• Title/Summary/Keyword: 각막정점

Search Result 8, Processing Time 0.028 seconds

Mathematical Expression of the Toric Cornea using Corneal Topography Measurements (각막지형도(topography) 각막곡률로부터 토릭 각막형상의 수식화)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.439-444
    • /
    • 2011
  • Purpose: To represent the shape of toric corea in the elliptical function for the determination of curvature distribution and lacrimal thickness between cornea and contact lens when the lens is fitted. Methods: Topography measurements of corneal curvature and curvature equation derived from the assumed elliptical function were evaluated using the Excel program which included the necessary equation derived. Results: Mathematical expressions for the cornea whose ribbon shaped-topography image, in which the center does not coincide with the corneal apex, can be determined. Conclusions: For the application where the higher accuracy on the cornea is not required, such as higher order aberration, the cornea cal be expressed in the simple elliptical function.

Validating a New Approach to Quantify Posterior Corneal Curvature in Vivo (각막 후면 지형 측정을 위한 새로운 방법의 신뢰도 분석 및 평가)

  • Yoon, Jeong Ho;Avudainayagam, Kodikullam;Avudainayagam, Chitralekha;Swarbrick, Helen A.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.223-232
    • /
    • 2012
  • Purpose: Validating a new research method to determine posterior corneal curvature and asphericity(Q) in vivo, based on measurements of anterior corneal topography and corneal thickness. Methods: Anterior corneal topographic data, derived from the Medmont E300 corneal topographer, and total corneal thickness data measured along the horizontal corneal meridian using the Holden-Payor optical pachometer, were used to calculate the anterior and posterior corneal apical radii of curvature and Q. To calculate accurate total corneal thickness the local radius of anterior corneal curvature, and an exact solution for the relationship between real and apparent thickness were taken into consideration. This method differs from previous approach. An elliptical curve for anterior and posterior cornea were calculated by using best fit algorism of the anterior corneal topographic data and derived coordinates of the posterior cornea respectively. For validation of the calculations of the posterior corneal topography, ten polymethyl methacrylate (PMMA) lenses and right eyes of five adult subjects were examined. Results: The mean absolute accuracy (${\pm}$standard deviation(SD)) of calculated posterior apical radius and Q of ten PMMA lenses was $0.053{\pm}0.044mm$ (95% confidence interval (CI) -0.033 to 0.139), and $0.10{\pm}0.10$ (95% CI -0.10 to 0.31) respectively. The mean absolute repeatability coefficient (${\pm}SD$) of the calculated posterior apical radius and Q of five human eyes was $0.07{\pm}0.06mm$ (95% CI -0.05 to 0.19) and $0.09{\pm}0.07$ (95% CI -0.05 to 0.23), respectively. Conclusions: The result shows that acceptable accuracy in calculations of posterior apical radius and Q was achieved. This new method shows promise for application to the living human cornea.

The Analysis of Corneal Patterns in Korean 20s by Corneal Topography and Corneal Radii by Astigmatic Degree (각막지형도를 이용한 20대의 각막형상 및 난시도에 따른 각막곡률반경의 분석)

