• Title/Summary/Keyword: 감마값

Search Result 447, Processing Time 0.027 seconds

Analysis of Fractional Anisotropy Measurements of Diffusion Tensor Images in the Gyrus of the Brain by AUDIT-K Scale (AUDIT-K 척도에 따른 뇌 이랑 부위의 확산텐서 비등방도 측정값 분석)

  • Kwak, Jong-Hyeok;Kim, Gyeong-Rip;Cho, Hee-Jung;Lee, Eun-Sook;Sung, Soon-Ki
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.7
    • /
    • pp.176-185
    • /
    • 2019
  • Diffusion tensor images were obtained for middle-aged men according to the AUDIT-K scale. As a result of the fractional anisotropy (FA) value of the gyrus nerve fibers in the brain region measured and analyzed by the Tract-Based Spatial Statics, FA values of general drinkers were measured lower than those of estimated alcohol use disabled people. This was statistically significant. In other words, the use of alcohol significantly affects the anatomic microstructural changes measured in the Gyrus of the brain region, and it may damage the nerve fiber tract and affect the functional abnormalities associated with it.

Design of 10bit gamma line system with small size of gate count and 4bit error(LSB) to implement non-linear gamma curve (비선형 감마 커브 구현을 위한 작은 크기와 4bit(LSB) 오차를 가진 10비트 감마 라인 시스템의 설계)

  • Jang, Won-Woo;Kim, Hyun-Sik;Lee, Sung-Mok;Kim, In-Kyu;Kang, Bong-Soon
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2005.11a
    • /
    • pp.353-356
    • /
    • 2005
  • In this paper, the proposed $gamma({\gamma})$ line system is developed for reducing the error between non-linear gamma curve produced by a formula and result produced by hardware implementation. The proposed algorithm and system is based on the specific gamma value 2.2, namely the formula is represented by {0,1}$^{2.2}$ and the bit width of input and out data is 10bit. In order to reduce the error, the system is using least squares polynomial of the numerical method which is calculating the best fitting polynomial through a set of points. The proposed gamma line is consisting of nine kinds of quadratic equations, each with their own overlap sections to get more precise. Based on the algorithm verified by $MATLAB^{TM}$ 7.0, the proposed system is implemented by using Verilog-HDL. The proposed system has 2 clock latency; 1 result per clock. The error range (LSB) is -4 and +3. Its standard deviation is 1.287956238. The total gate count of system is 2,083 gates and the maximum timing is 15.56[ns].

  • PDF

Effects of ${\gamma}-Irradiation$ on the Quality of Seasoned Cuttle during Storage (감마선 조사가 조미오징어의 저장 중 품질특성에 미치는 영향)

  • Noh, Jung-Eun;Kim, Byeong-Keun;Kim, Hyun-Ku;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Culture
    • /
    • v.19 no.5
    • /
    • pp.516-523
    • /
    • 2004
  • This study was conducted to investigate the changes in the qualify of gamma-irradiated seasoned cuttle during storage. Seasoned cuttle packed in PVC film (0.06 win) was stored at $15{\pm}1^{\circ}C$ for 6 months after treatment with doses of 0 to 7 kGy. Microbial populations of seasoned cuttle were $1.6{\times}10^{5}CFU/g$ in total aerobic bacteria, $10^{4}{\sim}10^{5}CFU/g$ in yeasts &molds, and negative in coliforms, which were effectively reduced by 3 kCy or higher up to the undetectable level(<20 CFU/g). The pH and moisture content of the samples were not changed with irradiation, but moisture was some decreased during storage. The instrumental color (especially Hunter b value), pigments (lipophilic &hydrophilic) and TBA value of the samples increased with storage time as well as irradiation dose more than 3 kGy. The influence of storage condition, however, were more significant. Irradiation did not induce any changes in volatile basic nitrogen (VBN) and trimethylamine (TMA) contents, thereby maintaining their contents lower than those of the non-irradiated samples during storage by reducing the microbial load.

Improved characterization method for mobile phone camera and LCD display (모바일 폰 카메라와 LCD의 향상된 특성화 방법)

  • Jang, In-Su;Son, Chang-Hwan;Lee, Cheol-Hee;Song, Kun-Woen;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.2
    • /
    • pp.65-73
    • /
    • 2008
  • The characterization process for the accurate color reproduction in mobile phone with camera and LCD is popular. The camera and LCD characterization, gamut mapping process is necessary to map the camera's input color stimulus, CIEXYZ value, into the LCD's output color stimulus. Each characterization is the process estimating the relation between input and output signals. In case of LCD, because of output device, the output color stimulus for the arbitrary input signal can be measured by spectro-radiometer However, in the camera, as the input device, the characterization is an inaccurate and needs the manual works in the process obtaining the output signal because the input signal can not be generated. Moreover, after gamut mapping process, the noise is increased because the optimized gamma tone curve of camera for the noise is distorted by the characterization. Thus, this paper proposed the system of obtaining the output signal of camera and the method of gamma correction for the noise. The camera's output signal is obtained by RGB values of patches from captured the color chart image. However, besides the illumination, the error for the location of the chart in the viewfinder is generated when many camera modules are captured the chart. The method of correcting the position to correct the error from manual works. The position of camera is estimated by captured image. This process and moving of camera is accomplished repeatedly, and the optimized position can be obtained. Moreover, the lightness curve of camera output is corrected partly to reduce the noise from the characterization process.

