• Title/Summary/Keyword: 가스 냉방

Search Result 95, Processing Time 0.023 seconds

Effect on Household Absorption Chiller by the Supply of the Cooling Water (냉각수 보급이 가정용 흡수식 냉난방기의 성능에 미치는 영향)

  • 이호생;김동휘;최병권;김재돌;윤정인
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.267-272
    • /
    • 2002
  • The electric heat pump requiring HCFCs as a refrigerant has been for most residential air-conditioners in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes a serious problem to the global environment such as global warming and ozone layer destruction. An absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the absorption chiller/heater. Experiment was done with a 1.5RT household absorption chiller and heater. It was experimented that the cooling capacity, gas capacity, COP were researched by the temperature of cooling water. The change of the cooling water temperature have effect the temperature(or pressure) of the parts on absorption chiller The result of the change of the cooling water temperature have the effects of the absorption chillers. This data will help to operate the household absorption chiller and heater.

  • PDF

Dynamics modeling of a GHP in cooling mode for development of control algorithm (제어 알고리즘 개발을 위한 GHP 냉방모드 동특성 모델링)

  • Shin Younggy;Kim Young Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.243-249
    • /
    • 2005
  • The present study has been conducted to simulate dynamics of a gas engine-driven heat pump(GHP) for design of control algorithm. The dynamic modeling of a GHP was based on conservation laws of mass and energy. For automatic control of refrigerant pressures, actuators such as engine speed, outdoor fan, coolant three-way valves and liquid injection valve were PI or P controlled. The simulation results showed physical behavior that is realistic enough to apply for control algorithm design.

A Study on Reduction of Air Conditioning Energy Consumption by Surface Albedo Variation Using Meteorological Model (기상모델을 이용한 지표면 반사능에 따른 냉방에너지 소비 저감 연구)

  • AN, Jae-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.16-24
    • /
    • 2010
  • Recently environmental regulations like the Kyoto Protocol, adopted in 1997, required the 5.2% reduction of the greenhouse gas emission in 1990. And 13th General Assembly in 2007, held in Bali of India, have agreed to duty reduction even in developing countries in 2013. Korean government needs the researches on climate change and the strategic programs for greenhouse gas reduction. In this paper Colorado State University Mesoscale Model(CSU-MM) was applied to simulate the relationship between surface albedo and air temperature. Meteorological model simulation in region of Ansan-City, Shiheung-City showed that mean air temperature became lower with the increase of albedo value. Simulated air temperature became lower $-0.16^{\circ}C$ and $-0.66^{\circ}C$ by 5% and 20% increase of albedo values respectively. And cooling energy saving amount in air conditioning process was calculated according to lowered air temperature. The reduction of air temperature resulted the reduction of air conditioning energy in personal house and commercial buildings. The increase of albedo from 5% to 20% resulted the reduction of air conditioning energy from 44,493 MWh/yr to 183,796 MWh/yr. Additionally the reduction of greenhouse gas emission through the energy saving was calculated after IPCC guideline. In terms of greenhouse gas emission $CO_2$ was reduced form -30,414 ton-$CO_2$/yr to -125,638 ton-$CO_2$/yr according to the reduction of electric energy.

