• Title/Summary/Keyword: 가스 부하

Search Result 1,773, Processing Time 0.034 seconds

A Proposal of Sequencing the Combined Processes for Resources Recovery and Nitrogen Removal from Piggery Waste (슬러리형 돈사폐수에서 자원회수와 질소제거를 위한 순차적 결합공정 제안)

  • Hwang, In-Su;Min, Kyung-Sok;Bae, Jin-Yeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.61-66
    • /
    • 2006
  • The combined ADEPT(Anaerobic Digestion Elutriated Phased Treatment)-SHARON(Single reactor system for High Ammonium Removal Over nitrite)-ANAMMOX(Anaerobic ammonium oxidation) processes were operated for resources recovery and nitrogen removal from slurry-type piggery waste. The ADEPT process operated at an acidogenic loading rates of 3.95 gSCOD/L-day, the SCOD elutriation rate and acid production rate were 5.3 gSCOD/L-day and 3.3 gVFAs(as COD)/L-day, respectively. VS reduction and SCOD reduction by the hydrolysis were 13% and 0.19 $gSCOD_{prod.}/gVS_{feeding}$, respcetively. Also, the acid production rate was 0.80 $gVFAs/gSCOD_{prod}$. In methanogenic reactor, the gas production rate and methane content were 2.8 L/day($0.3m^3CH_4/kgCOD_{removal}@STP$) and 77%, respectively. With these operating condition, the removals of nitrogen and phosphorus were 94.1% as $NH_4-N$(86.5% as TKN) and 87.3% as T-P respectively.

Effect of aeration on the physicochemical characteristics of livestock feces compost during composting period (퇴비화과정 중 공기공급 여부가 가축분뇨 퇴비의 물리화학적 특성에 미치는 영향)

  • Jeong, Kwang-Hwa;Kang, Ho;Kim, Tai-ll;Park, Chi-Ho;Yang, Chang-Buem
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.4
    • /
    • pp.57-65
    • /
    • 2003
  • Livestock farming is one of several industries that have faced criticism because of its impact on the water quality, soil contamination and air pollution. The livestock feces can cause some environmental problems. The best way to treat the feces is to recycle the manure as an organic fertilizer after fermentation or composting. This study was carried out to investigate the characteristics of composting of manure in several composting conditions. The variations of physicochemical characteristics of each compost piles containing different level of air volume were analyzed throughout the composting period. In this study, pigs manure compost piles mixed with saw dust were composted in 110L of laboratory scale plastic vessels and $1.5m^3$ of small cubic wooden composting vessels for 60days. The compost piles were ventilated continuously with air pump throughout the composting duration. The air volume ventilated into the piles was regulated by chock valve attached to the inlet pipe. The ventilation level was adjusted by 20, 50, 100, 150 and $200L/m^3/mim$, respectively. The highest temperature of the compost increased to $72^{\circ}C$ during composting period. After 20days from beginning of fermentation, concentrations of $H_2S$, $CH_3SH$, DMS and DMDS generated from compost piles were 29, 16, 6 and 5ppb in blow in state compost pile, conversely, in blow out state compost pile, the parameters were 32, 24, 15 and 14ppb, respectively.

  • PDF

Atmospheric Acid Deposition : Nitrogen Saturation of Forests (대기 산성 강하물 : 삼림의 질소 포화)

