• Title/Summary/Keyword: 간헐적 주입

Search Result 43, Processing Time 0.022 seconds

Development of Sewage Treatment Apparatus for Detached House in Agricultural Village by Natural Purification Method (자연정화공법에 의한 농촌 전원 독립가구 하수처리장치 개발)

  • Seo, Dong-Cheol;Park, Mi-Ryoung;Kim, Hyung-Jun;Cho, In-Jae;Lee, Hong-Jae;Sung, Sun-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.202-210
    • /
    • 2006
  • To develop small-scale sewage treatment apparatus for detached house of agricultural village, a small-scale sewage treatment apparatus by natural purification method that consisted of packaged form of aerobic, anoxic and anaerobic bed was constructed. The efficiency of sewage treatment according to the sewage treatment method, sewage loading, and the injection method of sewage were investigated for small-scale sewage treatment apparatus of packaged form of aerobic, anoxic and anaerobic bed. The removal rate of pollutants according to the sewage treatment method for small-scale sewage treatment apparatus was high in the order of aerobic-anoxic-anoxic bed < aerobic-anoxic-anaerobic bed. The optimum filter media in small-scale sewage treatment apparatus was a broken stone. The removal rate of pollutants according to sewage loading in small-scale sewage treatment apparatus was high in the order of $1,200L/m^2{\cdot}day\fallingdotseq900L/m^2{\cdot}day\fallingdotseq600L/m^2{\cdot}day$. The removal rate of pollutants according to injection method of sewage in small-scale sewage treatment apparatus was high in the order of continuous injection $\fallingdotseq$ intermittent injection. When loaded under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P were 99, 95, 99, 83 and 96%, respectively, through this 3-stepped small-scale treatment apparatus arrayed with the order of aerobic, anoxic and anaerobic bed.

Assessment of Optimum Hydraulic Retention Time (HRT) for Maximum Biogas Production and Total Volatile Solid (TVS) Removal Efficiency of Semi-Continuously Fed and Mixed Reactor (SCFMR) Fed with Dairy Cow Manure (젖소분뇨로부터 최대 바이오가스 생산과 유기물 제거효율을 달성하기 위한 반건식 간헐주입 연속혼합 혐기성반응조의 최적 수리학적 체류시간 도출을 위한 연구)

  • Kang, Ho;Kim, Sun-Woo;Jeong, Ji-Hyun;Ahn, Hee-Kwon;Jung, Kwang-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.12
    • /
    • pp.696-704
    • /
    • 2015
  • This study was carried out to evaluate the optimum operational condition of Semi-continuously Fed and Mixed Reactor (SCFMR) to treat the dairy cow manure and saw dust mixture. Step-wise increase in organic loading rates (OLRs) or decrease in hydraulic retention times (HRTs) were utilized until the biogas volume became significantly decreased at mesophilic temperature ($35^{\circ}C$). The optimum operating condition of the SCFMR fed with TS 13% dairy cow manure and saw dust mixture was found to be an HRTs of 25 days and its corresponding OLRs of $4.45kg\;VS/m^3-day$. At this condition the biogas and methane production rates were 1.44 v/v-d and 1.12 v/v-d (volume of biogas per volume of reactor per day), respectively and the TVS removal efficiency of 37% was achieved. The successful operation with such a high OLR was due to the high reactor alkalinity concentration of 14,500~15,600 mg/L as $CaCO_3$ as a result of the characteristic of the original substrate, dairy cow manure and saw dust mixture whose alkalinity was more than 8,000 mg/L as $CaCO_3$. The parameters for the reactor stability, the ratios of volatile acids and alkalinity concentrations (V/A) and the ratio of propionic acid and acetic acid concentrations (P/A) appeared to be 0.11 and 0.43, respectively, that were greatly stable in operation. Free ammonia toxicity was not experienced due to the long term acclimation by the reactor TS content ranged 7.2~10.4% during the entire operational period.

The Changes of Cuff Pressure from Endotracheal Intubation for Long-term Mechanical Ventilation (장기간 기계호흡 환자에서 기관내 관의 기낭압의 변화)