에어컨용 냉매압축기

  • 이승갑;소순갑;최영민
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.11
    • /
    • pp.8-14
    • /
    • 2002
  • 가정용 룸에어컨이나 가정, 점포, 사무실에 사용하는 패키지에어컨은 쾌적한 주거 사무공간을 실현할 수 있기 때문에 최근 10년 동안에 광범위하게 보급되었고, 그 기술도 해마다 진보하고 있다. 그림 1에서 나타나듯이 2001년 가정용 룸에어컨의 국내생산 수량은 연간 600만대 수준이며, 패키지에어컨은 연간 약 80만대 수준이다. 2001년 기준으로 에어컨의 국내시장규모는 약 130만대로 세대 보급률이 약 40%에 도달하고 있다. 비록 패키지에어컨은 생산 수량면에서는 룸에어컨과 비교할 수 없지만, 한대의 냉방능력이 룸에어컨의 수배에서 수십배로 크기 때문에 전력에너지소비, 환경 등에 미치는 영향은 룸에어컨과 비견될 수 있다. 공조장치 보급에 따른 환경, 에너지 측면에서의 사회적 영향과 관심이 점차 커지고 있고, 이것을 개선하기 위한 기술개발이 활발하게 진행되고 있다. 에어컨을 포함한 공조장치의 다수는 효율이 좋은 증기 압축식 냉동사이클로써 구성되어 있으며, 증기 압축식 사이클에서 냉매가스를 압축하여 순환시키는 심장역할을 하고 있는 것이 압축기이다. 또한 압축기는 공조장치 전체의 전력소비의 80%에서 90%을 차지하고 있어 에너지절감 기술개발과 환경기술개발의 포인트가 되는 기구이다. 최근에 에어컨용 냉매압축기의 기술적인 개발동향을 정리하면 다음과 같은 경향으로 진행되고 있다. (1)오존층 파괴 지수가 제로인 친환경 HFC계와 자연냉매용 밀폐형 압축기기술 (2)로터리압축기의 성능향상 및 대용량화 기술 (3)압축기용 모터의 DC화통에 의한 모터 효율 향상 및 압축기 효율 향상 기술 (4)스크롤압축기의 압축비 변화의 대응, 고효율 유지, 대용량화 등 성능향상기술 (5)로터리, 스크롤, 왕복동 압축기를 이용한 용량가변기술 본 논고에서는 룸에어컨과 패키지에어컨에서 사용되고 있는 밀폐형 압축기에 대해서 그림 2에서 나타내고 있는 냉방능력 10tons(120,000Btu/h) 이하를 중심으로 상기의 최근 기술 동향을 간략하게 소개하고자 한다.

  • PDF

Energy Economic Analysis of Standard Rural House Model with PV System (PV 시스템이 적용된 농어촌 주택 표준모델의 에너지 경제성 분석)

  • Lee, Chan Kyu;Kim, Woo Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1540-1547
    • /
    • 2013
  • The energy economic analysis of the standard rural house model with PV system was performed based on annual energy demand calculation using the EnergyPlus to contribute in reducing building energy which occupies 25% of national energy consumption and in developing a low-energy & eco-friendly house model. Two types of PV system installation was considered to cover electricity demand for cooling, electric, and heating devices. For the selected house model, heating energy demand is 7 times higher than cooling energy demand. For the Case1, it is favorable to use electricity from PV system for cooling and electric devices and to sell surplus electricity. For the Case2, it is favorable to use electricity from PV system for cooling, electricity and heating devices and to sell surplus electricity. Considering the installation cost of PV system and heat pump air conditioning system, the break-even point of Case1 and Case2 are about 13 and 11 years respectively. Although the installation cost of Case2 is more expensive, Case2 provides three times more profit than Case1 after the break-even point. Because the expected average life time of the selected PV system is 25 years, Case2 is more favorable option for the given standard rural house model.

A Study on Improvement of the Physical Properties of 4 Component Working Fluid in Gas Fired Absorption Chillers (가스흡수식 냉방기용 4성분계 작동매체의 물성 향상 연구)

  • Baek, Young-Soon;Oh, Young-Sam;Lee, Yong-Won;Park, Dal-Ryung;Koo, Ki-Kap
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.400-406
    • /
    • 1999
  • In an effort to obtain high efficiency in gas fired absorption chillers, a new working fluid has been developed with thc addition of the component of $LiNO_3$, LiCl and LiI to the conventional solution of $LiBr-H_2O$. The solubility and vapor pressure of the 4 component working fluid developed in this work were measured and compared to the results of $LiBr-H_2O$ solution. It was observed that there exists an optimal mole ratio of the inorganic salts in terms of solubility. The mole ratio of LiBr, $LiNO_3$ and LiCl was found to be around 5:1:1~2 in the $LiBr-LiNO_3-LiCl-H_2O$ mixture, and in the case of $LiBr-LiO_3-Lil-H_2O$ and $LiBr-Lil-LiCl-H_2O$ mixtures, the mole ratio of LiBr, $LiNO_3$ and Lil/ LiBr, LiI and LiCl were found to be around 5:1:1 and 5:1:0.5~1 respectively. The vapor pressure of the 4 component working fluid of the optimal mole ratio was increascd with adding the component of $LiNO_3$, LiCl and LiI except for $LiBr-LiNO_3-LiCl-H_2O$ mixture. The absorption capacity of $LiBr-LiNO_3-LiCl-H_2O$ mixture was obtained higher than that of $LiBr-H_2O$ mixture.

