• Title/Summary/Keyword: 가스밸브

Search Result 418, Processing Time 0.024 seconds

Characteristics of Temperature Control by Hot-gas Bypass Flow Rate on Industrial Water Cooler (핫가스 바이패스 유량에 따른 산업용 냉각기의 온도제어 특성)

  • Baek, Seung-Moon;Choi, Jun-Hyuk;Byun, Jong-Yeong;Moon, Choon-Geun;Lee, Ho-Saeng;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1129-1136
    • /
    • 2009
  • The paper presents the performance characteristics for a cooling system using EEV. The water cooler was used to reduce thermal deformation and contraction due to high speed of machine tools and the EEV was used for capacity control for water cooler. The apparatus was designed for hot-gas bypass system which a hot-gas can flows from outlet of compressor to the inlet of evaporator. This experiment is the intermediary study for precise temperature control through PID control. The results show that the evaporator pressure increased and refrigeration capacity decreased as the EEV opening step of hot-gas bypass increased. These results can be used as basic data for the design of effective water cooler.

An Experimental Study on Detection of Gas Leakage Position by Monitoring Pressure Values at City Gas Pipeline (압력값 모니터링을 통한 배관 내 가스누출감지에 대한 실험적 연구)

  • Jin, Kyoung-Min;Choi, Gyu-Hong;Lee, Song-Kyu;Chung, Tae-Yong;Shin, Dong-Hoon;Hwang, Seung-Sik;Oh, Jeong-Seok
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.292-297
    • /
    • 2011
  • Gas pipeline safety management and risk prediction are recognized as a very important issue. And the effort to prevent accidents is essential. So, in this study, it was studied through correlation of pressure changes for leak point detection in real-time. It experimented by installing the five leakage valves in the pipe of 378 m and compared the actual leak points with simulation results. The results showed that experimental leak points and the actual leak points have differences within the 6 m. And this technology has to be commercialized by the demonstration in dangerous zone.

Performance analysis for load control of R744(carbon dioxide) transcritical refrigeration system using hot gas by-pass valve (핫가스 바이패스 밸브를 이용한 R744용 초임계 냉동사이클의 부하제어에 대한 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2189-2194
    • /
    • 2009
  • The automatic hot gas by-pass technique is applied to control the capacity of refrigeration and air-conditioning system when operating at part load. In the scheme, the hot gas from the compressor is extracted and injected into the outlet of an evaporator through a hot gas by-pass valve. Thus, In this paper, the hot gas by-pass scheme for CO2 is discussed and analyzed on the basis of mass and energy conservation law. A comparative study of the schemes is performed in terms of the coefficiency of performance (COP) and cooling capacity. The operating parameters considered in this study include compressor efficiency, superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : the superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.

Suggestion for Safety Improvement of Compressed Natural Gas Vehicle (압축천연가스 자동차의 안전성 향상을 위한 제언)

  • Kim, Young-Seob;Park, Kyo-Shik;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • Systematic safety research by Korea Government has been made to enhance the safety of CNG (compressed natural gas) vehicles since the burst of compressed cylinder of an urban bus in August 9, 2010. This article summarizes some major activities to ensure the safety of CNG vehicles, which covers review of regulation, safety management system including standard of inspection and certification, and training program of inspectors and car mechanics. Specifically, the followings were reviewed; type of CNG cylinder, location of CNG cylinder, material and type of fuel line and vent line, modification of pipeline connection, installation of gas detector, installation of emergency shutdown valve, installation of protecting cover for cylinder, obligations for CNG vehicle filling station. improving periodical inspection, routine test on gas vehicles, training program for engaged in gas vehicles, and designation of safety manager for CNG bus company. This paper suggests how to improve safety of CNG vehicles as a result of review of above mentioned check items.

Suggestion of Procurement Strategy with Commodity Classification by Peter Kraljic Matrix (피터 크랄직 매트릭스 기법에 의한 자재 분류를 활용한 구매 전략 제안)

