• Title/Summary/Keyword: 가새

검색결과 204건 처리시간 0.143초

철골 건축구조물의 내진설계를 위한 소성 전단 힌지 (Plastic Shear Hinges for the Seismic Design for Steel Building Structures)

  • 이승준
    • 전산구조공학
    • /
    • 제3권3호
    • /
    • pp.25-29
    • /
    • 1990
  • 고층건축구조물의 내진설계에서는 강성, 강도와 연성사이의 균형이 적절하게 유지되어야 한다. 이 글은 철골고층건물의 대표적인 구조시스템인 모멘트 골조와 가새골조의 내진거동에 대한 이해를 넓히고자 최근 연구되어온 Panel Zone과 Link Beam의 거동에 대한 결과와 설계시 유의사항을 간략하게 소개하였다.

  • PDF

현장타설 끼움 전단벽 및 철골가새를 활용한 기존 학교 건물의 내진보강 (Seismic Retrofit of an Existing School Building using CIP-Infilled Shear Walls and Steel Braces)

  • 윤길호;김성호;김용철;윤현도
    • 교육시설 논문지
    • /
    • 제19권4호
    • /
    • pp.21-28
    • /
    • 2012
  • This study proposes a procedure for evaluating the seismic performance and retrofit of a typical reinforced building (R/C) school buildings contructed in the 1980s. The procedure is derived from the Japanese Standard for Evaluation of Seismic Capacity of Existing Reinforced Concrete Buildings and Nonlinear Static Procedure (NSP) specified in Federal Emergency Management Agency (FEMA 356). In this study, the Japanese Standard was applied for evaluating the additionally required seismic performance in the existing school building. Cast-in-place (CIP) reinforced concrete infill walls and steel braces were used to seismically retrofit the existing school building located in the region of Hongsung in Chungnam. In the pushover analysis, i.e NSP, the hinge properties of columns, beams, infill walls and steel braces were carefully calibrated based on the existing experiment results in the available literatures. The predicted seismic performance for the retrofitted building was compared to that for the virgin building. Based on the seismic evaluation with the Japanese Standard and the FEMA 356 criteria, the addition of CIP reinforced concrete infill walls and steel braces have superior constructablility and can improve effectively the seismic performance of the existing school buildings constructed in 1980s.

직사각형 댐퍼의 비선형 해석 및 설계 (Nonlinear Analysis and Design of Rectangular Damper)

  • 엄승현;김원기
    • 한국강구조학회 논문집
    • /
    • 제15권4호통권65호
    • /
    • pp.447-456
    • /
    • 2003
  • 본 연구에서는 외부프레임이 직사각형일 때 적절한 댐퍼의 형태를 결정하였다. 댐퍼의 형태는 외부프레임과 같은 비율로 직사각형이다. 설계의 기본은 지정된 내진성능을 가진 사각형 댐퍼로 충격에너지를 소산하는 것이다. 본 논문의 내용에서 비선형 해석 데이터와 실험 데이터 각각의 강도와 에너지 소산을 하중-변위 곡선을 통하여 비교하였다. 반복하중 실험을 해석하기 위한 ANSYS 유한요소법 소프트웨어의 접근방법을 제시하였다. 본 논문의 궁극적인 목적은 효율적인 직사각형 인장 가새용 댐퍼의 형태를 연구하는데 있다. 우수한 가공성을 적용하여 개발된 직사각형 댐퍼의 안전성을 검토하였다.

내풍설계된 초고층 철골중심가새골조의 지진응답 해석 (Seismic Response Analysis of Wind-Designed Concentrically Braced Steel Highrise Buildings)

  • 이철호;김선웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.60-67
    • /
    • 2004
  • The designer of a tall building even in moderate and low seismic regions should, in finalizing the desist consider the probable impact of the design basis earthquake on the selected structural system. In this study, seismic response analysis was conducted to evaluate the seismic performance of concentrically braced steel highrise buildings which were designed only for governing wind loading under moderate seismicity. The main purpose of this analysis was to see if the wind design would create a system whose elastic capacity clearly exceeds the probable demand as suggested by the design basis earthquake. The strength demand-to-capacity study revealed that the wind-designed steel highrise buildings with the aspect ratio of larger than five can withstand the design basis earthquake elastically by a sufficient margin due to the system over-strength resulting from the wind-serviceability criterion. The maximum story drift demand from the design basis earthquake was just 0.25% (or half the limit of Immediate Occupancy performance level in FEMA 273)

  • PDF

토글가새와 납-고무 제진장치를 적용한 구조물 진동제어 실험 (Experiments for the Vibration Control of Steel Frame Structure Using Toggle Brace and Lead Rubber Damper)

  • 박정우;박진영;이완하;김기만;박건록
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.171-176
    • /
    • 2011
  • The purposes of the research were to evaluate system performance and response of building structure under external load for full scale modal-testing-tower applied toggle bracing and lead rubber damper(LRD). The dynamic properties of the structure were measured before and after installing damper under harmonic excitation using the AMD and the results were compared. The harmonic excitation condition is to increase 0.01Hz sine sweep signal from 0.49Hz to 0.63Hz. As a result of measuring resonant frequency, before installing damper is 0.55Hz and after installing damper is 0.62Hz. The experimental results after installing damper were also distinguished from simulation results and the main cause of this results is temperature dependency property of rubber material.