  • PDF

Greenhouse Gas Mitigation Effect Analysis by Cool Biz and Warm Biz (쿨맵시 및 온맵시 복장 착용에 의한 온실가스 감축 효과 분석)

  • Yeo, So-Young;Ryu, Ji-Yeon;Lee, Sue-Been;Kim, Dai-Gon;Hong, Yoo-Deog;Seong, Mi-Ae;Lee, Kyoung-Mi
    • Journal of Climate Change Research
    • /
    • v.2 no.2
    • /
    • pp.93-106
    • /
    • 2011
  • Republic of Korea officially announced its mid term reduction target which reduce about 30% of BAU GHG emission by 2020 in the 15th meeting of UNFCCC(COP 15) held in Copenhagen, Denmark 2009. To achieve this goal, it is necessary to understand the serious of climate change and take part in GHG reduction not only industry but also the nation. However, such positive participation in green life which may cause inconvenient of the life of the people. It should be accomplished with providing reliable information. This study suggests the scientific potentialities of GHG emission by guideline on low carbon life and green life to form and change a lifestyle suitable for coping with climate change. And also, this study quantitate the GHG reduction which may reduce demand for air conditioning by cool biz and warm biz. In Korea, this campaign has become known as 'CoolMaebsi' by Ministry of Environmental of Korea. 'CoolMaebsi' is a compound word of 'Cool' which means feel refreshed, and 'Maebsi' is a Korean word which means attire. Though this campaign is effective and significant to reduce the GHG emission yet there were no study on quantitative analysis. Therefore this study calculated reduced energy consumption and potential GHG emission by measuring variation of skin temperature. As the result, wearing warm biz and cool biz have an effect of reducing not only the energy consumption but also GHG emission. To achieve the low carbon society, it is necessary to improve the energy saving system and introduce the policy which guide to change a life style.

The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital buildings (대형병원에서 마이크로터빈 이용한 열병합시스템 에너지성능 및 경제성 분석)

  • Kim, Byung-Soo;Gil, Young-Wok;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.176-183
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat, and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30[%] after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40[%]. If electricity energy and waste heat in turbine are used, 56[%] of heating energy and 67[%] of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70[%].

Development of an Integrated Meter Reading Home Concentrate Device (통합 원격검침 지시장치 개발)

  • Park, Jae-Sam
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • This paper highlights the home concentrate device(HCD) that integrates the data reading and display of the six types of meters (water, hot water, heating, cooling, gas and electricity) used in Korean residential areas. Unlike the conventional system which utilizes single MCU, the developed system uses two MCUs for one MCU to gather the meter readings and for the other MCU to communicate to the server computer. Hard ware design, communication protocols, LCD design and program structures are discussed and the test results are shown in this paper. With the implementation of integrated meter reading, the developed system can increase the popularity of automatic meter reading(AMR) with its better scalability, pricing, installation fee, maintenance and faster response.

A Survey on the Co-Generation Load for Large Commercial Buildings (대형상업건물의 열병합발전 부하조사)

  • 한승호;권순우;정상원;정재혁
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 1998
  • Energy consumption statistics have been surveyed for 50 large commercial buildings with high energy consumption records in Seoul City. The buildings were classified into three different groups for data analysis: hospitals, hotels, and department stores/office buildings. The analysis was focused on identifying installed boiler and refrigerator data, energy consumption rates, and energy load distribution throughout the year. Refrigerating electricity was confirmed again to affect most on the formation of the summer electricity load peak as expected. Replacing the refrigerator electricity peak in the summer with co-generation in large commercial buildings. However, overall heat load distribution in a single building is still considered not large enough for economically feasible co-generation and thus joint co-generation for multiple neighboring buildings are preferred and the Electric Power Law and LNG pricing policy should be revised favorably for co-generation in advance.

  • PDF