• Title/Summary/Keyword: 감마지표

Search Result 86, Processing Time 0.028 seconds

Expression profile of defense-related genes in response to gamma radiation stress (방사선 스트레스 반응 방어 유전자의 탐색 및 발현 분석)

  • Park, Nuri;Ha, Hye-Jeong;Subburaj, Saminathan;Choi, Seo-Hee;Jeon, Yongsam;Jin, Yong-Tae;Tu, Luhua;Kumari, Shipra;Lee, Geung-Joo
    • Journal of Plant Biotechnology
    • /
    • v.43 no.3
    • /
    • pp.359-366
    • /
    • 2016
  • Tradescantia is a perennial plant in the family of Commelinaceae. It is known to be sensitive to radiation. In this study, Tradescantia BNL 4430 was irradiated with gamma radiation at doses of 50 to 1,000 mGy in a phytotron equipped with a $^{60}Co$ radiation source at Korea Atomic Energy Research Institute, Korea. At 13 days after irradiation, we extracted RNA from irradiated floral tissues for RNA-seq. Transcriptome assembly produced a total of 77, 326 unique transcripts. In plantlets exposed to 50, 250, 500, and 1000 mGy, the numbers of up-regulated genes with more than 2-fold of expression compared that in the control were 116, 222, 246, and 308, respectively. Most of the up-regulated genes induced by 50 mGy were heat shock proteins (HSPs) such as HSP 70, indicating that protein misfolding, aggregation, and translocation might have occurred during radiation stress. Similarly, highly up-regulated transcripts of the IQ-domain 6 were induced by 250 mGy, KAR-UP oxidoreductase 1 was induced by 500 mGy, and zinc transporter 1 precursor was induced by 1000 mGy. Reverse transcriptase (RT) PCR and quantitative real time PCR (qRT-PCR) further validated the increased mRNA expression levels of selected genes, consistent with DEG analysis results. However, 2.3 to 97- fold higher expression activities were induced by different doses of radiation based on qRT-PCR results. Results on the transcriptome of Tradescantia in response to radiation might provide unique identifiers to develop in situ monitoring kit for measuring radiation exposure around radiation facilities.

Differences in Thrombolytic Effects in Accordance with Dosing-regimens of Tissue-type Plasminogen Activator in Experimental Pulmonary Embolism (실험적 폐색전증에서 조직형플라스미노겐활성체의 투여방법에 따른 혈전용해효과의 차이)

  • Chung, Hee-Soon;Kim, Ho-Jung;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.123-134
    • /
    • 1993
  • Background: Tissue-type plasminogen activator is a physiologic activator, which has high affinity for fibrin and is activated by fibrin. Because of these properties, t-PA has the potential to induce effective thrombolysis without producing a systemic lytic state. In practice, however, therapeutically efficacious doses of t-PA has been associated with the development of a systemic lytic state. As experience with t-PA has accumulated, it has suggested that the fibrin selectivity is influenced by the dose and duration of t-PA infusion, and many studies have performed in an attempt to optimize the duration of t-PA regimen. Methods: This study was designed to assess the thrombolytic efficacy of t-PA and the differences of two dosing regimens of t-PA (infusion of 1 mg/kg t-PA over 15 or 180 minutes) in a canine model of pulmonary embolism, induced by injection of radioactive autologous blood clots. By continuously counting over both lung fields with a external gamma counter, we correlated rate and extent of pulmonary thrombolysis with corresponding pulmonary hemodynamics in addition to the gas analyses of arterial and mixed venous blood. Results: 1) While total clot lysis was similar ($36.2{\pm}3.3%$ and $39.6{\pm}2.3%$ respectively, p>0.05) when t-PA was infused over 15 or 180 minutes, the rate of lysis during infusion was markedly increased with the shorter infusion ($81.4{\pm}16.8%/hr$ vs $37.3{\pm}2.4%/hr$, p<0.05). 2) The duration of thrombolysis was $63.3{\pm}22.2$ minutes although t-PA was administered over 15 minutes, and it was only $148.5{\pm}14.0$ minutes in case of the infusion over 180 minutes (p<0.05). 3) The increased rate of thrombolysis with the shorter infusion was accompanied by a faster amelioration of cardiopulmonary impairment from pulmonary embolism (p<0.05). Conclusion: It is concluded that the shorter (15 minutes) infusion of t-PA is superior to the longer (180 minutes) infusion when the dose is equal, in consideration of the faster improvement in cardiopulmonary impairment from pulmonary embolism.

  • PDF

Evaluation of the Jaw-Tracking Technique for Volume-Modulated Radiation Therapy in Brain Cancer and Head and Neck Cancer (뇌암 및 두경부암 체적변조방사선치료시 Jaw-Tracking 기법의 선량학적 유용성 평가)

