To investigate in detail the seismic performance of both systems, three EP SDOF systems and six corresponding SC SDOF systems were selected. The analyses showed that all the SC SDOF systems eliminated the residual displacements after the end of their shaking, and that the SC SDOF systems with 15% damping ratios performed better than the EP SDOF systems in terms of maximum displacement and acceleration response.

Development of Variable Voltage Sensing for Identification of Dynamic Characteristics of TLCDs (동조액체기둥감쇠기의 동적특성을 파악하기 위한 가변전압측정 시스템 개발)

  • Jang, Seok-Jung;Kim, Jun-Hee;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.3
    • /
    • pp.275-281
    • /
    • 2015
  • In this study, vertical motion of a Tuned Liquid Column Damper(TLCD) is measured by a variable voltage measurement system in the electric field and design parameters of the TLCD are determined. First, nonlinear damping term of the TLCD is replaced as the equivalent viscous damping term. The natural frequency and damping ratio of dynamic characteristics of the TLCD are verified. In addition, a novel liquid level measurement system is developed for measuring vertical motion of the TLCD. For the experimental achievement, experimental characterizations of natural frequency and damping ratio of the TLCD are undertaken utilizing the developed variable voltage sensing. Also, shake table testing is performed to determine the dynamic characteristics of the TLCD. As a result, the feasibility of the proposed liquid level measurement system is verified by comparison with the capacitive type wavemeter.

Experimental Evaluation of Design Parameters for TLCD and LCVA (TLCD와 LCVA의 설계파라미터에 대한 실험적 평가)

  • Lee, Sung-Kyung;Min, Kyung-Won;Park, Ji-Hun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.5
    • /
    • pp.403-410
    • /
    • 2009
  • In this paper, damping coefficients and effective masses of tuned liquid-type column dampers were quantitatively evaluated based on experimental results by using system identification technique. First, shaking table tests were performed for two types of tuned liquid-type column dampers. Then, the dynamic characteristics of dampers used in this study were experimentally grasped from harmonic wave excitation testing results of the dampers with various water level. Finally, damping ratios and effective masses of the dampers with varying water level were quantitatively evaluated from minimizing the errors between numerical and experimental results. It was confirmed from system identification results that damping ratio and effective mass are decreased as the water level of dampers is increased.

Performance Evaluation of the New Smart Passive Control Device using Shaking Table Test (진동대 실험을 통한 신개념 스마트 수동제진장치의 제진성능 평가)

  • Jang, Dong-Doo;Jung, Hyung-Jo;Moon, Seok-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This paper presents the vibration control performance of the smart passive control system to suppress the undesired vibration of the structure subjected to the earthquake loadings. Smart passive control system is the MR damper-based control system augmented with electromagnetic induction(EMI) device which consists of permanent magnets and solenoid coils. According to the Faraday's law of electromagnetic induction, an EMI device produces electrical energy from the mechanical energy due to the reciprocal motions of the structure and provide it to the MR damper. The smart passive control system can be the simple and easy to implement and maintain control system by replacing the feedback control system including sensors, controllers and external power sources of the conventional MR damper-based semiactive control system with the EMI device. The control performance of the smart passive control system is evaluated through the set of shaking table test considering the various historical earthquake loadings.

Efficient Dynamic Analysis Using Complex Modal Superposition for Tall Buildings with Viscoelastic Dampers (복소모드중첩법을 이용한 점탄성감쇠기를 가진 고층건물의 효율적인 동적해석)

  • 김진구;홍성일;이경아;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.4
    • /
    • pp.671-679
    • /
    • 1999
  • 건물의 진동에너지 소산능력을 향상하기 위하여 점탄성감쇠를 설치하게 되면 이른바 비비례 감쇠시스템이 되어 구조물은 복소수형태의 고유모드와 고유치를 가진다. 복소모드중첩법은 이러한 복소모드를 이용하여 중첩함으로써 비비례 감쇠시스템 구조물의 정확한 동적 거동을 얻을 수 있는 방법이다. 그러나 건물이 고층화되면 많은 자유도로 인하여 고유치해석 및 모드중첩과정에서 많은 시간과 노력이 필요하게 된다. 본 논문에서는 효율적인 구조물의 모형화를 위하여 강막가정과 행렬응축기법을 적용하였다. 또한 몇 개의 주요 모드만을 선택하여 중첩하는 방법에 대하여 연구하였으며 구조물의 진동에 영향을 주는 모드의 선택을 위한 복소모드 응답참여계수를 제안하였다. 제안된 해석방법의 정확성과 효율성을 검토하기 위하여 예제 구조물을 대상으로 해석한 결과, 응답의 정확성을 유지하면서 해석에 필요한 시간을 대폭 절감할 수 있었다.

