• Title/Summary/Keyword: 가상적 재현

Search Result 237, Processing Time 0.021 seconds

Exhibition Hall Lighting Design that Fulfill High CRI Based on Natural Light Characteristics - Focusing on CRI Ra, R9, R12 (자연광 특성 기반 고연색성 실현 전시관 조명 설계 - CRI Ra, R9, R12를 중심으로)

  • Ji-Young Lee;Seung-Teak Oh;Jae-Hyun Lim
    • Journal of Internet Computing and Services
    • /
    • v.25 no.4
    • /
    • pp.65-72
    • /
    • 2024
  • To faithfully represent the intention of the work in the exhibition space, lighting that provides high color reproduction like natural light is required. Thus, many lighting technologies have been introduced to improve CRI, but most of them only evaluated the general color rendering index (CRI Ra), which considers eight pastel colors. Natural light provides excellent color rendering performance for all colors, including red and blue, expressed by color rendering index of R9 and R12, but most artificial lighting has the problem that color rendering performance such as R9 and R12 is significantly lower than that of natural light. Recently, lighting technology that provides CRI at the level of natural light is required to realistically express the colors of works including primary colors but related research is very insufficient. Therefore this paper proposes exhibition hall lighting that fulfills CRI with a focus on CRI Ra, R9, and R12 based on the characteristics of natural light. First reinforcement wavelength bands for improving R9 and R12 are selected through analysis of the actual measurement SPD of natural and artificial lighting. Afterward virtual SPDs with a peak wavelength within the reinforcement wavelength band are created and then SPD combination conditions that satisfy CRI Ra≥95, R9, and R12≥90 are derived through combination simulation with a commercial LED light source. Through this, after specifying two types of light sources with 405,630nm peak wavelength that had the greatest impact on the improvement of R9 and R12, the exhibition hall lighting applied with two W/C White LEDs is designed and a control Index DB of the lighting is constructed. Afterward experiments with the proposed method showed that it was possible to achieve high CRI at the level of natural light with average CRI Ra 96.5, R9 96.2, and R12 94.0 under the conditions of illuminance (300-1,000 Lux) and color temperature (3,000-5,000K).

Dynamic Network Loading Model based on Moving Cell Theory (Moving Cell Theory를 이용한 동적 교통망 부하 모형의 개발)

  • 김현명
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.5
    • /
    • pp.113-130
    • /
    • 2002
  • In this paper, we developed DNL(Dynamic Network Loading) model based on Moving cell theory to analyze the dynamic characteristics of traffic flow in congested network. In this paper vehicles entered into link at same interval would construct one cell, and the cells moved according to Cell following rule. In the past researches relating to DNL model a continuous single link is separated into two sections such as running section and queuing section to describe physical queue so that various dynamic states generated in real link are only simplified by running and queuing state. However, the approach has some difficulties in simulating various dynamic flow characteristics. To overcome these problems, we present Moving cell theory which is developed by combining Car following theory and Lagrangian method mainly using for the analysis of air pollutants dispersion. In Moving cell theory platoons are represented by cells and each cell is processed by Cell following theory. This type of simulation model is firstly presented by Cremer et al(1999). However they did not develop merging and diverging model because their model was applied to basic freeway section. Moreover they set the number of vehicles which can be included in one cell in one interval so this formulation cant apply to signalized intersection in urban network. To solve these difficulties we develop new approach using Moving cell theory and simulate traffic flow dynamics continuously by movement and state transition of the cells. The developed model are played on simple network including merging and diverging section and it shows improved abilities to describe flow dynamics comparing past DNL models.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF

Aesthetics of Samjae and Inequilateral Triangle Found in Ancient Triad of Buddha Carved on Rock - Centering on Formative Characteristics of Triad of Buddha Carved on Rock in Seosan - (고대(古代) 마애삼존불(磨崖三尊佛)에서 찾는 삼재(三才)와 부등변삼각(不等邊三角)의 미학(美學) - 서산마애삼존불의 형식미를 중심으로 -)

