• Title/Summary/Keyword: 감쇠기

Search Result 978, Processing Time 0.027 seconds

Optimal Design of Viscoelastic Dampers and Support Braces (점탄성 감쇠기와 설치용 가새의 최적설계)

  • 박지훈;이상현;강경수;황재승;김진구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.45-55
    • /
    • 2001
  • The purpose of this paper is to present the optimal design method of viscoelastic dampers and support brace stiffnesses. The dynamics of visco-elastic dampers and support braces connected in series is modeled by state equation. A constraint on maximum story drifts which are computed using RMS\`s of story drifts and peak factors is added to the optimization problem. The number of variables is reduced by including the constraint associated with the dynamic behavior of the structure in the procedure to compute the gradient of the inequality equation about constraint on the maximum story drifts. In the design example, it is confirmed that the design of dampers considering support brace stiffnesses is necessary when sufficient brace stiffnesses cannot be supplied. It is also found that unnecessary brace stiffnesses can be removed by adding brace stiffnesses to optimal design variables and that the increase of damper volumes to compensate for the variation of maximum story drifts is pretty small.

  • PDF

Acoustic-Damping Characteristics of Half-Wave Resonator in a Combustion Chamber of Liquid Rocket Engine (로켓엔진 연소기에서 반파장 공명기의 음향감쇠에 관한 수치적 연구)

  • Sohn Chae-Hoon;Park I-Sun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.4
    • /
    • pp.9-15
    • /
    • 2005
  • A linear acoustic analysis is performed to explore the characteristics of acoustic damping by a gas-liquid scheme coaxial injector in a liquid rocket engine. The injector can play a role of acoustic resonator. Acoustic-damping characteristics of half-wave resonator are compared with those of quarter-wave resonator. Various effects of the boundary absorption coefficient, injector length and sound speed in combustion chamber and resonator are investigated. As a result, short tuning length of resonator and low sound speed of the medium have a favorable effect on acoustic damping. As the boundary absorption coefficient decreases, the tuning range of the resonator length becomes narrower.

Fabrication and characterization of in-line fiber-optic tunnable attunuator (인라인 가변 광섬유 감쇠기 제작 및 특성 측정)

  • 김효겸;윤대성;문정원;김광택
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.22-23
    • /
    • 2003
  • 광섬유 가변 감쇠기는 광증폭기, add/drop 모듈, Mux/Demux, 광송수신기 등 중요한 광통신 시스템의 입력 및 출력 광신호 레벨을 적절하게 제어하기 위해 요구되는 중요한 소자이다. 가변 감쇠기는 높은 신뢰성, 높은 해상도, 작은 삽입손실, 낮은 편광 및 파장 의존성 손실 등이 요구되어 진다. 가변 광감쇠기는 평면 기판에 형성된 도파로 의 열광학 효과나 전기광학 효과를 이용하는 기법과 MEMS 기술에 기초한 방법이 잘 알려져 있다. (중략)

  • PDF

Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System (스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선)

  • Jung, Hyung-Jo;Jung, Chan-Kuk;Choi, Kang-Min;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.37-46
    • /
    • 2006
  • In this study, the efficacy of the newly developed smart passive control system to improve seismic performance of base isolated building structures is numerically verified. The smart passive control system consists of a magnetorheological (MR) damper and an electromagnetic induction (EMI) part. The damping characteristics of an MR damper can be controlled by the current generated in an EMI part according to the Faraday's law of electromagnetic induction. An EMI part consisting of a permanent magnet and a solenoid coil could substitute a control system including sensors, a controller and an external power supply in a conventional smart control system. The benchmark control problem for a base isolated building presented by the american society of civil engineers is considered for numerical simulation. The control performance of the smart passive control system is compared to that of the conventional smart control system using MR dampers. It is demonstrated from the numerical simulation results that the smart passive control system is useful to improve the seismic performance of base isolated buildings.

Excitation and System Identification of a Full-Scale Five-Story Structure for the Application of Viscoelastic Dampers (점탄성 감쇠기 적용을 위한 실물크기 5층 건물의 가진 및 시스템 식별)

  • 민경원;이상현;김진구;이영철;이승준;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.1-7
    • /
    • 2003
  • Excitation and system identification are carried out for a full-scale five-story structure to obtain fundamental data which will be used for the design of viscoelastic dampers, The hybrid mass driver(HMD) installed on the fifth floor was employed as external exciter to provide excitation for the building, Each floor response was measured and processed to find out where and how the viscoelastic dampers are located and designed. The sine-sweep and white noise loadings were applied to the structure by the HMD to obtain dynamic characteristics such as natural frequencies, damping ratios, and modes, The identified building was experimentally investigated again with the designed viscoelastic dampers installed at inter-stories to obtain the response behavior in the companion paper.