  • Kim, So Ra;Gil, Ji-Yeon;Park, Chang Won;Kim, Ji Hye;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.273-281
    • /
    • 2011
  • Purpose: In order to provide the fundamental information for the design development of RGP lenses and its clinical prescription, the corneal types of Korean twenties were analyzed according to corneal shapes, astigmatic degree, and the certain distance from the corneal apex. Methods: Corneal types of total 252 eyes in 20s were firstly classified, then their corneal radii from the certain distance from the corneal apex were measured by corneal topography and further analyzed based on the astigmatic degree. Results: Korean 20s' corneal types were classified as 14.3%(36 eyes) of round, 31.3%(79 eyes) of oval, 28.6%(72 eyes) of symmetric bow tie, 17.5%(44 eyes) of asymmetric bow tie, 8.3%(21 eyes) of irregular shapes. The round and oval typed corneas had mild astigmatic degree whereas the higher astigmatic degree in symmetric and asymmetric bow tie typed corneas were shown. The relative corneal radii of round and oval typed corneas at each distance from corneal apex were shown to consistently increase regardless of astigmatic degrees when they measured at certain distances from the corneal apex. However, the relative corneal radii of symmetric and asymmetric bow tie typed corneas within 1.0-1.5mm from the corneal apex were decreased, which showed steeper slope than it within 1.0 mm and somewhat different based on astigmatic degrees. Bigger change of corneal radii outer 3.5 mm from the corneal apex in symmetric bow tie typed corneas with astigmatism of 1.50-2.00 D and 2.25-2.75 D appeared. Conclusions: The consideration of radial change from the central cornea to peripheral cornea is necessary for manufacturing RGP lens and its prescription since they showed different change in corneal radii by corneal patterns and astigmatic degrees.

Comparison of Corneal Asphericity with Measuring Range (측정 범위에 따른 각막비구면계수의 비교)

  • Jeon, In-Chul;Jeong, Woo-Jae;Kang, Ji-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.469-476
    • /
    • 2012
  • Purpose: The purpose of this study is to investigate the changes of asphericity according to diameter and direction of the cornea. Methods: The changes of asphericity according to diameter and direction of cornea is measured by using Pentacam(Oculus Co., Germany), as targeting 57 adults (average $27.0{\pm}4.8$, 20 men, 37 women) without any ophthalmic diseases, which may be effective in eyesight, and refractive surgery. Results: As diameter increases in every direction based on the corneal vertex, asphericity has attentively increased (p<0.05), and the size of asphericity in each direction from every measured diameter showed as superior > nasal > inferior > temporal. In group comparison by nearsightness and astigmatism level, asphericity measured high when nearsightness and astigmatism levels were higher, and this appears to be statistically attentive.(p<0.05). Conclusions: Asphericity of cornea significantly increased according to increase of diameter of cornea, and as measured figure or increased quantity appeared differently in all directions based on corneal vertex, so it helps to understand shape of cornea, and considered that is the part to be considered during manufacturing and fitting of RGP lenses.

The Change in Corneal Eccentricity on the Correction of Refractive Error using Reverse Geometry Lens (역기하렌즈(Reverse Geometry Lens)의 굴절교정시 각막 편심률(Eccentricity)의 변화)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Purpose: In this study we investigated the correlation between the effect of myopia correction and the change of corneal eccentricity using reverse geometry lens. Methods: The 23 students (46 eyes) continuously wearing reverse geometry lens during 3 months were divided into Group I and Group II by different parameter fitting methods of wearing Reverse Geometry Lens. We measured a corneal eccentricity for Group I and Group II at $10^{\circ}$, $20^{\circ}$, and $30^{\circ}$ positions from corneal apex before wearing reverse geometry lens, 1 week, 1 month, and 3 months after wearing reverse geometry lens. We also measured an uncorrected visual acuity, a spherical equivalent, and a corneal radius and analyzed the correlation between them and the change of corneal eccentricity using statistical significance test. Results: There were the statistical significances of a change of corneal eccentricity (p=0.03, t=-2.29) for Group I and Group II at 10 position from corneal apex in a week after wearing reverse geometry lens, but were not those (p>0.05) in 1 month, and 3 months after wearing reverse geometry lens. There were the statistical significances of correlation between the change of corneal eccentricity and a corrected visual acuity, and a corneal radius, respectively. Particularly, the high correlation between the change of corneal eccentricity and a corrected visual acuity (r=-0.36, p=0.00, t=6.5), and a spherical equivalent (r=-0.72, p=0.00, t=-70.5) for Group II in a week after wearing reverse geometry lens showed. Conclusions: We knew from these results that the high correlation between the effect of myopia correction and the change of corneal eccentricity in a week after wearing reverse geometry lens represented.

