• Title/Summary/Keyword: 가속기 X-선

Search Result 115, Processing Time 0.035 seconds

The Effect of glutathione contents of White Ginseng(WG) Extracts and Entomopathogenic Fugi Extracts on the liver in Mice that was irradiated by radiation (동충하초 추출물과 백삼추출물 투여가 방사선을 조사한 생쥐 간에서의 glutathione함량에 미치는 영향)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.99-106
    • /
    • 2012
  • The radioprotective effects of white ginseng and Entomopathogenic Fugi Extract on liver damage induced by X-ray were investigated. To one group of ICR male mice were given white ginseng(150 mg/kg/day for 7days, orally) and Entomopathogenic Fugi (200 mg/kg/day for 7days, orally) before X-ray irradiation. To another group were irradiated by 5 Gy(1.01 Gy/min) dose of X-ray. Contrast group were given with saline(0.1 ml). The levels of reduced(GSH) and oxidized(GSSG) glutathione in liver tissue were measured. The ratio of GSSG/total GSH was significantly decreased in the white ginseng and Entomopathogenic Fugi (200 mg/kg/day)(150 mg/kg/day) groups than irradiation group.

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

Dose Distribution of Wedge filter by Dose Rate in LINAC (선형가속기의 선량율에 따른 쐐기필터의 선량분포)

  • Gwon, Taehyeong;Kim, Seunguk;Yoon, Yonghak;Won, Doyeon;Jeong, Kyeonghwan;Jung, Jaeeun;Cho, Juneho
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.323-329
    • /
    • 2015
  • This study is aimed at assessing whether dynamic wedge filters are appropriate to be used instead of physical wedge filters. The X-ray energy generated from linear accelerator is commercialize 6 MV and 10 MV. $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ of physical wedge filter was irradiated by dose rate 100, 200, 300, 400, 500, and 600 MU/min for each angle and for comparison with a dynamic wedge filter, irradiate 96 times under the same conditions. The measurement conditions are as 100 cm source-film distance and $10{\times}10cm$ irradiated surface. A developed film was scanned and analyzed after a calibration through a dose analysis program and the dose rate was compared after calculating the standard deviation. Dynamic wedge filters make dose, scattered rays and treatment time reduced and very useful due to less irradiated doses to patients. The errors at each dose rate under the same conditions were irrelevant. Thus, treatment based on a high dose rate depending on the patient is expected to be feasible.

Design and development of 1 kJ Md:Glass laser for the basic research of plasma (플라즈마 기반연구를 위한 1 kJ 급 Nd:Glass 레이저 구축)

  • Hong, S.K.;Lim, C.H.;Wee, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1457-1458
    • /
    • 2006
  • 좁은 공간에 고출력 고에너지 레이저를 집속할 때 발생하는 고밀도, 고에너지 플라즈마 연구는 상태방정식, 실험실 천체물리, 전자가속 둥 기초 분야 뿐 아니라 X-선 및 극자외선 광원 개발, 원전 유지보수 등 다양한 산업 활용 분야를 갖고 있어 최근 미국, 프랑스, 일본, 중국 등 선진강대국에서 크게 주목 받고 있는 연구 분야이다. 한국원자력연구소는 물리나 광학의 원천기술 뿐 아니라 미래 산업에 파급효과 큰 플라즈마 기반 연구를 위하여 1 kJ급 고에너지 Nd:Glass 레이저 시설을 구축하고 있다.

  • PDF

Weathering Characteristics of Sedimentary Rocks Affected by Periodical Submerging (주기적으로 침수되는 퇴적암의 풍화특성)

  • 이석훈;김수진
    • Journal of the Mineralogical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.23-35
    • /
    • 2004
  • The weathering characteristics of periodically submerged sedimentary rocks in the Sayeon dam, Ulsan was examined by field work, electron probe micro-analysis, X-ray diffraction, and X-ray fluorescence spectrometry. Analysis of fracture zone and exfoliation showed the submerged sedimentary rocks have undergone severe mechanical weathering. Mechanical weathering in the water-rock interface accelerated chemical weathering, such as dissolution and alteration of the most of minerals except for quartz in the weathering zone. The dissolution of carbonates specially calcite, is remarkable creating the cavities, whereas formation of minerals including clay minerals is not active. The sedimentary rocks have been periodically submerged for a certain period of time, and have repeated freezing and thawing. This mechanical weathering favored infiltration, which accelerated mineral dissolution. The high content of easily soluble carbonate of the sedimentary rocks is likely the major cause of intense chemical weathering. The dissolved elements within the infiltrated water interrupted the occurrence of clay and weathering minerals, and expend fractures by infiltrated water accelerated weathering process.

Experimental Study for the Irradiation Effect of High Energy X-ray on the Growth of Sprout Plants Seeds (고 에너지 X-선이 새싹식물 종자의 생장에 미치는 영향)

  • Jeon, Byeong-Kyou;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.539-545
    • /
    • 2017
  • This study examined the irradiation effect of high energy x-rays on the growth of sprout plants seeds. particularly with regard to acidity, salinity and sugar content change. The experimental groups were one day old sprout plants seeds irradiated with 6MV x-rays at doses of 2, 5, 8, 10 Gy using a linear accelerator. The control group was not irradiated. After two weeks, sprout plants were grown and harvested for component analysis. The acidity of the x-ray irradiated radish and red radish groups were significantly higher than that of the control group and bok choi and buckwheat groups lower than that of the control group. The salinity and sugar content of the x-ray irradiated 5 groups were significantly lower than that of the control group and Soybean and Red radish groups higher than that of the control group. The cause of plants component change were estimated to have occurred by generate basic ions and radiation sensitivity by moisture content. Further genetic studies will be needed to confirm the correlation between high energy x-rays and the cause of plants component change.