  • PDF

Equivalent Linear System Considering Earthquake Characteristics of MR damper installed in a SDOF (지진하중 특성을 고려한 단자유도 구조물에 설치된 MR감쇠장치의 등가선형시스템)

  • Moon, Byoung-Wooke-Ri;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.774-777
    • /
    • 2010
  • 본 논문에서는 MR 감쇠기의 비선형 특성을 등가의 선형감쇠로 치환하기 위한 방법으로 Newmark와 Hall이 제안한 감쇠계수를 이용하였다. 응답스펙트럼의 감쇠율을 나타내는 감쇠기계수는 구조물의 최대변위를 이용하여 등가감쇠비를 추출할 수 있다는 장점을 가지고 있다. 하지만 이러한 응답스펙트럼은 구조물에 작용하는 지진하중의 특성에 따라 경향이 달라진다. 본 논문에서는 기존의 등가감쇠비 산정식을 수정하여 제안하고, 지진하중 특성에 따른 등가감쇠비의 변화를 살펴보았다. MR 감쇠기의 등가감쇠비는 가진하중과 최대마찰력의 비율에 따라 결정되며, 장주기 구조물의 경우 등가감쇠비가 감소한다. MR 감쇠기의 점성은 마찰감쇠와의 상호작용에 의해 단순한 산술합 이상의 감쇠비 증가 효과를 가진다.

  • PDF

Optimal design of nonlinear damping system for seismically-excited adjacent structures using multi-objective genetic algorithm integrated with stochastic linearization method (추계학적 선형화 방법 및 다목적 유전자 알고리즘을 이용한 지진하중을 받는 인접 구조물에 대한 비선형 감쇠시스템의 최적 설계)

  • Ok, Seung-Yong;Song, Jun-Ho;Koh, Hyun-Moo;Park, Kwan-Soon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.6
    • /
    • pp.1-14
    • /
    • 2007
  • Optimal design method of nonlinear damping system for seismic response control of adjacent structures is studied in this paper. The objective functions of the optimal design are defined by structural response and total amount of the dampers. In order to obtain a solution minimizing two mutually conflicting objective functions simultaneously, multi-objective optimization technique based on genetic algorithm is adopted. In addition, stochastic linearization method is embedded into the multi-objective framework to efficiently estimate the seismic responses of the adjacent structures interconnected by nonlinear hysteretic dampers without performing nonlinear time-history analyses. As a numerical example to demonstrate the effectiveness of the proposed technique, 20-story and 10-story buildings are considered and MR dampers of which hysteretic behaviors vary with the magnitude of the input voltage are considered as nonlinear hysteretic damper interconnecting two adjacent buildings. The proposed approach can provide the optimal number and capacities of the MR dampers, which turned out to be more economical than the uniform distribution system while maintaining similar control performance. The proposed damper system is verified to show more stable performance in terms of the pounding probability between two adjacent buildings. The applicability of the proposed method to the design problem for optimally placing semi-active control system is examined as well.

Vibration Control of Asymmetric Buildings Using Viscoelastic Dampers (점탄성 감쇠기를 이용한 비대칭 건물의 진동제어)

  • 김진구;방성혁;이진수
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 2001
  • 본 연구에서는 진동제어를 목적으로 강성이 비대칭적으로 분포된 구조물에 점탄성 감쇠기를 설치할 경우 비틀림 응답을 줄이기 위한 감쇠기의 효과적인 배치방법에 관하여 연구하였다. 비대칭 구조물의 응답에 미치는 점탄성 감쇠기의 효과를 알아보기 위하여 비대칭 비비례감쇠시스템의 특성방정식을 유도하고, 고유치해석을 통해 감쇠기가 설치된 비틀림 건물의 거동특성을 파악하였다. 이를 바탕으로 강성 편심 및 진동수비에 따른 최적 감쇠 편심을 찾아 이를 3차원 그래프로 나타내었다. 이를 이용하여 비대칭건물에 감쇠기를 설치했을 때 같은 양의 감쇠기를 대칭으로 설치하였을 때 보다 그 효과가 더욱 향상되는 것으로 나타났다. 또한 비대칭 건물의 비틀림제어면에서 점탄성 감쇠기가 점점 감쇠기보다 우수한 것으로 나타났다.

  • PDF

Validity of Linear Combination Approach based on Net Damping Analysis of Cable-Damper System (케이블-댐퍼 시스템의 전체감쇠비 해석을 통한 선형조합 접근법의 유효성)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.467-475
    • /
    • 2009
  • Existing studies have suggested Universal Curve only for supplemental damping by damper. Therefore net damping has been determined by means of arithmetic summation between intrinsic, aero-damping of cable and supplemental damping of damper. However linear combination approach by means of the arithmetic summation is not enough theoretical background. So validity of this approach should be verified in order to design adequate cable-damper system by engineers. This study establishes governing differential equation which can consider intrinsic, aero-damping and supplemental damping as well. And also analysis method is solved by combination of muller method and successive iteration method. Consequently, this study succeeds in verification for validity of linear combination approach. As a result of this study, linear combination approach is limitedly effective in case of low stiffness and optimum damping coefficient of damper, short distance from support to damper, lower vibration mode, low aero-damping, and normal windy environment. Whereas this study will be effective in case of opposite conditions, and existing studies or linear combination approach occur to further error. Meaning of this study presents exact solution for net damping of cable-damper system, and verifies linear combination approach by means of the analysis method. In the future, if monitoring of optimum damping coefficient of a damper against aero-damping is feasible on time, algorithm of this study will be available for control of cable and semi-active damper system such as magneto-rheological damper.