  • Jung, Bock-Hyun;Park, Whan;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.2
    • /
    • pp.156-165
    • /
    • 2002
  • Background: A tracheal stenosis is caused by mucosal ischemic injury related to a high cuff pressure ($P_{cuff}$) of the endotracheal tube. In contrast, aspiration of the upper airway secretion and impaired gas exchange due to cuff leakage is related to a low $P_{cuff}$. To prevent these complications, the $P_{cuff}$ should be kept appropriately because the appropriate $P_{cuff}$ appears to change according to the patient's daily respiratory mechanics. However, the constant cuff volume($V_{cuff}$) has frequently been instilled to the cuff balloon on a daily basis to maintain the optimal $P_{cuff}$ instead of monitoring the $P_{cuff}$ directly at the patients' bedside. To address the necessity of continuous $P_{cuff}$ monitoring, the change in the $P_{cuff}$ was evaluated at various $V_{cuff}$ levels on a daily basis in patients with long-term mechanical ventilation. The utility of mercury column sphygmomanometer for the continuous monitoring $P_{cuff}$ was also investigated. Method: The change in $P_{cuff}$ according to the increase in $V_{cuff}$ was observed in 17 patients with prolonged endotracheal intubation for mechanical ventilation for 2 week or more. This maneuver measured the change in $P_{cuff}$ daily during the mechanical ventilation days. In addition, the $P_{cuff}$ measured by mercury column sphygmomanometer was compared with the $P_{cuff}$ measured by an automatic cuff pressure manager. Results : There were no statistically significant changes of $P_{cuff}$ during more than 14 days of intubation for mechanical ventilation. However the $V_{cuff}$ required to maintain the appropriate $P_{cuff}$ varied from 1.9 cc to 9.6 cc. In addition, the intra-individual variation of the $P_{cuff}$ was observed from 10 $cmH_2O$ to 46 $cmH_2O$ at constant 3 cc $V_{cuff}$. The $P_{cuff}$ measured by the bedside mercury column sphygmomanometer is well coincident with that measured by the automatic cuff pressure manager. Conclusion: Continuous monitoring and management of the $P_{cuff}$ to maintain the appropriate $P_{cuff}$ level in order to prevent cuff related problems during long-term mechanical ventilation is recommended. For this purpose, mercury column sphygmomanometer may replace the specific cuff pressure monitoring equipment.

Study on Overcoming Interference Factor by Automatic Synthesizer in Endotoxin Test (내독소 검사에서 자동합성장치에 따른 간섭요인 극복에 대한 연구)

  • Kim, Dong Il;Kim, Si Hwal;Chi, Yong Gi;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.3-6
    • /
    • 2012
  • Purpose : Samsung medical ceter shall find a cause of the interference factor and suggest a solution for it. Materials and Methods : A sample of $^{18}F$-FDG, radioactive pharmaceuticals produced by TRACERlab MX and FASTlab synthesizer. Gel-clot method uses Positive control tube and single test tube. Kinetic chromogenic method uses ENDOSAFE-PTS produced by Charles River. Results : According to Gel clot method of Endotoxin Tests at FASTlab, both turbidity and viscosity increased at 40-fold dilution and Gel clot was detected. In case of TRACERlab MX, Gel clot was detected in most of samples but intermittently not in a few of them. When using ENDOSAFE-PTS, sample CV (Coefficient of Variation) of FASTlab is 0% at all dilution rates whereas spike CV is 0% at 1-fold dilution, 0~35% at 10-fold, 3.6~12.9% at 20-fold, 5.2~7.1% at 30-fold, 1.1~17.4% at 40-fold, spike recovery; 0% at one-fold, 25 ~ 58% at 10-fold, 50 ~ 86% at 20-fold, 70~92% at 30-fold, and 75~120% at 40-fold. Sample CV of TRACERlab MX, is 0% at all dilution rates whereas spike CV is 1.4~4.8% at one-fold dilution, 0.6~19.9% at 10-fold, spike recovery; 35~72% at one-fold dilution and 77~107% at 10-fold. Conclusion : Gel clot does not seem to occur probably to H3PO4 which engages in bonding with Mg2+ion contributing gelation inside PCT. Dilution which is identical to reducing the amount of H3PO4, could remove interfering effects accordingly. Spike recovery was obtained within 70~150% - recommended values of supplier - at 40-fold dilution even in kinetic chromogenic method.

  • PDF

Use of Undiluted Potassium Solution in Intermittent Antegrade Warm Blood Cardioplegia (IAWBC) (간헐적 전방온혈심정지액에서 희석되지 않은 고농도 포타슘의 사용)