Effects for Growth and Chlorophyll in Old-barley and New-barley Seed exposed by X-ray (X-선이 묵은보리 씨앗과 햇보리 씨앗의 생장과 클로로필 농도에 미치는 영향)

  • Sang-Bok, Jeong;Sun-Cheol, Jeong;Mo-Kwon, Lee;Yun-Ho, Choi;Kang-Un, Byun;Su-Ah, Yu;Sang-Eun, Han;Jun-Beom, Heo;Wan-Sik, Shin;Won-Jeong, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.149-156
    • /
    • 2023
  • The purpose of this study is to compare of growth and chlorophyl between old-barley seed (OBS, 2019) and New-barley seed (NBS, 2020) exposed by X-ray. After germination the OBS and NBS, experimental group was exposed by 30 Gy X-ray using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18 × 10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) after measuring weight in 9th day. Data analysis was performed the Independent T-test using SPSS ver 26.0(Chicago, IL, USA). NBS grow more faster than OBS in control group, but OBS grow more faster than NBS in experimental group. Length of control group was longer significantly every day than that of experimental group in OBS. NBS weighted more than OBS in control group, but OBS weighted more than NBS in experimental group. In comparing chlorophyl density, NBS high more than OBS in control group as well as experimental group. Growth and weight of OBS was effected more those than NBS by X-ray, but NBS in chlorophyl by X-ray. It is expected to be used as basic data for future X-ray research in barley seed.

Diffusion and Oxidation of Ti3+ Interstitials on a Reduced TiO2 (001) Surface: A Crystal-face Dependency (TiO2 (001)면에서 Ti 결함의 확산과 산화: 결정면에 대한 의존성)

  • Kim, Yu-Kwon
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.242-248
    • /
    • 2012
  • Valence band of a vacuum-reduced $TiO_2$ (001) surface has been carefully examined using synchrotron x-ray photoelectron spectroscopy to investigate variation of the gap state upon oxidation and thermal diffusion of $Ti^{3+}$ interstitials from the bulk. We compare our results with that obtained from $TiO_2$ (110) and aim to address a crystal-face dependency in the oxidation and diffusion rates of $Ti^{3+}$ interstitials. We find very similar behaviors in the oxidation and thermal diffusion rate of $Ti^{3+}$ interstitials between the two crystal faces suggesting a negligible crystal-face dependency in this case.

The Design and Construction of the Nuclear Microprobe (핵 마이크로프로브 설계 및 제작)

  • Woo, Hyung-Ju;Kim, Jun-Gon;Choi, Han-Woo;Hong, Wan;Kim, Young-Seok;Lee, Jin-Ho;Kim, Ki-Dong;Yang, Tae-Gun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.380-386
    • /
    • 2001
  • A nuclear microprobe system with adjustable precision object slits and a magnetic quadrupole doublet was designed by the beam optics simulation using a first order matrix formalism, and installed in a $30^{\circ}$ beam line connected with KIGAM 1.7 MV Tandem VDG Accelerator. Demagnification factors for x and y axis are calculated to be 25 and 4.9, respectively, and a minimum beam spot side is expected to be about 5 $\mu\textrm{m}$ for 3 MeV proton beams with a current of about 1 nA. A multi-purpose octagonal target chamber has been built to facilitate MeV ion-beam analytical techniques of PIXE, RBS, ERDA, and ion beam micro-machining. It contains X-ray and particle detectors, a zoom microscope, a Faraday cup, a 4-axis sample manipulator and a high vacuum pumping system. The system performance of the nuclear microprobe is now being tested, and automatic manipulator control and data acquisition system will be installed for routine applications of micro ion-beam analytical techniques.

  • PDF

Expression of c-jun by X-ray According to Cell Growth State in CaSki Cell Line (CaSki 세포주에서 성장 상태에 따른 X-선에 의한 c-jun의 발현)

  • Jang, Seong-Sun;Park, Woo-Yoon
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.223-229
    • /
    • 1999
  • Purpose : The expression pattern of c-jun by ionizing radiation according to cell growth state (exponential growth vs. stationary phase) and its relationship with cell cycle redistribution were investigated. Materials and Methods : The exponential growth phase (day 4) and stationary phase (day 9) cells were determined from cell growth curve according to the elapse of days in CaSki. The cells were irradiated using 6 MV X-ray with a dose of 2 Gy at a fixed dose rate of 3 Gy/min. Northern blot analysis was peformed with total cellular RNA and cell cycle distribution was analyzed using flow cytometry according to time-course after irradiation. Results : The maximum expression of c-jun occurred 1 hour after irradiation in both exponential growth and stationary phase cells. After then c-jun expression was elevated upto 6 hours in exponential growth phase cells, but the level decreased in stationary phase cells. Movements of cells from G0-G1 to S, G2-M phase after irradiation were higher in exponential growth phase than stationary phase. Conclusion : c-jun may be involved in the regulation of cellular proliferation according to the growth states after irradiation.

  • PDF