• Title/Summary/Keyword: 감마방사선

Search Result 992, Processing Time 0.028 seconds

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

Treatment Outcome of Gamma Knife Radiosurgery for GH-Secreting Pituitary Tumors (성장호르몬 분비 뇌하수체선종에 대한 감마나이프 방사선수술의 치료결과)

  • Lim, Young Jin;Choi, Yeong Ho;Leem, Won;Lee, Ki Taek;Koh, Jun Seok;Kim, Tae Sung;Kim, Gook Ki;Rhee, Bong Arm
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.5
    • /
    • pp.567-574
    • /
    • 2001
  • Objective : As for growth hormone(GH) secreting pituitary adenoma, it's remission should be declared on the basis of satisfactory controlling of the tumor, normalization of hormonal level, and symptomatic improvement of the patient. Several modalities of treatment have been applied and administered, and yet, this disease still remains as inveterate one to be fully treated. The purpose of this study is to evaluate the outcome of gamma knife radiosurgery(GKRS) for GH secreting pituitary adenoma, and to identify various factors affecting the outcome of the treatment. Method : A group of 24 out of 35 patients, treated by Leksell gamma knife unit during the period of March of 1992 through October of 1997, had been observed for more than two years. The mean target volume of microadenoma was $449.3mm^3(range 216-880mm^3)$, and that of macroadenoma was $3183.1mm^3(range 1456-13125mm^3)$. The tumor margin was covered with 50% isodose profile, and mean marginal dose was 25.2Gy(range 15-32.4Gy). The mean number of isocenter was 4.3(range 1-6). The exposed dose to the optic apparatus was less than 8Gy. The mean follow-up period was 37.8months(range 24-102months). Result : No patients showed any increase in the tumor volume during the follow-up period. And definite shrinkage of tumor volume(tumor volume reduction rate, TVRR : more than 50%) was obtained in 10 patients(41.7%). Twenty one patients(87.5%) had reduced hormonal level compared than pre-treatment level. Among them, normalization of the hormonal level was achieved in 12 patients(50%). Clinicoendocrinological remission was seen in 3 patients (12.5%). According to the results of statistical analysis, tumor volume(p=0.016),duration of symptoms(p=0.046), initial GH level(p=0.017), and the invasion of cavernous sinus(p=0.036) were significantly favorable to post-radiosurgical outcome. The TVRR was significantly related to post-radiosurgical reduction of serum GH level. Permanent complication was not seen. Conclusion : The authors concluded that GKRS is a safe and effective treatment modality for acromegaly. To otain the better outcome of GKRS in GH secreting pituitary adenoma, more careful and sophisticated treatment-planning is recommended.

  • PDF

The Role of Gamma Knife Radiosurgery for Essential and Secondary Trigeminal Neuralgia - vs Microsurgery - (특발성 및 이차성 삼차 신경통에 대한 감마나이프 방사선수술의 역할 - 수술적 치료와의 비교 -)

  • Keem, Sang Hyun;Lim, Young Jin;Leem, Won;Rhee, Bong Arm;Koh, Jun Seok;Kim, Tae Sung;Kim, Gook Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.5
    • /
    • pp.650-658
    • /
    • 2000
  • Objective : To evaluate the role of Gamma Knife radiosurgery in essential and tumor-related(secondary) trigeminal neuralgia, outcomes of radiosurgery and microsurgery were compared each other. Methods : Five patients with essential trigeminal neuralgia underwent stereotactic radiosurgical treatment with Leksell Gamma Knife and twenty five patients were treated with microsurgery during the same period(1994. 1-1997. 6). A 4-mm collimator was used and REZ or proximal portion of trigeminal nerve was targeted with maximal dose of 60-72Gy. The mean follow-up after radiosurgery was 39.4 months and that after microsurgery was 47.9 months. Results : At the last follow-up, four patients(80%) had excellent(pain free) or good(50-90% pain relief) outcomes, one(20%) had poor control after radiosurgical treatment. Twenty-three patients(92%) had excellent or good outcomes and two(8%) had poor results after microsurgery. Postoperative complications occurred in ten(40%) with microsurgery, but there were no complications in patients with Gamma Knife radiosurgery. Six patients with secondary trigeminal neuralgia received radiosurgical treatment directed at their tumors, and three patients were surgically treated. Three of six(50%) patients treated with Gamma Knife had pain relief while two of three patients with surgical treatment showed immediate pain relief. Post-treatment complications were developed in two of six radiosurgical patients and in one of three surgical patients. Conclusion : Gamma Knife stereotactic radiosurgery may be considered as a useful and alternative option for the treatment of essential and secondary trigeminal neuralgia owing to of its safety and less complications. The preliminary results obtained in our series appear encouraging, although the outcome is not so good as that of surgery.

