바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구 (Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System)

  • 안병천;송재엽;이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

지역냉난방 시스템

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • 통권40호
    • /
    • pp.84-95
    • /
    • 1993
  • 지역난방은 한 곳에 집중된 대규모 열원시설에서 경제적으로 생산된 열을 일정한 지역내 아파트, 빌딩, 공공 시설 등에 난방 및 냉방용으로 공급하는 도시 기반시설이다. 또한 지역난방은 개별난방이나 중앙난방의 간헐 난방방식과는 달리 24 시간 연속난방을 하므로써 건강하고 쾌적한 실내온도를 유지시켜 주며, 노후된 보일러 교체비 및 유지 보수가 들지 않고, 난방순환펌프 등 각종 부대시설의 축소로 동력비를 절감할 수 있으며 기존 보일러실을 주민복지 공간으로 활용할 수 있고, 연료탱크와 보조난방기구 등이 필요 없어 재해 발생의 우려가 없다. 본지에서는 한국지역난방공사에서 제공한 자료와 월간 설비기술에 게재된 내용을 요약 정리하여 게재한다.

  • PDF

자동제어시리즈 (3) - 중앙난방에서 시간표와 On/Off 제어 방식의 비교

  • 김영일
    • 월간 기계설비
    • /
    • 통권229호
    • /
    • pp.64-70
    • /
    • 2009
  • 본지는 자동제어설비협의회(위원장 최전남) 제공으로 지난 6월호부터 자동제어시리즈를 게재하고 있다. 이번 호에는 중앙난방 제어 방식으로 김영일 서울산업대학교 교수의 '중앙난방에서 시간표와 On/Off 제어 방식의 비교'를 게재한다. 중앙난방 제어 방식에 대해 기존 시간표에 의한 간헐 난방과 제어 방식 중 가장 간단한 on/off 제어를 실내 온도 변화와 에너지 소비량 실험 및 시뮬레이션 기법을 통한 분석한 결과 간단한 제어 방식이라도 적용할 경우 비적용시보다 쾌적성과 에너지 절약 측면에서 유리한 것으로 나타났다.

  • PDF

간헐난방주택에 대한 외기온도 예측제어 적용 연구 (Application of the Outdoor Air Temperature Prediction Control for Intermittent Heating Residences)

  • 태춘섭;조성환;이충구
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.682-691
    • /
    • 2001
  • Most of radiant floor heating systems are operated in the intermittent heating mode in Korea. The application possibility of predictive suboptimal control for Koran residential house was investigated by computer simulation and experiment. For this study, TRNSYS program was used and an experimental facility consisting of tow rooms ($3\times4.4\times2.8 m$) identical in construction was built. The facility enabled simultaneous comparison of two different control method. And real multi residential hose was investigated. Results showed that outdoor air temperature prediction control was superior to the conventional control for radiant floor heating system operated in the intermittent heating mode. New control system resulted in good thermal environment and les energy consumption.

  • PDF

공동주택 간헐난방시스템의 에너지 절감 및 열환경 개선방안 연구 (Strategy of Energy Saving and Thermal Environment Improvement for Intermittent Heating System in Apartment Buildings)

  • 안병천;이태원
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.88-93
    • /
    • 2005
  • In this study, the operational characteristics on heating performance and energy consumption for intermittent hot water heating system in apartment buildings were research by simulation. The effects of apartment inlet hot water temperature and operation time per day on energy consumption and indoor thermal environment are investigated. The strategy of energy saving and thermal environment improvement is suggested in comparison with the existing ones.

주거용건물의 바닥복사 난방방식에 대한 실태조사 연구 (Research on the actual condition of 'Under Floor Radiant Heating for Apartment Housing')

  • 우병관;이성;김삼열
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.81-86
    • /
    • 2007
  • The research analyzes the arrangement of boiler and hot water header, the method of radiator pipe setting, hot water supply control, hourly heating situation of each room for underfloor radiant heating systems in Korea and suggests an alternative to improve to efficient heating method. One of the best options for install position of hot water distributor is under kitchen sink which is center point of all rooms, according to previous research of the energy saving strategies. When the radiator pipes are arranged to each individual room instead of bedrooms through livingroom and kitchen, it has energy saving effects. For rooms without occupancy according to a time period, hot water supply method should be intermittent heating rather than continuous heating. For this intermittent heating method, individual control of hot water supply is more practical, and it can lead to massive energy savings. The intermittent heating system has time-lag, so it is more effective in energy saving with mild and comfort condition if the spaces are preheated by automatic control equipment prior to required time.

