• Title/Summary/Keyword: 간 초음파 영상

Search Result 230, Processing Time 0.033 seconds

Real-time Ultrasound Contexts Segmentation Based on Ultrasound Image Characteristic (초음파 영상 특성을 이용한 실시간 초음파 영역 추출방법)

  • Choi, Sung Jin;Lee, Min Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.179-188
    • /
    • 2019
  • In ultrasound telemedicine, it is important to reduce the size of the data by compressing the ultrasound image when sending it. Ultrasound images can be divided into image context and other information consisting of patient ID, date, and several letters. Between them, ultrasound context is very important information for diagnosis and should be securely preserved as much as possible. In several previous papers, ultrasound compression methods were proposed to compress ultrasound context and other information into different compression parameters. This ultrasound compression method minimized the loss of ultrasound context while greatly compressing other information. This paper proposed the method of automatic segmentation of ultrasound context to overcome the limitation of the previously described ultrasound compression method. This algorithm was designed to robust for various ultrasound device and to enable real-time operation to maintain the benefits of ultrasound imaging machine. The operation time of extracting ultrasound context through the proposed segmentation method was measured, and it took 311.11 ms. In order to optimize the algorithm, the ultrasound context was segmented with down sampled input image. When the resolution of the input image was reduced by half, the computational time was 126.84 ms. When the resolution was reduced by one-third, it took 45.83 ms to segment the ultrasound context. As a result, we verified through experiments that the proposed method works in real time.

Surgical Resection of Renal Cell Carcinoma Extended to the Inferior Vena Cava Using Pump Driven Veno-venous Bypass (정맥-정맥간 우회술을 이용하여 하대정맥까지 확장된 콩팥세포암종의 수술적 치료 1예)

  • Park Han Gyu;Choi Chang Woo;Lee Jae Wook;Her Keun;Shin Hwa Kyun;Won Yong Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.72-75
    • /
    • 2006
  • In a 40 year-old man who has complained of epigastric pain and dyspnea for 10 days including melena for 1 month, abdominal ultrasonography and computerized tomography revealed a large, solid mass in the right kidney and thrombus of inferior vena cava (IVC) that extended to the cavoatrial junction. Renal cell carcinoma was performed by percutaneous needle biopsy. IVC thromboembolectomy was performed using centrifugal pump driven venovenous bypass without cardiac arrest and cardiopulmonary bypass (CPB).

A Case of Infantile Hepatic Hemangioendothelioma Incidentally Detected during the Evaluation of Galactosemia (선천성 갈락토스혈증으로 오인된 신생아 간 내 혈관내피종 1례)

  • Lim, Ryoung-Kyoung;Byun, Shin-Yun;Park, Seong-Shik;Kim, Young-Don
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.136-140
    • /
    • 2010
  • Galactosemia is a group of inherited enzyme deficiencies characterized by increase in the blood galactose levels. This condition may be associated with deficiencies of galactose-1-phosphate uridyl transferase, galactokinase, or uridine diphosphate galactose-4-epimerase. However, the elevated galactose identified by neonatal screening tests has several other possible etiologies, including hepatic hemangioendothelioma, hepatic hemangioma, and patent ductus venosus with hypoplasia of the portal vein. We report a 13-day-old Korean male with hepatic hemangioendothelioma, which was incidentally detected during the evaluation for suspected galactosemia. Laboratory studies revealed that mildly elevated levels of galactose, galactose-1-phosphate and alpha- fetoprotein, at the time of admission, were graduallydecreased to the normal range over the 6 months of observation. Ultrasonography showed a well-defined heterogeneous hypoechoic mass in the liver, and magnetic resonance imaging study showed multiple enhanced mass lesions, which was compatible with the diagnosis of a hepatic hemangioendothelioma. Thus, hepatic imaging, especially ultrasonography, should be performed if neonatal screening suggests galactosemia.

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.

The Use of Real-Time Ultrasound Imaging for Feedback during Abdominal Hollowing (복부 할로잉 운동에서 실시간 초음파 영상 피드백의 사용 효과)

  • Kwon, Nam-Hee;Lee, Hyun-Ok;Park, Du-Jin
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.3
    • /
    • pp.303-310
    • /
    • 2011
  • Purpose : This study examined the feedback effect of real-time ultrasound imaging on the thickness of transversus abdominis(TrA), internal abdominal oblique(IO) and external abdominal oblique(EO) during abdominal hollowing exercise(AHE) in crook lying. Methods : We performed this study on 30 healthy men who voluntarily consented to participate in this study after listening to its purpose and method. All subject were divided into an experimental group(n=15) with using the real-time ultrasound imaging feedback(RUIF) and a control group(n=15) without the RUIF The thickness changes between rest and AHE were compared between the two groups in crook lying. Results : The difference in TrA and EO thickness changes between the groups were significant in crook lying (p<0.05). Conclusion : The group with using real-time ultrasound imaging feedback showed a higher increase in the thickness of TrA than the other group without real-time ultrasound imaging feedback. And the thickness of EO in the group with using real-time ultrasound imaging feedback decreased than the other group without real-time ultrasound imaging feedback. If the muscle thickness can be regarded as an indicator of muscle activity, RUIF will be helpful for inducing the independent activity of TrA by reducing the activities of abdominal muscles such as EO.