  • Kim, Joon-Ho
    • Journal of Ecology and Environment
    • /
    • v.29 no.3
    • /
    • pp.305-321
    • /
    • 2006
  • Atmospheric Acid Deposition: Nitrogen Saturation of Forests: Volume weighted annual average wet deposition of nitroge at 33 sites in Korea during 1999-2004 ranged 7.28 to $21.05kgN{\cdot}ha^{-1}{\cdot}yr^{-1}$ with average $12.78kgN{\cdot}ha^{-1}{\cdot}yr^{-1}$, which values are similar level with nitrogen deposition of Europe and North America. The temperate forests that suffered long-term high atmospheric nitrogen deposition are gradually saturated with nitrogen. Such nitrogen saturated forest watersheds usually leach nitrate ion ($NO_3^-$) in stream water and soil solution. It may be likely that Korean forest ecosystems are saturated by much nitrogen deposition. In leaves with nitrogen saturation ratios of N/P, N/K and N/Mg are so enhanced that mineral nutrient system is disturbed, suffered easily frost damage and blight disease, reduced fine-root vitality and mycorrhizal activity. Consequently nitrogen saturated forests decrease primary productivity and finally become forest decline. Futhermore understory species are replaced the nitrophobous species by the nitrophilous one. In soil with nitrogen saturation uptake of methane ($CH_4$) is reduced and emission of nitrogen monoxide (NO) and nitrous oxide ($N_{2}O$) are increased, which gases are greenhouse gas accelerating global warming.

Human-Powered Generator designed for Sustainable Driving (고출력 지속이 가능한 인체 구동 방식의 자가 발전기 개발)

  • Lim, Yoon-Ho;Yang, Yoonseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.7
    • /
    • pp.135-142
    • /
    • 2015
  • Human-powered self-generating devices have been attractive with its operation characteristic independent from outer environment such as weather condition and wind speed. However, conventional self-generators have low electric power output due to their weakly-coupled electromagnetic structure. More importantly, rotary crank motion which is usually adopted by conventional self-generator to generate electricity requires specific skeletal muscles to maintain large torque circular motion and consequently, causes fatigue on those muscles before it can generate enough amount of electricity for any practical application. Without improvement in electric power output and usability, the human-powered self-generator could not be used in everyday life. This study aims to develop a human-powered self-generator which realized a strong electromagnetic coupling in a closed-loop tubular structure (hula-hoop shape) for easy and steady long-term driving as well as larger electric output. The performance and usability of the developed human-powered generator is verified through experimental comparison with a commercial one. Additionally, human workload which is a key element of a human-powered generator but not often considered elsewhere, is estimated based on metabolic energy expenditure measured respiratory gas analyzer. Further study will focus on output and portability enhancement, which can contribute to the continuous power supply of mobile equipments.

A study on the arrangement of integrated power system for warship (함정의 통합 전력시스템 구성에 관한 연구)

  • Baek, Hyun-Min;Jung, Kyun-Sik;Lee, Myung-Ho;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1070-1074
    • /
    • 2014
  • According to IEEE 1662(2009), IPS is a power system where all prime movers produce electrical power that is shared among propulsion, mission, and ship service loads. Discriminating attributes of integrated power systems are flexibility of movers' arrangements, mechanical decoupling between prime movers and propulsors, an increased level of energy conversion and transmission redundancy, and flexibility of redistributing available electrical power for future electronic weapons. IPS could have various steps of power that can be produced at optimal load of movers. In this study, an evaluation method for optimal arrangement of movers was investigated when an IPS warship is projected. The two factors are utilized for the quantitative analysis which are the weight of system as the fighting power and the fuel consumption per year as the economic feasibility. And also the ways for arrangement of system were studied according to existence of small diesel generator. The evaluation method that decides the optimization level is based on the DEA(Data Envelopment Analysis)

Fundamental Heat Analysis about the Thermoelectric Generation System Using the Waste Heat of Exhaust Gas from Ship (선박의 배기가스 폐열을 활용한 열전발전시스템에 관한 기초 열해석)

  • Kim, Myoung-Jun;Ga, Gwang-Jin;Chea, Gyu-Hoon;Kim, In-Seup
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.583-592
    • /
    • 2016
  • IMO (International Maritime Organization) in the UN (United Nations) set up that aim at reducing $CO_2$ emission from ship by up to 30 percent until 2030. The final purpose of this study is the development of marine thermoelectric generation system using waste heat from vessel of internal combustion engines. Before the development of marine thermoelectric generation system, this paper carried out the fundamental heat analysis of marine thermoelectric generation system. It was able to obtain the valuable results about the efficiency improvement of the thermoelectric generation system. The results is as follows : 1) It was confirmed that the efficiency of thermoelectric generation system improves to 8.917 % with increasing the temperature difference of peltier module by reducing the temperature difference between peltier module and heat source at the hot side. 2) System efficiency according to change in the external load resistance was confirmed that the change width of about 6 % which does not significantly occur. 3) System efficiency in the case stainless steel at the same condition is 8.707 %. System efficiency could be confirmed that the stainless steel is higher than duralumin (8.605 %), copper (8.607 %).

