• Title/Summary/Keyword: 가세형 소성 감쇠기

Search Result 1, Processing Time 0.02 seconds

Design of Unbend Braces to Satisfy Given Performance Acceptance Criteria (성능수준 만족을 위한 가새헝 소성 감쇠기의 설계)

  • 김진구;김유경;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.6
    • /
    • pp.47-54
    • /
    • 2001
  • Unbond brace hysteretic dampers are generally used to prevent or decrease structural damage in building structures subjected to strong earthquake by its energy dissipating hysteretic behavior. In the study, a straightforward design procedure for unbond brace hysteretic dampers was developed. The required amount of equivalent damping to satisfy given performance acceptance criteria was obtained conveniently based on the capacity spectrum method without carrying out time-consuming nonlinear dynamic time history analysis. Then the size of the unbond braces is determined from the required equivalent damping. Parametric study has been performed for the design variables such as natural period, yield strength, the stiffness after the first yield stress of the unbond brace. The procedure was applied to 5-story and 10-story steel frames for verification of the proposed method. According to the earthquake time history analysis results, the maximum displacement of the model structure with unbond braces supplied in accordance with the proposed method corresponds well with the given target displacement.

  • PDF