• Title/Summary/Keyword: 가스 부하

Search Result 1,759, Processing Time 0.032 seconds

Effect of Water Soluble fraction from Japanese Larch Wood on Sawdust Cultivation of Lentinula edodes (일본잎갈나무재의 수용성추출물 첨가가 표고버섯의 톱밥재배에 미치는 영향)

  • Cho, Nam-Seok;Chung, Hung-Chae;Kim, Dong-Hun;Lee, Sang-Sun;Ohga, Shoji;Leonowicz, A.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.35-44
    • /
    • 2004
  • The water soluble fractions(WSF) from Japanese larch wood were isolated, purified by anion exchange resin and Sephadex gel filtration and identified its chemical structure by means of periodate oxidation and methylation reactions. Its major components are arabinose and galactose (1 : 3.4). Based on the results of periodate oxidation, methylation and gas chromatographic analysis of purified WSF, main chain is composed of β-1,3-glycosidic linkage among D-galactopyranoses, and two different side chains; β-1,6-glycosidic linkage among 2-3 units of D-galactopyranoses and β-1,6-glycosidic linkage between 1-2 units of D-galactopyranose and L-arabinopyranose. Addition of WSF to culture media of oak mushroom (Lentinula edodes) accelerated the mycelial growth. In the case of PDA cultures, 2 percent addition of WSF in Sanlim No. 6 strain and 4 percent of WSF in Mok-H strain mostly enhanced the mycelial growth of the mushroom. In the case of sawdust cultures, 4 percent addition of WSF in two strains showed the best mycelial growth. High percentages addition of WSF inhibited mycelial growth of the mushroom. Mushroom production was increased with addition of WSF. By the addition of WSF, ergosterol contents in the media were quite high at the colonized stage and rapidly increased at the fruiting stage. Therefore the ergosterol content could be utilized as an indicator to evaluate the culture maturity for the mushroom fruiting.

Evaluation of Mechanical Performance Considering Prolonged Length of Glass Fiber-Reinforced Composite on Structure Weakness by Thermal Stress at Secondary Barrier in Cryogenic Liquified Gas Storage (극저온 액화가스 화물창 2차방벽 구조 열 응력 취약 부 Prolonged 길이 고려 유리섬유 강화 복합재 기계적 물성 평가)

  • Yeon-Jae Jeong;Hee-Tae Kim;Jeong-Dae Kim;Jeong-Hyun Kim;Seul-Kee Kim;Jae-Myung Lee
    • Composites Research
    • /
    • v.36 no.4
    • /
    • pp.246-252
    • /
    • 2023
  • A secondary barrier made of glass fiber reinforced composites has been installed infinitely using automatic bonding machine(ABM) in membrane type LNG cargo containment system (CCS). At the same time, significant thermal stress due to cryogenic heat shrinkage has occurred in the composite on the non-bonding area between the adhesive fixation at both ends. There have been studies from the perspective of structural safety evaluation taking this into account, but none that have analyzed mechanical property taking an prolonged length into account. In this study, 2-parameter Weibull distribution statistical analysis was used to standardize reliable mechanical property for actual length, taking into account the composite's brittle fracture of ceramic material with wide fracture strength dispersion. Related experimental data were obtained by performing uniaxial tensile tests at specific temperatures below cryogenic condition considering LNG environment. As a result, the mechanical strength increased about 1.5 times compared to -20℃ at -70℃ and initial non-linear behavior of fiber stretched was suppressed. As the temperature decreased until the cryogenic, the mechanical strength continued to increase due to cold brittleness. The suggested mechanical property in this study would be employed to secure reliable analysis support material property when assessing the safety of secondary barrier's structures.

Risk Assessment of Marine LPG Engine Using Fuzzy Multicriteria HAZOP Technique (퍼지 다기준 HAZOP 기법을 이용한 해상용 LPG 엔진의 위험성 평가)

  • Siljung Yeo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.238-247
    • /
    • 2023
  • Liquefied petroleum gas (LPG) is an attractive fuel for ships considering its current technology and economic viability. However, safety guidelines for LPG-fueled ships are still under development, and there have been no cases of applying LPG propulsion systems to small and medium-sized ships in Korea. The purpose of this study was to perform an objective risk assessment for the first marine LPG engine system and propose safe operational standards. First, hazard and operability (HAZOP) analysis was used to divide the engine system into five nodes, and 58 hazards were identified. To compensate for the subjectivity of qualitative evaluation using HAZOP analysis, fuzzy set theory was used, and additional risk factors, such as detectability and sensitivity, were included to compare the relative weights of the risk factors using a fuzzy analytical hierarchy process. As a result, among the five risk factors, those with a major impact on risk were determined to be the frequency and severity. Finally, the fuzzy technique for order of preference by similarity to ideal solution (TOPSIS) was applied to select the risk rank more precisely by considering the weights of the risk factors. The risk level was divided into 47 groups, and the major hazard during the operation of the engine system was found through the analysis to be gas leakage during maintenance of the LPG supply line. The technique proposed can be applied to various facilities, such as LPG supply systems, and can be utilized as a standard procedure for risk assessment in developing safety standards for LPG-powered ships.

