• Title/Summary/Keyword: 가열패널

Search Result 33, Processing Time 0.059 seconds

Residual gas analysis of small cavity for emissive flat panel display (미소체적을 갖는 평판표시소자용 패널내부의 잔류가스 분석)

  • 조영래;오재열;최정옥;김봉철;이병교;이진호;조경익
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • The total pressure and partial pressure of small cavity for flat panel display have been successfully measured by using an ultra-high vacuum chamber with mass spectrometer. The total pressure in the panel was in the range of $10^{-6}$ Torr and the major partial pressure affecting increase in total pressure were those of Ar, $CH_4$and He. The baking temperature during evacuation process was very important for high-vacuum package, the total pressure and partial pressure of $CH_4$ were decreased as the increase of baking temperature.

  • PDF

Study on the Characteristics of Conduction Heat Transfer According to the Heating Temperature of a Composite Wall in a Light-weight Partition (경량칸막이 복합벽체의 가열온도에 따른 전도 열전달 특성 연구)

  • Park, Sang-Min;Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.60-68
    • /
    • 2019
  • The paper reports the characteristics of conduction heat transfer to the backside part according to the heating temperature of a composite wall in a lightweight partition used for indoor space compartments. Stud partitions, SGP partitions, sandwich panels, urethane foam panels, and glass wool panels. which are generally used as light-weight partition walls, were selected as experiment samples, and the characteristics of conduction heat transfer to the backside part as the top surface were analyzed by applying heating temperatures of $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, and $500^{\circ}C$ to the bottom surface for 1800 s. According to the experimental results, the maximum backside temperatures at the maximum heating temperature of $500^{\circ}C$ was $51.6^{\circ}C$, $63.6^{\circ}C$, $317.2^{\circ}C$, $124.9^{\circ}C$, and $42.2^{\circ}C$ for the stud partition, SGP partition, sandwich panel, urethane foam panel, and glass wool panel, respectively. The maximum conduction heat- transfer rates at $500^{\circ}C$ were 17.16 W, 18.39 W, 136.65 W, 14.34 W, and 5.57 W for the stud partition, SGP partition, sandwich panel, urethane foam, and glass wool panel, respectively.

Thermal Buckling Characteristics for Thermal Protection System Panel Using Ritz Method (리츠 법을 이용한 열방어 시스템 패널의 열 좌굴 특성 연구)

  • Lee, Heesoo;Kim, Yongha;Park, Jungsun
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.1
    • /
    • pp.18-28
    • /
    • 2019
  • High speed vehicles are subjected to high thermal loadings due to aerodynamic heating during ascent and reentry. Since a thermal protection system panel is mechanically constrained, it may cause thermal buckling under excessive thermal loadings. The thermal buckling could disturb the field of flow and make aerodynamic characteristics unstable. It is thus necessary to design the thermal protection system panel to prevent thermal buckling. This study defines the analytical model of temperature distribution using the finite difference method for the thermal protection system panel with large temperature differences inside and outside. This paper proposes the approximate model of the thermal buckling characteristics for the thermal protection system panel through the use of the Ritz method. The validity of the present method was verified by comparing the results of the finite element analysis. Furthermore, this research performs the parametric analysis of the thermal buckling characteristics for the thermal protection system panel by using the approximate model.

Analysis of Temperature Distribution of the Glass Panel in the Infrared Heating Chamber (적외선 가열로에서 가열되는 유리 패널의 온도분포 해석)

  • Lee, Kong-Hoon;Kim, Ook-Joong;Ha, Su-Seok;Kang, Sae-Byul;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.278-283
    • /
    • 2003
  • Analysis has been carried out to investigate the temperature variation and the uniformity of the temperature distribution of the glass panel by infrared radiant heating. Halogen lamps are used to heat the panel and located near the top and bottom of the rectangular chamber. The thermal energy is transfered only by radiation and the radiation exchange occurs only on the solid surfaces and is considered by using the view factor. The results show that the uniformity of the temperature distribution of the panel is improved but the time for heating increases as the wall reflectivity is large. The temperature difference reaches a maximum in the early stage of the heating process and then decreases until it reaches the uniform steady-state value.

  • PDF

Automation System of Explosion-Proof Panel Condition (방폭 패널 컨디션 자동화 시스템(1))

  • Hwang, Dae-Hyeon;Choi, Kwang-Il;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.253-258
    • /
    • 2020
  • Petrochemical industry complex in Korea always has high riskiness due to explosive and inflammable gases. To prevent these explosion, most facility of petrochemical industry complex requires the performance of explosive proof. The control panel, which is used as explosive proof, has been used the air injection method by manually from outside to constantly keep the temperature and pressure between inside and outside of the panel. In this paper, we propose the automatic temperature controller, which performs automatic heating and cooling according to temperature inside the panel in order to control temperature automatically.

