• Title/Summary/Keyword: 가열시험

Search Result 566, Processing Time 0.025 seconds

Fast Cook-Off Test and Evaluation for HTPE IM Rocket Motor (HTPE 둔감 추진기관의 급속가열 시험 및 평가)

  • Lee, Do-Hyung;Kim, Chang-Kee;Yeon, Jeong-Mo;Jung, Jung-Young;Yoo, Ji-Chang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.167-170
    • /
    • 2009
  • Fast cook-off test with rocket motors was performed and characteristics of the results were analyzed. The material of the motor case was carbon epoxy composite. The motor was loaded with HTPE propellants to improve the insensitive munitions characteristics. In the tests, sound pressure and heat flux sensors were used to determine the category of response according to the standard. The reaction response of all of the HTPE motors tested by fast cook-off was judged as Type V burning.

  • PDF

Desmutagenic Activity of Heated Mountain Herb Juices (산채류(山菜類) 가열즙(加熱汁)의 돌연변이 억제 작용에 관(關)한 연구(硏究))

  • Ham, Seung-Shi
    • Applied Biological Chemistry
    • /
    • v.31 no.1
    • /
    • pp.38-45
    • /
    • 1988
  • Potential mutagenicity of ten heated edible mountain herbs were examined with spore recassay, Ames test and DNA breaking test. Samples of edible mountain herbs were prepared with water extraction at $100^{\circ}C$ for 20 minutes. With the rec-assay, no significant mutagengic activity could be obtained from all of the samples, but among the eight of metal ions added to sample solution, $Pb^{2+}$ to R. crispus heated juice, $Zn^{2+}$ to L. fischeri and S. bracycarpa heated juice increased mutagenic activity of the samples. With the Ames test and DNA breaking test, all of the samples did not show mutagenicity. However, breaking action was activated on heated L. fischeri, P. japonicus. A. triphylla and A. tataricus juices in the presence of 25mM $Cu^{2+}$. But heated A. elata, H. aurantiaca, A. triphylla, S. bracycarpa and A. scaber juices were inactivated in the presence of 25mM $Fe^{2+}$. Desmutagenic activities against benzo$({\alpha})$pyrene significantly increased as increasing concentration of the heated edible mountain herb juices.

  • PDF

Flame Resistance and Durability of Compressed Structural Wood through Microwave Heat Drying Method (마이크로파 가열건조법에 의한 압축 구조용 목재의 방염 및 내구성)

  • Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.162-170
    • /
    • 2011
  • As the result of implementing a treated material test and durability test after quickly drying S.P.F. species, a type of softwood structural material, within a short period time, soaking it in liquid phosphate flame proof agent for an hour, microwave heating it, and compressing it from 3.8cm to 1cm, when setting the appropriate heating time of microwave heating at 7 minutes at 5kW, it is observed that it satisfies the target water content (4~5%). It is shown that in a water content measurement of the wood that is compressed after being softened by soaking in the flame proof agent, drying and heating at 3kW for 9 minutes, all specimens satisfied 12~14%, the appropriate water content for exterior wood. Also, it is shown that in terms of the flame performance obtained through a flame resistance treatment of the compressed wood and a treated material test, the specimen soaked in flame proof agent for 30 minutes was the most excellent, and that the performance test result of the compressed wood in all areas, such as nail withdrawal resistance, compression, bending strength, and shearing strength, were all improved in their mechanical features to twice to three times better performances.

공력가열 시험설비 설계

  • Ok, Ho-Nam;Kim, In-Sun;Ra, Seung-Ho;Kim, Seong-Lyong;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.155-169
    • /
    • 2004
  • Space launch vehicles and reentry vehicles are exposed to extreme heating conditions due to high aerodynamic heating while flying at high Mach numbers in the atmosphere. To protect the vehicle itself or the payload from the aerodynamic heating, the thermal load imposed on the surface should be exactly predicted and proper thermal protection should be applied based on the prediction results. But this requires rigorous thermal analysis and testing to prevent loss of payload capacity caused by excessive heat shielding, and the amount of thermal protection material to be applied is determined through aerodynamic heating tests. Various design points to be considered to upgrade the prototype aerodynamic thermal simulation facility(ATSF) used for the KSR-series sounding rocket development to the one suitable for the KSLV(Korean Space Launch Vehicle)-series launch vehicle are considered in this research. The need and limitation for the facility are first considered, and the functions required for KSLV testing are determined. The specifications of the upgraded facility are briefly suggested and these results will be used for the future fabrication and installation of the facility.

