New Method for Estimating Gas Interchangeability for 13A Gas Appliances (13A 가스기기 새 가스호환성 판정법)

  • Ha, Young-Cheol;Park, Seo-Jong;Park, Won-Sic;Choi, Kyoung-Seok;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.961-967
    • /
    • 2011
  • The objective of this study was to develop a new method for estimating gas interchangeability for 13A gas appliances. The three basic principles for the development of this method are as follows: 1) to derive the secondary interchangeability factor that represents the effect of gas composition, in addition to the major interchangeability factor, i.e., Wobbe index; 2) to test every type of and each maker's domestic gas appliances that are widely used in our country, particularly including premixed gas appliances; and 3) to develop a simple estimation method. On the basis of these principles, thirty representative gas appliances were tested, and as a result, a simple two-dimensional interchangeability diagram consisting of Wobbe index and relative density was developed. Unlike conventional methods for estimating interchangeability, this method can be applied to premixed gas appliances, which have a narrow stable flame range, and the interchangeability range of this method then becomes narrower than that of the conventional methods.

A Study on the Combustion Characteristics of Fuel Gas and Their Interchangability (연료 가스의 연소특성 및 호환성에 관한 연구)

  • 김형택;이성룡
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.174-180
    • /
    • 1999
  • 본 연구는 여러 종류의 연소가스들의 연소 특성변수를 판단하여 각 가스들 간의 교체 가능성을 조사하는 것을 목적으로 하고 있다. 천연가스, 메탄가스, IGCC 생성가스의 연소특성, 즉 역화, 비화, 및 황염형성을 분제 버너를 이용하여 판단하였고, 실험 데이터는 연소 다이어그램 상에서 이론 공기량 분률과 입열로 표현하였다. 실험 결과, 메탄은 천연가스와 아무런 운전조건의 변화없이 호환가능하나, 천연가스를 IGCC 생성가스로 치환하고자 할 경우는 화염 안정으로 인하여 버너의 운전변수를 조절하여야만 한다. 이러한 연구결과는 다양한 산지에 따른 각종 천연가스들의 교체가능성 및 타 연료와의 호환가능성을 판단하는 기초자료로 사용될 수 있다.

  • PDF

Examination of validation for equivalent gas to replace natural gas (천연가스를 모사하는 등가가스의 유효성 검토)

  • Kim, Jong-Min;Lee, Seungro;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.128-135
    • /
    • 2013
  • In order to estimate the combustion characteristics and the gas interchangeability for natural gas with various compositions per each production area, equivalent gas are using to replace natural gas. It is known that an equivalent gas has the same the heating value, the compression factor, the relative density, CO emission and the burning velocity as the original natural gas. However, it is not reported that the flame shape and thermal efficiency and NOx emission by real gas appliance. In this study, equivalent gas was examined the validation to replace natural gas. The CO emission the burning velocity and the flame temperature were reconfirmed, and the flame shape, the NOx emission and the thermal efficiency were numerically and experimentally investigated. As results, there was not a large difference between natural gas and equivalent gas. This result demonstrated that there was no problem using equivalent gas to replace natural gas.

Estimation Method of the Interchangeability Using Equivalent Gases in a Partial Premixed Gas Appliance (등가가스를 이용한 부분예혼합 가스기기의 호환성 판정법)

  • Kim, Jong-Min;Lee, Seung-Ro;Ha, Young-Cheol;Lee, Sung-Min;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.761-766
    • /
    • 2010
  • The estimation method of the interchangeability in a partial premixed appliance about various compositions of natural gases using equivalent gases, experimentally. The results of the experiment in which equivalent gases were used compared with those obtained in experiments in which natural gases were used; Images of flames, lift-off limits, CO emissions, and incomplete combustion indices in KS standard for the domestic gas range were considered. From the comparison, it was observed that the length and color of the flame of the equivalent gases were almost the same as those of imported natural gases. Further, in the case of gases with Wobbe indices greater than 51 MJ/$m^3$, the KS standard for lifting limits was satisfied. Furthermore, in the case of gases with Wobbe indices less than 56.3 MJ/$m^3$, the CO mole fractions are in the range 95-100 ppm. Hence, the range of Wobbe indices 51-56.3 MJ/$m^3$ was proposed to be the range for interchangeability from the points of view of lifting limits and incomplete combustion, as prescribed in the domestic gas range in the case of imported natural gases.

A Study of Gas Interchangeability on Natural Gas and LPG/Air Mixture (천연가스와 LPG/Air 혼합시 가스 호환성 연구)

  • 한정옥;유현석;방효선
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.126-138
    • /
    • 1995
  • In order to study the gas interchangeability, a series of tests and analysis were conducted regarding to natural gas and gas mixture. Natural gas was selected as a reference and NG-LPG/Air mixture as a substitute gas. The major interest was placed on the determination of interchangeability limits for different mixing conditions. The parameters of Wobbe Index and Combustion Potential were employed in estimating the gas interchangeability, The limits obtained by analysis(AGA, WEAVER, KNOY, GILB) were compared with experimental results. The results estimated showed that the mixing limits of LPG/Air in proper conditions were found to vary with analysis and AGA is considered to be the most appropriate one.

  • PDF

Test Gases for Gas Burning Appliances of New Gas Group (새 가스그룹의 가스기기 시험가스)

  • Ha, Young-Cheol;Kim, Sung-Min;Lee, Chang-Eon;Choi, Kyoung-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.439-444
    • /
    • 2011
  • To determine the test gases for gas appliances of new gas group, the interrelation between gas interchangeability, including thermal efficiency, of 13A gas appliances and present 13A test gases was experimentally investigated. The test results show that the Wobbe indices in the case of incomplete combustion and the flame lifting limit gas for the new gas group are respectively 2% higher than the upper limit and 1% lower than the lower limit of the Wobbe index range. The most suitable composition of R gas is 96 mol% of methane and 4 mol% of propane; LNG could be also used as R gas. Further, analysis results showed that the hydrogen concentration of flash back limit gas could be lowered from 30 vol% to 23 vol%.

A Study on the Design and Development of Gas Burner for Gas Furnace (가스온풍기용 가스버너의 설계 및 개발에 관한 연구)

  • 박용호;염만오;심성훈;엄기훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.84-93
    • /
    • 1994
  • The purpose of this study is to modify the kerosene furnace, which is forced flue type with 15000kcal capacity, to gas furnace satisfying for CITY gas, LNG gas and LPG gas. The gas furnace, a kind of gas appliance, is mainly used for heating houses by combusion of gas. This paper describes briefly the design technology for gas burner which is most important in replacing kerosene fuel with gas fuel. Especially, the design for gas nozzle is constructed by theoretical and experimental method. It is found that the experimental results of the modified gas burner are good agreement with the theoretical results for calorific value and combustion efficiency. The result of this study will contribute in the design skill and of gas burner and similar gas appliance, and the pursuit for reduction of fuel cost as well as atmospheric pollution.

  • PDF