  • PDF

초탄성 형상기억합금 능동제어 가새시스템을 이용한 중심가새프레임 구조물의 지진거동 및 복원성능 평가 (Seismic Behavior and Recentering Capability Evaluation of Concentrically Braced Frame Structures using Superelastic Shape Alloy Active Control Bracing System)

  • 허종완;이두재;조양희
    • 한국지진공학회논문집
    • /
    • 제16권6호
    • /
    • pp.1-12
    • /
    • 2012
  • The researches related to active control systems utilizing superelastic shape memory alloys (SMA) have been recently conducted to reduce critical damage due to lateral deformation after severe earthquakes. Although Superelastic SMAs undergo considerable inelastic deformation, they can return to original conditions without heat treatment only after stress removal. We can expect the mitigation of residual deformation owing to inherent recentering characteristics when these smart materials are installed at the part where large deformation is likely to occur. Therefore, the primary purpose of this research is to develop concentrically braced frames (CBFs) with superelastic SMA bracing systems and to evaluate the seismic performance of such frame structures. In order to investigate the inter-story drift response of CBF structures, 3- and 6-story buildings were design according to current design specifications, and then nonlinear time-history analyses were performed on numerical 2D frame models. Based on the numerical analysis results, it can be comparatively verified that the CBFs with superelastic SMA bracing systems have more structural advantages in terms of energy dissipation and recentering behavior than those with conventional steel bracing systems.

강판과 가새로 보강된 무량판 구조물의 내진 성능평가 (Seismic Performance Evaluation of Flat Plate Structures Retrofitted with Steel Plates and Braces)

  • 신우승;김진구
    • 한국전산구조공학회논문집
    • /
    • 제21권5호
    • /
    • pp.451-458
    • /
    • 2008
  • 본 논문에서는 중 약진 지역에서 중력 저항시스템인 중간 모멘트골조로 설계된 3층, 6층 RE 플랫플레이트 구조물을 KBC 2005를 만족하도록 RC구조물에 강판과 가새/ BRB 등의 보강방법을 적용하여 보강하고, 내진성능을 평가하여 보강 효과를 검증하였다. 비탄성 정적해석과 동적해석 결과에 따르면 내진 보강된 구조물은 강도와 강성이 크게 향상된 것으로 나타났다 특히 기둥을 철판으로 보강한 경우 슬래브를 철판으로 보강하여 조기 뚫림 전단파괴를 방지함으로써 강도를 크게 향상할 수 있다. BRB로 보강된 구조물은 Brace로 보강된 구조물보다 다소 연성적 거동을 보였으며, 그 효과는 3층 모델에서 현저하게 나타났다.

주기하중을 받는 골조강판벽의 실험연구 (Framed Steel Plate Wall subject to Cyclic Lateral Load)

  • 박홍근;곽재혁;전상우;김원기
    • 한국강구조학회 논문집
    • /
    • 제16권6호통권73호
    • /
    • pp.781-792
    • /
    • 2004
  • 스티프너가 없는 얇은 강판을 사용한 골조강판벽 시스템에 대한 실험연구를 실시하였다. 1경간 3층의 골조강판벽에 주기횡하중을 재하하였으며, 주요한 실험 변수는 강판의 두께, 기둥의 강도이다. 실험결과를 이용하여 강판벽의 강도, 변형능력, 에너지 소산능력을 연구하였으며, 이를 토대로 골조강판벽의 파괴메카니즘을 분석하였다. 실험결과, 얇은 강판을 사용하는 골조강판벽은, 높은 강도, 낮은 연성능력, 캔틸레버거동특성을 나타내는 일반적인 가새골조나 스티프너 보강된 강판벽과는 여러 면에서 다른 거동특성을 나타낸다. 골조강판벽에서는 강판의 조기국부좌굴과 인장응력장 작용이 발생하면서, 전 층에 고르게 항복변형이 분포된다. 이로 인하여 변형형태는 휨변형과 전단변형의 복합형태를 나타내며, 우수한 강도 및 에너지 소산능력과 연성모멘트 골조에 버금가는 변형능력을 나타내었다. 그러나 일반적인 가새골조와는 달리 보, 기둥 등의 골조부재는 강판의 인장응력장을 지지할 수 있도록 설계되어야 하며, 따라서 기둥의 강도가 작고 콤팩트 단면을 사용하지 않은 경우에는 약층현상이 발생하며 강도가 급격히 저하되었다. 얇은 강판을 사용하는 골조강판벽은 일반적인 가새골조나 스티프너 보강 강판벽과는 차별되는 우수한 변형능력을 갖고 있으므로 연성내진구조시스템으로 활용할 수 있다.