A Study on the Relief of Shell Wall Thinning of High pressure Feedwater Heater (고압형 급수가열기 동체 감육 완화에 관한 연구)

  • Kim, Hyung-Joon;Park, Sang-Hoon;Seo, Hyuk-Ki;Kim, Kyung-Hoon;Hwang, Kyung-Mo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2664-2669
    • /
    • 2008
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction stream line- inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes operation of experience and numerical analysis composed similar condition with real high pressure feedwater heater. This study applied squared, curved and new type impingement baffle plates to feedwater heater same as previous study. In addition, it shows difference of pressure distribution and value between single phase and two phase based on experience and numerical analysis.

  • PDF

Shell Wall Thinning and Mitigation Plan and Design Modification of a Feedwater Heater Impingement Baffle (급수가열기 동체 감육 현상과 완화 방안 및 충격판 설계개선)

  • Kim, Kyung-Hoon;Hwang, Kyeong-Mo;Park, Sang-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.6
    • /
    • pp.55-63
    • /
    • 2010
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feedwater heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare degree of shell wall thinning mitigation rate to squared type with mitigation rate of other type baffle plate, three different types of impingement baffle plate-squared, curved and mitigating type-applied inside the shell. With these comparison data, this paper describes operation of experiments and numerical analysis which is composed similar condition with real feed water heater. And flow visualization is operated for verification of experiments and numerical analysis. In conclusion, this study shows that mitigating type baffle plate is more effective than other baffle plate about prevention of pressure concentration and pressure value decrease.

A Numerical Study on the Thermal Performance of a Solar Air Heater Depending on the Hole Configuration and Geometry in the Absorber Plate (태양열 공기가열기의 흡열판 홀 배치와 형상에 따른 열적 성능에 관한 수치해석적 연구)

  • Shin, Jae Hyuk;Boo, Joon Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.69-80
    • /
    • 2015
  • A series of numerical analyses was conducted to predict the thermal performance of a solar air heater depending on the hole configuration and geometry in the absorber plate. The planar dimensions of the prototype were 1 m (W) by 1.6 m (H), and the maximum air flow considered was $187m^3/h$. It was considered that protruding holes with a triangular opening in the absorber plate would invoke turbulence in the air flow to enhance the convection heat transfer. Six different hole configurations were investigated and compared with each other, while the hole opening height was considered as a design variable. Three-dimensional transient analyses were performed with a commercial software package on the airflow and heat transfer in the model. The numerical results were analyzed and compared from the view point of the outlet air temperature and its time response to derive the optimal hole pattern and hole opening height.

Effect of Heating Medium and Evaporation Temperatures on Concentration of Garlic Juice (가열 매체 및 증발온도가 마늘즙의 농축에 미치는 영향)

  • Kim, Byeong-Sam;Park, Noh-Hyun;Park, Moo-Hyun;Han, Bong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.301-305
    • /
    • 1992
  • Effect of heating medium and evaporation temperatures on a concentration ratio, a evaporation rate and a overall heat transfer coefficient during concentration of garlic juice by a centrifugal thin film evaporator were investigated. At constant feeding rate and evaporation temperature, the concentration ratio, the evaporation rate and the overall heat transfer coefficient increased with the increase of the steam temperature but those values increased slowly or decreased as a steam temperature exceeded $110^{\circ}C$. At the feeding rate of 50 kg/h and the steam temperature of $100^{\circ}C$ and below, those values decreased with the increase of evaporation temperature. But if a steam temperature became $100^{\circ}C$ and up, those values increased slowly and then decreased with the increase of the evaporation temperature until the evaporation temperature reached a critical value. At constant feeding rate, those values increased until the temperature difference between steam and evaporation temperatures became $70^{\circ}C$. But if they become larger than $70^{\circ}C$, those values increased slowly and then decreased.

  • PDF

AMOLED Aging Chamber Signal Generation and Heating System (AMOLED 에이징 챔버 신호 생성 및 가열 시스템)

  • Lee, Byungkwon;Cho, Kwanghee;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.861-866
    • /
    • 2018
  • In OLED (Organic Light-Emitting Diode) manufacturing, the aging process increases the manufacturing efficiency and measures the correction value to correct the aging. The correction value for correcting the aging of the OLED can be applied to the driving signal. The OLED aging process measures the current after outputting the light for a predetermined time according to the preset driving signal and temperature. In the OLED manufacturing process, aging is applied for non-uniformity by deposition and temperature. This time has little effect on OLED efficiency reduction. Heating devices and signal generation systems are required to create the conditions necessary for aging. The results measured by the heating system and signal generation system can be used as a basis for evaluating power requirements, uniformity and efficiency in OLED manufacturing. In this paper, we propose and implement a configuration for interlocking the driving signal generation and heating system for practical OLED aging correction.

High Power Factor Dual Half Bridge Series Resonant Inverter for an Induction Heating Appliance with Multiple Loads (다부하를 갖는 유도가열기기를 위한 고역률 이중 하프브릿지 직렬공진 인버터)

  • 정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.307-314
    • /
    • 1998
  • A novel high power factor Dual Half Bridge Series Resonant Inverter (DHB-SRI) for an induction heating appliance with multiple loads is proposed to remove the interferential acoustic noise caused by the difference between operating frequencies of adjacent loads. The circuit enables independent full power range control of two induction heating elements by one inverter circuit and has minimum switching losses due to the zero voltage switching characteristic. According to the mode analysis, I will explain the operation of the proposed circuit. To evaluate the required cooling capacity, loss analysis is performed through deriving some loss equations. In order to obtain the power factor correction capability and to lessen the system size, suitable design guides are given. Using the designed values, the proto-type circuit with 2.8kW power consumption for each induction heating element is built and tested to verify the operation of the proposed circuit.