  • PDF

Performance Test of Vitiated Air Heater with High Temperature and High Pressure (고온 고압 공기가열기 성능시험)

  • Lee, Jungmin;Na, Jaejeoung;Hong, Yunky;Kim, Jeongwoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • This study presents the performance test results and the analyses of the vitiated air heater with high temperature and high pressure. In the performance test, four test conditions and three rake measurement conditions were implemented. In the results of the performance test, the vitiated air heater met targets of temperature and flow rate, and the performance with maximum temperature of 2000 K and maximum combustion pressure of 40 bar was confirmed. Flow rate of provided methane increased 36% more than what was calculated, and 19.6% difference was displayed between measured temperature and theoretically calculated temperature.

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

The measurement equipment for 915MHz 30kW class magnetron test (915MHz 30kW 마그네트론 시험을 위한 측정 장비)

  • Cho, Kook-Hee;Jeon, Seok-Gy;Jung, Sun-Shin;Lee, Hong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1570-1571
    • /
    • 2006
  • 산업용 가열, 건조, 해동 기술 분야에서 피 가열물의 열전달 특성이 좋지 않은 경우 대출력 마그네트론을 적용하여 전자파 가열방식을 이용함으로써 기존의 가열방식 보다 효율을 상당히 개선할 수 있음은 오래 전부터 알려져 왔다. 그러나 국내에서는 대출력(30kW급 이상) 마그네트론 제조기술 및 성능분석을 할 수 없어 외국에서 수입하여 산업에 산발적으로 적용하고 있는 실정이다. 따라서 본 연구는 30 kW급 대출력 마그네트론과 구동전원을 위한 시험 장비를 구축하여 신뢰성을 확보하면 마그네트론을 이용한 고효율 가열, 건조, 해동 기술에 적용이 가능하다.

  • PDF

Evaluation of Tensile and Compressive Performance of CFRP Rebars according to Heating Temperatures (가열온도에 따른 CFRP Rebar의 인장 및 압축 성능 평가)

  • Jae-Hee Lee;Sung-Won Yoo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2024
  • The demand for FRPs that are corrosion-free and have an excellent tensile strength-to-weight ratio. However, there is a lack of research on the mechanical properties of FRP in the form of rebars, especially the changes in performance due to heating. Therefore, in this paper, 60 tensile and compression specimens of CFRP rebars with a diameter of 12 mm were fabricated and subjected to direct tensile and direct compression tests, and their performance was evaluated according to the heating temperature. It was found that as the heating temperature increases above 300 ℃, the performance decrease becomes larger due to the burning of epoxy. The compressive strength was found to be much lower than the tensile strength, but the modulus of elasticity was found to be the same in tension and compression.

Safety Evaluation of a Shipping Capsule for Special Form Radioisotope (특수형 방사성 동위원소 운반캡슐의 안전성 평가)

  • Lee, Ju-Chan;Seo, Ki-Seog;Ku, Jeong-Hoe;Bang, Kyoung-Sik;Han, Hyon-Soo;Park, Seong-Won
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • All of sealing capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this study is to demonstrate the safety of a shipping capsule for $^{192}Ir$ special form radioisotope which produced in the HANARO. The safety tests were carried out for the impact, percussion, bending and heat test conditions. And leakage tests were carried out before and after the each test. Also, the safety analyses wert performed using computer codes in order to verify the test results. The capsule showed slight scratches and deformation, and maintained its structural and thermal integrities in all tests without any severe damage or melting. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form.

  • PDF

Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System (방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능)

  • Oh, Chang-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • A currently used roof green system with multi layers has a low constructability. Therefore a new integrated waterproof & root barrier sheet and roof green box unit system was developed using steel plate fixture and cone type fixture by electromagnetic induction heating method. This study was proceeded to evaluate adhesion performance of two types of fixtures on Engineering PE, TPO, PVC sheet in a normal condition, repeated heating and cooling condition. As a result, adhesion load on Engineering PE sheet showed the highest value. The adhesion loads of steel plate fixture showed higher value as heating temperature was getting higher. However adhesion loads of cone type fixture showed opposite tendency. Regarding to the test conditions, test results of normal condition, repeated heating and cooling condition showed same value. The cone type fixture using butyl tape showed 7 times lower adhesion load than that of cone type fixture using electromagnetic heating and 28% lower adhesion load in a repeated heating and cooling condition than a usual condition.