  • Rho, Jae-Hyun;Lee, Kyu-Wan;Jang, Il-Young;Goh, Yeo-Bin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.3
    • /
    • pp.72-84
    • /
    • 2010
  • This study was attempted in order to offer basic data for implementing and applying Samjonseokjo(三尊石造), which is one of traditional stone construction method, by confirming how the constructive principle is expressed such as proportional beauty, which is contained in the modeling of Triad of Buddha Carved on Rock that was formed in the period of the Three States, centering on Triad of Buddha Carved on Rock in Susan. The summarized findings are as follows. 1. As a result of analyzing size and proportion of totally 17 of Triad of Buddha Carved on Rock, the average total height in Bonjonbul(本尊佛) was 2.96m. Right Hyeopsi(右挾侍) was 2.19m. Left Hyeopsi(左挾侍) was 2.16m. The height ratio according to this was 100:75:75, thereby having shown the relationship of left-right symmetrical balance. The area ratio in left-right Hyeopsi was 13.4:13.7, thereby the two area having been evenly matched. 2. The Triad of Buddha Carved on Rock in Seosan is carved on Inam(印岩) rock after crossing over Sambulgyo bridge of the Yonghyeon valley. Left direction was measured with $S47^{\circ}E$ in an angle of direction. This is judged to target an image change and an aesthetic sense in a Buddhist statue according to direction of sunlight while blocking worshipers' dazzling. 3. As for iconic characteristics of Buddha Carved on Rock in Seosan, there is even Hyeopsi in Bangasang(半跏像) and Bongjiboju(捧持寶珠) type Bosangipsang. In the face of Samjon composition in left-right asymmetry, the unification is indicated while the same line and shape are repeated. Thus, the stably visual balance is being shown. 4. In case of Triad of Buddha Carved on Rock in Seosan, total height in Bonjonbul, left Hyeopsi, and right Hyeopsi was 2.80m, 1.66m, and 1.70m, respectively. Height ratio in left-right Hyeopsibul was 0.60:0.62, thereby having been almost equal. On the other hand, the area ratio was 28.8:25.2, thereby having shown bigger difference. The area ratio on a plane was grasped to come closer to Samjae aesthetic proportion. 5. The axial angle of centering on Gwangbae was 84:46:50, thereby having been close to right angle. On the other hand, the axial angle ratio of centering on Yeonhwajwa(蓮華坐: lotus position) was measured to be 135:25:20, thereby having shown the form of inequilateral triangle close to obtuse angle. Accordingly, the upper part and the lower part of Triad of Buddha Carved on Rock in Susan are taking the stably proportional sense in the middle of maintaining the corresponding relationship through angular proportion of inequilateral triangle in right angle and obtuse angle. 6. The distance ratio in the upper half was 0.51:0.36:0.38. On the other hand, the distance ratio in the lower half was 0.53 : 0.33 : 0.27. Thus, the up-down and left-right symmetrical balance is being formed while showing the image closer to inequilateral triangle. 7. As a result of examining relationship of Samjae-mi(三才美) targeting Triad of Buddha Carved on Rock in Susan, the angular ratio was shown to be more notable that forms the area ratio or triangular form rather than length ratio. The inequilateral triangle, which is formed centering on Gwangbae(光背) in the upper part and Yeonhwajwa(lotus position) in the lower part, is becoming very importantly internal motive of doubling the constructive beauty among Samjae, no less than the mutually height and area ratio in Samjonbul.

Anger-coping types and hypertension in some employed men (일부 남자 고용집단에서 분노 대응형태와 고혈압)

