• Title/Summary/Keyword: 가슴호흡

Search Result 49, Processing Time 0.031 seconds

Effects of Thorax Mobility Exercise on the Thorax Mobility, Breathing Pattern and Respiratory Capacity in Subject With Restricted Thorax Mobility: A Case Series (가슴 가동성 제한을 가지고 있는 대상자에게 가슴 가동성 운동이 가슴가동성, 호흡패턴 및 호흡량에 미치는 효과: 사례 시리즈)

  • Ha, Sungmin
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 2023
  • Objective : To investigate the effects of thorax mobility exercises on thorax mobility, breathing pattern, and respiratory capacity in subjects with restricted thorax mobility. Methods : Thirteen subjects with restricted thorax mobility participated in this study. Measurement of thorax circumference using a tape measure (difference between inhalation and exhalation), breathing pattern (distance of rib cage elevation during breathing), and respiratory capacity was performed. Paired t-test was used to compare the thorax mobility, breathing pattern, and respiratory capacity between before and after thorax mobility excercise. Statiscal significance was set at .05. Results : There were significant differences in thorax mobility and breathing pattern, but no significant difference in respiratory capacity (p < .05). Conclusion : Based on the results of this study, thorax mobility exercise using the rib mobilization technique is considered to be a method that can improve thorax mobility and normalize abnormal breathing patterns that cause rib cage elevation.

Relationship between Breathing Pattern Disorder and Pain in Patients with Chronic Low Back Pain (만성요통환자의 호흡패턴이상과 통증과의 상관관계)

  • Lim, Chae-Gil
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.355-363
    • /
    • 2020
  • To investigate the relationship between breathing pattern disorder and pain in patients with chronic low back pain(CLBP). One hundred four patients were measured the End-tidal CO2(EtCO2) and respiration rate(RR) using capnography. Also, The Breathing-hold time(BHT), Nijmegen Questionnaire(NQ), and Thoracic excursion examinated. There was a significant correlation between EtCO2 and BHT, thoracic excursion(r=.302, r=.281)(p<.01), and a low negative correlation with RR, VAS(r=-.253, -200)(p<.05). There was a significant correlation between NQ and RR(r=.237)(p<.05). There was a low correlation between thoracic excursion and VAS(r=-.370)(p<.01). There was a significant difference in the EtCO2, RR, BHT, thoracic excursion, and VAS between the thoracic and diaphragm breathing pattern(p<.05). There were no significant differences in the NQ(p>.05). There was a correlation between EtCO2 and BHT, thoracic excursion, RR, VAS in patients with CLBP. In addition, There was a correlation between RR and NQ, thoracic excursion, and VAS. As a result, it was found that there is a close relationship between breathing pattern disorder and pain. There was a significant difference in the EtCO2 level, RR, BHT, thoracic excursion and VAS value in the comparison of thoracic breathing pattern and diaphragm breathing pattern. This is a meaningful result of suggesting a breathing pattern treatment approach in the rehabilitation and pain management of chronic low back pain patients in clinical practice.

A Respiratory Rate Monitoring System during Sleep using a Depth Camera (깊이 카메라를 이용한 수면중 호흡률 모니터링 시스템)

  • Moon, Chanki;Nam, Yunyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.04a
    • /
    • pp.561-563
    • /
    • 2015
  • 본 논문은 깊이 카메라를 이용하여 수면중에 가슴의 움직임만으로 호흡률을 예측하는 시스템을 제안한다. 카메라는 취침하는 사람의 머리 위에 위치하였으며, 취침하는 사람의 가슴 주변을 관심 영역으로 지칭하여 깊이 값의 변화를 추출하여 노이즈를 제거한 후 FFT를 계산하여 호흡률을 계산하였다. 실행에서 10명의 지원자를 대상으로 0.1 Hz 부터 0.4 Hz까지 측정하여 약 98%의 정확률을 얻었다.

A Comparison of Accuracy in Artificial Respiration and Chest Compression Depending on Position, Gender, and Weight of a Victim Given Cardiopulmonary Resuscitation (심폐소생술 시행 시 피구조자의 위치, 성별, 체중에 따른 가슴압박과 인공호흡 정확도 비교)

  • Baek, Hong-Seok;Park, Sang-Sub
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.280-290
    • /
    • 2011
  • The purpose of this study was to increase accuracy in performing cardiopulmonary resuscitation through comparing accuracy between chest compression and artificial respiration depending on position, gender, and weight of a victim given conducting cardiopulmonary resuscitation. This study randomly sampled 72 college students in G Province (36 in the experimental group and 36 in the control group) to conduct a research from November 5 to 19, 2009. The collected data were analyzed by using an SPSS WIN 12.0 Version program. Since the results showed that most regions got more effective artificial respiration and chest compression on the right side than on the left side, it is necessary to apply cardiopulmonary resuscitation on the right side in terms of how to implement and instruct cardiopulmonary resuscitation in the future. However, it seems that continuous researches are necessary to see if cardiopulmonary resuscitation is more effective on the right side in terms of the survival rate in an actual emergency.

