• Title/Summary/Keyword: 가속차로

Search Result 376, Processing Time 0.036 seconds

Stereotactic Radiosurgery for Intracranial Tumors; Early Experience with Linear Accelerator (두개강내 종양에 대한 방사선 뇌수술의 역할)

  • Suh Chang Ok;Chung Sang Sup;Chu Sung Sil;Kim Young Soo;Yoon Do Heum;Kim Sun Ho;Loh John Juhn Kyu;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.7-14
    • /
    • 1992
  • Between August 1988 and December 1991, 24 patients with intracranial tumors were treated with stereotactic radiosurgery(RS) using a 10 MV linear accelerator at Severance Hospital, Yonsei University College of Medicine. There were 5 meningiomas, 3 craniopharyngiomas, 9 glial tumors, 2 solitary metastases, 2 acoustic neurinomas, 2 pineal tumors, and 1 non-Hodgkin's lymphoma. Ten patients were treated as primary treatment after diagnosis with stereotactic biopsy or neuroimaging study. Nine patients underwent RS for post-op. residual tumors and three patients as a salvage treatment for recurrence after external irradiation. Two patients received RS as a boost followed by fractionated conventional radiotherapy. Among sixteen patients who were followed more than 6 months with neuroimage, seven patients (2 meningiomas, 4 benign glial tumors, one non-Hodgkin's lymphoma) showed complete response on neuroimage after RS and nine patients showed decreased tumor size. There was no acute treatment related side reaction. Late complications include three patients with symptomatic peritumoral brain edema and one craniopharyngioma with optic chiasmal injury. Through this early experience, we conclude that stereotactically directed single high doses of irradiation to the small intracranial tumors is effective for tumor control. However, in order to define the role of radiosurgery in the management of intracraniai tumors, we should get the long-term results available to demonstrate the benefits versus potential complications of this therapeutic modality.

  • PDF

Analysis of golf swing motion for specific properties of club shaft (클럽 샤프트(Club Shaft) 특성에 따른 골프 스윙(Golf Swing)동작 분석)

  • Kim, Sung-Il;Kim, Ky-Hyoung;Kim, Hyung-Soo;Lee, Hyun-Seob;Kim, Jin-Uk;Ahn, Chan-Gyu;Kim, Hee-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.17-32
    • /
    • 2002
  • The purpose of this study was to find the rational method to analyze golf swing with specific property of club shaft. Three subjects were filmed by two high speed digital cameras with 500 fps. The phase analyzed was downswing of each subject. The three-dimensional coordinates of the anatomical landmarks were obtained with motion analysis system Kwon3d 3.0 version and smoothed by lowpass digital filter with cutoff frequency 6Hz. From these data, kinematic and kinetic variables were calculated using Matlab(ver 5.0) The variables for this study were angular velocity and accelerations, which were calculated and following conclusions have been made : 1) Golf swing time of stiff club is faster than that of regular club. 2) In shoulder joint motion of swing with the stiff club, x-stiff showed mort rapid negative acceleration than that of regular club. 3) In regular club, the velocity of club head would be more effective velocity, which was increasing, than those of other clubs before impact. 4) In wrist joint motion of swing with stiff club, x-stiff club showed faster than regular club in the downswing and impact more rapid negative acceleration.

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Comparison of Dosimetry Protocols in High Energy Electron Beams (고에너지 전자선에 대한 표준측정법간의 비교)