  • PDF

Evaluation of Radiation effective dose by Naturally Radionuclides in the Soil of Busan (부산지역 토양 내 천연방사성핵종 분석 및 유효선량율 평가)

  • Kim, Jung-Hoon;Kim, Chang-Soo;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3658-3666
    • /
    • 2014
  • The presence of $^{238}U$, $^{232}Th$ and $^{40}K$, which are naturally residing radionuclides, in the ordinary soil of Busan, the 2nd largest city in Korea, was anlayzed and the residents' radiation exposure to ordinary soil was evaluated. Regarding the measurement methods, to conduct a detailed analysis of the naturally residing radionuclides in the soil of Busan, this study divided the 16 administrative districts into a lattice structure with 3 spots, and collected a total of 48 soil samples (July 2012 and April 2013). ICP-MS was used to analyze the concentration of the radioactivity of $^{238}U$ and $^{232}Th$ in the soil, and a HpGe detector, a gamma ray detector, was used to analyze the radioactivity of $^{40}K$. The measurement values of this study were compared with the concentration of radioactivity of East Asian regions. The concentration of $^{238}U$ nuclides in Korea was lower than the mean, whereas the concentration of $^{232}Th$ and $^{40}K$ nuclides was higher than the mean. The higher mean concentrations of $^{232}Th$ and $^{40}K$ than the mean were attributed to the many granite areas that contain a great deal of naturally occurring radionuclides.

Analysis of Gamma-ray Spectrum and Assessment of Corresponding Exposure Rate by Means of Response Matrix Method (Response Matrix에 의한 감마선(線) Spectrum 및 그 조사선량(照射線量) 해석(解析))

  • Kim, Seong-Kwan;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.3-14
    • /
    • 1986
  • A stud has been carried out for figuring out real photon spectrum from an observed gamma-ray spectrum by means of response matrix method, which is known one of the relatively convenient method for the estimation of exposure rate of a complex gamma ray field in comparison with graphical analysis and least square fitting of the measured spectrum. A 3'${\times}$3' cylindrical Nal(T1) scintillation detector in association with multichannel pulse height analyzer and six reference gamma ray sources covering the photon energy range of 0.05 to 2.0 MeV were used. In dividing the energy region for the construction of response matrix, two different approaches were attempted. One is dividing the entire energy region of interest into 20 bins, one of which corresponds to a width of 0.1 MeV to form $20{\times}20$ matrix, and another is dividing the 2 MeV region into 14 bins to form $14{\times}14$ matrix consists of $0.1(MeV)^{1/2}$ intervals assuming the resolution of the detector is dependent on square root of the incident photon energy. Inversion of thus constructed matrices was performed by a computor(P-E8/32) using the program attached to the end of this paper. The resultant exposure rates obtained by this method were in good agreement, within 10% with those calculated by ordinary formula widely used for a gamma-ray field of known energy and flux. It is concluded that the photen flux obtained by the response matrix constructed under the assumption of $E^{1/2}$ dependence is more realistic than that obtained by the matrix consist of identical energy bins in dosimetrical point of view.

  • PDF

ESR-based Identification of Radiation-Induced Free Radicals in Gamma-Irradiated Basil and Clove Using Different Sample Pre-Treatments (감마선 조사된 바질과 정향의 전처리방법에 따른 ESR Spectra 판별 특성)

  • Kwak, Ji-Young;Ahn, Jae-Jun;Akram, Kashif;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.10
    • /
    • pp.1454-1459
    • /
    • 2012
  • An improved detection of radiation-induced paramagnetic faults was developed to identify the irradiation status of basil and clove. The effectiveness of different sample pretreatments, including freeze-drying (FD), oven-drying (OD), alcoholic-extraction (AE), and water-washing and alcoholic-extraction (WAE), were examined. All non-irradiated samples showed a single central signal ($g_0$=2.006), whereas radicals representing two additional side peaks ($g_1$=2.023 and $g_2$=1.986) with a mutual distance of 6 mT were detected in the irradiated samples. AE and WAE produced the best results for irradiated clove in terms of intensities of radiation-specific ESR signals and their ratios to the central signal. However, FD provided the highest intensities of radiation-specific ESR signals for basil, whereas their ratios to the major signal were better in the cases of AE and WAE. Signal noise, particularly due to $Mn^{2+}$ signals, was observed, whereas it decreased in AE and WAE pretreatments. Based on our results, AE and WAE can improve the detection conditions for radiation-specific ESR signals in irradiated samples.

