• Title/Summary/Keyword: 간접광

Search Result 114, Processing Time 0.03 seconds

An Enhancement Technique for Separation of Direct Light and Global Light Using High Frequency Illumination pattern (고주파 조명패턴을 사용한 직접광과 간접광의 분리성능 향상 기법)

  • Jo, Mi-Ri-Na;Park, Dong-Gyu
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1262-1272
    • /
    • 2009
  • In computer graphics, there exist many studies about illumination and radiance for a realistic description of the 3D modeling and rendering. When we see a scene, the scene is lit by a source of light and the radiance of the points by a source in the scene. The radiance has direct light and glight component. The direct light gets lights directly from light source, but the global light gets lights indirectly by interreflections among complicated geometrical components. In this paper, we studied a method for increasing the accuracy of separating direct light and global light components from a scene by using high frequency illumination pattern. For experiments, we applied the separating method of Nayar's and found the best configurations for the separation through the experiments. We improved the separation accuracy of direct and global light by measuring the value of unilluminated area, which depends on the characteristics of object. Furthermore, we enhanced invisible scene of the global light by applying the image filtering technique.

  • PDF

VLC Channel Model Considering Indirect Light (간접 조명 환경 실내 가시광 통신의 채널 모델)

  • Lee, Jung-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.8
    • /
    • pp.706-712
    • /
    • 2013
  • In this paper, channel modeling of VLC(Visible Light Communication) was investigated under indirect lightning circumstance which was the way that all phontons started from LED(Light Emitting Diode) were reached on the floor with NLOS paths. I supposed width(6m), depth(4m), height(2.2m) cube room circumstance for VLC communication channel and supposed that 4 LEDs were located at 2m height, which emitted photons at the direction of wall and ceiling. Channel characteristics, which were power attenuation and delayed receiving of light signal, were abstracted from receivers(PDs) which were located at 0.5m above from floor. The availability of channel was verified via BPSK based communication simulation.

Status of Light Environment in Greenhouses (온실의 광환경 실태 조사 분석)

  • 이석건;김문기
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.11a
    • /
    • pp.14-19
    • /
    • 1997
  • 식물의 광반응은 광질과 광강도에 따라 상이하며, 광은 열을 동반하게 되므로 광만을 분리하여 생각할 수 없다. 즉, 광은 식물체의 체온과 엽온을 높이고, 잎의 수증기 장력을 증가시켜 증산을 촉진하므로 기화열을 발생하는 원동력이 되기도 한다. 따라서 광은 잎속의 수분이나 기공개도 등에 영향을 주기 때문에 광합성속도에 간접적인 영향을 미치기도 한다. (중략)

  • PDF

High speed 3D position detection of radiation using CCD camera (CCD 카메라를 이용한 방사선원 3차원 위치 고속 측정기)

  • Lee, Nam-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.433-435
    • /
    • 2005
  • 광변환 물질을 사용하여 X-선이나 감마방사선을 가시광으로 변환한 다음 CCD 카메라를 통하여 광량을 측정하면 방사선의 양을 간접적으로 측정할 수 있다. 본 연구에서는 CCD형 비상대용 로봇용 고속 삼차원 방사선 위치 탐지장치에서 방사선 위치 센싱의 핵심 역할을 수행하는 CCD 방사선 탐지부를 간접 방사선 측정 방법을 응용하여 고안하고 구현한 다음 이에 대한 방사선 특성시험을 수행하였다. 시험 결과로 부터 구현한 CCD형 방사선 센서가 방사선 위치 및 선량 탐지장치로 활용 가능성이 충분함 확인하였다.

  • PDF

Impact of Solar Irradiance on the Receiver Sensitivity of Free-Space Optical Communication Systems (주광이 무선 광통신 시스템의 수신 감도에 미치는 영향)

  • Park, Gihong;Kim, Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.259-267
    • /
    • 2020
  • We evaluate the degradation of receiver sensitivity induced by direct and indirect exposure to solar irradiance in free-space optical communication systems. For this purpose, we calculate the variances of numerous noise components arising from solar irradiance, and then estimate the receiver sensitivity penalties for intensity-modulation/direct-detection and coherent systems. The results show that the penalties are less than 1.3 dB when indirect sunlight impinges on the detector, regardless of the system. However, the sensitivity penalties are estimated to be larger than 30 dB when the sunlight is directly incident upon the receiver. These penalties are barely reduced if we insert an optical polarizer, or if we adjust the bandwidth of an optical filter at the receiver to be as narrow as the signal's bandwidth.