  • 박성용;서태석;김회남;신동오;지영훈;군수일;이길동;추성실;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.267-276
    • /
    • 1998
  • Any detector inserted into a phantom should have such a geometry that it caused as small as possible perturbation of the electron fluence. Plane parallel chambers meet this requirement better than other chambers of configurations. IAEA protocol recommends the use of plane parallel chambers for this reason. However, the cylindrical chambers are widely used for convenient. The purpose of this study is to evaluate the absorbed dose due to the differences of four different dosimetry protocols such as IAEA protocol using cylindrical chamber, TG 21 protocol using cylindrical chamber, Markus protocol using plane parallel chamber, and TG 39 report for the calibration of plane parallel chamber in electron beams. Depth-ionization measurements for the electron beams of nominal energy 6, 9, 12, 15, and 18 MeV from Siemens accelerator with a 10$\times$10 cm$^2$ field size were made using a radiation field analyser with 0.125 cc ion chamber. Dosimetric measurements by IAEA and TG 21 protocol were made with a farmer type ionization chamber in solid water for each electron energy, respectively. Dosimetric measurements by Markus protocol were made with a plane parallel ionization chamber in solid water for each electron energy, respectively. The cavity-gas calibration factor for the plane parallel chamber was obtained with the use of 18 MeV electron beam as guided by TG 39 report. Dosimetric measurements by TG 39 were performed with a plane parallel ionization chamber in solid water for each electron energy, respectively. For all the energies and protocols, measurements were made along the central axis of the distance of 100 cm (SSD = 100 cm) with 10$\times$10 cm$^2$ field size at the depth of d$_{max}$ for each electron beam, respectively. In the case of 18 MeV, the discrepancy of 0.9 % between IAEA and TG 21 was found and the two protocols were agreed within 0.7 % for other energies. In the case of 18 MeV and 6 MeV, the discrepancies of $\pm$ 0.8 % between Markus and TG 39 was found, respectively and the two protocols were agreed within 0.5 % for other energies. Since the discrepancy of 1.6 % between cylindrical and plane parallel chamber was found for 18 MeV, it is suggested to get the calibration factor using other method as guided. by TG 39.9.