공동주택용 온수난방 시스템의 에너지해석 및 제어특성 (The Energy Analysis and Control Characteristics of a Hot Water Heating System for Apartment Houses)

  • 장효환;안병천
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.76-87
    • /
    • 1996
  • Energy analysis for the hot water heating control system of apartment house complex is accomplished by computer simulation. Mathematical model of a boiler, pipe network and a unit-house is developed. The effects of heating control methods on the heating performance and energy consumption of the system are investigated. The heating control methods considered in this study are a continuous heating control, and on-off heating control and an intermittent heating control methods. For each control method, the effects of an outdoor temperature, indoor temperature sensing position and the capacities of the boilers and circulating pumps on the heating performance and energy consumption are obtained and "the best" control method is recommended.commended.

  • PDF

이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성 (Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse)

  • 이현우;심상연;김영식
    • 생물환경조절학회지
    • /
    • 제21권1호
    • /
    • pp.1-11
    • /
    • 2012
  • 관행 이중피복온실과 공기주입 이중피복온실에 대하여 보온, 난방, 환기, 냉방 등 환경조절에 따른 온실내부의 환경변화를 연중 측정하여 온습도 및 광환경 분포특성을 비교분석함으로서 기존 온실의 환경을 개선할 수 있는 방안을 제시하기 위해 수행한 연구결과를 요약하면 다음과 같다. 겨울철 야간에 난방시 공기주입온실과 관행온실의 커튼과 피복재 사이의 온도는 거의 비슷한 값을 보여주고 있어 보온효과는 거의 동일한 것으로 나타났다. 온실내부의 커튼 안쪽의 습도는 난방으로 인해 외부습도보다 낮게 유지되었으나 커튼과 피복재 사이의 습도는 거의 100%로 유지되었다. 주간의 우천시에도 두 가지 온실의 내부온도가 거의 비슷하여 보온효과는 동일한 것으로 나타났다. 주간에 천창환기시 두 온실 모두 일사로 인해 상하방향으로 온도의 편차가 크게 발생하였고, 공기주입온실이 관행온실에 비해 온도가 약간 더 낮기 때문에 환기효과가 더 우수한 것으로 판단된다. 온도분포와 마찬가지로 상하방향으로 습도편차가 크게 발생하였으며, 공기주입온실이 관행온실에 비해 습도가 약간 더 높게 나타나 환기효과가 더 우수한 것으로 판단된다. 야간에 천창환기시에는 두 온실 모두 주간과는 달리 일사가 없기 때문에 온실내부 전체적으로 균일한 온습도분포를 보여주고 있다. 간헐적 포그분사 냉방을 실시하였을 때 두 온실 모두 상하좌우로 비교적 균일한 온습도분포를 보여주었다. 연속 포그분사 냉방을 실시한 경우 전체적으로 균일한 온습도 분포를 보여주었으며, 평균 약 $3.5^{\circ}C$ 정도의 냉방효과가 있는 것으로 나타났다. 커튼과 지붕피복재 사이의 공간에 대한 상대습도와 절대습도의 변화를 분석한 결과 거의 커튼을 닫는 시점에서 피복재의 온도가 노점 온도 이하로 낮아지기 시작하기 때문에 커튼을 닫음과 동시에 제습기를 사용하여 지붕과 커튼 사이 공간의 공기에 함유된 수증기를 제거하면 지붕의 피복재에 발생하는 결로를 억제할 수 있을 것으로 판단된다. 피복재의 사용기간이 경과함에 따라 공기주입온실에 비해 관행온실이 광투과율이 더 감소하는 것으로 나타났다. 이는 온실내부 피복재를 권취식으로 개폐하는 과정에서 먼지와 결로로 인해 오염되기 때문인 것으로 판단된다. 따라서 피복재의 광투과율이 감소되는 것을 방지하기 위해서는 피복재의 권취식 개폐방식을 지양하는 것이 바람직할 것으로 판단된다. 결론적으로 온실의 이중피복 방법을 공기주입 이중피복형태로 하고 천창을 용마루 위치에 나비형태로 설치한다면 관행 이중피복 온실과 동일한 에너지절감효과를 유지하면서 광투과율을 현저히 개선할 수 있고 환기효율도 높일 수 있을 것으로 판단된다.