  • Kim, Hee Sung;Moon, Jae Hee;Kim, Koon Joo;Seo, Jung Min;Lee, Joung Jin;Choi, Jae Hoon;Kim, Sung Ki;Jang, In-Gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.177-183
    • /
    • 2018
  • Purpose : Volumetric Modulated Arc Therapy(VMAT) has the advantage of uniformly and precisely irradiating the tumor to the shape of the tumor while reducing the risk of radiation damage to normal tissues. such as brain cancer, head and neck cancer and prostate cancer, It is being used for treatment. The purpose of this study is to evaluate the usefulness of the Jaw-Tracking technique(JTT) in VMAT for brain and head and neck cancer. Materials and Methods : We selected eight patients with brain and head and neck cancer(4 Brain, 4 head and neck) who were treated with the VMAT treatment technique. Contouring information of the patient's tumor and normal organ was fused to the Rando phantom using the deformable registration of Velocity(Varian, USA). A treatment plan was developed using the Varian Eclipse(ver 15.5, Varian, USA) with the same patient actual beam parameters except for the use of jaw-tracking. As the evaluation index, the maximum dose and mean dose of target and OAR were compared and a portal dosimetry was performed for the treatment plan verification. Results : When using JTT, the relative dose of OAR decreased by 5.24 % and the maximum dose by 7.05 %, respectively, compared with the Static-Jaw technique(SJT). In the various OARs, the mean dose and maximum dose reduction ranges ranged from 0.01 to 3.16 Gy and from 0.12 to 6.27 Gy, respectively. In the case of the target, the maximum dose of GTV, CTV, PTV decreased by 0.17 %, 0.43 %, and 0.37 % in JTT, and the mean dose decreased by 0.24 %, 0.47 % and 0.47 %, respectively. Gamma analysis The JTT and SJT passing rates were $98{\pm}1.73%$ and $97{\pm}1.83%$ on the basis of 3 % / 3 mm, respectively. Comparing the doses of all OARs applied to the experiment, it was found that the use of JTT resulted in a significant decrease in dose due to additional jaw shielding besides MLC than SJT. Conclusion : In radiation therapy using VMAT treatment plan, we can apply JTT in the case of adjacent tumor and normal organs such as brain cancer and head and neck cancer, and in radiotherapy required large field and high energy caused increase leakage dose through MLC. It is considered that the target dose of PTV can be increased by lowering the dose of normal tissue surrounding the tumor.

  • PDF

A Comparative Study of Subset Construction Methods in OSEM Algorithms using Simulated Projection Data of Compton Camera (모사된 컴프턴 카메라 투사데이터의 재구성을 위한 OSEM 알고리즘의 부분집합 구성법 비교 연구)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Mi-No;Lee, Ju-Hahn;Kim, Joong-Hyun;Kim, Chan-Hyeong;Lee, Chun-Sik;Lee, Dong-Soo;Lee, Soo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.234-240
    • /
    • 2007
  • Purpose: In this study we propose a block-iterative method for reconstructing Compton scattered data. This study shows that the well-known expectation maximization (EM) approach along with its accelerated version based on the ordered subsets principle can be applied to the problem of image reconstruction for Compton camera. This study also compares several methods of constructing subsets for optimal performance of our algorithms. Materials and Methods: Three reconstruction algorithms were implemented; simple backprojection (SBP), EM, and ordered subset EM (OSEM). For OSEM, the projection data were grouped into subsets in a predefined order. Three different schemes for choosing nonoverlapping subsets were considered; scatter angle-based subsets, detector position-based subsets, and both scatter angle- and detector position-based subsets. EM and OSEM with 16 subsets were performed with 64 and 4 iterations, respectively. The performance of each algorithm was evaluated in terms of computation time and normalized mean-squared error. Results: Both EM and OSEM clearly outperformed SBP in all aspects of accuracy. The OSEM with 16 subsets and 4 iterations, which is equivalent to the standard EM with 64 iterations, was approximately 14 times faster in computation time than the standard EM. In OSEM, all of the three schemes for choosing subsets yielded similar results in computation time as well as normalized mean-squared error. Conclusion: Our results show that the OSEM algorithm, which have proven useful in emission tomography, can also be applied to the problem of image reconstruction for Compton camera. With properly chosen subset construction methods and moderate numbers of subsets, our OSEM algorithm significantly improves the computational efficiency while keeping the original quality of the standard EM reconstruction. The OSEM algorithm with scatter angle- and detector position-based subsets is most available.

Different Uptake of Tc-99m ECD and Tc-99m HMPAO in the Normal Brains: Analysis by Statistical Parametric Mapping (정상 뇌 혈류 영상에서 방사성의약품에 따라 혈류 분포에 차이가 있는가: 통계적 파라미터 지도를 사용한 분석)

  • Kim, Euy-Neyng;Jung, Yong-An;Sohn, Hyung-Sun;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.244-254
    • /
    • 2002
  • Purpose: This study investigated the differences between technetium-99m ethyl cysteinate dimer (Tc-99m ECD) and technetium-99m hexamethylpropylene amine oxime (Tc-99m HMPAO) uptake in the normal brain by means of statistical parametric mapping (SPM) analysis. Materials and Methods: We retrospectively analyzed age and sex matched 53 cases of normal brain SPECT. Thirty-two cases were obtained with Tc-99m ECD and 21 cases with Tc-99m HMPAO. There were no abnormal findings on brain MRIs. All of the SPECT images were spatially transformed to standard space, smoothed and globally normalized. The differences between the Tc-99m ECD and Tc-99m HMPAO SPECT images were statistically analyzed using statistical parametric mapping (SPM'99) software. The differences bgetween the two groups were considered significant ant a threshold of corrected P values less than 0.05. Results: SPM analysis revealed significantly different uptakes of Tc-99m ECD and Tc-99m HMPAO in the normal brains. On the Tc-99m ECD SPECT images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the basal ganglia and thalamus, and in the superior region of the cerebellum. On the Tc-99m HMPAO SPECT images, relatively higher uptakes was observed in subcortical areas of the frontal region, temporal lobe, and posterior portion of inferior cerebellum. Conclusion: Uptake of Tc-99m ECD and Tc-99m HMPO in the normallooking brain was significantly different on SPM analysis. The selective use of Tc-99m ECD of Tc-99m HMPAO in brain SPECT imaging appears especially valuable for the interpretation of cerebral perfusion. Further investigation is necessary to determine which tracer is more accurate for diagnosing different clinical conditions.

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.