• Title/Summary/Keyword: 가열판

Search Result 140, Processing Time 0.033 seconds

Finite Element Analysis of Heat Transfer Effects on Asphalt Pavement Heated by Pre-Heater Unit Used in Hot In-Place Recycling (유한요소해석을 통한 현장 가열 재활용 시공 장비의 가열판 용량에 따른 아스팔트 포장의 열전도성 평가)

  • Lee, Kang Hun;Lim, Jin Sun;Jeong, Kyu Dong;Im, Jeong Hyuk;Kwon, Soo Ahn;Kim, Yong Joo
    • International Journal of Highway Engineering
    • /
    • v.18 no.2
    • /
    • pp.73-82
    • /
    • 2016
  • PURPOSES: The national highways and expressways in Korea constitute a total length of 17,951 km. Of this total length of pavement, the asphalt pavement has significantly deteriorated, having been in service for over 10 years. Currently, hot in-place recycling (HIR) is used as the rehabilitation method for the distressed asphalt pavement. The deteriorated pavement becomes over-heated, however, owing to uncontrolled heating capacity during the pre-heating process of HIR in the field. METHODS: In order to determine the appropriate heating method and capacity of the pre-heater at the HIR process, the heating temperature of asphalt pavement is numerically simulated with the finite element software ABAQUS. Furthermore, the heating transfer effects are simulated in order to determine the inner temperature as a function of the heating system (IR and wire). This temperature is ascertained at $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$, and $800^{\circ}C$ from a slab asphalt specimen prepared in the laboratory. The inner temperature of this specimen is measured at the surface and five different depths (1 cm, 2 cm, 3 cm, 4 cm, and 5 cm) by using a data logger. RESULTS: The numerical simulation results of the asphalt pavement heating temperature indicate that this temperature is extremely sensitive to increases in the heating temperature. Moreover, after 10 min of heating, the pavement temperature is 36%~38% and 8%~10% of the target temperature at depths of 25 mm and 50 mm, respectively, from the surface. Therefore, in order to achieve the target temperature at a depth of 50 mm in the slab asphalt specimen, greater heating is required of the IR system compared to that of the gas. CONCLUSIONS : Numerical simulation, via the finite element method, can be readily used to analyze the appropriate heating method and theoretical basis of the HIR method. The IR system would provide the best heating method and capacity of HIR heating processes in the field.

An Experimental Study of KTP Crystal Growing by TSSG Method (TSSG 법에 의한 KTP 단결정 성장의 실험적 연구)

  • 김형천;윤경구
    • Korean Journal of Crystallography
    • /
    • v.4 no.1
    • /
    • pp.42-48
    • /
    • 1993
  • KTP(KTiOPO4) single crystals were grown by the TSSG(top seeded solution growth) method using the Ksp401s flux. A heat-pipe based growing furnace was used, and the temperature stability and the homogenity of the growing solution in the platinum crucible were within the level of It 0.5℃ and ±0.9℃, respectively. The effects of some operating variables such as operating temperature range, initial cooling rate, forced stirring, reuse of the flux were investigated. As the initial cooling rate was decreased to the degree of 0.1℃/hr and some proper stirring effect by the crystal rotation was introduced to the present experimental condition, bigger and better crystals without inclusion grew. A single crystal with the maximum sixte of 44 ×39 ×17mm3 was obtained and showed the SHG conversion efficiency of 21.39) even without the anti-refilection coating.

