• Title/Summary/Keyword: 가정용 열병합

Search Result 29, Processing Time 0.03 seconds

A simulation study on residential fuel cell system for cost curtailment (가정용 연료전지 시스템 대상 시뮬레이션 기반 비용절감 기법 연구)

  • Hwang, Su-Young;Kim, Min-Jin;Lee, Jin-Ho;Lee, Won-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3148-3153
    • /
    • 2008
  • Residential fuel cell cogeneration systems have gained much interest due to its high efficiency. In this study, we have performed numerical simulation of residential fuel cell cogeneration system which includes a fuel cell/grid hybrid system. The cogeneration system consists of 1kW PEFC, cooling system, inverter/converter and reformer. Several empirical models have been employed for respective components to improve the accuracy of the simulations. The load varies seasonally. The present simulations can successfully predict the characteristics of the hybrid cogeneration system and thus it can be utilized for establishing an optimal operating strategy of the system.

  • PDF

Development and Performance Test of SOFC Co-generation System for RPG (SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Choi, Ho-Yun;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

Performance Measurements of A Stirling Engine for Household Micro Combined Heat and Power with Heat Source Temperatures and Cooling Flow Rates (가정용 열병합 발전을 위한 스털링 엔진의 열원 온도 및 냉각수 유량에 따른 성능 실험)

  • Sim, Kyuho;Kim, Mingi;Lee, Yoon-Pyo;Jang, Seon-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • A Beta-type Stirling engine is developed and tested on the operation stability and cycle performance. The flow rate for cooling water ranges from 300 to 1500 ml/min, while the temperature of heat source changes from 300 to $500^{\circ}C$. The internal pressure, working temperatures, and operation speed are measured and the engine performance is estimated from them. In the experiment, the rise in the temperature of heat source reduces internal pressure but increases operation speed, and overall, enhances the power output. The faster coolant flow rate contributes to the high temperature limit for stable operation, the cycle efficiency due to the alleviated thermal expansion of power piston, and the heat input to the engine, respectively. The experimental Stirling engine showed the maximum power output of 12.1 W and the cycle efficiency of 3.0 % when the cooling flow is 900 ml/min and the heat source temperature is $500^{\circ}C$.

The Operation Characteristics of Domestic Stirling Engine Cogeneration System (가정용 스털링엔진 열병합발전시스템 운전특성에 관한 연구)

  • Choi, Jae-Joon;Park, Byung-Sik;Jung, Dae-Heon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.309-314
    • /
    • 2009
  • The unpredicted worldwide oil price makes the energy efficiency technology be more importance than any other period. The small cogeneration system is one of the most representative technology among the energy efficiency technologies, and the Stirling engine cogeneration system has been concerned and investigated due to the preferable characteristics - low toxic emission, low noise and vibration level, and the various form of fuel. A tiny, 1kW of electrical output, gas fueled Stirling engine cogeneration system was investigated. The electrical efficiency and thermal efficiency of the system were measured. The experiment was executed at an independent Stirling engine mode, independent secondary burner mode, and the combined mode. Part load characteristics of the Stirling engine cogeneration system were investigated also. With the efficiency characteristics, the $O_2$ and NOx emission characteristics were measured.

  • PDF

Combustion Characteristics of a Premixed Burner in a Stirling Engine for a Domestic Cogeneration System (가정용 열병합 스털링 엔진을 위한 예혼합 버너의 연소 특성)

  • Ahn, Joon;Lee, Youn-Sik;Kim, Hyouck-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.211-216
    • /
    • 2012
  • The availability of thermal energy has been widely recognized recently, and the cascade usage of thermal energy from combustion has been encouraged. Within this framework, a 1-kW-class Stirling-engine.based cogeneration system has been proposed as a unit of a distributed energy system. The capacity has been designed to be adequate for domestic usage, which requires high compactness as well as low emissions and noise. To develop a highly efficient system satisfying these requirements, a premixed slot-type short-flame burner has been proposed, and a series of experiments has been performed to understand its combustion characteristics. Flame images have been captured to observe the dependence of the flame mode on the combustion load and air/fuel ratio. The exhaust gas has been sampled and analyzed to study the emission characteristics for each flame mode.

A Simulation Study of Residential Fuel Cell Cogeneration System Based on Load Energy (부하별 에너지 예측기반 가정용 연료전지 열 병합 시스템 시뮬레이션 연구)

  • Hwang, Su-Young;Kim, Min-Jin;Lee, Jin-Ho;Lee, Won-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.78-81
    • /
    • 2008
  • Residential fuel cell cogeneration systems have gained much interest due to its high efficiency. In the present study, we have performed numerical simulation of residential fuel cell cogeneration system which includes a fuel cell/battery hybrid system. The cogeneration system consists of 1kW PEFC, two 60Ah batteries, inverter/converter and reformer. Several empirical models have been employed for respective components to improve the accuracy of the simulations. The load varies seasonally. The present simulations can successfully predict the characteristics of the hybrid cogeneration system and thus it can be utilized for establishing an optimal operating strategy of the system.

