• Title/Summary/Keyword: 간 종양

Search Result 693, Processing Time 0.026 seconds

Morphological features for Automated diagnosing Noninvasive Mucinous Cystic neoplasm (비침습성 점액성 낭성종양의 자동화된 진단을 위한 형태학적 특징들)

  • Song, Jae-Won;Lee, Ju-Hong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06b
    • /
    • pp.513-515
    • /
    • 2012
  • 본 논문은 간의 비침습성 점액성 낭성종양의 자동화된 진단을 위한 정량적인 형태학적 추출방법에 대하여 설명한다. 본 논문에서 제안된 형태학적 추출방법은 간의 비침습성 점액성 낭성종양 진단을 위한 병리적인 특징들에 기반을 둔 상피세포 형태학적 특징(원주형과 입방형)과 악성 직전에 나타나는 배상세포 출연을 판단하는 특징, 그리고 주변상피 조직에서 나타나는 기질 여부를 조사하기 위한 핵-비율의 측정방법을 소개한다.

Solitary Hepatic VX2 Tumor Model and Its CT Findings in Rabbits (가토에서 VX2 단일간암모델과 CT 소견)

  • Lee, Hae-Beom;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.388-392
    • /
    • 2006
  • To verify the solitary nodular hepatocellular tumor model induced by intraparenchymal VX2 tumor cell injection and assess the diagnostic imaging character by computed tomography in rabbits. The tumor cell fragment ($1{\sim}2mm^3$) was loaded in Seldinger needle and directly implanted into the livers of 80 New Zealand white rabbits. The tumor size and patterns of tumor growth were evaluated using spiral computed tomography (CT) at 1, 2, and 3 weeks after tumor implantation. A solitary nodular tumor was successfully created in 82.5% (66/80). The mortality rate was 5% (4/80). The tumor sizes measured were 7.46.3, 14.210.8, 16.212.6 cm at 1, 2, and 3 weeks after tumor implantation on arterial phase CT images. The tumors were round to oval shape with peripheral enhancement and central hypoattenuation on arterial phase, and hypoatteuated wash-out pattern on portal phase. It is considered that inoculation of tumor fragment loaded in Seldinger needle is useful and practical method for creating a solitary hepatic tumor. And CT scanning are valuable to investigate the hepatic tumor and compatible to the observations on macro-and microscopic findings.

Relationship between Stomach Volume and Tumor Location in Radiation Treatment for Hepatic Tumors (간 종양의 방사선치료에서 위내용적과 종양 위치 간의 관계)

  • Jeon, Mi-Jin;Lee, Chang-Geol;Lee, Ik-Jae;Choi, Won-Hoon;Choi, Yun-Sun;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Suk;Cho, Yoon-Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.75-83
    • /
    • 2010
  • Purpose: It aims to evaluate the location change and tendency of hepatic and intrahepatic tumors according to gastric volume and change of location. Materials and Methods: It studied 9 patients with hepatic tumors who visited Gangnam Severance Hospital from March 2009 to April 2010 and who underwent CT or PET (Positron Emission Tomography) within 2 weeks before CT-simulation. The patients fasted for 6 hours before CT-simulation and drank 240~250 cc of water just before CT or PET for image fusion. Those two types of images were fused to RTP (Radiation Treatment Planning, Pinnacle 8.0h) focusing on bone structure of individual patients. Results: They drank 240~260 cc of water but their stomach volume after drinking water varied from 259.3 cc to 495.4 cc. Even though individual differences existed in the change of stomach volume before and after drinking water, the volume was increased by 130 cc (174%) on average. The change in absolute distance between the centers of tumors ranged from 0.52 cm to 3.04 cm (1.52 cm on average); from 0.1 cm to 1.35 cm (0.44 cm on average) in cranial-caudal direction; from 0.05 cm to 2.75 cm (1.22 cm on average) in left-right direction; and from 0.05 cm to 1.85 cm (0.33 cm on average) in ventral-dorsal direction. Conclusion: It is hard to predict the movement of tumors by observing stomach movement, due to great individual differences; however, it was observed that the location of hepatic tumors was right-sided as the stomach was filled with water. Thus, it is recommended to maintain the fastened state to secure the accuracy of hepatic tumor treatment. If it cannot maintain the fastened state, it is recommended to measure stomach volumes and movement in the patient to consider the movement of hepatic tumors before radiation treatment.