  • Lee, Choong-Won;Park, Jong-Won;Lee, Se-Youp
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.2 s.50
    • /
    • pp.462-472
    • /
    • 1995
  • This study examined the relation between anger-coping types and hypertension in employed men aged $40\sim60$ who consented to participate during the biannual physical checkup in the department of health management in 1988. The subjects analyzed were five hundred thirteen excluding those having hypertension history and/or current antihypertensive medications. Anger-coping types were constructed from the Harburg's model with two hypothetical anger-provoking situations involving wife and boss. Hypertensives were defined more than 140mmHg systolic blood pressure and/or 90mmHg diastolic blood pressure. Hypertensives were one hundred fifty two(29.6%) and those who suppressed their anger were 61.6% and 62.8% in wife and boss situations respectively. Items of anger, guilt, protest, and suppressed anger in wife situation showed odds ratios of 0.78-0.94 without statistical significance. But four items in boss situation showed odds ratios more than 1, especially anger-in types of anger item had 1.58 times the prevalence of hypertension of anger-out types(95% confidence intervals(CI) $1.06\sim2.35$) and subjects who indicated that suppressed their anger had 1.55 times the prevalence of hypertension of those who expressed their anger(95% CI $1.03\sim2.32$). For anger suppressed vs. expressed types of total suppressed anger index, prevalence of hypertension was 1.31 (95% CI $0.83\sim2.08$). After adjusting for age, body mass index, smoking and drinking, the odds ratios were slightly increased in both situations except guilt items compared with univariate analysis. These results suggest that the relation between Harburg's anger-coping model and hypertension is replicated partially in this subjects.

  • PDF

Distortion of the Dose Profile in a Three-dimensional Moving Phantom to Simulate Tumor Motion during Image-guided Radiosurgery (방사선수술에서 종양 움직임을 재현시킨 움직이는 팬텀을 이용하여 선량 분포의 왜곡에 대한 연구)

  • Kim, Mi-Sook;Ha, Seong-Hwan;Lee, Dong-Han;Ji, Young-Hoon;Yoo, Seong-Yul;Cho, Chul-Koo;Yang, Kwang-Mo;Yoo, Hyung-Jun;Seo, Young-Seok;Park, Chan-Il;Kim, Il-Han;Ye, Seong-Jun;Park, Jae-Hong;Kim, Kum-Bae
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.268-277
    • /
    • 2007
  • Purpose: Respiratory motion is a considerable inhibiting factor for precise treatment with stereotactic radiosurgery using the CyberKnife (CK). In this study, we developed a moving phantom to simulate three-dimensional breathing movement and investigated the distortion of dose profiles between the use of a moving phantom and a static phantom. Materials and Methods: The phantom consisted of four pieces of polyethylene; two sheets of Gafchromic film were inserted for dosimetry. Treatment was planned to deliver 30 Gy to virtual tumors of 20, 30, 40, and 50 mm diameters using 104 beams and a single center mode. A specially designed robot produced three-dimensional motion in the right-left, anterior-posterior, and craniocaudal directions of 5, 10 and 20 mm, respectively. Using the optical density of the films as a function of dose, the dose profiles of both static and moving phantoms were measured. Results: The prescribed isodose to cover the virtual tumors on the static phantom were 80% for 20 mm, 84% for 30 mm, 83% for 40 mm and 80% for 50 mm tumors. However, to compensate for the respiratory motion, the minimum isodose levels to cover the moving target were 70% for the $30{\sim}50$ mm diameter tumors and 60% for a 20 mm tumor. For the 20 mm tumor, the gaps between the isodose curves for the static and moving phantoms were 3.2, 3.3, 3.5 and 1.1 mm for the cranial, caudal, right, and left direction, respectively. In the case of the 30 mm tumor, the gaps were 3.9, 4.2, 2.8, 0 mm, respectively. In the case of the 40 mm tumor, the gaps were 4.0, 4.8, 1.1, and 0 mm, respectively. In the case of the 50 mm diameter tumor, the gaps were 3.9, 3.9, 0 and 0 mm, respectively. Conclusion: For a tumor of a 20 mm diameter, the 80% isodose curve can be planned to cover the tumor; a 60% isodose curve will have to be chosen due to the tumor motion. The gap between these 80% and 60% curves is 5 mm. In tumors with diameters of 30, 40 and 50 mm, the whole tumor will be covered if an isodose curve of about 70% is selected, equivalent of placing a respiratory margin of below 5 mm. It was confirmed that during CK treatment for a moving tumor, the range of distortion produced by motion was less than the range of motion itself.