An Experimental Study on the Drying Characteristics of Automotive Paint Using Heating Panels and Hot Air (가열패널과 열풍을 이용한 자동차용 도료의 건조특성에 관한 실험적 연구)

  • Kim, Sung-Il;Park, Ki-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.828-836
    • /
    • 2010
  • The drying is a process that involves coupled and simultaneous heat and mass transfer. When a wet solid is subjected to thermal drying, two processes occur simultaneously. Drying is classified according to heat transfer characteristics in terms of conduction, convection and radiation. In thermal drying, radiation is easier to control than conduction and convection drying and involves a relatively simple structure. In this study, we measured energy consumption, surface hardness of paint and surface gloss with variation of surface temperature of drying materials and drying time. Drying characteristics and energy consumption between heating panels and hot air heating have been presented. The present study shows that a dryer using heating panels is more effective than a hot air dryer from the viewpoint of energy conservation. The hot air dryer, however, was not optimized and more studies on various parameters related to drying will need to be investigated for definite comparison of drying characteristics of the dryers. The result, even if limited, would present the effective availability of paint drying.

Study on the Fire Resistance of Light Weight Inorganic Polymer Concrete Panel Wall (Inorganic Polymer Concrete를 이용한 경량패널의 내화특성에 관한 실험적 연구)

  • Hwang, Ji-Soon;Kim, Woo-Jae;Kim, Dae-Hoi;Park, Dong-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.205-206
    • /
    • 2011
  • Inorganic Polymer Concrete, a type of Alkali activated cement and concrete, is known for various excellent performances, especially for better performance in the area of high temperature heat resistance(thermal characteristic) than portland cement concrete.In this study, light weight concrete panel was manufactured using this Inorganic Polymer Concrete and then evaluated for fire resistance with a small-scale heating furnace. Since the result showed excellent fire resistance, it is considered usable for manufacturing fire resistant concrete panel wall.

  • PDF

Evaluation of Fire Performance of RC Slabs with Half-Depth Precast Panels (반단면 프리캐스트 패널을 적용한 RC 슬래브의 내화성능 평가)

  • Chung, Chul-Hun;Im, Cho-Rong;Kim, Hyun-Jun;Joo, Sang-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4A
    • /
    • pp.391-398
    • /
    • 2010
  • The fire performance of RC slabs with half-depth precast panel after exposure to the ISO-834 fire standard without loading has been experimentally investigated. During heating, according to the ISO 834 fire curve, concrete spalling was observed for concrete without PP(polypropylene) fibers. No spalling occurred when heating concrete containing PP fibers. The maximum temperature of RC slabs with PP fibers with half-depth precast panel was lower than that of concrete without PP fibers. The ultimate load after cooling of the RC slabs that were not loaded during the furnace tests was evaluated by means of 3 points bending tests. The ultimate load of the RC slabs without PP fibers showed a considerable reduction (around 32.5%) of the ultimate load after cooling if compared with of RC slabs with PP fibers. The ultimate load of the RC slabs with half-depth precast panel with PP fibers is higher than that of a full-depth RC slabs with PP fibers. Also, the addition of PP fibers and the use of half-depth precast panel improve fire resistance.

The Study on the Fire Characteristic of Sandwich Panel by SBI(Single Burning Item) (SBI(Single Burning Item)을 이용한 샌드위치패널의 화재특성 연구)

  • Kim, Jung-Hyun;Kim, Heoung-Youl;Lim, Young-Soo;Lee, Seung-Han
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.493-500
    • /
    • 2010
  • 본 연구에서는 EN 13823 기준을 적용한 시험방법인 SBI(Single Burning Item)을 이용하여 스티로폼 샌드위치패널의 화재특성에 대한 실험을 실시하였다. 현재 국내에서는 샌드위치패널 화재특성 평가방법으로 ISO 5660-1(콘칼로리미터 시험방법)과 KS F 2271(난연성시험)이 사용되고 있지만 이러한 시험방법들은 시험 스케일과 시험편 및 가열조건의 한계점 등을 보이고 있다. 따라서 본 연구에서는 1세트를 3개로 하여 총 9개의 75mm 두께인 스티로폼 샌드위치 패널을 이용한 실험을 실시하였다. 이를 통해 공학적인 화재 물성 값인 FIGRA(FIre Growth RAte, kW/s), SMOGRA(SMOke Growth RAte, m2/s2)등을 측정하였다.

  • PDF

Indoor Air Temperature Distribution in a Floor Heating Space with PCM Panels (잠열저장패널이용 바닥난방공간의 실내온도분포에 관한 연구)

  • Cho, Soo;Sohn, Jang-Yeul
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.59-71
    • /
    • 1992
  • The purposes of the present study are to investigate the characteristics of heat storage and emission of the PCM($CalCl_2{\cdot}6H_2O$) panel, and to analyze the distribution of indoor air temperature in a floor heating space with PCM panels for the heating system. Two identical unit test cells sized $1.8m^W{\times}1.8m^L{\times}1.8m^H$ were built and installed with specially designed aluminium Ondol-panels. It held 1.2kg of calcium chloride hexahydrate(CCH). It was found that PCM panels could reduce the indoor air temperature fluctuations and maintain the phase changing temperature for considerably long duration, $2{\sim}3$ times longer in heating hour over no-CCH one. When the elapsed time was 6 hours, the average temperature difference between PCM panel and Ondol panel was $7.7^{\circ}C$.

  • PDF