A Studies on Indirect Photometric Detection of Aliphatic Compounds by High-Performance Liquid Chromatography (고성능 액체 크로마토그래피에 의한 지방족 화합물의 간접 분광광도 측정에 관한 연구)

  • Sam-Woo Kang;Jeon-Tag Kang
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.406-412
    • /
    • 1989
  • Indirect photometric detection of aliphatic compounds such as alcohols, ketones and esters was investigated in high-performance liquid chromatography, These samples possessing nonchromophore or weak chromophore could be indirectly detected by a UV detector with addition of UV absorbing, p-chlorophenol or p-nitrophenol in mobile phase as detection reagent, and submicrogram detection limits were achieved. Some mixtures of samples were also able to be separated and quantitated with good resolution and comparatively high sensitivity under optimum conditions.

  • PDF

SHEAR BOND STRENGTH AND FAILURE PATTERNS ACCORDING TO THE MATERIAL OF RESIN BASE IN INDIRECT BRACKET BONDING (브라켓 간접부착시 레진 베이스의 재료에 따른 전단결합강도와 파절양상 비교)

  • Jeon, Man-Bae;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.277-284
    • /
    • 1998
  • The purpose of this study was to evaluate the propriety of making use of the light-cured resin base in indirect bracket bonding technique by study of shear bond strength and failure patterns according to the material of resin base. Metal brackets were bonded to the stone models of specimens involving bovine lower incisor with chemical-cured(Excel), light-cured(Light-Bond) and thermal-cured(Therma-Cure) resin. They were transferred to the specimens and bonded using sealant. The shear bond strength was tested on Instron. After bracket removal, the bracket base was examined and assessed with the adhesive remnant index(ARI). The results were as follows : 1. No significant differences in shear bond strength were found among the three groups (P>0.05). 2. No significant differences in ARI score were found among the three groups (P>0.05). The above results suggest that light-cured resin base in addition to chemical-cured and thermal-cured resin bases is useful in the indirect bonding technique.

  • PDF

Evaluation of mechanical properties of several dual-cure resin cements by curing modes (중합방법에 따른 여러 이중중합 레진 시멘트의 기계적 성질 평가)

  • Kim, Soo-Yeon;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the mechanical properties of several dual-cure cements by different curing modes. Materials and Methods: One resin-modified glass ionomer cement (FujiCEM 2), two conventional dual-cure resin cements (RelyX ARC, Multilink N), and two dual-cure self-adhesive resin cements (RelyX U200, G-CEM LinkAce) were used. To evaluate the influence of the curing methods, each cements divided into four conditions (n = 20); Condition 1: self-curing for 10 minutes, Condition 2: immediate after 20 seconds light-curing, Condition 3: 24 hours after self-curing, Condition 4: 24 hours after light-curing. The compressive strength and diametral tensile strength were measured with a universal testing machine. All data were statistically analyzed using t-test, one-way ANOVA and Scheffe's test. Results: The results showed the compressive strength and diametral tensile strength after 24 hours in all curing modes were higher than immediate except RelyX ARC light-cured and Multilink N light-cured. The FujiCEM 2 showed lowest values (P < 0.05). Conclusion: The outcome was cement-depend, but there is no significant difference about compressive strength and diametral tensile strength between dual-cure self-adhesive resin cements and conventional resin cements. And this result will be used as a base line data selecting resin cement for favorable long-term prognosis.

Liquid Chromatography of Non-Chromophores by Indirectly Photometric Detection (간접 분광광도 측정에 의한 비발색단의 액체크로마토그래피)

  • Sam-Woo Kang;Hae-Beom Oh;Young-Ja Moon
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.184-189
    • /
    • 1987
  • Brilliant green was examined as a detection reagent in the separation of some aliphatic alcohols, ketones and esters by the reverse-phase liquid chromatography. These samples not possessing chromophore could be indirectly detected by photometric detector with the assistance of brilliant green in visible range (625nm). Some mixtures of samples were also able to separated and detected with good base line resolution and comparatively high sensitivity.

  • PDF

Development of an High Speed Detector System for Radiation (방사선원 검출용 고속 탐지기 개발)

  • Lee, Seung-Min;Lee, Hyo-Sung;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.121-123
    • /
    • 2007
  • 광변환 물질을 사용하여 X-선이나 감마방사선을 가시 광으로 변환한 다음 CCD 카메라를 통하여 광량을 측정하면 방사선의 양을 간접적으로 측정할 수 있다. 본 연구에서는 CCD형 비상대응 로봇용 고속 삼차원 방사선 위치 탐지장치에서 방사선 위치 센싱의 핵심 역할을 수행하는 CCD 방사선 탐지부를 간접 방사선 측정 방법을 응용하여 고안하고 구현한 다음 이에 대한 방사선 특성시험 및 거리측정을 수행하였다. 시험 결과로부터 구현한 CCD형 방사선 센서가 방사선 위치 및 선량 탐지장치로 활용 가능성이 충분함 확인하였다.

  • PDF