  • PDF

Analysis of Dose Distribution on Critical Organs for Radiosurgery with CyberKnife Real-Time Tumor Tracking System (사이버나이프 실시간 종양추적 시스템을 이용한 방사선수술 시 주요 장기의 선량분포 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Ji, Young-Hoon;Kim, Kum-Bae;Lee, Sang-Hoon;Choi, Jin-Ho;Lee, Re-Na;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • We measured the dose distribution for spinal cord and tumor using Gafchromic film, applying 3D and 4D-Treatment Planning for lung tumor within the phantom. A measured dose distribution was compared with a calculated dose distribution generated from 3D radiation treatment planning and 4D radiation treatment planning system. The agreement of the dose distribution in tumor for 3D and 4D treatment planning was 90.6%, 97.64% using gamma index computed for a distance to agreement of 1 mm and a dose difference of 3%. However, a gamma agreement index of 3% dose difference tolerence of and 2 mm distance to agreement, the accordance of the dose distribution around cord for 3D and 4D radiation treatment planning was 57.13%, 90.4%. There are significant differences between a calculated dose and a measured dose for 3D radiation treatment planning, no significant differences for 4D treatment planning. The results provide the effectiveness of the 4D treatment planning as compared to 3D. We suggest that the 4-dimensional treatment planning should be considered in the case where such equipments as Cyberknife with the real time tracking system are used to treat the tumors in the moving organ.

  • PDF

The Clinicopathologic Characteristics of Neuroendocrine Tumor of the Stomach (위에 발생한 신경내분비 종양의 임상병리학적 고찰)

  • Lee, Chul-Min;Shin, Yeon-Myung
    • Journal of Gastric Cancer
    • /
    • v.8 no.4
    • /
    • pp.204-209
    • /
    • 2008
  • Purpose: The goal of this study was to review the clinicopathologic characteristics of neuroendocrine tumor (NET) of the stomach. Materials and Methods: We retrospectively reviewed the medical records of 13 patients who were diagnosed with neuroendocrine tumor from January 1999 to August 2007 at Kosin Medical Center; 4,159 gastric cancer patients were treated surgically during the same time. The average follow up period was 14.3 months. Results: The majority of 13 patients were men (male-female ratio: 11:2) and the average age of patients with NET was 59.4 years (range: 42~72 years). The presenting symptoms were mostly epigastric pain and soreness. The tumor was limited to the mucosa or submucosa in two cases, and the tumor extended beyond the muscle layer in 11 cases. The mean size of the tumor was 7.0 cm, ranging from 0.7 cm to 15 cm. The type of the NEC (according to the WHO classification) was type 3 for eight patients, type 4 for four patients and type 1 for one patient. Regional lymph node metastasis was noted in 11 patients. Four cases showed recurrence of disease and the site of recurrence included liver in two patients, multiple organs (including the peritoneum and lung) in one patient and multiple organs (including liver, pancreas and duodenum) in one patient. The recurrent cases were type 3 and type 4 and the average survival period of the recurrent patients was 12.8 months. Conclusion: The majority of neuroendocrine tumors of the stomach were at an advanced stage at the time of diagnosis. These tumors frequently recurred in the liver and they have a poor prognosis.

  • PDF

Hepatic Pseudolymphoma Mimicking a Hypervascular Tumor: A Case Report (과혈관성 종양으로 오인된 간의 가성림프종: 증례보고)

  • Im, Bora;Jang, Suk Ki;Yeon, Jae Woo;Paik, So Ya;Park, Sang Jong;Kim, Hyuk Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.348-353
    • /
    • 2018
  • Hepatic pseudolymphoma is a rare benign liver mass that is characterized by proliferation of non-neoplastic lymphocytes extranodally. To the best of our knowledge, only 46 cases have been reported in the English literature. We described the case of a 75-year-old woman with hepatic pseudolymphoma mimicking a hypervascular tumor. After the histological confirmation of the rectal neuroendocrine tumor, CT scan revealed a 1.0 cm-sized, poorly-defined and low-density nodule in the liver. On MRI, the hepatic nodule showed an arterial enhancement and a low-signal intensity on the hepatobiliary phase. On diffusion-weighted imaging, the hepatic nodule showed a high signal intensity on a high b-value. On fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT, it revealed a high standardized uptake value nodule. The US showed the hypoechoic nodule and the US-guided biopsy confirmed the hepatic pseudolymphoma.