The Investigation and Development of Astigmatism Correction Treatments by Finite Element Method and Animal Experiments (유한요소법과 동물실험을 통한 난시교정술의 고찰 및 개발)

  • Sin, Jeong-Uk;Han, Tae-Won;Kim, Su-Hyang;Kim, Jae-Ho;Lee, Seong-Jae;Park, Hyo-Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.45-51
    • /
    • 1999
  • The purpose of this study is to investigate the effects of various factors in keratotomy for astigmatism correction on surgical outcomes by finite element method as well as animal experiments. Three kinds of surgical techniques were mechanically investigated : arcuate, straight, and inverse arcuate keratotomy. Among the three techniques the arcuate keratotomy is the most popular one while the other two techniques are being investigated in this area. The arcuate keratotomy was found to be more controllable and effective in reducing the refractive power than the others. In arcuate keratotomy it was found most effective when the incision was located in the middle position between the apex and the edge of the cornea from the results of experiment as well as finite element study. Regarding to the range of the corneal incision in arcuate keratotomy, the incision angle of 90$^{\circ}$ was found th be most effective in reducing refractive power than other angles even it was incised up to 150$^{\circ}$. Therefore, it was concluded that 90$^{\circ}$ of incision angle results in the largest decrease in refractive power in arcuate keratotomy. However, other important findings were that the effect of the surgery decreased with time so the visco-effect of the cornea and auto-healing process. Therefore, these factors should be considered in future studies.

  • PDF

Mathematical Expression of Eye Movement Using Rotation Matrix (Rotation Matrix를 이용한 안구운동의 수학적 표현)

  • Kim, YongGeun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.51-55
    • /
    • 1999
  • The eye movement of the eyeball's center of a rotation can represent with the rotation matrix $R_x$, $R_y$, $R_z$ due to a coordinate axis rotation transformation of Cartesian coordinate, and describes of an abduction, an adduction, an elevation, a depression, an intorsion, an extorsion in principle rotation six forms of the eye. The eye movement from primary eye position to tertiary eye position could be composed with the rotation matrix combination, and by the primary rotation of six and the secondary rotation of eight, could be represented with the extrocular muscle of six. The position of the cornea vertex point or pupil point due to the eye movement can describe to transform the rotation matrix of the cartesian coordinate to spherical coordinate$(r,{\theta},{\phi})$.

  • PDF

The adsorption pattern of protein to the soft contact lens and its effect on the visible light transmission and the contact angle (소프트콘택트렌즈의 단백질 부착 양상 및 가시광선투과도와 접촉각에 미치는 영향)

  • Park, Mijung;Kwon, Mi Jeong;Lee, Sun Hee;Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.53-68
    • /
    • 2004
  • Protein deposit buildup on soft contact lenses(SCLs) is responsible for discomfort, optical defects and is even damaging to the eye. To better understand protein deposit formation on SCL, we investigated the pattern of protein attachment on patient-worn SCLs and the effect of the protein on the contact angle of SCLs and the transmission of visible light. This study used data from a clinical trial where subjects wore either daily-wear SCL(etafilcon A, N=40) for various period up to 14 days, or extended-wear SCL(balafilcon A, N=40) for 8 h day or night. The adsorption of protein in daily-wear SCLs was significantly increased in patient-worn time-dependent manner although the lenses were cleaned everyday by using the multi-purpose SCL solution. After 2 weeks wearing, the protein on the SCL influenced the contact angle of the lenses. Furthermore, the transmission of visible light of the lenses decreased up to almost 7%. Extended-wear SCLs worn during the closed eye condition were found to deposit significantly more protein than SCLs worn during the open eye condition. The amounts of protein adsorbed both after daily SCL wear and after overnight SCL wear were not affected the contact angle and the transmission of visible light of the lenses. The protein deposit buildup on SCL related to the corneal temperature and pH of tear fluid.

  • PDF