축분액비의 고액분리에 있어서 분리막의 투과특성 (Characteristics of Membrane Permeability on the Separation of Solid in a Liquid Livestock Manure)

  • 황명구;차기철;이명규
    • 한국축산시설환경학회지
    • /
    • 제6권3호
    • /
    • pp.175-184
    • /
    • 2000
  • Lab-scale의 실험을 통하여 축산폐수의 액비화에 있어서 막 분리 기술의 도입에 따른 막 오염 특성과 투과특성에 대해 살펴본 결과 다음과 같은 결론을 얻을 수 있었다. 1. System의 안정적 운전을 위해서는 낮은 투과유속에서의 운전이 효과적이라 사료되며, Tmax가 지수 함수적으로 투과유속에 대해 감소하였다. 이를 통해서 예측식을 수립하여 운전에 있어서의 막 세정 시기를 결정할 수 있을 것으로 사료된다. 2. 전반적인 막 자체에 대한 순수투과저항을 관찰해본 결과 막 오염은 비가역적 영역보다는 가역적 영역에 의해 이루어진다고 사료된다. 3. 투과유속이 낮을 경우 막면 부착물에 의한 여과저항의 상승이 막 오염의 주된 원인이 되는 반면, 투과유속이 증가할수록 농도분극현상이 막 오염의 주된 원인이 된다고 사료된다. 따라서 높은 투과유속에서의 운전을 위해서는 이러한 농도 분극현상을 최소화 하기 위해서는 이러한 농도 분극현상을 최소화 하기 위하여 높은 전단응력을 제공하거나 막표면에 물리적 충격을 주어 농도 분극현상을 제어하는 방법이 추가되어야 할 것이라 사료된다. 4. 중력여과 및 간헐여과를 통한 막 분리 특성을 살펴본 결과 중력여과의 경우 별도의 흡입압력을 부여하지 않고 단지 수위차에 의해 생성되는 위치에너지에 의한 여과에서도 1.7LMH에서 약 3.5일간 안정되게 유지된 것을 확인할 수 있었으며, 간헐여과를 통해 농도 분극현상을 감소시킴으로 해서 연속여과보다 안정된 운전이 이루어졌다. 종합적으로 고찰해 봤을 때, 축산폐수의 액비화에 있어서 막 분리 기술의 도입은 그 유출수의 성상에 있어서 원수의 성상에 상관없이 일정한 질을 보이고 있음을 확인할 수 있었고, 공정의 안정적 유지를 위해서는 낮은 투과유속의 흡입과 정지의 간격이 비교적 긴 간헐여과 방식이 적합하다고 사료되며, 높이차를 이용한 중력여과 또한 추가적인 연구가 진행된다면 동력의 소모면에서 이점이 있을 것이라 사료된다.기는 축사의 난방 보조열원으로서 양호한 열효율을 나타내어 우리나라 축사시설에 적용가능성을 제시하였다. 본 지열교환기 시스템은 지열을 이용하는 환경보전형 에너지 시스템으로서 시설하기 간편하고 경제적이며 반영구적인 냉난방 및 환기시스템이다. 따라서, 우리나라 축산시설에 실용화될 경우에 우수한 대체에너지원으로 에너지 절감효과에도 크게 기여하리라고 전망된다.ble amount of acid mucin, Most of the medium sized and small mucous cells contained neutral mucin and sialomucin, but a few mucous cells contained neutral mucin and strongly sulfomucin or neutral combined with strongly sulfomucin and sialomucin. Most of the esophageal mucous cells pf Bryzoichthys lysimus contained small amount of neutral mucin, while on the other hand a feww mucous cells contained small amount of neutral mucin and minimal amount of sialomucin. But the esophageal mucous cells of Takifugu pardalis contained considerable amount of neutral mucin only.분해가 더욱 촉진되었으며, 30℃에서 교반 처리를 행한 경우가 10℃에서 교반 처리를 행한 경우 보다 지방분해가 더욱 촉진되었다. 산양유 원유는 30℃에서 교반 처리 시간이 연장되어도 지방분해는 뚜렷한 증가를 나타내지 않았다.와 표준체중군 여자에게서 가장 높게 나타났다. 5. 남자의 53.9%, 여자의 83.2%가 체중 조절에 관심이 있다