• Title/Summary/Keyword: 감마선조사장치

Search Result 6, Processing Time 0.018 seconds

Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device (유리선량계를 이용한 Biobeam8000 감마선 조사장치의 선량평가)

  • Shin, Sang-Hun;Lee, Sung-Hyun;Son, Ki-Hong;Lee, Hyun-Ho;Kim, Kum-Bae;Jung, Hai-Jo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.198-205
    • /
    • 2011
  • Gamma irradiator is widely used for cell, animal experiment, irradiation for blood, dose measurement, and education. Biobeam8000 gamma irradiator (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs137, 81.4 TBq) that KIRAMS (Korea Institute of Radiological and Medical Science) has is a irradiation device that enables to be used in large-capacity of 7.5 L and extensive area. Cs-137 source moves range of 24 cm back-and-forth in a regular cycle in beaker for uniform irradiation and a beaker that puts a specimen like existing radiation irradiator such as Gammacell3000 rotates $360^{\circ}$ during irradiation. Precise dose information according to the location of radiation source would be needed because of the movement of radiation source, whereas radiation could be uniformly irradiated in comparison with existing gamma irradiator. In this study, dose distribution of the inside beaker located in Biomeam8000 gamma irradiator was measured using glass dosimeter, and dose evaluation and distribution regarding dose linearity and dose reproducibility were implemented based on measurement results. This aims to show guideline for efficient use of irradiator based on measurement result when doing experiment or radiation exposure.

A Study on the Performance Evaluation of Standard Gamma Irradiation System Using Monte Carlo Code (몬테카를로 코드를 활용한 표준 감마선 조사장치의 성능평가에 관한 연구)

  • Park, Won-Seok;Heo, Seung-Uk;Kim, Jang-Oh;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.179-184
    • /
    • 2018
  • In this study, we compared the measured values of the effective beam size of standard gamma irradiator with the simulation results to provide a useful means to the effective beam area determination. Results of the simulation and measured using ion chamber was distributed in a relative error of 4.5 ~ 7.3% of the case of air kerma rate. The size of the effective beam area is when the simulation was implemented in the horizontal direction 27cm, 21.6cm vertical direction, the measured result using a film was obtained similar results with the horizontal direction 26.5cm, 21.9cm vertical direction. The relative error in the horizontal direction is 1.85% and 1.38% vertical effective beam area was also similarly distributed around the field gamma rays. As a result of the study, it was confirmed that the effectiveness of the simulation was sufficient for the gamma irradiation system. In particular, it is small relative errors in the effective beam size than the air kerma rate is considered to be due to the size of the beam is determined by geometric factors rather than the capacity of the standard source. A further study is needed to improve the reliability of the photon energy distribution diagram using simulation.