하계 전기, 전자연합학술회의 및 산학협동 심포지엄 초록

  • 대한전기학회
    • 전기의세계
    • /
    • v.27 no.5
    • /
    • pp.33-54
    • /
    • 1978
  • (차례) 1.산학협동심포지업 (1)우리나라에서의 연구개발과 산학협동 (2)산학협동과 산업계의 역할 (3)산학협동의 현황과 진로 2.학술회의A (1)전력게통의 계층구조와 협조원리에 관한 연구 (2)2중층괴상회전자 유도전동기의 이론해석 (3)초고주파가열장치에 사용하는 철공진변압기의 해석적 설계 (4)한국전기기시험연구소 대전력단락 시험설비설계 (5)직류전동기제어를 위한 Thyristor Chopper정류회로에 관한 연구 (6)선로의 개폐정보를 포함하는 전력계통의 상태추정 (7)단일신경세포에 대한 ITEM 신호 특성 3.학술회의B (1)MMM-1 Computer System의 설계 및 제작 (2)Adaptive Delta Modulation System의 성능비교 연구 (3)6GHZ FMD마이크로파 무선전송장치의 개발 (4)적선도에 의한 회로망함수의 결정 (5)동맥혈압의 해석과 그의 전기적 유사모델 (6)피부감각의 정보전달 특성에 관하여 (7)선형직접회로의 공정설계 및 그 특성 조성 (8)DH L.D의 전기적포화현상에 관한 이론적 해석 (9)Potocoupler를 이용한 Isolator 4.학술회의C (1)Al-Al$_{2}$O$_{3}$ -Al박막구조의 전기적 특성 (2)이종금속에 샌드위치된 고분자물질의 단락전조 (3)유전체가 일부체워진 직 6면체의 캐비티의 다중모오드 해석 (4)반도체 가스 검지소자의 제조 및 그의 전기적 특성 (5)실리콘 산화공정에 대한 실험적 고찰 (6)진공증착법에 의한 InSb 박막제도에서 열처리효과 (7)(Ba$_{1}$-xBix) Tio$_{3}$ PTC thermistor의 첨가량의 최적건안 (8)금속박막증착시 두께조절 5.특별강연회 (1)일본에 있어서의 절력계통공학연구 (2)Linear Motor의 최근개발동향량도 높았다. valine과 leucine 및 aspartic acid, glycine과 glutamic acid, leucine과 aspartic acid 간에는 고도의 정상관, glycine과 serine, valine과 phenylalanine, threonine과 proline, phenylalanine과 arginine, methionine과 glutamic acid, histidine과 lysine 간에는 유의 정상관, 그리고 isoleucine과 lysine 간에는 유의한 부상관이 있었다. 4. lysine 함량은 단백질 함량과 정산곤, isoleucine 함량은 단빅질 함량과 부상관을 보였으며, alanine, valine, leucine 함량은 지방함량과 각각 유의한 정산관을 보였다. 5. 대두 단백질은 7.5% acrylamide gel 전기영동에 의해 품종에 따라 12~16개의 구성분으로 분리되었으며, 이들중 주구성분들은 상대이동도가 0.06(a), 0.14(b). 0.24(d) 이었고, 구성분 b의 함량이 품종간에 가장 변이가 컸으며, 구성분 b는 그밖의 주요 구성분들의 함량과 부의 상관이 있었고, 구성분 a는 단백질 함량과 정상관이 있었다. 6. 종실단백질 구성분들의 조합 특성 면에서 공시 86품종은 11개 유형군으로 분류되었으며, 우리나라와 일본품종은 미국품종에 비해 단백질구성분 조성이 훨씬 다양하였다. 7. 이동도가 매우 빠른 단백질 구성분 o(Rm 0.77) p(Rm 0.81)를 모두 갖고 있는 품종은 3품종, 모두 갖고 있지 않은 품종은 1품종이었고, 나머지 82품종은 o나 p중 한 구성분을 갖고 있었으며 그 분포율은 30 : 65 이었는데 미국계 품종은 우리나라 품종에 비해 구성분 o를 간고 있는 비율이 현저히 적었다. 8. 대두 종실은 개화후 22일까지 완만히, 그 이후 20~30일간 급속히