Analytical Study on the Handoff Duration Time (핸드오프 시간에 관한 해석적 연구)

  • Lim, Seog-Ku
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.502-507
    • /
    • 2007
  • The handoff area is the region where a call can be handled by two base stations in any of the adjacent cells, and duration time is defined as the time a mobile station resides in the handoff area. It is proven that handoff duration time follows gamma distribution from simulation results[7]. So in this paper, parameters(shape and scale) in gamma distribution are derived by analytic method. And mean, standard deviation, and parameters are compared with simulation results for verification of analytic method.

  • PDF

Mathematics education attitude of the students in the specialized high school (특성화고 학생의 수학교과에 대한 태도 조사)

  • Kim, Minsuk;Oh, Kwangsik
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.6
    • /
    • pp.1173-1181
    • /
    • 2012
  • In order to suggest the basic resources of mathematics education to the specialized high school, we investigate the attitude of students about mathematics education. Questionnaires survey was carried on 654 students and we use the statistical analysis such as chi-square test, gamma, generalized linear model, Anova, regression. Several result can be derived from the questionnaire analysis. There are differences between the general and specialized high school students in the interest, pre-learning ability etc. The specialized school students think the usefulness of mathematics more importantly, while the general school students think more closely related to their course.

Fabrication of Fiber-optics Detector for Measuring Radioactive Waste (방사성 오염도 측정을 위한 광섬유 검출기 제작)

  • Kim, Jeong-Ho;Joo, Koan-Sik
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.282-287
    • /
    • 2015
  • In this study, an optical fiber detector was constructed by using a Ce:GAGG scintillator, optical fiber, and photomultiplier. The single crystal size of the scintillator was set to $3{\times}3{\times}20mm^3$ after simulating the counting efficiency of gamma rays in the scintillator by using the MCNPX code. The constructed detector used the standard gamma ray sources $^{137}Cs$ and $^{133}Ba$ to measure radiation and analyze the spectral characteristics of gamma rays. The resulting trend curve showed excellent linearity with an R-squared value of 0.99741, and the detector characteristics were found to vary 2% or less with distance based on comparison with the MCNPX value. Furthermore, the spectroscopic analysis of the gamma ray energy from the single-ray and mixed-ray sources showed that $^{137}Cs$ had its peak energy at 662 keV, and $^{133}Ba$ had at 356 keV. It seems that if the fiber-optics detector is used, working hours and exposure of worker can be reduced.

Estimation and Application of Reliability Values for Strength of Material Following Gamma Distribution (감마분포를 따르는 재료강도의 신뢰도 예측과 응용)

  • Park, Sung-Ho;Kim, Jae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.223-230
    • /
    • 2012
  • The strength of brittle material has commonly been characterized by a normal distribution or Weibull distribution, but it may fit the gamma distribution for some material. The use of an extreme value distribution is proper when the largest values of a set of stresses dominate the failure of the material. This paper presents a formula for reliability estimation based on stress-strength interference theory that is applicable when the strength of material is distributed like a gamma distribution and the stress is distributed like an extreme value distribution. We verified the validity of the equation for the reliability estimation by examining the relationships among the factor of safety, the coefficient of variation, and the reliability. The required minimum factor of safety and the highest allowable coefficient of variation of stress can be estimated by choosing an objective reliability and estimating the reliabilities obtained for various factors of safety and coefficients of variation.

Calculation of the Air-Scattering Dose Rate by the Single Scattering Approximation (단일산란근사법(單一散亂近似法)에 의한 공기중(空氣中) 산란방사선량(散亂放射線量)의 계산(計算))

  • Yook, Chong-Chul;Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 1979
  • A calculation is presented of air-scattered gamma rays using the modified single-scattering approximation. The air-scattered tissue dose rates are calculated for a general purpose taking into account (a) the buildup and exponential attenuation, (b) the energy spectrum at the position of question and (c) the geometrical scattering volume in three dimensions. These calculations have been further modified to render them applicable to a typical field irradiation facility which is surrounded by a shield wall and in which the source is fitted with a beam collimating device. The results of the calculation include the energy spectra, angular distribution and tissue does rates at source-receiver separation distances of from 35m to 300m. The comparison shows that the present method developed may be generally adequate for the gamma-ray air-scattering problems in field irradiation facilities if energy and angular distribution at the shield are unimportant.

  • PDF

Measurements of the Direction and Polarization Correlation for Cascade Gamma-rays of Co-60 and Cs-134 (Co-60과 Cs-134의 연발감마선에 대한 방향 및 편극상관 측정)

  • Hyung-Ju Woo;Kie-Hyung Chung;Hae-Ill Bak
    • Nuclear Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.64-69
    • /
    • 1982
  • Directional correlation measurements for the Co-60 and Cs-134 cascade gamma-rays have been performed in the angular range from 90$^{\circ}$ to 180$^{\circ}$ by use of the fast coincidence scintillation spectrometer incorporated with a gamma-ray polarimeter based on the Compton scattering effect to determine the polarization correlations. The experimental method together with the theoretical background is described, and the results are shown graphically to represent the consistency of the measurement with approximate theoretical estimates.

  • PDF