  • Choi, Hyun Koo;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.11 no.3
    • /
    • pp.53-63
    • /
    • 2015
  • 구매자는 일반 제조업에서 자재를 피터 크랄직 매트릭스 기법에 의해 경쟁품목, 일반품목, 전략품목, 위험품목으로 분류한 후 각 품목 특성에 맞추어 구매 전략을 수립한다. 피터 클라직 매트릭스란 구매 리스크와 비즈니스 영향도 즉 특정 품목의 구매 금액 비중에 따라 자재를 분류하는 기법이다. 본 논문은 플랜트 엔지니어링산업에서 플랜트 기자재를 대상으로 피터 클라직 매트릭스 기법에 의해 기자재를 분류한 후 각 품목 특성에 맞는 구매 전략을 제안하고 사례 기업인 A사가 사우디아라비아에서 수행하는 발전 플랜트 기자재에 제안한 구매 전략을 적용하여 그 효과를 검증한 것이다. 플랜트 엔지니어링산업은 수주산업인데 총 수주금액 중 구매가 차지하는 비중은 약 50~60%이다. 따라서 프로젝트를 수행할 때 원가를 절감하여 이익을 극대화하기 위해 구매는 매우 중요한 역할을 한다. 플랜트 기자재는 크게 회전기계류, 고정장치류, 전기자재류, 제어자재류, 배관자재류로 구분된다. 각 공종별 플랜트 기자재에 대해 구매 지출 분석을 한 후 피터 클라직 매트릭스 기법에 의해 플랜트 기자재를 분류한 결과 경쟁품목에는 열교환기, 저장탱크 등이 포함되었고 일반품목에는 전선관, 조명기자재, 밸브 등이 포함되었다. 또한 전략품목에는 가스터빈, 가스터빈 흡입공기 냉각장치 등이 포함되었고, 위험품목에는 가스터빈 고정 볼트 등이 포함되었다. 경쟁품목 중 다관형 열교환기는 공급자와 공동으로 원가 모델을 구축하는 전략을 수립했고 저장탱크의 경우에는 공급자에게 원자재를 사급하는 전략을 수립하였다. 그 전략을 A사가 수행하는 프로젝트에 적용한 결과 각각 20%와 6%의 원가 절감 효과를 얻었다. 일반품목 중 전선관은 구매 대행사를 활용하는 전략을 수립했고 조명기자재는 기술 사양 검토 과정을 생략한 구매 프로세스 간소화 전략을 수립하였다. 그 결과 약 10%의 원가 절감과 평균 5일의 발주기간을 단축할 수 있었다. 전략품목 중 가스터빈 흡입공기 냉각장치는 공급자와 포괄적 양해각서를 체결하여 공동으로 사업주에 대응하는 전략을 수립했고 그 결과 프로젝트 수행 안정성 확보와 공급자 조기 참여를 통한 발주 스케줄 단축을 이룰 수 있었다. 위험품목 중 가스터빈 고정볼트는 재고 확보 전략을 수립하여 자재의 부족이나 파손으로 인해 프로젝트 공기에 영향을 주지 않도록 리스크를 감소시키는 효과를 얻었다.

  • PDF

Predicting and Preventing Damages from Gas Leaks at LPG Stations (LPG 충전소의 가스누출에 따른 피해예측 및 감소방안)

  • YANG-HO YANG;HA-SUNG KONG
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.577-585
    • /
    • 2023
  • This study applied ALOHA Program to predict the damage caused by fire and explosion predicted to occur from gas leakage at LPG stations and presented plans to prevent damages by diagramming the impact range and distance. The propane gas leakage from LPG stations causes human damage like breathing issues and property damage, including building destruction to residents in the surrounding areas. As a way to reduce this, first, the hazardous substance safety manager of the LPG station needs to check frequently whether the meters and safety valves are working properly to prevent leakage in advance. Second, the LPG stations' storage tanks should be worked by the person who received "hazardous substance safety manager training" under the provisions of the Act on the Safety Control of Hazardous Substances and has been appointed as a "hazardous substance safety manager" by the fire department. Third, LPG station's various safety device functions, such as overfill prevention devices, must be checked on a regular basis. Finally, wearing work clothes and shoes that prevent static electricity at LPG stations is highly recommended, as static can cause a fire when gas leaks.

Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant (BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책)

  • Woo, In-Sung;Lee, Joong-Hee;Lee, In-Bok;Chon, Young-Woo;Park, Hee-Chul;Hwang, Seong-Min;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • For a methanol separation column of the BPA (Bisphenol A) plant, HAZOP (hazard and operability) assessment was performed and damage ranges were predicted from the accident scenarios for the fire and the explosion. As a result, the damage range of the jet fire was 20 m in the case of rupture of the discharge pipe (50 mm diameter) of safety valve, and that of the flash fire was 267 m in the case of catastrophic rupture. Also, the damage ranges of the unconfined vapor cloud explosion (UVCE) for the rupture of the discharge pipe and for the catastrophic rupture were 22 m and 542 m, respectively. For the worst case of release scenarios, safety measures were suggested as follows: the pressure instruments, which can detect abnormal rise of the internal pressure in the methanol separation column, should be installed by the 2 out of 3 voting method in the top section of the column. Through the detection, the instruments should simultaneously shut down the control and the emergency shut-off valves.