Chest Wall Metastasis from Unknown Primary Hepatocellular Carcinoma -A case report - (원발성 종양의 증거 없이 발생한 간세포암종의 흉벽 전이 -1예 보고-)

  • Kim, Hyuck;Yang, Joo-Min;Kang, Jung-Ho;Kim, Young-Hak;Chung, Won-Sang;Chon, Soon-Ho
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.809-812
    • /
    • 2004
  • Chest wall metastases from malignant tumors are rare and the majority of them are from adjacent structures such as the breast, lung, pleura, and mediastinum. Paticularly, chest wall metastases from distant organs are an even rarer event. There are few reports of chest wall metastasis with obscure or absent primary tumor. A 51-year-old man was diagnosed with metastatic hepatocellular carcinoma after an operation for a palpable mass on his left upper chest wall, At that time, there was no evidence of primary hepatocellular carcinoma in the liver after various examinations. We report a case of chest wall metastasis from unknown primary hepatocellular carcinoma.

A Case of Pancreatic Cancer Recurred in Liver after Surgical Resection, in Complete Response after Chemotherapy and Tumorectomy (수술적 절제술 후 간에 재발한 췌장암에서 항암화학요법과 종양절제술로 완전 관해를 보인 증례)

  • Jun Hyuk Son;Jae Woo Lee;Dong Kee Jang;Sang Hyub Lee;Ji Kon Ryu;Yong-Tae Kim
    • Journal of Digestive Cancer Research
    • /
    • v.3 no.2
    • /
    • pp.105-107
    • /
    • 2015
  • Pancreatic cancer is commonly presented with distant metastasis. However metastasis to central nervous system (CNS) of pancreatic cancer was rarely reported. 79-years-old man was hospitalized with sudden onset right arm dysesthesia and weakness. In brain magnetic resonance imaging, multifocal high signal intensity lesions in cerebral and cerebellar cortices were observed. Leptomeningeal and parenchymal enhanced lesions were also noted in contrast-enhanced T1 images suggesting a metastasis from the pancreatic cancer. Stroke like manifestation of CNS metastasis of pancreatic cancer is extremely rare. Careful history taking and evaluation should be performed to find the origin of the sudden neurologic deficit.

  • PDF

Verification of X-sight Lung Tracking System in the CyberKnife (사이버나이프에서 폐종양 추적 시스템의 정확도 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Ki;Cho, Kwang-Hwan;Lee, Sang-Hoon;Choi, Jin-Ho;Lim, Sang-Wook;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • To track moving tumor in real time, CyberKnife system imports a technique of the synchrony respiratory tracking system. The fiducial marker which are detectable in X-ray images were demand in CyberKnife Robotic radiosurgery system. It issued as reference markers to locate and track tumor location during patient alignment and treatment delivery. Fiducial marker implantation is an invasive surgical operation that carries a relatively high risk of pneumothorax. Most recently, it was developed a direct lung tumor registration method that does not require the use of fiducials. The purpose of this study is to measure the accuracy of target applying X-sight lung tracking using the Gafchromic film in dynamic moving thorax phantom. The X-sight Lung Tracking quality assurance motion phantom simulates simple respiratory motion of a lung tumor and provides Gafchromic dosimetry film-based test capability at locations inside the phantom corresponding to a typical lung tumor. The total average error for the X-sight Lung Tracking System with a moving target was $0.85{\pm}0.22$ mm. The results were considered reliable and applicable for lung tumor treatment in CyberKnife radiosurgery system. Clinically, breathing patterns of patients may vary during radiation therapy. Therefore, additional studies with a set real patient data are necessary to evaluate the target accuracy for the X-sight Lung Tracking system.

  • PDF