  • PDF

A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater (급수가열기 동체 감육 현상 규명을 위한 유동해석 연구)

  • Shin, Min-Ho;Hwang, Kyeong-Mo;Kim, Kyung-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2017-2022
    • /
    • 2004
  • There are multistage preheaters in the power generation plan to improve the thermal efficiency of the plant and to prevent the components from the thermal shock. The energy source of these heaters comes from the extracted two phase fluid of working system. These two-phase fluid can cause the so-called Flow Accelerated Corrosion(FAC) in the extracting piping and the bubble plate of the heater for example, in case of point Beach Nuclear Power Plant and in the Wolsung Nuclear Power Plant. The FAC is due to the mass transport of the thin oxide layer by the convection. FAC is dependent on many parameters such as the operation temperature, void fraction, the fluid velocity and pH of fluid and so on. Therefore, in this paper velocity was calculated by FLUENT code in order to find out the root cause of the wall thinning of the feedwater heaters. It also includeed in the fluid mixing analysis model are around the number 5A feedwater heater shell including the extraction pipeline. To identify the relation between the local velocities and wall thinning, the local velocities according to the analysis results were compared with distribution of the shell wall thicknes by ultrasonic test.

  • PDF

A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater (급수가열기 동체 감육 현상 규명을 위한 유동해석 연구)

  • Kim, Kyung-Hoon;Hwang, Kyeong-Mo;Kim, Sang-Nyung
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.24-30
    • /
    • 2004
  • Feedwater flowing tube side of number 5 high pressure feedwatrr heaters was heated by extracting steam from high pressure turbine and draining water from moisture separators and number 6 high pressure feedwater heaters and supplied into steam generators. Because the extracting steam from the high pressure turbine is two phase fluid of high temperature, high pressure, and high speed and flows to inverse direction after impinging to impingement baffle. the shell wall of the number 5 high pressure feedwater heater may be affected by flow accelerated corrosion. On May 14, 1999, Point Beach Nuclear Plant (PBNP) with operating at full power experienced a steam leak from rupture of shell side of number 4B feedwater heater. Also, d domestic nuclear power plant experienced a severe wall thinning of shell side of number 5A and 5B feedwater heaters. This paper describes the fluid mixing analysis study using PHOENICS code in order to get at the root of the shell wall thinning of the feedwater heaters. The sections included in the fluid mixing analysis model are around the number 5h feedwater heater shell including the extracting pipeline. To identify the relation between the local velocities and wall thinning. the local velocities according to the analysis results were compared with the distribution of the shell wall thickness by ultrasonic test.

  • PDF

Design Modification and Correlation Verification between Reattachment Flow of Dispersed Jet and Local Thinning of Feedwater Heater (충돌로 인해 분산된 2상 제트스팀의 재부착 현상과 국부 감육 상관관계 규명 및 설계개선에 관한 연구)

  • Kim, Hyung-Joon;Kim, Kyung-Hoon;Hwang, Kyeong-Mo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.483-495
    • /
    • 2009
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction stream line-inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes operation of experience and numerical analysis composed similar condition with real high pressure feedwater heater. This study applied squared, curved and new type impingement baffle plates to feedwater heater same as previous study. In addition, it shows difference of pressure distribution and value between single phase and two phase based on experience and numerical analysis.

Heat Transfer on a Heated Flat Plate by an Impinging Round Jet Using Liquid Crystal (Liquid Crystal을 이용한 원형충돌분류의 전열특성 연구)

  • 오승묵;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1566-1574
    • /
    • 1992
  • Local heat transfer characteristics for a round air jet impinging normally on a heated flat plate were experimentally investigated. The problem parameters investigated were jet Reynolds number, Re=4000,10000, and 20000, and nozzle-to-plate spacing(L/D) of 2,6, and 10. The temperature variations on the flat uniform heat flux surface were mapped using a thermo-sensitive liquid crytal sheet. The isochromatic images corresponding to the characteristic temperature of liquid crystal were analyzed with the help of a digital image processing system. The local Nusselt number, Nu decreased rapidly in the impingement region and exhibited a similar profiles in the wall jet region independent of the nozzle-to-plate spacing L/D. In the case of large Reynolds number, heat transfer rate (Nu) was proportional to 0.5 power of the Reynolds number. For L/D=2, a secondary peak in the heat transfer rate was seen in the region of X/D=1.5~3 due to the transition from laminar to turbulent boundary layer.