The syudy of reaction kinetics in the thermophilic aerobic digestion process of piggery wastewater (축산폐수의 고온호기성 소화공정에서의 반응동력학 연구)

  • Kim, Yong-Kwan;Kim, Seok-Won;Kim, Baek-Jae
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.97-102
    • /
    • 2007
  • The piggery wastewater is the major source of the water pollution problem in the rural area. The treatment alternatives for piggery wastewater are limited by the characteristics of both high organic and nitrogen(N) content. In order to investigate an efficient N removal system, the thermophilic aerobic digestion process was examined. The experiment was investigated organic and nitrogen removal efficiency at various HRTs and air supply volume. The results of semi-continuous experiment indicated that a higher removal of the soluble portion of COD was achieved with the longer HRTs. However, the inert portion of COD in piggery wastewater was not much changed by thermophilic aerobic digestion. In addition, with the higher HRT of 3 days, up to 79% of NH4-N removal efficiency was achieved. Lower the HRTs, a decrease of NH4-N removal was founds. The gas samples from the lab reactor were analyzed along with the N content in influent and effluent. The N2O formation in our system indicates a novel aerobic deammonification process occurred during the thermophilic aerobic digestion. Both N02 and N03 were not presented in the effluent of thermophilic aerobic digester. With the HRT of 3 days, 36.4% of influent N(or 57.5% removal N) was aerobically converted to N2O gas. The ammonium conversion to N2O gas significantly decrease to 4.5% at low HRT of .05 day..

  • PDF

A Prospective Study for Risk Factors Predicting Postoperative Pulmonary Complications (수술 후 폐 합병증 발생의 위험 인자에 대한 연구)

  • Chon, Su Yeon;Kim, Yu Jin;Kyung, Sun Young;Ahn, Chang Hyeok;Lee, Sang Pyo;Park, Jeong Woong;Jeong, Sung Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.6
    • /
    • pp.516-522
    • /
    • 2007
  • Background: Postoperative pulmonary complications are important problems that prolong the length of the hospital stay and increase patient mortality. However, our knowledge of the postoperative factors that increase the risk of these complications is less than complete. Methods: We conducted a prospective study to determine the risk factors for postoperative pulmonary complications. A total of 199 patients were referred to the Pulmonology Department for preoperative pulmonary evaluation. We reviewed the perioperative variables according to the National Surgical Quality Improvement Program (NSQIP). Postoperatively, we collected data on the occurrence of postoperative pulmonary complications and we evaluated the relationship between the perioperative variables and outcomes. Results: Twenty two patients (11%) had pulmonary complications; 6 had respiratory failure, 4 had pneumonia, 13 had pleural effusion and, 2 had atelectasis. Five variables were statistically significantly associated with pulmonary complications on the bivariate analyses. Multiple logistic regression analyses revealed that three of these variables were independently associated with an increased risk of pulmonary complications; a high cardiac risk index (OR 16.5, p=0.002), emergency surgery (OR 10.3, p=0.017), and thoracic/abdominal surgery (OR 3.8, p=0.047). Conclusion: The risk factors for postoperative pulmonary complications are a high cardiac risk index, emergency surgery and thoracic/abdominal surgery.