Seismic Fragility Functions of a SDOF Nonlinear System with an Energy Dissipation Device (에너지 소산형 감쇠기가 설치된 단자유도 비선형 시스템의 지진취약도 함수)

  • Park, Ji-Hun;Yun, Soo-Yong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.1-13
    • /
    • 2012
  • Seismic fragility functions are derived for probabilistic evaluation of seismic control performance of energy dissipation devices installed in reinforced concrete structures. Displacement-dependent dampers are added to the nonlinear single-degree-of-freedom systems with different natural periods and hysteretic characteristics of which stiffness and strength has uncertainty. Nonlinear time history analysis is conducted for those SDOF systems and the result is processed statistically to obtain seismic fragility functions in the form of log normal distribution. Variation of seismic fragility functions for different parameters of SDOF systems and dampers are investigated and the seismic control performance is assessed probabilistically.

Design of Friction Dampers installed at a Multi-Story Building under Seismic Load (지진하중을 받는 다층 건물에 설치된 마찰감쇠기 설계)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.457-462
    • /
    • 2011
  • In this study, a simplified design procedure for friction dampers of a multi-story structure in order to reduce seismic response is proposed. To get insight for control effect of the structure with friction dampers is difficult, because of a nonlinear characteristic by a friction damper. Since a control force of a friction damper is influenced by coupling velocity between floors, adjoining modes are coupled. Thus structural response are derived by assuming steady-state response in resonance. As it is impossible that an exact solution is obtained for seismic load, first, a closed form solution can be achieved under harmonic vibration. Second, to convert a three-story building into a single-degree-of-freedom(SDOF) structure, modal analysis is performed. Third, an equivalent damping ratio is derived with utilizing closed form solution. And response reducing factor is proposed by it. Finally, friction force of a damper is designed for using response reducing factor, and then designed dampers are verified for seven seismic data. The nonlinear analysis results confirm the validity of the proposed procedure.

Progressive Collapse Resisting Capacity of Moment Frames with Viscous Dampers (점성감쇠기가 설치된 모멘트골조의 연쇄붕괴 저항성능)

  • Kim, Jin-Koo;Lee, Seung-Jun;Choi, Hyun-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.517-524
    • /
    • 2010
  • In this paper the progressive collapse resisting capacity of steel moment frames with viscous dampers was evaluated by nonlinear dynamic analysis. The effects of dampers installed in steel beam-column sub-assemblages with varying natural period and yield strength were evaluated after sudden removal of a column. According to the parametric study the vertical displacement general decreased as the damping ratio of the system increased, and the dampers were effective both in elastic and elasto-plastic systems. The nonlinear dynamic analysis results of the 15-story analysis models showed that the decrease in vertical deflection of the structure with 9m span length, which showed larger deflection, was more predominant than that of the structure with 6m span length.

Design of Unbend Braces to Satisfy Given Performance Acceptance Criteria (성능수준 만족을 위한 가새헝 소성 감쇠기의 설계)

  • 김진구;김유경;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.6
    • /
    • pp.47-54
    • /
    • 2001
  • Unbond brace hysteretic dampers are generally used to prevent or decrease structural damage in building structures subjected to strong earthquake by its energy dissipating hysteretic behavior. In the study, a straightforward design procedure for unbond brace hysteretic dampers was developed. The required amount of equivalent damping to satisfy given performance acceptance criteria was obtained conveniently based on the capacity spectrum method without carrying out time-consuming nonlinear dynamic time history analysis. Then the size of the unbond braces is determined from the required equivalent damping. Parametric study has been performed for the design variables such as natural period, yield strength, the stiffness after the first yield stress of the unbond brace. The procedure was applied to 5-story and 10-story steel frames for verification of the proposed method. According to the earthquake time history analysis results, the maximum displacement of the model structure with unbond braces supplied in accordance with the proposed method corresponds well with the given target displacement.

  • PDF

PROBABILISTIC SEISMIC PERFORMANCE EVALUATION OF TUNED LIQUID COLUMN DAMPERS (확률적(確率的) 방법(方法)에 의한 TLCD 감쇠기(減衰器)의 지진(地震)에 대한 성능(性能) 평가(評價))

  • Han, Bong Koo
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.4 s.29
    • /
    • pp.115-120
    • /
    • 1996
  • 유연구조물(柔軟構造物)의 수동제어(受動制御) 시스템인 TLCD 감쇠기(減衰器)의 지진(地震)에 대한 성능(性能) 평가(評價)를 확률적(確率的) 랜덤 진동(振動) 해석방법(解析方法)을 이용하여 연구하였다. 대표적(代表的) 지진운동(地震運動)은 확률적(確率的) 비정상(非正常) 추계과정방법(推計過程方法)을 이용(利用)하였으며, TLCD 감쇠기(減衰器)의 비선형(非線型) 감쇠력(減衰力)에 대한 계산(計算)은 등가선형기법(等價線形技法)을 이용(利用)하였다. 매개변수(媒介變數)에 대한 연구(硏究)를 통하여 TLCD 감쇠기(減衰器)의 성능(性能) 평가(評價)를 수행(遂行)하였다.

  • PDF