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

Accuracy analysis of artificial respiration and chest compressions when performing CPR using a mannequin by college students (대학생의 마네킹을 이용한 심폐소생술 시행 시 인공호흡과 흉부압박의 정확도 분석)

  • Jeon Jai-In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.167-173
    • /
    • 2023
  • The purpose of this study was to analyze the accuracy of artificial respiration and chest compressions using CPR mannequins for university students. First, in the number of chest compressions, subjects A, F, H, I, and J showed similar numbers from 60 to 63, respectively, which were much lower than the standard. Subjects B, D, E, and G showed 90 to 91 times, maintaining the normal range. However, C was rather high with 119 times. Second, the depth of chest compression was 58.60mm, and most of them were deeply compressed. Subject C was close to normal at 51mm, and subjects A to J were significantly higher at 55mm to 62mm. The reason seems to be the result of an unstable psychological state with no experience of chest compressions and a lack of self-confidence. Third, in terms of accuracy, subject E showed the lowest accuracy at 12%, and A~J showed 33%~80%. Experiment subject B showed 95% accuracy, which seems to be the result of D accurately recognizing the chest compression point through theoretical training during military service.

Research on Vocal Breathing Method Applied by Abdominal Breathing (복식호흡법을 응용한 보컬 호흡법에 관한 연구)

  • Cho, Tae-Seon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.204-207
    • /
    • 2009
  • 일반적으로 가창을 위한 호흡법으로는 두 가지를 들 수 있다. 가슴의 횡격막 부분을 사용하는 복식호흡법과 배꼽 밑 부분의 아랫배를 활용한 단전호흡법으로 나눌 수 있다. 일반적으로 윗배를 사용하는 복식 호흡법의 경우 주로 성악 발성에서 사용 하였으며, 아랫배를 활용한 단전호흡법의 경우 창이나 판소리 등의 국악 창법에 많이 사용되었다. 상대적으로 역사가 짧은 대중음악의 경우는 특정한 호흡법이 없고 누구에게 배웠느냐에 따라 호흡하는 방법이 결정되었다. 그러나 매스미디어가 발전함에 따라 대중음악 분야도 발전하게 되었고, 대중가요 가수들을 위한 독창적인 호흡법도 절실히 필요하게 되었다. 따라서 본 연구에서는 가창력을 증진 시킬 수 있는 효과적인 호흡법을 제시해 보고자 한다.

  • PDF

Comparison of CPR Results And Muscle Fatigue According to Chest Compression Performer's Own Breathing Method

  • Jun-Ho Jung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.12
    • /
    • pp.175-182
    • /
    • 2023
  • In this paper, we propose a study compared and analyzed the CPR results and muscle fatigue of the three groups. There is a group that counts loudly when compressing the mannequin's chest (Group A), a group that breathes autonomously without counting (Group B), and a group that breathes abdominally without counting (Group C). Twelve people were assigned to each group, and after performing chest compressions for 5 minutes, the results of CPR were analyzed using a program connected to the mannequin, and the muscle fatigue of the performers was analyzed using wireless electromyography. The most efficient method was found to be group B. If we only look at the speed and depth of compression within the normal range, Group C would be more efficient, but Group B showed significantly lower muscle fatigue, and Group A did not reach the normal range in depth of chest compression and muscle fatigue was the highest. Group B was also found to be the most accurate in hand positioning accuracy, and was also found to be the most efficient in maintaining concentration on chest compressions.

Effect of Chest Compression Position Depending on the Rescuer's Hip Joint Angle During Basic CPR (심폐소생술 수행자의 엉덩관절 각도가 심폐소생술 결과에 미치는 영향)

  • Lee, Jae-Min;Yun, Hyeong-Wan
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.103-109
    • /
    • 2020
  • This study aims to investigate the improvement in basic CPR quality on the basis of the hip joint angle of the rescuer among students in the Department of Emergency Medical Technology who completed a basic CPR curriculum. In this study, we carried out a comparative analysis using SimPad SkillReporter and Resusci Anne® QCPR® to measure the quality of CPR (depth of chest compressions, full relaxation, compression speed, and more) on the basis of the rescuer's hip joint angle in accordance with the 2015 AHA Guidelines and conducted chest compressions and CPR 5 times in a 30:2 ratio. It was found that maintenance of the rescuer's hip joint angle at 90 degrees while compressing and relaxing the chest made a statistically significant difference in both the experimental and control groups. Moreover, this indicated that the closer the hip joint angle was to 90 degrees, the better was the quality of basic CPR. However, there was no significant difference in the hip joint angle, degree of CPR, depth of chest compressions, chest compression speed, chest compression and relaxation percentages (%), accuracy of chest compressions, hands-off time during CPR, and percentage of chest compression time (p > 0.05). Maintaining the hip joint angle at 90 degrees for basic CPR was not significantly different from not maintaining this angle. Nonetheless, good results have been obtained at moderate depth and 100% recoil. Therefore, good outcome and high-quality CPR are expected.

A Respiratory Rate Monitoring System using a Depth Camera in the Sitting Position (깊이 카메라를 이용한 앉은 자세에서의 호흡률 모니터링 시스템)

  • Moon, Chanki;Nam, Yunyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.544-547
    • /
    • 2015
  • 본 논문은 깊이 카메라를 이용하여 가슴의 움직임만으로 호흡률을 예측하는 시스템을 제안한다. 카메라는 실험자의 흉부 앞에 위치하였으며, 흉부를 관심 영역으로 지정하여 깊이 값의 변화를 추출하였으며 노이즈를 제거한 후 Welch 메소드와 AR 메소드를 이용하여 호흡률을 계산하였다. 계산된 호흡률을 검증하기 위하여 공기 흐름 측정 센서를 이용하여 호흡률을 계산하고 비교하였다. 실험에서 10명의 지원자를 대상으로 0.1 Hz 부터 0.4 Hz까지 측정하여 약 98%의 정확률을 얻었다.