  • PDF

A Simulation based Study on the Economical Operating Strategies for a Residential Fuel Cell System (시뮬레이션 기반 가정용 연료전지 시스템의 경제적 운전전략에 관한 연구)

  • Hwang, Su-Young;Kim, Min-Jin;Lee, Jin-Ho;Lee, Won-Yong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.2
    • /
    • pp.104-115
    • /
    • 2009
  • In case of residential fuel cell system, it is significant to stably supply heat and power to a house with high efficiency and low cost for the successful commercialization. In this paper, the control strategy analysis has been performed to minimize the total cost including capital and operating cost of the residential fuel cell system. The proposed analysis methodology is based on the simulator including the efficiency models as well as the cost data for fuel cell components. The load control strategy is the key factor to decide the system efficiency and thus the cost analysis is performed when the fuel cell system is operated for several different load control logics. Additionally, annual efficiency of the system based on the seasonal load data is calculated since system efficiency is changeable according to the electric and heat demand change. As a result, the hybrid load control combined electricity oriented control and heat oriented control has the most economical operation.

An Economic Feasibility of Household Fuelcell System (가정용 연료전지 시스템의 경제성평가)

  • Ryu, Seunghyun;Kim, Suduk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.138.1-138.1
    • /
    • 2010
  • 정부는 그린홈 100만호 보급 사업에서 연료전지의 보급 목표를 2010년 200대 2011년 300대, 2012년 500대로 결정하였고 이에 따라 2012년까지 누적 보급대수가 1000대에 달할 전망이다. 본 연구에서는 현재 상업화 되어있는 국내업체의 1kW급 가정용 연료전지 시스템을 2009년에 도입되는 것으로 가정하여 경제성평가를 수행하였다. 분석의 편의상 2009년 서울 지역 난방면적 $100m^2$을 기준으로 전제하였고, 대표가정의 전기와 열수요는 CES 소형 열병합 사업 타당성 분석 프로그램(GS파워, 2006)을 활용하여 구했다. 비용의 경우 기존 보일러의 설비가격은 60만원이며 연료전지시스템의 설비가격은 1200만원이다. 다만 연료전지의 고가 소모품인 스택은 2007년 발간된 한국에너지 기술연구원의 신재생에너지 경제성평가 보고서를 인용하여 스택의 수명은 5년, 교체비용은 1000만 원이나 5년마다 30%의 비용 하락을 전제하였다. 또한, 연료전지시스템의 수명을 20년으로 가정하였으며 할인율은 5.5%를 가정하였다. 한편, 가정용 연료전지의 최적 운전방안을 찾기 위해서 기존 설비를 이용한 비용과 전기추종운전, 열추종운전의 시뮬레이션을 수행한 뒤 세가지 결과를 시간대별로 비교함으로써 최적의 시간대별 운전방식을 선택하는 복합추종운전의 비용을 분석하였다. 시뮬레이션결과, 기존 설비 이용 시 에너지 비용은 1,934,864원으로 분석된 반면 연료전지를 이용한 전기추종은 1,123,691원, 열추종은 1,180,425원, 복합추종은 1,121,174원으로 계산되었다. 한편 편익면에서는 복합추종운전시 813,690원의 편익이 발생하는 것으로 분석되었으며 B/C ratio의 결과는 0.405로 현재로서는 연료전지 시스템이 경제성이 없는 것으로 분석되었다. 따라서 정부는 연료전지의 보급목표와 민간 주도의 자생적인 시장형성을 촉진하기 위해서 단순 설치 보조금 이외에 연료전지시스템과 스택의 비용을 획기적으로 저감 시킬 수 있는 기술개발을 촉진하는 정책 병행이 필요해 보인다.

  • PDF

Experimental Investigation on the Optimal Design of Water Tank for Domestic Hot Water Supply using PEMFC Co-generation System (가정용 고분자 전해질 연료전지 열병합 발전시스템의 급탕 적용을 위한 온수 저장조의 최적 설계에 관한 실험적 연구)

  • Hwang, Yu-Jin;Ahn, Young-Chull;Cheong, Seong-Ir;Jin, Keun-Ho;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.394-399
    • /
    • 2008
  • There are many attempts to use a fuel cell system as a residential power generation system. The purpose of this study is to investigate the optimal design of a water tank for a hot water system when the fuel cell co-generation system is combined with a domestic hot water supply system. The demands of hot water supply per month per home are investigated in Busan for a year. It showed somewhat large differences between the actual demand and the designed demand of hot water, but the actual capacity of hourly averaged hot water demands is analyzed as $60{\ell}/h$ in this study based on the actual demand. The experiments are performed in the various inlet and outlet locations of nozzles, and the hot water consumption rates. The experimental results are showed that the optimal capacity of the water tank is $200{\ell}$ when the thermal efficiency, the storing capacity of hot water and the space for installation are considered.

Effects of Novel Fin Shape of High Temperature Heat Exchanger on 1 kW Class Stirling Engine (1kW급 스털링엔진 고온 열교환기의 Fin 형상 개선 효과 분석)

  • Ahn, Joon;Kim, Seok Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.8
    • /
    • pp.545-552
    • /
    • 2017
  • In this research, numerical analysis was carried out on novel and existing fins, adjusted in terms of factors such as length, spacing, and angle, of a high-temperature heat exchanger for a 1 kW class Stirling engine, designed as a prime mover for a domestic cogeneration system. The performance improvement as a result of shape optimization was confirmed with numerical analysis by including the air preheater, which was not considered during optimization. However, a negative heat flux was observed in the cylinder head portion. This phenomenon was clarified by analyzing the exhaust gas and wall surface temperature of the combustion chamber. Furthermore, assuming an ideal cycle, the effects of heat transfer enhancement on the thermodynamic cycle and system performance were predicted.