A Correlation Study Using the Sonogram Between the Muscle Strength and the Diameter of Biceps Brachii Muscle (윗팔두갈래근의 근력과 근육직경 간의 상관성에 대한 초음파 영상 연구)

  • Kim, Jeong-Seon;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.1
    • /
    • pp.9-14
    • /
    • 2011
  • Background: The purpose of our experimental study, we want to know a correlation study using the sonogram between the muscle strength and the diameter of Biceps brachii muscle by gender. So we set to hypothesis that Biceps brachii contracted maximally would be a diameter of the muscles increased according to the muscle strength will be increased. Methods: In this study, we measured the muscle strength of biceps brachii on contracting its maximum using the Biodex and the diameter of the muscles using Myo-Lab (25Gold). We experimented 30 subjects of twenty-aged men and women. The subjects is comprised of a persons who has not external injuries and pain of elbow joint, no mobility limitation of ROM, no experiences of surgery in past history. Result: We found that the men have a highly correlation between maximum strength and the diameter of the muscles more than women (p<.05). Conclusion: The results of our experimental study between the muscle diameter and the muscle strength to biceps brachii on relaxation and contraction is a statistically significant relation (r=.394), especially in rather men then women (p<.05). So this results would be based data for further clinical muscle efficiency application in physical therapy field.

  • PDF

A Hybrid Navigation System for Intelligent Wheelchair (지능형 휠체어를 위한 하이브리드 내비게이션 시스템)

  • Ko, Eun-Jeong;Ju, Jin-Sun;Kim, Eun-Yi
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.552-557
    • /
    • 2009
  • In this paper, we propose hybrid navigation system, for obstacle detection and avoidance in Intelligent wheelchairs (IWs). To robustly detect obstacles and avoid them on various environments, hybrid navigation system combines both range-sensor and camera information. For this, 10 range-sensors (2 ultrasonic and 8 infra-red sensors) and CCD camera are used. Through processing the informations obtained from those sensors, our system can detect obstacles with various sizes and shapes, and then avoid them. To assess the effectiveness of the proposed hybrid navigation system, it was tested on complex environments including various obstacles, then the results showed the potential of our system as mobility aids for disabled people.

  • PDF

Extraction of Ganglion from Ultrasonic Images by Using Enhanced Fuzzy Stretching and Fuzzy Clustering Method (개선된 퍼지 스트레칭 기법과 퍼지 클러스터링 기법을 이용한 초음파 영상에서의 결절종 추출)

  • Park, Jae-Woo;Park, Ji-Hun;Cho, Jae-Hun;Oh, Heung-Min;Kim, Kwang Baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.478-481
    • /
    • 2017
  • 본 논문에서는 기존의 삼각형 타입의 퍼지 스트레칭을 개선한 사다리꼴 형태의 퍼지 스트레칭 기법과 FCM 기반 양자화 기법을 적용하여 결절종을 추출하는 방법을 제안한다. 제안된 결절종 추출방법은 결절종 영역과 그 외의 영역 간의 명암 대비를 강조하기 위해 사다리꼴 형태의 퍼지 스트레칭 기법을 적용한 후에 Monotone Cubic Spline 기법을 적용하여 ROI 영역을 추출한다. 추출된 ROI 영역에 대해 FCM 기반 양자화 기법을 적용하고 양자화된 결과를 이용하여 ROI 영역을 이진화한다. 결절종이 타원 형태와 명암도가 낮은 값을 가진다는 형태학적 특징을 이용하기 위해서 이진화 ROI 영역에 팽창 기법을 적용하여 결절종의 후보 영역을 추출하고 8방향 윤곽선 추적 알고리즘을 적용하여 잡음 영역이 제거한다. 잡음이 제거된 결절종 후보 영역에서 최종 결절종 영역을 추출하기 위해 라벨링 기법을 적용한다. 제안된 결절종 추출 방법의 성능을 분석하기 위해서 20명의 환자를 대상으로 20장을 실험한 결과, 기존의 방법보다 TPR(Ture Positive Rate)이 높게 나타나는 것을 확인하였다.

  • PDF

A Study on Location Tracking Streetlight (위치추적 가로등에 관한 연구)

  • Kim, Bum-Su;Kim, Seung-Goo;Song, Hyeong-Ho;Kim, Bo-Ryeon;Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1275-1280
    • /
    • 2018
  • We made a smartphone interlocking location tracking streetlight and remote display device to compensate the defect of real time identifiable CCTV streetlights and child safety notification applications. It controls brightness of LED by detecting the surrounding brightness and objects with ultrasonic sensor and illuminance senor. The CCTV receives the location of smartphone by Bluetooth and takes the target of the location. It realizes a wireless transmission system that the video is upload to the tablet PC via WiFi.