  • PDF

휨 구조의 압전 마이크로-켄틸레버를 이용한 진동 에너지 수확 소자

  • Na, Ye-Eun;Park, Hyeon-Su;Park, Jong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.476-476
    • /
    • 2014
  • 서론: 저 전력 소모를 필요로 하는 무선 센서 네트워크 관련 기술의 급격한 발달과 함께 자체 전력 수급을 위한 진동 에너지 수확 기술에 대한 연구가 활발히 이루어지고 있다. 다양한 구조와 소재를 압전 외팔보에 적용하여 제안하고 있다. 그 중에서도 진동 기반의 에너지 수확 소자는 주변 환경에서 쉽게 진동을 얻을 수 있고, 높은 에너지 밀도와 제작 방법이 간단하다는 장점을 가지고 있어 많은 분야에 응용 및 적용 가능하다. 기존 연구에서는 2차원적으로 진동 에너지 수확을 위한 휜 구조의 압전 외팔보를 제안 하였다. 휜 구조를 갖는 압전 외팔보는 각각의 짧은 두 개의 평평한 외팔보가 일렬로 연결된 것으로 볼 수 있다. 하나의 짧고 평평한 외팔보는 진동이 가해지면 접선 방향으로 응력이 생겨 최대 휨 모멘텀을 갖게 된다. 그러므로 휜 구조를 갖는 외팔보는 진동이 인가됨에 따라 길이 방향과 수직 방향으로 진동한다. 하지만, 이 구조는 수평 방향으로 가해지는 진동에 대한 에너지를 수확하기에는 한계점을 가진다. 즉, 3축 방향에서 임의의 방향에서 진동 에너지를 수확하기는 어렵다. 본 연구에서는 3축 방향에서 에너지를 효율적으로 수확할 수 있도록 헤어-셀 구조의 압전 외팔보 에너지 수확소자를 제안한다. 제안된 소자는 길이 방향과 수직 방향뿐만 아니라 수평 방향으로도 진동하여 임의의 방향에서 진동 에너지를 수확할 수 있다. 구성 및 공정: 제안하는 소자는 3축 방향에서 임의의 진동을 수확하기 위해서 길이를 길게 늘이고 길이 방향을 따라 휘어지는 구조의 헤어-셀 구조로 제작하였다. 외팔보의 구조는 외팔보의 폭 대비 길이의 비가 충분히 클 때, 추가적인 자유도를 얻을 수 있다. 그러므로 헤어-셀 구조의 에너지 수확 소자는 기본적인 길이 방향, 수직방향 그리고 수평방향에 더불어 추가적으로 뒤틀리는 방향을 통해서 3차원적으로 임의의 주변 진동 에너지를 수확하여 전기적인 에너지로 생성시킬 수 있다. 제작된 소자는 높은 종횡비를 갖는 무게 추($500{\times}15{\times}22{\mu}m3$)와 길이 방향으로 길게 휜 압전 외팔보($1000{\times}15{\times}1.7{\mu}m3$)로 구성되어있다. 공정 과정은 다음과 같다. 먼저, 실리콘 웨이퍼 위에 탄성층을 형성하기 위해 LPCVD SiNx를 $0.8{\mu}m$와 LTO $0.2{\mu}m$를 증착 후, 각각 $0.03{\mu}m$$0.12{\mu}m$의 두께를 갖는 Ti와 Pt을 하부 전극으로 스퍼터링한다. 그리고 Pb(Zr0.52Ti0.48)O3 박막을 $0.35{\mu}m$ 두께로 졸겔법을 이용하여 증착하고 상부 Pt층을 두께 $0.1{\mu}m$로 순차적으로 스퍼터링하여 형성한다. 상/하부 전극은 ICP(Inductively Coupled Plasma)를 이용해 건식 식각으로 패턴을 형성한다. PZT 층과 무게 추 사이의 보호막을 씌우기 위해 $0.2{\mu}m$의 Si3N4 박막이 PECVD 공정법으로 증착되고, RIE로 패턴을 형성된다. Ti/Au ($0.03/0.35{\mu}m$)이 E-beam으로 증착되고 lift-off를 통해서 패턴을 형성함으로써 전극 본딩을 위한 패드를 만든다. 초반에 형성한 실리콘 웨이퍼 위의 SiNx/LTO 층은 RIE로 외팔보 구조를 형성한다. 이후에 진행될 도금 공정을 위해서 희생층으로는 감광액이 사용되고, 씨드층으로는 Ti/Cu ($0.03/0.15{\mu}m$) 박막이 스퍼터링 된다. 도금 형성층을 위해 감광액을 패턴화하고, Ni0.8Fe0.2 ($22{\mu}m$)층으로 도금함으로써 외팔보 끝에 무게 추를 만든다. 마지막으로, 압전 외팔보 소자는 XeF2 식각법을 통해 제작된다. 제작된 소자는 소자의 여러 층 사이의 고유한 응력 차에 의해 휨 변형이 생긴다. 실험 방법 및 측정 결과: 제작된 소자의 성능을 확인하기 위하여 일정한 가속도 50 m/s2로 3축 방향에 따라 입력 주파수를 변화시키면서 출력 전압을 측정하였다. 먼저, 소자의 기본적인 공진 주파수를 얻기 위하여 수직 방향으로 진동을 인가하여 주파수를 변화시켰다. 그 때에 공진 주파수는 116 Hz를 가지며, 최대 출력 전압은 15 mV로 측정되었다. 3축 방향에서 진동 에너지 수확이 가능하다는 것을 확인하기 위하여 제작된 소자를 길이 방향과 수평 방향으로 가진기에 장착한 후, 기본 공진 주파수에서의 출력 전압을 측정하였다. 진동이 길이방향으로 가해졌을 때에는 33 mV, 수평방향으로 진동이 인가되는 경우에는 10 mV의 최대 출력 전압을 갖는다. 제안하는 소자가 수 mV의 적은 전압은 출력해내더라도 소자는 진동이 인가되는 각도에 영향 받지 않고, 3축 방향에서 진동 에너지를 수확하여 전기에너지로 얻을 수 있다. 결론: 제안된 소자는 3축 방향에서 진동 에너지를 수확할 수 있는 에너지 수확 소자를 제안하였다. 외팔보의 구조를 헤어-셀 구조로 길고 휘어지게 제작함으로써 기본적인 길이 방향, 수직방향 그리고 수평방향에 더불어 추가적으로 뒤틀리는 방향에서 출력 전압을 얻을 수 있다. 미소 전력원으로 실용적인 사용을 위해서 무게추가 더 무거워지고, PZT 박막이 더 두꺼워진다면 소자의 성능이 향상되어 높은 출력 전압을 얻을 수 있을 것이라 기대한다.