  • PDF

Improving the Design-phased VE Process of Public Clients in Relation to Using Critical Success Factors (핵심성공요인과 연계한 공공발주기관의 설계VE 프로세스 개선에 관한 연구)

  • Park, Heedae;Han, Seung Heon;Kim, Sung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3D
    • /
    • pp.399-408
    • /
    • 2009
  • The major changes in construction environment are that construction project is bigger and more complicated and the power of construction market changes from the supplier to the client or the user. Especially public construction enterprises have advanced to introduce the value engineering (VE) which is one of the cost management based on the owner's leading at the design phase for economical efficiency and quality improvement. According to the these efforts, the implementation of VE was legislated in the revised Construction Technology Management Act in 2000, governmental agencies, local autonomies, and construction public enterprises universally has taken the VE into consideration. In this circumstance, the scope that VE construction applied at 50 billion won projects from 2003 has been extended to 10 billion won projects in 2006. Therefore, the VE construction will be activated in the future. The cost savings and function improvement, which are the purpose of VE are not only construction public enterprises, but also every public client supported from government's budget or owned by the government. Therefore, the purpose of this study is to propose the improved process and performance index of VE for governmental agencies, local autonomies, and construction public enterprises which want to introduce or improve the VE process. This research also suggested the To-be design-phased VE process model. In addition, it suggested the To-be model of design management reflected the To-be design-phased VE process model, which is eliminated two problems reflected for the performance improvement of the As-is model of design management.

Climatic Yield Potential Changes Under Climate Change over Korean Peninsula Using 1-km High Resolution SSP-RCP Scenarios (고해상도(1km) SSP-RCP시나리오 기반 한반도의 벼 기후생산력지수 변화 전망)

  • Sera Jo;Yong-Seok Kim;Jina Hur;Joonlee Lee;Eung-Sup Kim;Kyo-Moon Shim;Mingu Kang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.4
    • /
    • pp.284-301
    • /
    • 2023
  • The changes in rice climatic yield potential (CYP) across the Korean Peninsula are evaluated based on the new climate change scenario produced by the National Institute of Agricultural Sciences with 18 ensemble members at 1 km resolution under a Shared Socioeconomic Pathway (SSP) and Representative Concentration Pathways (RCP) emission scenarios. To overcome the data availability, we utilize solar radiation f or CYP instead of sunshine duration which is relatively uncommon in the climate prediction f ield. The result show that maximum CYP(CYPmax) decreased, and the optimal heading date is progressively delayed under warmer temperature conditions compared to the current climate. This trend is particularly pronounced in the SSP5-85 scenario, indicating faster warming, except for the northeastern mountainous regions of North Korea. This shows the benef its of lower emission scenarios and pursuing more efforts to limit greenhouse gas emissions. On the other hand, the CYPmax shows a wide range of feasible futures, which shows inherent uncertainties in f uture climate projections and the risks when analyzing a single model or a small number of model results, highlighting the importance of the ensemble approach. The f indings of this study on changes in rice productivity and uncertainties in temperature and solar radiation during the 21st century, based on climate change scenarios, hold value as f undamental information for climate change adaptation efforts.

Reducing the Test Time for Chemical/Mechanical Durability of Polymer Electrolyte Membrane Fuel Cells (고분자연료전지의 화학적/기계적 내구성 평가 시간 단축)

  • Sohyeong Oh;Donggeun Yoo;Kim Myeonghwan;Park Jiyong;Choi Yeongjin;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.517-522
    • /
    • 2023
  • A chemical/mechanical durability test of polymer membrane evaluation method is used in which air and hydrogen are supplied to the proton exchange membrane fuel cell (PEMFC) and wet/dry is repeated in the open circuit voltage (OCV) state. In this protocol, when wet/dry is repeated, voltage increase/decrease is repeated, resulting in electrode degradation. When the membrane durability is excellent, the number of voltage changes increases and the evaluation is terminated due to electrode degradation, which may cause a problem that the original purpose of membrane durability evaluation cannot be performed. In this study, the same protocol as the department of energy (DOE) was used, but oxygen was used instead of air as the cathode gas, and the wet/dry time and flow rate were also increased to increase the chemical/mechanical degradation rate of the membrane, thereby shortening the durability evaluation time of the membrane to improve these problems. The durability test of the Nafion 211 membrane electrode assembly (MEA) was completed after 2,300 cycles by increasing the acceleration by 2.6 times using oxygen instead of air. This protocol also accelerated degradation of the membrane and accelerated degradation of the electrode catalyst, which also had the advantage of simultaneously evaluating the durability of the membrane and the electrode.