  • 백완기;손국희;김영삼;윤용한;김혜숙;임현경;이춘수;김광호;김정택
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.660-664
    • /
    • 2004
  • Background: Dilution of blood cardioplegia is not needed in IAWBC as it is in cold blood cardioplegia because it does not aggregate red blood cells on normal body temperature and does not compromise micro coronary circulation. This study was designed to evaluate the safety and efficacy of undiluted potassium solution in IAWBC. Material and Method: Thirty patients who underwent CABG with IAWBC were grouped into dilutedplegia (n=14) and microplegia (n=16). Potassium was delivered conventionally with 4 : 1 delivery kit in the dilutedplegia group. The undiluted potassium was directly connected on the blood of oxygenator in the microplegia group. Result: There were no differences in sex, age, left ventricular ejection fraction, number of grafts, aortic cross clamping time, and the value of perioperative myocardial enzyme between the two groups. There were no perioperative myocardial infarction and hospital mortality. The amount of crystalloid cardioplegia was 1346$\pm$597 mL in dilutedplegia (mean$\pm$standard deviation, and 28$\pm$9 mL in microplegia (p<0.0001). The hematocrit during cardiopulmonary bypass was 21$\pm$4% in dilutedplegia and 24$\pm$3% in microplegia (p>0.05). 11 patients in dilultedplegia received blood transfusion, but 4 patients in microplegia received blood transfusion (p<0.05). The amount of urine and hemofiltration during the operation were more in dilutedplegia (1250$\pm$810 mL, 1689$\pm$548 mL) than in microplegia (959$\pm$410 mL, 1461$\pm$784 mL; p<0.05). Conclusion: The undiluted potassium of IAWBC in CABG operation is a safe, effective technique for myocardial protection to prevent fluid overload, and blood transfusion. There is no need to use the delivery kit.

Pulmonary Oxalosis Caused by Aspergillus Niger Infection (Aspergillus Niger 감염에 의한 폐옥살산염 1예)

  • Cho, Gye Jung;Ju, Jin Young;Park, Kyung Hwa;Choi, Yoo-Duk;Kim, Kyu Sik;Kim, Yu Il;Kim, Soo-Ok;Lim, Sung-Chul;Kim, Young-Chul;Park, Kyung-Ok;Nam, Jong-Hee;Yoon, Woong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.516-521
    • /
    • 2003
  • The Aspergillus species produces metabolic products that play a significant role in the destructive processes in the lung. We experienced a case of chronic necrotizing pulmonary aspergillosis caused by an Aspergillus niger infection, which contained numerous calcium oxalate crystals in the necrotic lung tissue. A 46-year-old man, who had a history of pulmonary tuberculosis, presented with high fever, intermittent hemoptysis and pulmonary infiltrations with a cavity indicated by the chest radiograph. Despite being treated with several antibiotics and anti-tuberculosis regimens, the high fever continued. The sputum cultures yielded A. niger repeatedly, and intravenous amphotericin B was then introduced. The pathological specimen obtained by a transbronchial lung biopsy revealed numerous calcium oxalate crystals in a background of acute inflammatory exudates with no identification of the organism. Intravenous amphotericin B was continued at a total dose of 1600 mg, and at that time he was afebrile, although the intermittent hemoptysis continued. On the $63^{rd}$ hospital day, a massive hemoptysis (about 800 mL) developed, which could not be controlled despite embolizing the left bronchial artery. He died of respiratory failure the next day. It is believed that the oxalic acid produced by A. niger was the main cause of the patient's pulmonary injury and the ensuing massive hemoptysis.

Characteristics of Coagulation Treatment for Wood Tar Waste Water in a Biomass Gasification Plant (바이오매스 가스화 발전설비의 목질계 타르폐수 응집 처리 특성)

  • Kim, I tae;Ahn, Kwangho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.573-577
    • /
    • 2015
  • There are difficulties in removing wood tar wastewater coming from the power plants that use wood-based fuels due to its intermittent occurrences and severe changes in the amount and concentration. This study investigated the treatment characteristics through physicochemical treatment, an improved method from the existing ones using bag filters and activated carbons to treat wood tar wastewater. In the case of chemical properties of wood tar wastewater, the content of phenols was found to be more than two times higher than that of guaiacols and carbohydrates. Installation is done to ensure that NaOH and PAC are injected automatically according to the change of pH, and then pH, turbidity and SS of the final treated water were examined. The results were 5.9, 12.6 NTU and 15.1 mg/L respectively, which confirmed the possibility of the treated water as circulation water of power plants. In the physical treatment process using a conventional bag filter, removal efficiency of chemicals was about 20%, but the treatment efficiency was improved to show chemical removal efficiency of about 80% through flocculation and sedimentation.