Relationships of TVOC with Several Aromatic Hydrocarbon Constituents at Preschool Facilities

  • Yoon, Chung-Sik;Choi, In-Ja;Ha, Kwon-Chul;Park, Dong-Uk;Park, Doo-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.404-411
    • /
    • 2006
  • 이 연구의 목적은 유치원에서 총 휘발성 유기화합물의 농도를 평가하고, 총 휘발성 유기화합물 농도와 대표적인 8개 방향족 화합물의 상관관계를 조사하는데 있다. 도시에 위치한 11개 유치원의 실내와 실외에서 각각 30개, 11개의 지역시료를, 시골에 위치한 4개 유치원에서는 각각 10개, 4개의 시료를 테낙스 튜브를 이용하여 오전에 1-2시간 채취하였다. 채취한 시료는 열탈착하여 가스크로마토그래피-질량분석기로 분석하였다. 13가지 물질을 각각의 표준물질로 개별 정량하여 이중 빈번히 발견되는 8가지 방향족 유기화합물은 상관관계 평가에 사용하였다. 총 휘발성 유기화합물은 톨루엔을 기준으로 정량하였다. 도시에 위치한 유치원 실내의 총 휘발성 유기화합물 농도가 높았고, 조사 건수의 50%가 환경부 및 교육인적자원부의 가이드라인($400{\mu}g/m^{3}$)을 초과하였다. 도시지역의 유치원 실내 및 실외의 기하평균은 각각 $387.9{\mu}g/m^{3}$$134.9{\mu}g/m^{3}$이었고, 시골지역 유치원에서는 각각 $189.6{\mu}g/m^{3},;74.4{\mu}g/m^{3}$이었다. 톨루엔, 크실렌, 에틸벤젠, 정량한 유기 화합물 총합, 총 휘발성 유기화합물은 기하정규분포를 하였다. 벤젠, 톨루엔, 에틸벤젠, 크실렌(BTEX)은 도시에 위치한 유치원에서 농도도 높고, 총 휘발성 유기화합물중 함량도 높았고, 시골지역에서는 농도와 상대적 함량이 낮았다. 도시지역에서는 총 휘발성 유기화합물 중 BTEX의 비중이 25.2%였고 정량한 13가지 유기화합물 중에서는 35.6%를 차지하였다. BTEX 각각 개별물질은 미국 환경보호청이 제시하는 일일 노출 기준량(Reference Concentration; RfC) 보다는 현저히 낮았다. 총 휘발성 유기화합물읜 농도는 실내가 실외 보다 높았다(I/O ratio 2.5). BTEX의 상대적 함량도 실내가 실외보다 높아 실내에도 발생원이 있음을 암시하고 있다. 자료 분석결과 유치원 실내의 벤젠은 실외로부터 유입되고 있었고, 톨루엔, 에틸벤젠, 크실렌은 실외뿐 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.

Maximum Power Point Tracking Method Without Input side Voltage and current Sensor of DC-DC Converter for Thermoelectric Generation (열전발전을 위한 DC-DC Converter의 입력측 전압·전류 센서없는 최대전력점 추적방식)

  • Kim, Tae-Kyung;Park, Dae-Su;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.569-575
    • /
    • 2020
  • Recently, research on renewable energy technologies has come into the spotlight due to rising concerns over the depletion of fossil fuels and greenhouse gas emissions. Demand for portable electronic and wearable devices is increasing, and electronic devices are becoming smaller. Energy harvesting is a technology for overcoming limitations such as battery size and usage time. In this paper, the V-I characteristic curve and internal resistance of thermal electric devices were analyzed, and MPPT control methods were compared. The Perturbation and Observation (P&O) control method is economically inefficient because two sensors are required to measure the voltage and current of a Thermoelectric Generator(TEG). Therefore, this paper proposes a new MPPT control method that tracks MPP using only one sensor for the regulation of the output voltage. The proposed MPPT control method uses the relationship between the output voltage of the load and the duty ratio. Control is done by periodically sampling the output voltage of the DC-DC converter to increase or decrease the duty ratio to find the optimal duty ratio and maintain the MPP. A DC-DC converter was designed using a cascaded boost-buck converter, which has a two-switch topology. The proposed MPPT control method was verified by simulations using PSIM, and the results show that a voltage, current, and power of V=4.2 V, I=2.5 A, and P=10.5 W were obtained at the MPP from the V-I characteristic curve of the TEG.