  • PDF

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

The Effect of Pentoxifylline on Radiation-Induced Cardiac Injury in ICR Mice (방사선조사후 발생한 심장손상에서 Pentoxifylline 이 미치는 효과)

  • Suh Hyun Suk;Yang Kwang Mo;Kang Seung Hee;Kang Yun Kyung
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.281-290
    • /
    • 1996
  • Purpose : Chest irradiation leads to a significant cardiac injury in a number of patients. To prevent, or to reduce the risk of radiation-induced cardiac injury, pentoxifylline(PTX), a haemorrheologic agent that improves the blood flow through small blood capillaries has been employed. Materials and Methods : One hundred and eighty ICR mice were divided into three study groups: control, radiation alone, and radiation-pentoxifylline. Each group was subdivided into 12 subgroups: 1 3, 6 and 10 days and 2, 3, 4, 6, 8, 12, 16 and 20 weeks by observation Period after irradiation. The total 15Gy of radiation was delivered in a single fraction through anterior mediastinal port. Pentoxifylline was injected subcutaneously daily 50mg/kg to the back of the mice from the first day of irradiation throughout the observation period. The mice of each group after a certain observation period were sacrificed and sectioned for histopathologic examination of the heart. Result : The findings of acute radiation-induced carditis i.e., heterophilic infiltration and vacuolization and ballooning of endothelial cells were observed upto 6 weeks and reduced sharply afterwards. The late radiation effects including pericarditis with mononuclear cell infiltration, pericardial fibrosis, endothelial cell changes, myocardial degeneration and fibrosis present from 4 weeks onwards after irradiation but with various degree of severity. The overall process of pathologic changes of radiation-pentoxifylline group was similar to those of radiation alone group but the duration of acute stage was relatively short and the severity of late cardiac toxicity was much lesser compared with those of radiation alone group. Conclusion : Pentoxifylline can effectively reduce the late radiation-induced cardiac injury and reslve the acute effects relatively rapidly.

  • PDF

The Result of Radiotherapy for Pituitary Adenoma (뇌하수체 선종의 방사선치료 결과)

  • Lee, Hyun-Joo;Yang, Kwang-Mo;Cho, Heung-Lae;Shon, Seung-Chang;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.297-303
    • /
    • 1997
  • Purpose : To evaluate the prognostic factors for disease-free survival and long-term results of radiotherapy for pituitary adenoma. Methods and Materials : The study involved a retrospective review of out-come in a series of 27 patients with pituitary adenoma, between 1984 and 1995 at Paik hospital. The study included 20 patients treated with surgery and postoperative radiotherapy and 7 with radiotherapy alone. The patients were followed for 12-146 months (median : 97 months). Seventeen were men and 10 were women. The numbers of functioning and nonfunctioning pituitary adenorna were 22 and 5 respectively and those of microadenoma and macroadenoma were 4 and 23 respectively. The radiation doses of 5040-5580cGy (median : 5040cGy) were deliverd over 5-7 weeks, using 4MV LINAC. The prognostic factors were analyzed by log-rank test. Results: For radiation therapy alone, the 5YSR was 100% and progression free survival rate was 85.8%, The tumor was controlled in 6/7 (85.8%). For surgery and postoperative radiotherapy. the 5YSR, progression free survival rate and local control rate were 95%, 84.8%, and 89.5% respectively. The parameters of tumor size, hormone secretion, radiation dose. radiotherapy field size were evaluated in a uni- and multivariate analysis and all the factors were not statisticaIty significant (P>0.05). Eleven of 12 (92%) with visual field defect experienced normalization or improvement, and 5 for 7 evaluabie patients with hyperprolactinoma achived normalization in 4 and decrement in S patients. Only 2 patients developed mild degree of Panhypopituitarism. Conclusion: The radiotherapy appears to be effective in controiling clinical symptoms and signs resulting from pituitary adenoma. Local control rate with radiotherapy alone or with surgery and postoperative radiotherauy was comparable. There was a trend toward high recurrence rate in Patients with nonfunctioning or prolactin secretion tumor and larger radiation field sizes.

  • PDF