Differentiation Trend of Rare Earth Elements of the Skaergaard Intrusion (Skaergaard 암체의 희토류의 분화경향)

  • Yun D. Jang
    • Economic and Environmental Geology
    • /
    • v.34 no.6
    • /
    • pp.617-625
    • /
    • 2001
  • The Skaergaard intrusion is widely considered a type example of a strongly fractionated, layered intrusion that has undergone extensive in situ igneous differentiation. The Intrusion, therefore, should be a good locality for modeling trace element vriation in a closed system. Previous studios (Haskin and Haskin, 1968; Faster et al., 1974), however, have suggested thats the rare earth elements in whole rocks and mineeral separates from the Intrusion did not fellow the expected trend for closed system crystatllization. Trace element modeling using published distribution coefficients, modal abundances of the coexisting minerals, and the concentration of trace elements In whole rocks and mineral separates from the Skaergaard Intrusion, reveals that the rare earth elements were significantly Influenced by the crystallization of abundant apatite in the Layered Series suring the final stages of crystallization. The results of trace element modeling also suggcsts that apatite, which appears sporadically in the UBS, is not a primary liquidus phase in these samples as previously suggested (Naslund, 1984) but an interstitial phase that (lid not directly effect trace element abundances In the evolving magma As the Skaergaard magma coaled convection, or convected as small Isolated cells during the final stages of differentiation, an elebated $P_{H2O}$ Induced by accumulation of volatile elements near the roof of the magma chamber ingibited or delayed the precipitation of primary apatite in the UBS If the Skaergaard differentiation Is modeler assuming primary apatite crystallization In the upper par of the LS where abundant modal apatite is present, and only late stage crystallization of apatite In the UBS where apatite Is less abundant, rare earth elements abundances follow a closed system variation trend. These results rule but any differentiation model for the Skaergaard Intrusion that Includesvolumetrically significant injections or discharges of magma Into or out of the chamber during the final 20% of the crystallization history.

  • PDF

Evaluation of Combined Vertical and Horizontal Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment (직렬연결 수직 및 수평 흐름 갈대 제올라이트 인공습지에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.51-59
    • /
    • 2014
  • A sewage was treated using serially combined vertical and horizontal flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of 314 $L/m^2{\cdot}day$. The reed bed depth was 100cm and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite ; 0.5~1mm and 1~3mm in diameter. pH value decreased in vertical bed, while it increased in horizontal bed. But DO concentration in the effluent of both beds was higher than that in the influent. Average removal efficiencies of the entire treatment system were 99.22% SS, 95.56% BOD, 91.02% $COD_{Cr}$, 87.78% $COD_{Mn}$, 45.87% T-N, 99.88% $NH{_4}^+-N$ and 71.17% T-P. Most of T-N in the effluent was $NO{_3}^--N$. However, the concentration of $NO{_2}^--N$ in the effluent was lower than 0.04 mg/L. All removal efficiencies did not show a remarkable seasonal change.

Effect of Highly Concentrated Turbid Water on the Water Quality and Periphytic Diatom Community in Artificial Channel (인공수로에서 고농도 탁수가 수질 및 부착 규조류 군집에 미치는 영향)

  • Yoon, Sung-Ae;You, Kyung-A;Park, Ji-Hyoung;Kim, Baik-Ho;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.1
    • /
    • pp.75-84
    • /
    • 2011
  • We examined the effect of the turbid water on the periphytic diatom community in an artificial stream system. The artificial stream was constructed with transparent acryl and composed of four channels. Each channel ($20\;cm{\times}200\;cm{\times}40\;cm$) was supplied continuously with eutrophic lake water. In order to the freely colonize and grow diatoms, artificial substrate was installed with commercial slide glass soaked in 1% agar. Prior to introducing turbid water, the artificial stream was operated with lake water for 6 days to permit the propagation of diatom community on the substrates. The turbid water prepared with sediment sieved with ${\varphi}$ $64\;{\mu}m$ at $2\;g\;L^{-1}$ (final concentration, 300 NTU) was provided daily for 50 minute duration. The experiment was conducted for 7 days with manipulated experimental condition of light ($50{\sim}80\;{\mu}mol\;m^{-2}s^{-1}$, light:dark=24:0), temperature ($10{\pm}1^{\circ}C$), and flow rate ($0.31\;cm\;s^{-1}$). Sampling and analysis were conducted daily for water quality and diatom. Turbidity of the water varied 162.2~173.2 NTU during the experiment. After introduction of turbid water, DO, pH and TN were decreased, while SS and TP increased significantly. A total of 14 genera and 47 species of diatoms was observed on the artificial substrates during the experimental period. Of these, Navicula appeared to be a most dominant genus with 10 species, followed by Cymbella (6 species), Fragilaria (6 species) and Gomphonema (5 species). Achnanthes minutissima was the most dominant species (>70% of total frequency) in both control and treatment experiments. Increase in diatom abundance lasted for three days since turbid water introduction, after that they gradually decreased by the termination of the experiment. These results suggest that frequent supply of highly-concentrated turbid water significantly decreases the periphytic diatom community, and retard the recovery of the stable food-web within the stream.