Comparative Analysis of Blue Carbon Stock Spatial Data in the Estuaries and Coastal Areas of the Geum and Nakdong Rivers (금강 및 낙동강 하구·연안의 블루카본 저장량 공간정보 비교)

  • Ji-Ae Jung;Bong-Oh Kwon;Hyun-Jung Hong;Jong-Ho Ahn;Moung-Jin Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1505-1515
    • /
    • 2023
  • As extreme weather events caused by climate change are occurring around the world, blue carbon has recently been gaining attention as a carbon sink. Blue carbon has been officially recognized by the Intergovernmental Panel on Climate Change (IPCC) as a means of reducing greenhouse gases, and various studies are underway to discover new blue carbon sources both domestically and internationally. Domestic blue carbon research is centered on carbon absorption and storage in tidal flats, which account for most of the coastal wetlands, but there is a lack of research on spatial information. This study utilized the carbon storage of tidal flats from previous studies and converted it into location and spatial information for each basin of the Geumgang and Nakdong rivers. In addition, a proxy value of carbon storage per area by basin was calculated to compare and analyze the total carbon storage of various tidal flats in Korea and abroad. As a result of the analysis, both the Geumgang and Nakdong River basins showed different amounts of carbon storage depending on the tidal flats data, with the highest amount in the Geumgang basin coming from the National Ocean Survey (469,810.1 Mg C) and the highest amount in the Nakdong River basin coming from the Ministry of Environment (217,145.01 Mg C). The results of this study can be used as a basis for future research on the establishment of domestic blue carbon spatial information.

Study on Enhancement of Ammonia Generation for Effective Collision Frequency (유효충돌빈도를 고려한 암모니아 생성 증대기법 연구)

  • Sejin Kim;Yongseok CHoi;Hyunchul Park
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2023
  • Research, such as developing alternative energy in the transportation field, including aviation, is being actively conducted to solve the issue of current climate change. Interest in ammonia fuel as a carbon free energy (CFE) source is increasing due to the ease of liquefaction and transportation and similarity in energy density to that of methanol. However, explosiveness and toxicity of ammonia make it difficult to handle. Therefore, in this study, stable ammonia production was attempted using relatively easy-to-handle urea water solution (UWS). High temperature steam was used to promote the hydrolysis of ammonia. In order to determine the causes for ammonia production below the theoretical equivalent ratio, it was suggested that there were not enough collisions to promote the hydrolysis based on the kinetic theory of gases. The hydrolysis of unreacted isocyanic acid (HNCO) was tested according to the change in water supply. As a result, an increased amount of ammonia produced was confirmed. The increased amount of ammonia produced in a certain section was dependent on the steam temperature and the flow rate of water supplied.

Application of CFD Methods to Improve Performance of Denitrification Facility (탈질 설비의 성능 개선을 위한 CFD 기법 적용에 관한 연구)

  • Min-Kyu Kim;Hee-Taeg Chung
    • Clean Technology
    • /
    • v.29 no.4
    • /
    • pp.305-312
    • /
    • 2023
  • Due to the strengthening of environmental requirements, aging denitrification facilities need to improve their performance. The present study aims to suggest the possibility of improving performance using computational analysis techniques. This involved modifying both the geometric design and the operating conditions, including the flow path shape of the equipment such as the inlet guide vane and the curved diffusing part, and the flow control of the ammonia injection nozzle. The conditions presented in this study were compared with existing operating conditions in terms of the flow uniformity, the NH3/NO molar ratio of the mixed gas flowing into the catalyst layer, and the total pressure drop of the facility. The flow field applied in the computational analysis ranged from the outlet of the economizer in the combustion furnace to the inlet of the air preheater, the full domain of the denitrification facility. The performances were derived by solving the flow fields using ANSYS-Fluent and the injection amount of ammonia was adjusted for each nozzle using Design Xplorer. Compared to the denitrification performances of the equipment currently in operation, the conditions proposed in this study showed an improvement in the flow uniformity and NH3/NO composition ratio by 45.1% and 8.7%, respectively, but the total pressure drop increased by 1.24%.