A Case Study on the Risk Analysis for the Installation of Measurement Error Verification Facility in Hydrogen Refueling Station (수소 충전소 계량오차 검증 설비 설치를 위한 위험성 분석 사례 연구)

  • Hwayoung, Lee;Hyeonwoo, Jang;Minkyung, Lee;Jeonghwan, Kim;Jaehun, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.30-36
    • /
    • 2022
  • In commercial transactions of energy sources using hydrogen charging stations, high-accuracy flow meters are needed to prevent accidents such as overcharging due to inaccurate measurements and to ensure transparency in hydrogen commercial transactions through accurate measurements. This research developed a Corioli-type flowmeter prototype and conducted a risk assessment to prevent accidents during a process change comparison experiment for existing charging stations to verify the measurement performance. A process change section was defined for the installation of measurement facilities for empirical experiments and HAZOP was conducted. In addition, JSA was also conducted to secure the safety of experimenters, such as preventing valve mis-opening during empirical experiments. Measures were established to improve the risk factors derived through HAZOP, and work procedures were established to minimize human errors and ensure the safety of workers through JSA. The design change and system manufacturing for the installation of the metering system were completed by reflecting the risk assessment results, and safety could be confirmed through the performance comparison test of the developed meter prototype. The developed prototype flow meter showed a total of 30 flow measurements under the operating conditions of 70 MPa, and the average error was -1.58% to 3.96%. Such a metering error was analyzed to have the same performance as a flow meter installed and operated for commercial use.

Development of a Pressure Core Sampler with Built-in Data Logging System (데이터 기록 장치가 내장된 PCS (Pressure Core Sampler)의 개발)

  • Kim, Sang Il;Cho, Young Hee;Ki, Jung Seck;Kim, Dong Wook;Lee, Kye Kwang;Kim, Hae Jin;Choi, Kook Jin
    • The Journal of Engineering Geology
    • /
    • v.24 no.3
    • /
    • pp.423-429
    • /
    • 2014
  • Development of a reservoir pressure core sampler (PCS) with a built-in data logging system (DLS) for recording real-time temperature and pressure observations is critical in domestic hydrocarbon production to accurately measure and monitor reserves of shale gas, coalbed methane, and gas-hydrate. Another purpose of this new technology is to minimize the loss of gas from the core as the drill core is collected. This is accomplished by maintaining the pressure of the sample from the moment the drill core is obtained at depth, thus allowing an accurate analysis of shale gas, coalbed methane gas, and gashydrate within the core. Currently, the United States and European countries have monopolized the development and marketability of PCS technologies. We are thus developing a reservoir PCS by analyzing the operating principle and mechanisms of the existing PCS, and by conducting tests on the existing PCS. We further aim to develop a PCS with a maximum operating pressure of 100 bar, a maximum operating temperature of $-20^{\circ}C$ to $40^{\circ}C$, and a pressure loss rate of 10%.

Thermodynamic Analysis on Hybrid Turbo Expander - Heat Pump System for Natural Gas Pressure Regulation (히트펌프를 적용한 터보팽창기 천연가스 정압기지의 열역학적 분석)

  • Sung, Taehong;Kim, Kyoung Hoon;Han, Sangjo;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.13-20
    • /
    • 2014
  • In natural gas distribution system, gas pressure is regulated correspond to requirement using throttle valve which is releasing huge pressure energy as useless form. The waste pressure can be recovered by using turbo machinery devices such as a turbo expander. In this process, excessive temperature drop occurs due to Joule-Thompson effect during the expansion process. Installing natural gas boiler before or after the turbo expander prevents temperature drop. Fuel cell or gas engine hybrid system further improve the efficiency, but 1~2% of total transporting natural gas is used for operating the hybrid system. In this study, a heat pump system is proposed as a preheating device which can be operated without using transporting natural gas. Thermodynamic analysis on evaporating and condensing temperatures and refrigerants is conducted. Results show that R717 is proper refrigerant for the hybrid system with high COP and low turbine work within the defined operating conditions. In domestic usage in Korea, the heat pump system has more economic feasibility owing to natural gas being imported with a high price of LNG form.