Experimental investigation of intrusive gravity current in stratified fluid (성층화된 유체 내에서 침입중력류의 실험적 연구)

  • Paik, Joong-Cheol;Son, Shin-Hye
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.173-173
    • /
    • 2012
  • 중력류는 두 유체 사이에서 물질의 종류 또는 온도차로 인한 밀도 차이에 의해 발생되는 유체의 흐름을 말하며, 자연환경에서는 저수지에서의 중층탁류, 사막에서의 모래 폭풍, 하구에서의 염수쐐기 등이 그 예이다. 여름철에 강우가 집중되는 우리나라는 홍수에 의한 범람, 침수 등이 발생할 뿐만 아니라 댐이나 하천, 호수 등에 흙탕물이 유입되어 중간층에 정체하는 중층탁류에 의한 피해가 자주 발생하고 있다. 과거에 중층탁류는 일시적인 현상에 불과하였으나 오늘날에는 인공적으로 형성된 정체성 호수나 하천에서 장기간 체류하여 생태계의 교란과 수질 악화를 초래하고 있다. 중층탁류에 의한 피해를 저감시키기 위해서는 본래 자연 상태의 하천이나 호수와 같이 온도분포가 비선형적으로 성층화 된 상태에서 탁수가 유입되어 중층탁류가 형성되는 과정과 흐름 특성을 이해하는 것이 선행되어야 한다. 본 연구에서는 중력류 흐름 해석을 위한 실험 장치를 개발하였다. 실험 장치 중 수조의 제원은 1200 $700{\times}300mm$이며, 수조 상부에는 가열장치를 설치하였고, 수조 하부에는 냉각장치를 설치하였다. 이들 장치들을 가동하여 깊이에 따른 자연현상에서의 비선형적인 온도 단면을 재현한다. 수리 실험방법은 깊이 방향으로 온도에 따라 비선형적으로 성층화 된 유체 내로 경사가 있는 판을 따라 수조내의 성층화된 유체의 중간 온도 혹은 밀도를 가진 유체를 침입시킨다. 침입유체는 성층화된 유체 내에서 초기에는 중력에 의해 운동량을 갖고 경사면을 따라 일정한 속도로 흘러내려 간다. 이후 바닥으로 하강 한 후 부력에 의해 상승하여 동일한 밀도층의 위치에서 횡방향으로 전파하게 된다. 이 연구에서는 이와 같이 비선형적으로 성층화된 유체 내에서의 침입 중력류의 흐름 특성을 실험적으로 관측하고 분석한다.

  • PDF

Development of Heater Driven by Motor by Using Eddy Current (와전류 발열장치를 응용한 모터 구동형 히터 개발)

  • Chai, Yong-Yoong;Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.935-942
    • /
    • 2019
  • This paper descries the operation of a heater which was designed to control a motor that generates an eddy current. As the motor drives the rotor of an eddy current heater, magnetic fields are provided within the air gap between an eddy current heater's rotor and stator. Throughout the research, a rotor composed of 8 and 16 pieces of magnets was used to analyze which are the factors that affect the efficiency of this equipment. Test results showed that the magnetic fields are influenced by variable functions including the velocity of a motor and the quantity of magnets composing a rotor.

Effect of Strength Increasing Sizes on the Quality of Fiberboard (섬유판(纖維板)의 증강(增强)사이즈제(齊)가 재질(材質)에 미치는 영향(影響))