  • PDF

냉동수산식품 HACCP 관리 기준

  • 식품의약품안전청
    • Food Industry
    • /
    • s.219
    • /
    • pp.24-60
    • /
    • 2011
  • ${\bigcirc}$ 본 업소는 수산물가공품(냉동어류, 냉동연체류, 조미가공품)을 생산하는 식품제조 가공업소로서 총 5명의 인원이 수산물가공품 8개 제품을 생산하여 매출액은(약 00원)이며 주로 집단급식소에 판매하고 있다. ${\bigcirc}$ 본 업소의 수산물가공품은 냉동생선 해동(또는 냉장생선 이용), 전처리(냉장제거 등) 이후 세척 후 급냉하여 포장하거나(냉동어류 및 냉동연체류) 가열 후 포장하여 급냉하는(조미가공품) 공정을 거쳐 생산된 제품으로 원료 취급과정에서의 오염이나 불충분한 가열, 교차오염 등으로 식중독균(병원성대장균, 황색포도상구균 등)과 원료 및 제조과정에서 이물(금속 등)이 혼입할수 있으며, ${\bigcirc}$ 이로 안한 주요클레임 발생사례는 최근 3년간 관계당국으로부터 대장균군 검출 3건, 소비자클레임 2건이 있었다. - 연도별 주요 클레임내용은 '08년도에는 대장균군 검출 3건, '09년도 냉동어류에서 날벌레 이물 검출 1건, '10년도에는 냉동연체류에서 철수세미 1건 이었다. ${\bigcirc}$ 이러한 위해발생을 사전에 예방하기 위해 중점관리해야 하는 공정은 세척공정(냉동어류 및 냉동연제류) 및 가열공정(조미가공품)으로 판단되며, 금속 등의 이물 혼입 또한 중점적으로 관리할 필요성이 있다. ${\bigcirc}$ 본 업소에서 생산하는 냉동어류 및 냉동연체류는 세척공정에서 세척시간과 세척수량, 원물량을 각각 설정하여 CCP 1로 관리하고 2시간마다 모니터링하고 있으며, ${\bigcirc}$ 조미가공품은 가열온도와 시간을 각각 설정하여 CCP 2로 관리하고 있으며, 품온이 $85^{\circ}C$이상 유지할수 있도록 2시간마다 모니터링하고 한계기준 이별여부를 기록하도록 하고 있다. ${\bigcirc}$ 또한 금속검출공정을 CCP 2로 관리하여 2mm${\varphi}$ 이상의 금속이물 혼입여부를 상시 확인하고 있으며, 금속검출기가 정상 작동여부를 4시간마다 모니터링하고 기록하도록 하고 있다. ${\bigcirc}$ 종합적인 공정 및 일반위생관리를 위해 개인위생 상태 냉동 냉장고 온도 확인 등 총 29개 항목에 대하여 정기적 점검(매일 17 주간 4 월간 4 분기 1, 연간 3)을 실시하고 있으며, ${\bigcirc}$ 따라서 지속적인 모니터링을 통해 미흡사항의 원인으로 파악하고 문제점 제거를 위해 체계적이고 지속적인 관리가 필요하다.

  • PDF

A Study on Accident Frequency by Installing Safety Devices in the LPG Heating and Drying Furnace (LPG 가열로 및 건조로의 안전장치 설치에 따른 사고빈도에 관한 연구)

  • Song, Dong-Woo;Kim, Ki-Sung;Kim, Choong-Hee;Lee, Seong-Gueong;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.49-54
    • /
    • 2015
  • The purpose of this study is to assess the risk of depending on the presence or absence of safety device of domestic heating and drying furnaces, by derivation and analysis of accident frequency of safety devices through FTA (Fault Tree Analysis). Installation standards are lacking in Korean for the safety device of LPG heating and drying furnace, which have a risk of explosion due to structure to trap the leaked gas. Four different safety devices were selected on the basis of NFPA and national standards for combustors of other equipment. Effects of frequency reduction in accidents were analyzed before and after installing the safety devices respectively. As a result, a minimal leakage safety device was presented for preventing damages from gas leak of domestic LPG heating and drying furnace.

Critical Heat Flux in Uniformly Heated Rod Bundle Under Wide Range of System Pressures (광범위한 압력조건하에서 균일 가열 수직 봉다발에서의 임계열유속)

  • Moon, Sang-Ki;Chun, Se-Young;Choi, Ki-Yong
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.195-200
    • /
    • 2001
  • An experimental study on critical heat flux (CHF) has been performed for water flow in a uniformly heated vertical 3 by 3 rod bundle under low flow and a wide range of pressure conditions. The objective of this study is to investigate the parametric trends of CHF with 3 by 3 rod bundle test section where three unheated rods exist. The general trends of the CHF are coincident with previous understandings. At low flow and system pressure above 3 MPa, some critical qualities are larger than 1.0 due to counter-current flow in test sections. Since there is a supply of water to the heated section from unheated section, the maximum CHFs at system pressure between 2 and 4 MPa are not shown.

  • PDF

Bonding Technology for PZT and Connection board using a High Frequency Heating Machine. (고주파 가열기를 이용한 PZT와 연결기판의 접합기술)

  • Lee, Jong-Hyun;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.89-94
    • /
    • 1999
  • In this study, a new technology to bond the PZT with connection board, which is a core technology for the fabrication of medical micro high frequency sensors, was developed. Two technologies were adopted. One is bonding of In using thermal heating, he other is bonding of Pb using a high frequency heating machine. In case of thermal eating, bonding was failed because of the contaminations of In surface. But, when using high frequency healing machine, we developed good bonding characteristics at various experimental conditions and thickness of the electrode material.

  • PDF