Cumulative Deposition of $^{137}Cs$ in the Soil of Korea (한국토양에 존재하는 $^{137}Cs$ 방사능 분포)

  • Lee, Myung-Ho;Choi, Yong-Ho;Shin, Hyun-Sang;Kim, Sang-Bog;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.97-102
    • /
    • 1998
  • The cumulative deposition of $^{137}Cs$ in the soil of Korea has been studied. Using ${\gamma$-ray spertrometry, the conrentrations of $^{137}Cs$ were determined for the soil samples collected to a depth of 20 cm. The average accumulated depositions of $^{137}Cs$ were estimated roughly to be 2,501 ${\pm}$ $m^{-2}$ in the forest and 1,058 ${\pm}$ 322 Bq $m^{-2}$ in the hill. The inventory value of $^{137}Cs$ in the forest is about two times higher than that in the hill. Except for some cases, the concentrations of $^{137}Cs$ in the undisturbed soils decreased exponentially with increasing the soil depth. The influences of rainfall, organic matter content, clay content and pH on the deposition of $^{137}Cs$ were studied using the field method. Among these factors, the organic matter content played the most important role in the retention and relative mobility of $^{137}Cs$ in the soil. The other factors such as rainfall, clay content and pH showed weak correlation with the deposition of $^{137}Cs$ in the soil.

  • PDF

Development of Signal Processing Circuit for Side-absorber of Dual-mode Compton Camera (이중 모드 컴프턴 카메라의 측면 흡수부 제작을 위한 신호처리회로 개발)

  • Seo, Hee;Park, Jin-Hyung;Park, Jong-Hoon;Kim, Young-Su;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.16-24
    • /
    • 2012
  • In the present study, a gamma-ray detector and associated signal processing circuit was developed for a side-absorber of a dual-mode Compton camera. The gamma-ray detector was made by optically coupling a CsI(Tl) scintillation crystal to a silicon photodiode. The developed signal processing circuit consists of two parts, i.e., the slow part for energy measurement and the fast part for timing measurement. In the fast part, there are three components: (1) fast shaper, (2) leading-edge discriminator, and (3) TTL-to-NIM logic converter. AC coupling configuration between the detector and front-end electronics (FEE) was used. Because the noise properties of FEE can significantly affect the overall performance of the detection system, some design criteria were presented. The performance of the developed system was evaluated in terms of energy and timing resolutions. The evaluated energy resolution was 12.0% and 15.6% FWHM for 662 and 511 keV peaks, respectively. The evaluated timing resolution was 59.0 ns. In the conclusion, the methods to improve the performance were discussed because the developed gamma-ray detection system showed the performance that could be applicable but not satisfactory in Compton camera application.

A Model for Radiological Dose Assessment in an Urban Environment (도시환경에서 방사성물질 오염에 따른 선량평가모델)

  • Hwang, Won-Tae;Kim, Eun-Han;Jeong, Hyo-Joon;Suh, Kyung-Suk;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • A model for radiological dose assessment in an urban environment, METRO-K has been developed. Characteristics of the model are as follows ; 1) mathematical structures are simple (i.e. simplified input parameters) and easy to understand due to get the results by analytical methods using experimental and empirical data, 2) complex urban environment can easily be made up using only 5 types of basic surfaces, 3) various remediation measures can be applied to different surfaces by evaluating the exposure doses contributing from each contamination surface. Exposure doses contributing from each contamination surface at a particular location of a receptor were evaluated using the data library of kerma values as a function of gamma energy and contamination surface. A kerma data library was prepared fur 7 representative types of Korean urban buildings by extending those data given for 4 representative types of European urban buildings. Initial input data are daily radionuclide concentration in air and precipitation, and fraction of chemical type. Final outputs are absorbed dose rate in air contributing from the basic surfaces as a function of time following a radionuclide deposition, and exposure dose rate contributing from various surfaces constituting the urban environment at a particular location of a receptor. As the result of a contaminative scenario for an apartment built-up area, exposure dose rates show a distinct difference for surrounding environment as well as locations of a receptor.

A Theoretical Calculation of Photon Dose Equivalent Conversion Factor For Extremity Dosimeter (말단선량계의 광자선량당량환산인자에 대한 이론적 계산)

  • Kim, Kwang-Pyo;Lee, Won-Keun;Kim, Jong-Su;Yoon, Yeo-Chang;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.1
    • /
    • pp.41-50
    • /
    • 1996
  • In this study, the theoretical calculation of the air kerma-to-dose equivalent conversion factors was performed with a Monte Carlo N-Particle transport code for the two types of extremity phantom of the ANSI and the KAERI, respectively. Considering the distribution of absorbed dose due to the interaction of homogeneous Parallel broad beam of monoenergetic primary photons in the range between 15keV and 1.5MeV, the air kerma-to-dose equivalent conversion factors based on the kerma approximation were calculated. It is showed that all the theoretical conversion factors of the two types of the extremity phantom for the ANSI and the KAERI agree well with the experimental values of the ANSI N13.32 draft(1995) for each energy within 5.7%, maximum difference ratio, except for 13.6%, difference ratio in the case for the energy of less than 40keV. It is due to uncertainties of experiment occurred in the low X-ray energy range and geometry considered in the MCNP code.

  • PDF