  • Shin, Dong So;Lee, Hwa Hyoung
    • Journal of Korean Society of Forest Science
    • /
    • v.30 no.1
    • /
    • pp.19-29
    • /
    • 1976
  • The fiberboard and paper mills in this country are much affected by the price hikes and shortage of phenolic resins, since phenolic acid as a raw material depends on imported good. It is prerequisite to fiberboard industry to help replace with other sized and stabilize the prices and supply of them, improving the quality of boards. Thus, the present study was carried out to examine the effect of strength increasing sized such as urea formaldehyde resin (anion and cation type) and urea melamine copolymer resin, on the quality of the wet forming hardboard, and comparing them with two types of proprietary modified melamine resins, and ordinary size, phenol resin. The Asplund pulp was prepared from wood wastes mixed with 20 percent of lauan and 80 percent of pines as a fibrous material. After sizing agents were added at a pH of 4.5 for 10 minutes with alum in the beater, the stock was made in the form of wet sheet, prepared, and then performed by hot pressing cycle: $180^{\circ}C$, $50-6-5kg/cm^2$, 1-2-7 minutes. The properties of hardboard were examined after air conditioning. The results obtained are summarized as follows: 1. There is a significant difference in specific gravity among hardboards that were treated with strength increasing resins, but no difference is effected by the increase in the resin content. In the case of modified melamine resin, its specific gravity is highest. The middle group comprises cation type of urea resin, anion type of urea resin, and acid colloid of urea-melamine copolymer resin. The lowest is phenolic resin. 2. The difference of the moisture content of hardboard both by the resins and by the amount of each resin applied is significant. The moisture content of hardboard becomes lower along with the increase of each resin content, but there is no difference between 2 and 3 percent. 3. For water absorption, there is a significant difference both in the adhesives used and in the amount of paraffin wax emulsion. The water resistance becomes higher inn proportion to the content of the paraffin wax emulsion. To satisfy KS F standards of the water resistance, a proprietary modified melamine resin (p-6100) and modified cation type of urea resin (p-1500) do not require any paraffin wax emulsion, but in the case of anion type of urea resin, cation type of urea resin, and urea-melamine copolymer resin, 1 percent of paraffin wax emulsion is needed, and 2 percent of paraffin wax emulsion in the case of phenolic resin. 4. The difference of flexural strength of hardboard both by the resins and by the amount of each resin is significant. Modified melamine resin shows the highest degree of flexural strength. Among the middle group are urea-melamine copolymer resin, p-1500, anion type of urea resin, and cation type of urea resin. Phenolic resin is the lowest. The cause may be attributable to factors combined with the pressing temperature, sizing effect, and thermal efficiency of press platens heated electrically. 5. Considering the economic advantages and properties of hardboard, it is proposed that urea-melamine copolymer resin and cation type of urea resin be used for the development of the fiberboard industry. It is desirable to further develop the modified urea-melamine copolymer resin and cation type of urea resin through continuous study.

  • PDF

The Effect of Substituents on LC Behavior of Bis(p-substituted phenyl) 2-Decyloxyterephthalate (Bis(p-substituted phenyl) 2-decyloxyterephthalate의 액정 특성에 대한 치환기 효과)

  • Park, Joo-Hoon;Lee, Jong-Kyu;Choi, Ok-Byung;So, Bong-Keun;Lee, Soo-Min;Lee, Jun-Woo;Jin, Jung-Il
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.2
    • /
    • pp.127-137
    • /
    • 2000
  • Eleven new compounds that are composed of bis(p-substituted phenyl) terephthalate unitand the decyloxy pendant as lateral were synthesized and their thermal and liquid crystalline properties were studied by the differential scanning calorimetry (DSC) and on a hot-stage of a polarizing microscope. The ter-minal substituent groups of the compound were varied; X= -H(II-H), -F(lI-F), -CII(II-CI), -Br(ll-Br), -I(II-I), -$NO_2(lI-NO_2$), $-CF_3(II-CF_3$), -$OC_2H_5(II-OC_2H_5$), -$OC_4H_9(II-OC_4H_9$), -$C_6H_5(Il-C_6H_5$). The compounds of $II-OC_2H_5,\;II-OC_4H_9$ and $II-C_6H_5$ were monotropically nematic. In contrast, the compounds of Il-H, II-F, II-Cl, II-Br, II-I, $lI-NO_2$, $II-CF_3$, and II-CN did not show liquid crystalline properties.

  • PDF